Submittal Data Information

Similar documents
Submittal Data Information

TDX - Taco Duplex Starter with

Designed for ease of integration with automation systems

P-SERIES VFD WITH BYPASS

INDUSTRIAL STARTERS ADVANCED SOLUTIONS FOR INDUSTRIAL APPLICATIONS

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

EPS-ECONOMY PUMP STARTER

SECTION MOTOR CONTROL

RVS-DN Digital Reduced Voltage Motor Starter

KD LV Motor Protection Relay

825-P Modular Protection System for motors Specification Guide

A200 NEMA Contactors and Starters A200

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

Bulletin 825 SMM Smart Motor Manager

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Metasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents

Contactors & Overload relays

RVS-DX Digital Reduced Voltage Motor Starter

Application Description

Technical Information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Type S611, Solid-State Soft Starter. Full-featured High Performance Ease of use

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

CTi Automation - Phone: Fax: Web:

XM1 - Motor protection relay

Technical Information

ESW/PESW. Non-Combination Starters

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

EPS-ECONOMY PUMP STARTER

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

VA9203-AGx / VA9203-Bxx / VA9203-GGx

L&T SWITCHGEAR S A F E & S U R E. Moulded Case Circuit Breakers

Moulded Case Circuit Breakers

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

University of Houston Master Construction Specifications Insert Project Name

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

DEEP SEA ELECTRONICS PLC

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

Selection Guide Motor Control Device Solutions

WARREN COUNTY, N.Y. M/E REFERENCE

Meta Solution. Contactors and Overload relays

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

AF40... AF96 3-pole contactors Technical data

Series CA5 Contactors

MAGNETIC MOTOR STARTERS

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

DSEULTRA DSE6000 Quick Start Guide Document Number

OPERATING INSTRUCTIONS ECON-M

Industrial Contactors CTX 3 3P 185A - 800A

Contactor Types CI 61-98

C -5 to +55 (0.8 to 1.1Uc) Permissible o

USERS MANUAL MCD REMOTE OPERATOR

Product Description. Application Description

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

BAC Custom Engineered Controls

Ktec Contactors and thermal overloads

About us. Switchgear Factory, Mumbai


Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Features and Benefits. Control Features

CI-TI Contactors and motor starters Types CI 61 - CI 98

ABB Softstarter Benefits Charnchanok Thongprad

Hp V AC Current Rating [A] 230V AC 60 Hz

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Degree of protection: IP 55 Power supply voltage: 230V/ 1F 50 Hz External dimensions: mm Weight: Kg 0.6

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

NB1 Miniature Circuit Breaker

Emotron DCM Control Unit

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

General Information. standard and advanced modular dimming. Sensor 96 dimmer rack

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

OPERATING INSTRUCTIONS MCP-MT1

NOTICE. Installation of MAM 8** can be performed only by professional technician

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

Series Motor Protection

Standby Amper VOLTAGE

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Manual motor starter MS132

Variable speed drives

HPS2DB Serial Softstarter Operation Manual

GTEC Transfer switch Open transition

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Transcription:

Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V, 1/2-100HP HO Keypad with LCD Display BCnet Comms, power metering, underload (dry run) Features Power metering 1% NSI grade metering Pulse/analog output for accurate measurements (optional) kw and kwh data available on LCD display Superior pump protection Protection - 1-95 Electronic Overload - Locked rotor - Cycle fault - Max time to start - Out of calibration (detects incorrect FL setting) Selectable trip class 5-30 Current and voltage phase unbalance Over/under power - Prevents dry run pump damage Over/under voltage Reverse phase Proof of flow verification True power measure detects belt loss and alerts automation system Eliminates costly current sensors Voltage & dry contact inputs for auto run command Wire directly from the automation system to the starter, no interposing relays necessary Save on installation costs and increase reliability. Valve control Provides a 24VC (or optional 120VC) output for powering a motorized valve actuator Interlocks valve with starter ensuring proper sequence of operation Prevents damage to pipes, saves energy from heat loss Saves on automation panel points, reduces wiring, saves on installation costs HO keypad with LCD display Plain English operation easy to set up and simple to operate LEDs indicate Hand/Off/uto modes, run and fault conditions Flexible control transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection Combination versions include disconnect Motor circuit protection disconnect provides short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required Lockable handle for safety BCnet or Modbus Communications with power metering for energy savings Ideal for LEED projects (Measurement & Verification credit), tenant sub-metering cost allocation, load shedding and performance contracting Native RS-485 76800 BPS for high performance Comprehensive point list including HO status, overload faults, and all metering attributes (kw, kwh, kvar, V,, etc. aggregate and per phase). Includes power metering display with programmable parameters Tested to BTL standards Fault Logging Records up to 100 faults and alarms (e.g. underpower, overload, etc.)

TS Specifications Starter Type TS - Taco dvanced Starter 120-600VC, 1 & 3-Phase, 50/60Hz input, cross the line, full-voltage non-reversing NEM Type 1 or 3R Enclosed User Interface Hand-Off-uto Door mounted Hand-Off-uto keypad (water-tight-membrane) Programming Door mounted display with programming keys (LCD, back-lit, 16 character) Mode Indication Integrated LEDs, Hand-Off-uto-Run-Fault indication Standard Control Operations Inputs Outputs Operational Voltage uto-run Dry Contact uto-run Fireman s Override Float Switches Permissive uto ctuator Position Switch Status Relay Fault Relay ctuator Power Overload Type Power Fail Modes ccepts 12-130VC/DC. pplying voltage will send a run command to the starter when in uto mode. Normally Open dry contact. When closed, the starter will be commanded to run when in uto mode. ccepts 12-130VC/DC. pplying voltage will command the motor to run in all modes and will supersede a Shutdown command. Hand/Off/uto/Run/Fault LEDs will flash. 2) Programmable Normally Open or Normally Closed dry contacts. Normally Open dry contact. When closed, the starter will not accept a run command when in uto mode. Normally Open dry contact. To be used in series with customer provided actuator contacts which disable the motor starter until the actuator is in position. (ie. The contactor will not close unless this contact is closed) Normally Open relay contacts. Status Relay will close when the motor draws a user defined percentage of the FL setting. Fault Relay will close in the event of a fault trip. Contact Ratings: 0.3 @ 125VC, 1 @ 24VC 24VC, 1 max. (Optional 120VC, 0.25 max.) Electronic, I 2 t trip curve Restart in last mode (Hand/Off/uto) with no delay (default) Restart in Off mode Restart in Off mode if power failure lasts longer than 2 seconds. Restart in last mode if power failure is less than 2 seconds. On/Off, djustable: 0.1-99 seconds djustable: Manual or utomatic On/Off Time Delay Fault Reset Environmental mbient Operating Temp -5 to 140 F (-20 to 60 C) mbient Storage Temp -5 to 185 F (-20 to 85 C) Relative Humidity 5% to 95% non-condensing Motor Protection djustment / Description Default Setting Overload Current Setting Range Differs per model Per FL Overload Trip Class djustable: 5-30 10 Overload Service Factor djustable: 0.00-2.00 1.15 Under Power On/Off, djustable: 0-99% of measured electrical input Off / 60% Over Power On/Off, djustable: 101-200% of measured electrical input Off / 120% Over / Under Voltage On/Off, djustable: +5-25% over/under the nominal voltage setting On / 10% Voltage Phase Unbalance On/Off, djustable: 1-20% voltage phase deviation On / 3% Voltage Phase Loss lways On, djustable: 1-50% voltage phase deviation 5% Voltage Phase Sequence Reversal On/Off, Trips within 0.1 seconds upon voltage phase reversal detection On Ground Fault (Optional) On/Off, djustable: 1.0-9.9 Off / 1 Cycle Fault On/Off, Trips if contactor cycle rate exceeds 20 starts/minute On Warm Start Provision On/Off, Delays motor restart after a fault trip, based on calculated motor temperature On TM SmartstartProtection djustment / Description Default Setting Current Phase Unbalance On/Off, djustable: 1-50% current phase unbalance On / 20% Locked Rotor / Stall On/Off, Trips within 0.5 seconds On Out of Calibration Max Time to Start On/Off, Trips after 10 seconds if the FL setting is incorrect (set above calculated FL range), ie. Start current is outside of an acceptable range. (fla setting * 5 < inrush < fla setting * 14). On/Off, Regardless of FL or I 2 t curve, always trip at start if starting current is outside of an acceptable range (inrush / 5) and still decreasing after 10 seconds. On On

TS WIRING DIGRM Dry Inputs Relay Outputs Voltage Inputs SCM PCB Common Shutdown (Perm uto) uto Run (Perm uto) O2 O O1 V4 uto Run V3 Fireman s Override V2 V1 D D2 D1 JSD* Status Common Fault Normally Closed Input Normally Open Input 12-120VC/DC Input 12-120VC/DC Input 1 M 2 ctuator Control Motor 2 Limit Switch 1 Common 24VC, 1 Output JDS* N.O. Input DM X1 *Note 4 24V X2 50V CPT CT 5 Input 120V 208V 240V 480V 575V H1 H4

Submitted Equipment Schedule QTY TG TS PRT# NEM SIZE HP VOLTGE PHSE BCnet Comm w/ Power Metering Modbus Comm w/ Power Metering

3-Pole Contractor Specifications Frame size Type Terminal Type Number of poles Rated operation voltage, Ue Rated insulation voltage, Ui Rated frequency Rated impulse withstand voltage, Uimp Max. operating rate in operating cycles per hour (C3) Mechanical Durability Electrical C-1, Thermal current kw 200/240V Current and power UL rating (50/60Hz) Size and weight kw 380/440V C-3 500/550V kw kw Continuous current Single 110~120V HP Phase 220~240V HP Three Phase MRC MRD uxiliary (standard) Side mount uxiliary Front mount 200~208V HP 220~240V HP 440~480V HP 550~600V HP NEM size Weight lbs Size (WxHxD) in Weight Size (WxHxD) lbs in *Minimum conduct current of auxiliary contactor is DC 17V 5m **10 max, Not motor duty rated. 22F MRC-9B MRC-18B Screw 3 pole 50/60Hz 6kV 1800 operations per hour 15 mil. operations 2.5 mil. operations 25 40 2.5 11 4 9 4 7 4 6 4.5 18 7.5 18a 7.5 13 7.5 9 25 40 0.5 1 1.5 3 2 5 3 7.5 5 10 7.5 15 00 0 0.73 lbs 1.77 x 2.89 x 3.39 in 1.12 lbs 1.77 x 2.89 x 4.63 in 1NO & 1NC M-1 C-2, C-4 40F MRC-32 MRC-50L Screw 3 pole 1000V 50/60Hz 8kV 1800 operations per hour 12 mil. operations 2 mil. operations 50 70 7.5 32 15 32 18.5 28 18.5 20 15 55 22 50 30 43 30 28 50 70 2 3 5 10 7.5 20 10 25 20 40 25 50 1 2 0.88 lbs 1.77 x 3.27 x 3.54 in 1.98 lbs 2.17 x 4.17 x 4.69 in 1.32 lbs 2.65 lbs 1.77 x 3.27 x 4.61 in 2.17 x 4.17 x 5.76 in 1NO & 1NC M-1 C-2, C-4

150F MRC-85L MRC-150L Lug 3 pole 1000V 50/60Hz 6kV 8kV 1800 operations per hour 12 mil. operations 5 mil. operations 2 mil. operations 1 mil. operations 135 210 25 85 150 75 85 150 75 70 100 50 60 135 210 7.5 15 15 25 30 40 40 50 60 100 75 75 3 4 3.53 lbs 2.76 x 5.51 x 5.35 in 5.29 lbs 5.73 lbs 0.15 x 0.24 x 0.20 in 2.76 x 5.51 x 6.78 in 1NO & 1NC M-1 C-2, C-4

MNUL MOTOR STRTER SPECIFICTIONS Frame Size Rated operational current Ie () Magnetic release operating current () 1-phase [HP] (50/60Hz) Branch Motor Protection (UL508) 3-phase [HP] (60Hz) KIC Ratings [k] 115V 230V 200V 230V 460V 575V 240V 480V 600V 32F 63F 100F 0.16 2.1 - - - - - - 100 50 10 0.25 3.3 - - - - - - 100 50 10 0.4 5.2 - - - - - - 100 50 10 0.63 8.2 - - - - - - 100 50 10 1 13 - - - - - 1/2 100 50 10 1.6 20.8-1/10 - - 3/4 3/4 100 50 10 2.5 32.5-1/6 1/2 1/2 1 1.5 100 50 10 4 52 1/8 1/3 3/4 3/4 2 3 100 50 10 6 78 1/4 1/2 1 1.5 3 5 100 50 10 8 104 1/3 1 2 2 5 5 100 50 10 10 130 1/2 1.5 2 3 5 7.5 100 50 10 13 169 1/2 2 3 3 7.5 10 100 50 10 17 221 1 3 3 5 10 15 100 50 10 22 286 1.5 3 5 7.5 15 20 100 30 10 26 338 2 3 7.5 7.5 15 20 100 30 10 32 416 2 5 7.5 10 20 30 100 30 10 40 520 3 7.5 10 10 30 30 100 30 10 10 130 1/2 1.5 2 3 5 7.5 100 50 10 13 169 1/2 2 3 3 7.5 10 100 50 10 17 221 1 3 3 5 10 15 100 50 10 22 286 1.5 3 5 7.5 15 20 100 50 10 26 338 2 3 7.5 7.5 15 20 100 50 10 32 416 2 5 7.5 10 20 30 100 50 10 40 520 3 7.5 10 10 30 30 100 50 10 50 650 3 10 15 15 30 40 100 50 10 63 819 5 10 20 20 40 60 100 50 10 65 8 5 10 20 20 40 60 100 50 10 17 221 1 3 3 5 10 15 100 50 10 22 286 1.5 3 5 7.5 15 20 100 50 10 26 338 2 3 7.5 7.5 15 20 100 50 10 32 416 2 5 7.5 10 20 30 100 50 10 40 520 3 7.5 10 10 30 30 100 50 10 50 650 3 10 15 15 30 40 100 50 10 63 819 5 10 20 20 40 60 100 50 10 75 975 5 15 20 25 50 60 100 50 10 90 1170 7.5 20 25 30 60 75 100 50 10 100 1300 10 20 30 30 75 100 100 50 10 CMS-32HI CMS-63HI CMS-100HI

UL TYPE 1 STNDRD & COMBINTION (FRME SIZE 1) STNDRD & COMBINTION (FRME SIZE 1) E Enclosure Frame Size 1 B C D E TS19 ~ TS150 STNDRD TS19 ~ TS132 COMBINTION 15.7 7.5 6.1 15 5.3 D Enclosure Frame Size 2 B C D E TS185 STNDRD 14 12 6.5 13.3 9.5 Enclosure Frame Size 3 B C D E TS150 ~ TS185 COMBINTION 20 16 10 15.3 11.3 Ø 1.73 Ø 1.12 Ø 0.86 Ø 0.86 C B UL TYPE 3R DIMENSIONS STNDRD (FRME SIZE 1-3) Enclosure Frame Size 1 B C TS3R9 ~ TS3R85 STNDRD 16.3 12.5 7.7 Enclosure Frame Size 2 B C TS3R9 ~ TS3R50 COMBINTION 22.3 15.5 9.7 Enclosure Frame Size 3 B C TS3R85 COMBINTION 32.3 15.5 9.7 Smartstart is a registered trademark of Franklin Control Systems Inc. Do your best work. TCO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360 TCO (Canada), Ltd., 80 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 Telephone: 905/564-9422 Fax: 905/564-9436 Visit our website at: www.taco-hvac.com Printed in US Copyright 2014 TCO, Inc.