METAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV
ATR VERSION MIX is a MV modular protected panel with metallic envelope suitable to can also be designed and manufactured. Atr version mix panel can be realized in standard or arc-proof version according to IEC 62271-200 / 11-2003 standard. SPECIFICATIONS
ATR METAL-ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, AIR INSULATED UP TO 36 KV
ATR ATR ATR is a modular protected panel with metallic case for indoor installation. It is de- Atr panel can be in standard or arc-proof version according to IEC 62271-200 / 11-2003 standard. SPECIFICATIONS
METAL CLAD TRI-PHASE MV BUS DUCT, UP TO 36kV
Blindopower is a 3-phase MV bus duct with a rectangular section, enclosed in an aluminum case epoxy painted. It can be metallically segregated or not, according to cells, transformers outlets, generators outlets and for a safe supply in bars of a power plants. SPECIFICATIONS
SWITCHBOARD FOR CONTROL OF LOW VOLTAGE MOTORS ORS
Euro MCC is a switchboard designed for operations, control and protection of operating motors, and it is composed of standard modular columns with withdrawable drawers. This switchboard guarantees continuity of service and safety for personnel. Its strenghtness makes it suitable to the most demanding installations such as appli- SPECIFICATIONS До До До
CONTROL AND PROTECTION SWITCHBOARD
Euro P&C is a switchboard designed to house a variety of accessories and equipments be used also in other applications.the sturdiness of its construction makes it ideal for many other applications.
LV MAIN SWITCHBOARD
Euro PC is a switchboard designed for primary electrical power distribution at low voltage. This switchboard guarantees continuity of service and safety for personnel. Its sturdiness makes it suitable to the most demanding installations such as applications SPECIFICATIONS До До До До
LV DISTRIBUTION SWITCHBOARD
Euro SDS is a switchboard designed for the operation, control and protection of LV circuits used in secondary distribution. It s composed of standard modular columns, and every switch is mounted in its compartment. If several modular switches need to be installed, this is done within the same compartment. The simplicity of this switchbo- buildings, electrical substations, industrial plants, shopping centers, hospitals etc.. SPECIFICATIONS До До До До До Внутренний Внешний
METAL-CLAD STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, AIR INSULATED UP TO 36KV
Normal Clad is a MV modular metal clad panel with metallic case for indoor installa- special applications can also be designed and manufactured. Normal Clad can be supplied in standard or arc-proof on four sides version, according to IEC 62271-200 / 11-2003 standard. SPECIFICATIONS
ENGINEERING SOLUTIONS FOR ELECTRIC POWER GENERATION, TRANSMISSION AND DISTRIBUTION
Thanks to its staff of engineers and technicians, CR technology Systems is able to deal with any request from the customers and propose engineering solutions for the generation, transmission and distribution of electricity. The twenty-year experience of its engineer planners allows C.R. to realize different projects and jobs all around the world,thanks also to the collaboration with other partners. Among the most important job realized we mention the installation of cabinets in the historical center of Rome, the supply of compact substations for the North-African desert, the supply of cabinets all over the world, modernization of substations in some Mediterranean islands, the modernization of thermoeletric plants in Cuba, electromechanical projects in Czech Republic, the installation of high-voltage substations in Cuba, the modernization of
COMPACT SUBSTATION UP TO 36KV
CR Technology Systems supplies transportable compact substations up to 36 KV, for power stations. This Product was created at the end of 2004, it is a modular construction, with our LV and MV switchboards installed inside, according to client requirements. It is a versatile product that can be provided both completely assembled or transport operations.
PREFABRICATED SYSTEM FOR SUBSTATIONS CONTROL AND COMMAND ROOMS
Euro FMS is a prefabricated system that allows the manufacture on site of complete buildings suitable to house control rooms and electric power plants. The whole sy- there s no need to use special machines or tools because construction includes a kit ners. It is only necessary to prepare a reinforced concrete base to lay the structure. The dimensions of euro FMS only limitation is for the transport. For buildings white unique roof and just one pitch, the maximum width can be 11 m, for buildings white double roof and double pitch, width, can be 22 m; the are no limitations for lenght as compositions are made with panels.
GAS ENCLOSED LOAD BREAK SWITCH AND SECTIONALISER UP TO 38KV WITH MANUAL AUTOMATIC AND REMOTE CONTROL OPTIONS.
SWITCH MIX-PL is a 3 phase, SF6 gas insulated load break switch (LBS) for overhead power distribution system. SWITCH MIX-PL series switches have been designed to meet the growing requirements for oil-less maintenance free, long life, maximum safety and possibility to interface with Distribution Automation System (DAS) o SCADA System. Available up to 38kV, the SWITCH MIX-PL switch has been designed with the latest SF6 puffer switching technology to achieve high performance and reliability. The SWITCH MIX-PL (LBS) can be operated both manually by mean of an hook stick or being equipped for automatic operations. The SWITCH MIX-PL (LBS) provides the answers to all sectionalizing and network automation requirements. actuator, Surge arrestors brackets, Stainless steel tank sealed for life,polymeric or Porcelain bushings, Gas pressure indicator, Overpressure bursting disc, Low gas pressure lockout device. For network automation requirements the SWITCH MIX-PL (LBS) is equipped with our Remote Terminal Unit (RTU type 1) or (RTU type 2), which provides telecontrol and automation interface to customer Master SCADA or DMS. Some other features will be obtained in this version as local and remote operation, DNP3 and IEC 60870-5-101/104 communication. SPECIFICATIONS Maximum System Voltage 15 kv 25.8 kv 38 kv Rated Continuous Current 630 A 630 A 630 A Rated Frequency 50/60 Hz 50/60 Hz 50/60 Hz Short Time Withstand Current ( rms) 20 ka/ 4sec 25kA/ 1sec 20 ka/1 sec Mainly Active Load Breaking Capacity 630A 630A 630A Number of Load-break Operations 400 400 400 Short-circuit Making Current (peak) 50 kap 32.5kAp 32.5 kap Number of Making Operations 5 5 5 Cable Charging Current 10A 25A (200 A) 20 A Internal Arc Test 20kA /0.1 sec 20kA /0.1 sec 20kA /0.1 sec Arc Extinction Medium SF 6 Gas SF 6 Gas SF 6 Gas Insulation Medium SF 6 Gas SF 6 Gas SF 6 Gas Creepage Distance (Porcelain) 550 mm 740 mm 960 mm Creepage Distance (Silicon) 615 mm 800 mm 1055 mm IP Level 54 54 54 Closing / Opening Time (A Type) 0.7 sec 0.7 sec 0.7 sec Line Charging Current 1A 1.5A 2A Open 50 50 50 Closed Loop Circuit Current 630 A 630 A 630 A Transformer Magnetizing Current 22A 22A 22A Close < 0.7 sec < 0.7 sec < 0.7 sec Spring Charge < 0.4 sec < 0.4 sec < 0.4 sec Mechanical Operations (Guaranteed) 10,000 10,000 "10,000 Wet Condition- 10 sec (Ph- Ph, Ph-Eth, Across Interrupters) 45 kv 50kV 70 kv Operating Temperature (*Manual Type) -25 (*-40) ~ 70 C -25 (-40) ~ 70 C - 25 (-40)~ 70 C Dry Condition - 1 min (Phase to Earth, Phase to Earth) 50 kv 60kV 70 kv Dry Condition - 1 min( Across Interrupter ) 50 kv 60kV 80 kv Phase to Phase, Phase to Earth 110 kv 150kV 170 kv Nominal Pressure (kgf/cm2 G, at 20 C) 10 10 10 Bursting Pressure (kgf/cm2 G) 4 ~ 6 4 ~ 6 4 ~ 6 Minimum Gas Pressure (kgf/cm2 G) 1 0 0 Across Interrupter 125 kv 150kV 195 kv Leakage Rate (cc/ sec) 1.1 x 10-7 1.1 x 10-7 8.2 x 10-7
Optimal solution for the modernization of old energy production and distribution plants. - Replacement of components or parts of existing plants with equipments and solutions in line with technology state of the art; - Short execution and replacement times; - Technical assistance. - Extension of plants life cycle; - Minimization of service breakdown; - Reduction of maintenance costs; - The old plants can be used again; - Easy to use for operator; - Guarantee on work conversion and on availability; - Valid alternative to big investments for total replacement of plants.