Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Similar documents
Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Installation Power Management Unit Battery Cables and Battery Harness

Installation and Operation

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation Guide. Marine Filter SURT023M SURT024M

Broadband PowerShield. CP27U Models. User Manual

Safety and General Information

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

Electrical Installation

Installation and Operation

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

Installation and Operation Manual Smart-UPS Tower 220/230/240 Vac SRC1000ICCIND; SRC1000UXIND

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Installation and Operation

Installation and Operation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Installation and Operation

SUA1000I-IN / SUA1500I-IN 230 VAC

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

Installation and Operation

Operation Manual. Smart-UPS Uninterruptible Power Supply. Rack-Mount 2U. 750/1000/1500 VA 120/230 Vac VA 120 Vac. 100/120/208/230 Vac

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

Installation and Operation

Installation and Operation

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

BroadBand PowerShield. 20 AHr Battery. User Manual

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BR1000-CH

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

APC Smart-UPS RT UXI/UXICH

Operation Manual. Smart-UPS. Uninterruptible Power Supply VA Short-depth Rack-Mount with Lithium-ion batteries. 120 Vac

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

3000VA 120/208/230VAC

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Installation and Operation Manual Back-UPS BX1100CI-CN

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

Installation and Operation Back-UPS BX550CI-CN

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500 VA Short-depth Rack-Mount with Lithium-ion batteries.

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Installation Guide Smart-UPS On-Line Replacement Battery Module APCRBC140/APCRBC140J

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

Power Distribution Units

English. User s Manual. APC Smart-UPS. 2U Rack and Stack External Battery Pack , Revision 1 5/00

Installation and Operation Smart-UPS SUA500PDR

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. 1000/1500 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

Technical Specifications. Symmetra PX kw 208 V

Operation and Maintenance

Power Distribution Units AP9560 & AP9561

CTFRP Series Power Supplies

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation, Maintenance and Warranty Flat Plate Battery

10 Year Limited Warranty

Technical Specifications

Power. On Your Terms.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 60KW, PVI 82KW, PVI 95KW

POWERSTAR INC. Operations / Maintenance Manual Model: PS VA Tower UPS

User Manual Back-UPS BE425M/425M-LM, BN450M/450M-CA

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

MM-AVR UPS Series User s Manual

Quick Start Guide Expansion Battery Pack UPS-OLEBPR-1 UPS-OLEBPR-2

IBM UPS Extend Run Battery Pack Operation and Setup Guide

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

MINISTICK TM UV Germicidal Ultraviolet Light

Installation and Operation

BATTERY PACK. User's Manual

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

USER MANUAL English / Español

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

II DISTRIBUTION & SUBSTATION TYPE C

User s Manual Legend SB825 UPS K

USER GUIDE 1 USER GUIDE

AIS and 40 kva 400 V. Site Preparation and Installation Manual

User s Manual for: UP625 UPS UP825 UPS. ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

Cabling for power, control, and video must be run to the installation site before the mount is installed.

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

BR62 Battery Rack Installation, Operation, & Maintenance Manual

Transcription:

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U SRC96XLBP SRC96XLBP2S English 990-3486B 2/2014

General Information Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate, service or maintain the UPS. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. The addition of this symbol to a Warning or Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. CAUTION CAUTION addresses practices not related to physical injury including certain environmental hazards, potential damage or loss of data. SRC96XLBP / SRC96XLBP2S User Manual 3

Safety Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Adhere to all national and local electrical codes. All wiring must be performed by a qualified electrician. Changes and modifications to this unit not expressly approved by APC could void the warranty. This UPS is intended for indoor use only. Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation. For a UPS with a factory installed power cord, connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords. The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life. The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. The batteries are heavy. Remove the batteries before installing the UPS and external battery packs (XLBPs), in a rack. Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs. Always install peripheral equipment above the UPS in rack-mount configurations. Deenergizing safety The UPS contains internal batteries and may present a shock hazard even when disconnected from the branch circuit (mains). Before installing or servicing the equipment check that the; input circuit breaker is in the OFF position XLBP battery modules are disconnected Battery safety Before installing or replacing the batteries, remove jewelry such as wristwatches and rings. High short circuit current through conductive materials could cause severe burns. Do not dispose of batteries by burning them. The batteries may explode. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes, and may be toxic. SRC96XLBP / SRC96XLBP2S User Manual 4

General information The UPS will recognize as many as 9 external battery packs connected to the UPS. Note: For each XLBP added, increased recharge time will be required. The model and serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel. Always recycle used batteries. Recycle the package materials or save them for reuse. SRC96XLBP / SRC96XLBP2S User Manual 5

Introduction Overview The American Power Conversion (APC ) SRC96XLBP external battery pack (XLBP) connects to an APC Smart-UPS RC. Together these units provide extended protection for electronic equipment (load) from utility power blackouts, brownouts, sags and surges. The UPS and the XLBP together provide continuous power from the batteries until utility power returns to safe levels or the batteries are fully discharged. Inventory Read the Safety Guide before installing the unit. Inspect the battery pack upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the battery pack package contents: External Battery Pack (XLBP) Front bezel Stabilizer/rack-mount brackets XLBP connector cable Hardware supplied listed in table below Literature kit containing: Product documentation Smart-UPS RC User Manuals CD Safety information Warranty information NOTE: The model and serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel. Hardware supplied 8 8 2 Rack-mount configuration: Pan head screws for securing rack-mount brackets to unit Rack-mount configuration: Washers for securing rack-mount brackets to unit Tower configuration: Flat head screws for securing stabilizer brackets unit 2 Rack-mount configuration brackets Tower configuration stabilizer brackets Accessories su0211a Install accessories prior to connecting power to the UPS. Refer to the APC Web site, www.apc.com for available accessories. Optional accessories Additional external battery packs (XLBP) Additional battery strings 4-post rail kit SRC96XLBP / SRC96XLBP2S User Manual 6

Specifications Environmental Specifications Temperature Operating 0 to 40 C (32 to 104 F) This unit is intended for indoor use only. Select a location sturdy enough to handle the weight. Maximum Elevation Humidity Physical Specifications Storage -15 to 30 C (5 to 86 F) charge UPS battery every six months 30 to 70 C (86 to 158 F) charge UPS battery every three months Operating Storage 3,000 m (10,000 ft) 15,000 m (50,000 ft) 0 to 95% relative humidity, non-condensing Weight - Refer to Safety Guide supplied with this unit for lifting guidelines. Do not operate unit where there is excessive dust or temperature or humidity are outside specified limits. Environmental factors impact battery life. High temperatures, poor utility power, and frequent, short duration discharges will shorten battery life. XLBP model SRC96XLBP2S without batteries with two 48 V battery modules SRC96XLBP without batteries with six 48 V battery modules each 48 V battery module 15 kg (32 lbs) 35 kg (76 lbs) 15 kg (32 lbs) 75 kg (164 lbs) 10 kg (22 lbs) Each 96 V battery string consists of two 48 V battery modules. su0265a Maximum number of external battery packs (XLBPs) supported by Smart-UPS RC 10 Combined weights of UPS and all XLBPs installed in a rack must not exceed rack weight limits. Dimensions Length x Width x Height: 48 cm (19 in) x 43 cm (17 in) x 18 cm (7 in) SRC96XLBP / SRC96XLBP2S User Manual 7

Installation Units may vary in appearance from those depicted in this manual. Always place UPS above XLBPs in rack-mount configuration. Connect all battery strings. Failure to do so may cause equipment damage. Refer to Physical Specifications in this manual and the Safety Guide before installing unit. Unit is heavy. Batteries must be removed from unit prior to installation. 1. Remove screws securing battery compartment door. Remove door. 2. Grasp plastic flap attached to battery and pull to remove battery module. Units in tower configuration, remove batteries at top of unit first. su0224a su0223a Tower configuration Install stabilizer brackets 1. Stabilizer brackets must be installed on tower units. 2. Each bracket must be secured with two flat head screws (supplied). NOTE: Screws are pre-installed on left side of unit. These screws must be removed from unit and used to secure stabilizer bracket. Screws for securing stabilizer bracket to right side of unit are included in hardware bag supplied with unit. su212a SRC96XLBP / SRC96XLBP2S User Manual 8

Install and connect batteries This unit is equipped with battery modules. Install batteries into unit beginning with batteries at the bottom. Each string must be connected to battery connectors on chassis. 1. Install batteries. su0225a 2. Connect batteries. 3. Replace battery compartment door and secure door with screws previously removed. x2 x2 x2 su0213a Install bezel 1. Fit three tabs on the bottom inside edge of bezel into slots in chassis. 2. Tip bezel forward. Fit two tabs on top inside edge of bezel into slots in chassis and snap bezel into position. su0216a 2-post rack-mount configuration This unit is intended for installation in a 19, two-post or four-post rack. For details on 4-post rail and rack installation refer to instructions in rail kit. Remove stabilizer brackets if they are installed. Remove four screws that secure each bracket. SRC96XLBP / SRC96XLBP2S User Manual 9

Position unit for mounting in rack The unit is heavy. Use caution when positioning unit. NOTE: The holes for securing rack-mount brackets are plugged. Remove the appropriate plugs prior to installing brackets on the unit. su0214a Install rack-mount brackets Four pan head screws and four washers must be used to secure each rack-mount bracket to unit. x4 x8 su0215a x4 Secure 2-post rack to floor Install units in rack The UPS and XLBPs should be installed at or near bottom of rack. Always place the UPS above XLBPs. Batteries must be removed from units prior to installation in a rack. Two screws (not supplied), must be used to secure each rack-mount bracket to rack. su0217a su0248a SRC96XLBP / SRC96XLBP2S User Manual 10

Install and connect batteries This UPS is equipped with battery modules. Each module must be connected to battery connectors on chassis. 1. Install batteries. 2. Connect internal batteries. 3. Replace battery compartment door and secure door with screws previously removed. su0218a su0226a x2 x2 x2 Install bezel 1. Fit three tabs on inside edge of bezel into slots in chassis. 2. Tip bezel toward chassis. Fit two tabs on inside edge of bezel into slots in chassis and snap bezel into position. su0220a SRC96XLBP / SRC96XLBP2S User Manual 11

Connect XLBPs to UPS Tower configuration UPS XLBP XLBP XLBP su221a Rack-mount configuration UPS XLBP XLBP XLBP su222a There is small cover over each external battery pack connector on the UPS and XLBP. Remove the screw that secures the cover and remove the cover su264a SRC96XLBP / SRC96XLBP2S User Manual 12

Configure UPS parameters This configuration affects the accuracy of the predicted runtime calculations the UPS performs while running on battery power. Refer to the Battery String Configuration tables at the end of this section for detailed instructions. Smart-UPS RC models must be programed to recognize the number of battery strings connected to the UPS. There are four options available for configuring the UPS to recognize the number of battery strings 1. PowerChute Business Edition: Refer to the instructions included with the software 2. Network Management Card (NMC) Web interface: Refer to the instructions included with NMC 3. Network Management Card (NMC) terminal mode: Refer to the instructions below 4. UPS terminal mode Configure UPS connection settings using NMC terminal mode Connect the serial cable to the serial com port on rear side of UPS. 1. Open a terminal program, such as HyperTerminal. From the Desktop, go to: Start, Programs, Accessories, Communication, HyperTerminal 2. Follow the prompts to choose a name and select an icon. If the message, "...must install a modem," click Cancel. 3. Go to File, Properties. Select the COM port that is connected to your UPS. The port settings are: bits per second - 2400 data - bits 8 parity - none stop bit - 1 flow control - none 4. Click OK in each of two windows 5. Press ENTER to initiate connection to UPS. SRC96XLBP / SRC96XLBP2S User Manual 13

Configure the number of battery strings using NMC terminal mode 1. Once the blank terminal window is open: 2. Press ENTER to initiate terminal mode. Press ENTER multiple times, until the prompt User Name: is displayed. Follow the prompts. Type slowly, waiting until each character appears on the screen prior to typing the next character. Network Management Card defaults: User Name: apc Password: apc 3. Press 1 and ENTER to select Device Manager. Select the model by entering the corresponding number, then press ENTER. 4. Press 3 and ENTER to select Configuration. 5. Press 1 and ENTER to select Battery. 6. Press 2 and ENTER to change Battery Settings. 7. Type in the number of battery strings then press ENTER. 8. Press 3 and ENTER to accept the changes. 9. Press ESC five times to return to the main menu. 10. Press 4 and ENTER to log out. SRC96XLBP / SRC96XLBP2S User Manual 14

Configure UPS connection settings using UPS terminal mode Connect the serial cable to the serial port on the back of the UPS. If using USB communication to the UPS, disconnect USB cable prior to connecting serial cable. 1. Open a terminal program, such as HyperTerminal From the Desktop, go to: Start, Programs, Accessories, Communication, HyperTerminal 2. Follow the prompts to choose a name and select an icon. Disregard the message, "...must install a modem," if it is displayed. Click Cancel 3. Go to File, Properties. Select the COM port that is connected to your UPS. The port settings are: bits per second - 2400 data - bits 8 parity - none stop bit - 1 flow control - none 4. Click OK in each of two windows 5. Press ENTER Configure the number of battery strings using UPS terminal mode 1. Once the blank terminal window is open, follow these steps to enter the number of battery strings: NOTE: Letter key commands are case sensitive. Use capital letters when using letter key commands. 2. Press Y. The UPS will respond with SM in the command box. If the UPS does not respond to the Y command, ensure the serial cable is securely connected to the serial port on the UPS. Use only an APC supplied serial cable. 3. When SM appears in the command box press the > key. The UPS will respond with the number of battery strings connected to the UPS. If the UPS has not been previously programmed to recognize the number of battery strings this number will be zero. 4. Use the + or - keys to change the number of battery strings. OK will appear in the command box. 5. Press > key. The number of battery strings will appear in the command box. NOTE: The + or - keys and the > key must be used again to change the number of battery strings from this point in the programming. 6. Press R. The UPS will respond with BYE in the command box. SRC96XLBP / SRC96XLBP2S User Manual 15

Smart-UPS SRC XLI Models - Configure Number of Battery Strings Each 96 V battery string consists of two 48 V battery modules. Count the number of battery strings being used and enter that number. Configuration # of Battery Strings Factory Default for all Models UPS internal battery string 1 SRC96XLBP2S UPS internal battery string + 1 SRC96XLBP2S 2 SRC96XLBP UPS internal battery string + 1 SRC96XLBP2S + 1 SRC004 (1 additional battery string) UPS internal battery string + 1 SRC96XLBP2S + 2 SRC004 (2 additional battery strings) The formula for configuring SRC96XLBP units is as follows: UPS internal battery string + 3 x the number of SRC96XLBP units 3 4 # of battery strings to be entered UPS internal battery string + 1 SRC96XLBP 4 UPS internal battery string + 2 SRC96XLBP units 7 UPS internal battery string + 3 SRC96XLBP units 10 Smart-UPS SRC UXI Models - Configure Number of Battery Strings Each 96 V battery string consists of two 48 V battery modules. Count the number of battery strings being used and enter that number. Configuration # of Battery Strings Factory Default for all Models No UPS internal battery string 0 SRC96XLBP2S 1 SRC96XLBP2S 1 1 SRC96XLBP2S + 1 SRC004 (1 additional battery string) 2 1 SRC96XLBP2S + 2 SRC004 (2 additional battery strings) 3 SRC96XLBP The formula for configuring SRC96XLBP units is as follows: 3 x the number of SRC96XLBP units # of battery strings to be entered 1 SRC96XLBP 3 2 SRC96XLBP units 6 3 SRC96XLBP units 9 SRC96XLBP / SRC96XLBP2S User Manual 16

Contact Information APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact the APC by Schneider Electric Customer Support Center by telephone or e-mail. Local, country specific centers: go to www.apc.com/support/contact for contact information. For information on how to obtain local customer support, contact the APC by Schneider Electric representative or other distributors from whom you purchased your APC by Schneider Electric product. SRC96XLBP / SRC96XLBP2S User Manual 17

Maintenance, Transport, and Service Replace battery modules This UPS has easy-to-replace, hot-swappable battery modules. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipment on during the replacement procedure. Once the batteries are disconnected the connected equipment is not protected from power outages. Refer to the appropriate replacement battery user manual for battery module installation instructions. See your dealer or contact APC at www.apc.com for information on replacement battery modules. Be sure to deliver the spent battery(s) to a recycling facility or ship it to APC in the replacement battery packing material. Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review the Troubleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC by Schneider Electric Customer Support through the APC Web site, www.apc.com. a. Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models. b. Call APC Customer Support and a technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). c. If the unit is under warranty, the repairs are free. d. Service procedures and returns may vary internationally. Refer to the APC Web site for country specific instructions. 3. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty. a. Note: When shipping within the United States, or to the United States always DISCONNECT ONE UPS BATTERY before shipping in compliance with U.S. Department of Transportation (DOT) and IATA regulations. The internal batteries may remain in the UPS. b. Batteries may remain connected in the XBP during shipment. Not all units utilize XLBPs. 4. Write the RMA# provided by Customer Support on the outside of the package. 5. Return the unit by insured, prepaid carrier to the address provided by Customer Support. SRC96XLBP / SRC96XLBP2S User Manual 18

Two-Year Warranty Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the date of purchase. The SEIT obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. Repair or replacement of a defective product or parts thereof does not extend the original warranty period. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. Products may be registered online at warranty.apc.com. SEIT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user s or any third person s misuse, negligence, improper installation, testing, operation or use of the product contrary to SEIT s recommendations or specifications. Further, SEIT shall not be liable for defects resulting from: 1) unauthorized attempts to repair or modify the product, 2) incorrect or inadequate electrical voltage or connection, 3) inappropriate on site operation conditions, 4) Acts of God, 5) exposure to the elements, or 6) theft. In no event shall SEIT have any liability under this warranty for any product where the serial number has been altered, defaced, or removed. EXCEPT AS SET FORTH ABOVE, THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, APPLICABLE TO PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SEIT S RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE SEIT S SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. SEIT WARRANTIES EXTEND ONLY TO ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL SEIT, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, SEIT IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, WHETHER DIRECT OR INDIRECT, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT SEIT S LIABILITY FOR DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE EXCLUDED OR LIMITED BY APPLICABLE LAW. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Customers with warranty claims issues may access the SEIT worldwide customer support network through the SEIT Web site: www.apc.com. Select your country from the country selection drop down menu. Open the Support tab at the top of the web page to obtain information for customer support in your region. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. SRC96XLBP / SRC96XLBP2S User Manual 19

2014 APC by Schneider Electric. APC, the APC logo and APC, the APC logo, and Smart-UPS are owned by Schneider Electric Industries S.A.S. or their affiliated companies. All other trademarks are property of their respective owners. SRC96XLBP / SRC96XLBP2S User Manual 20