UGE-4K Off-Grid Controller OWNER S MANUAL

Similar documents
User Manual. Solar Charge Controller 3KW

CPS Energy Balancer. Version: 1.0

Off Grid Solar Inverter. LVS 50M User Manual

SCC-MPPT Solar Charge Controller

UGE EDDY OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE

User Manual Solar Charge Controller 3KW

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

Solar Charge Controller

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

Battery Power Inverters

Operations Manual Pika Harbor Smart Battery

Advanced Hybrid Wind / Solar Charge Controller. User Manual

OWNER S MANUAL UGE 4KW INSTALLATION OPERATION MAINTENANCE

The Traveler Series: Wanderer

The Traveler Series: Wanderer

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Aurora Wind Interface Box

CTFRP Series Power Supplies

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

The Traveler Series: Adventurer

UGE 9M Owner s Manual. Version 1.2

STONESTAR AUSTRALIA PTY LTD

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

BZ Products Inc. U.S.A.

INSTRUCTION & INSTALLATION

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

Kestrel Interface Module Type 1001 OD

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

USER MANUAL MODEL: 3SPC3.3/106-D72/1100

OASIS-UM-01. User Manual. Inverter/Charger Oasis 6000 Rev 1.0. Oasis 6000 Series MAY 2012 ISSUE 01

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

The Traveler Series TM : Adventurer

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

Power Inverter 400 MW Owner s Manual

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

PV Generation System. Solar Charge Controller SPECIFICATION

Challenger 60 & 70 Tow Series. Installation & User Manual

MASTERsine Inverter PXA Series Installation Guide

LS0512 Solar Charge Controller

230VAC Power Inverter 400W Owner s Manual

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

ResQ 48 & 60. Installation & User Manual

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

OPERATION INSTRUCTIONS

User Manual 1KVA-5KVA INVERTER / CHARGER

Installation manual portable distributors

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Pure Sine Wave Inverter Charger

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

CX-SERIES ADVANCED BATTERY CHARGER

PWM WIND(SOLAR) CONTROLLER USER MANUAL

LIGHTNING PROTECTION UNIT (LPU)

Owner s Manual. PowerVerterDC-to-AC Inverter

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

BOARDWALK STREET LAMP OWNER S MANUAL

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

3KW Off-grid Solar Power System LFP Battery

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Installation and Operating Instructions. Solar System Controller ISC3020

SolarMill SM1-1P, SM1-2P, SM2-3P, SM2-5P, SM2-6P. User manual. Draft. SM1 - Product shown may vary slightly from specific model shipped

Installation and Operating Instructions. Solar System Controller ISC3030

USER S MANUAL SOLAR POWER INVERTER KW-6KW

For additional information, please refer to the Installation/Operation Manual

User Manual. Hybrid PV Inverter. Version: 2.1

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

RM 12V/24V Series Solar Charge Controller User s Manual

Solar System Controller

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

LS0512R Solar Light Controller

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

PerfectSpeed NEMA 48 Pump Motor. With User Interface

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

DC Master 24/ A

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

OWNER S MANUAL Soco TS1200R Soco TS800R

OWNER S MANUAL POWER INVERTER

Enclosed Electric Rotary Screw Compressor Installation Guide

OWNER S MANUAL Soco TS1200R Soco TS800R

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

Installation manual wall-mounted distributor

SANYA STREET LAMP OWNER S MANUAL

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

General Precautions. Personnel Precautions

Transcription:

UGE-4K Off-Grid Controller OWNER S MANUAL

CONTENTS INTRODUCTION... 3 PARTS LIST... 4 SPECIFICATIONS... 5 SAFETY INSTRUCTIONS... 6-7 INSTALLATION... 8 MOUNTING GUIDE... 9 WIRING DIAGRAM... 10 CONTROLLER INTERFACE... 11 WIRING INSTRUCTIONS... 14 SYSTEM START-UP... 15 OPERATION & MAINTENANCE... 16 diversion load operation... 17 LCD DISPLAY... 18 NOTES... 19 TECHNICAL SUPPORT... Back 2

INTRODUCTION Dear UGE-4K Owner, Congratulations on purchasing your Urban Green Energy (UGE) 4kW rated Vertical Axis Wind Turbine (VAWT) and Off Grid Controller and welcome to our family. Enclosed in this manual is information regarding installation, operation and maintenance of the controller. Please read through the manual in its entirety before installing and using your turbine and controller. Under certain circumstances this information may not be fully comprehensive and additional instruction or information may be required in order to successfully and safely complete the installation. These installation and maintenance instructions contain important information for the safe installation and maintenance of the UGE-4K off grid controller. Designed for use with the UGE-4K VAWT, the function of the controller is to take the variable 3-phase AC output from the permanent magnet generator in the wind turbine and convert it to a stable 48 V DC output to charge a battery bank. The controller also manages the turbine so that it performs safely and optimally. The controller should only be installed by qualified personnel such as an employee of a UGE distributor or a certified electrician. Yearly maintenance checks should be performed by qualified personnel. The owner should retain a copy of this manual for reference and to give to future maintenance personnel. This manual should be used in conjunction with turbine installation manual, and the UGE Electrical Supplement. These manuals can be found on the website of the tower and electronics suppliers respectively or can be provided by your UGE distributor. We would like to hear from you with any questions or comments that you have. Please contact us during working hours (Monday-Friday 9:00am to 6:00 pm - US Eastern Time) at: Telephone: +1 (917) 720-5685 Website: www.urbangreenenergy.com Email: techsupport@urbangreenenergy.com Sincerely, 3

PARTS LIST Check the Charge Controller and Parts Please check all the parts based on the following instructions when receiving the package. Contact your local dealer if any part is missing. x1 Controller 325mm 400mm 130mm x1 Diversion Load 185mm 600mm 900mm x3 Cable Gland 4

SPECIFICATIONS Output Voltage... Input Voltage Range (line to line voltage)... Charge Start/Stop Voltage (Iine to line voltage)... Rated Input Current... Maximum Charge Efficiency/MPPT Efficiency... Standby Consumption... Floating Charge Voltage... Over-charge Protection... 57.6V ±1V Discharge Stop Voltage... 46Vdc ±1V Battery Sleep Mode Voltage... 40Vdc ±1V Max. Charge Current... Load Connection... User Interface... 48V 50-230Vrms 50Vrms/45Vrms 20A >85%/>90% <5W 55.2Vdc ±1V 62.5A Dry Contact, Can turn on a DC/AC inverter. LCD status indicators Operating Temperature... -20ºC~40ºC Controller Dimension (L W H) mm... 400 x 325 x 130 Weight... 15kg IP Grade... IP43 Diversion Load Dimension (L W H) mm... 900 x 600 x 185 Weight... 38kg IP Grade... IP43 5

Safety instructions The charge controller shall be installed and operated in accordance with the instructions in this User Manual. The following conventions are used in this guide: WARNING Warnings identify conditions that could cause personal injury, loss of life, or serious damage to the unit or other equipment. CAUTION Warnings identify conditions or practices that could cause personal injury or damage to the unit. 1. The UGE-4K-OGC and supported diversion load should be installed indoors or a dry place that avoids direct sunlight, rain and snow and has good ventilation. Do not leave anything heavy on top of the controller. 2. Keep the controller and battery away from flammables and items that can conduct electricity. 3. Always use the controller with the supported diversion loads. 4. The diversion load cannot be covered by other items and cannot be placed within 300 mm (1 ft) of any flammable, heat sensitive, and/or explosive items. 5. If the controller or turbine behaves abnormally, use the safety brake to stop the wind turbine and disconnect the controller from battery. Do not start the controller until you have contacted UGE tech support and the observed issue is resolved. 6. When the wind speed is high, the temperature of the Diversion Load will be high. 7. If the wind turbine is allowed to spin at high speeds without electrical resistance, such as when the electronics are not completely and properly installed, the turbine may be free-spinning which can lead to extremely dangerous operation. ALLOWING YOUR WIND TURBINE TO FREE SPIN WILL VOID YOUR WARRANTY. Make sure that unless the turbine is fully operational, it is completely stopped either through electrical or mechanical means. 6 8. Check the appearance of the charge controller before installation. Contact your local dealer if any obvious damage is found.

Safety instructions 9. The weight of this controller is around 15kg. Always treat the charge controller with caution during transportation and installation. 10. Do not install the controller in gusty weather conditions. 11. The controller should be mounted vertically against the wall. Do not mount the controller on an angle (see page 9). 12. This controller is for use with the UGE-4K wind turbine only. 13. Connect the wires by following the wiring instrustions on page 12. 14. Follow the wire sizing guide provided in the wire connection diagram (see page 13). 15. It could damage the controller permanently if the controller and battery are not wired properly, e.g. connecting the positive and negative polarities reversely. 16. Wires must be secured tightly to terminals to prevent causing a short or open circuit. 17. Ground the shell of this machine properly to avoid electrical shock. 18. Check whether the battery voltage is within the normal range before starting the controller. 19. Do not connect the controller to batteries that will operate in voltage outside the battery voltage range defined on the specification table, page 5. 20. Do not remove the warranty and/or serial number labels. 21. Keep this manual for your future reference. 7

INSTALLATION Step 1 Check the installation location - minimum 20cm (8 ) clear space around the machine is required for heat dissipation Step 2 Mount the charge controller 8

INSTALLATION Mounting Guide Wall Wall Wall Step 2.1 Put the controller against the wall and mark the locations for drilling (6 holes). Step 2.2 Drill 6 holes and place anchors into those holes. Step 2.3 Fasten screws and secure the controller. CAUTION The mounting method in C is prohibited. A B C 9

14 AWG 10 AWG 10 AWG WIRING DIAGRAM Electrical System Overview Detailed wiring diagrams are available from the UGE website or your UGE distributor. UGE-4K Battery Back-Up Wiring Diagram UGE-4K See Table A See Table A See Table A AC Disconnect Switch #1 3 60 A 240 V AC UGE Off-Grid Controller 18 AWG 18 AWG 18 AWG 18 AWG 10 AWG 10 AWG 18 AWG 10 AWG 10 AWG 18 AWG Fuse 175A Battery Bank 48V 14 AWG See Table B See Table B Magnum MS4448PAE Inverter/ Char ger 120V 10 AWG 10 AWG AC Disconnect Switch #2 30A/240VAC Sub Panel Table A Safety Brake 3 (60 A) Table B Diversion Load Voltage Dr op 1.2 V (5%) Length AWG Length AWG 10m 12 1m 2/0 50m 6 2m 2/0 100m 4 3m 4/0 150m 2 5m 4/0x2 Notes: Wire gauge recommendations based on NEC 310.16 for THHW copper wire below 100 F 1 (A certified electrician shall verify wire gauge meets local electrical code) Each grounded component shall have its own ground wire and connect at a common earth ground 2 3 AC disconnect switch #1 and the safety break should be nonfusible AC Disconnect Switch #3 30A/240VAC Main Panel Meter Grid 10

INSTALLATION Controller Interface Battery Output Terminals Wind Turbine Input Terminals - PE LCD Display Power Switch Communication Interface 11

INSTALLATION BAT+ Terminal Connect to the positive polarity of a battery. L1, L2, and L3 Terminals Connect to the 3-phase AC output of a wind turbine. PE Terminal For grounding. N+ and N- Terminal Block (RS-485) Reserved for RS-485 communication. a1 and a2 Terminal Block (STOP) Communicate external short-circuit brake signal. B+ and B- Terminal Block (BAT) B+ connects to the positive polarity of a battery; B- connects to the negative polarity of a battery. Both of them are for detecting battery voltage. b1 and b2 Terminal Block (SLOW DOWN) Communicate external slow down signal. BAT- Terminal Connect to the negative polarity of a battery. D+ and D- Terminal Block (DISCHARGING) The controller sends the load discharging signals, which can turn on an AC inverter. Maximum current is 8Amp. 12

INSTALLATION Diversion Load Power Switch Shut-Down Switch Slow-Down Switch To Wind Turbine To Controller PE Terminal For grounding. To Batteries Connect to only one 12V or 24V battery. 13

WIRING INSTRUCTIONS This machine includes components carrying high voltage electricity that could potentially cause serious personal injury or even loss of life. The controller shall only be installed by a qualified professional such as a licensed Electrician or UGE distributor. The wiring of the controller shall meet the requirements of the NEC or the local electrical code. Before starting installation, please make sure the input and output power both are shut down to avoid electrical shock. Do not mount the controller above the diversion load, since the heat may damage the controller. 1. Connect the output of your wind turbine to L1, L2, L3 terminals with 14AWG wires. Make sure the wind turbine is fully shut down during wiring. Correct polarity must be observed when connecting the battery cables to the controller. Use caution when connecting the battery leads to avoid shorting them together. 2. Connect BAT(+) lines, 10AWG*2 in RED, to the positive polarity of a battery and BAT(+) terminal. Battery lines should be shorter than 5 meters. (16 0 ) 3. Connect BAT(-) lines, 10AWG*2 in BLACK, to the negative polarity of a battery and BAT(-) terminal. Adding a no fuse breaker (NFB) to the battery circuit is highly recommended. 4. Connect the positive battery detection line, 18AWG in RED to B+ socket and the positive polarity of a battery. 5. Connect the negative battery detection line, 18AWG in BLACK, to B- socket and the negative polarity of a battery. The circuit for battery detection must be independent. DO NOT share the same circuit with other wires. 6. Connect the black brake signal lines to b1 and b2 and the resistor brake disc and red brake signal lines, a1 and a2, to the short-circuit brake disc please see the following chart. 7. Connect the discharge control lines, 14AWG*2 in Orange, from the on/off switch of an AC inverter to D+ and D- sockets. 14

system start-up 1. Engage the safety brake to stop the wind turbine. 2. Check the battery voltage and make sure that the battery detection lines are wired properly. 3. Turn on the battery switch. 4. Turn on the charge controller. 5. Check whether there is LCD initializing message. Make sure that the battery is operating normally. 6. Put AC disconnect #1 in the On position. Disengage the safety brake of the wind turbine. 7. Observe whether the LCD display MPPT charging, if the wind is enough for cut-in. 8. Check the LCD display. Make sure that the system displays no error messages and is operating normally. 15

OPERATION & Maintenance 1. The controller includes the following safety protections to ensure safe and reliable operation of the wind turbine system: a. Wind Turbine Over-speed Protection: when the wind turbine is over-speed, the controller will start to dump exceeding power to external resistor(s) to slow down the speed. If the speed is still too high, the controller will trigger a short circuit brake. b. Input Over-voltage Protection: when the input voltage is too high, the controller will start to dump exceeding power to resistor(s) to slow down the wind turbine. c. Output Over-power Protection: when the output current is too high, the controller will start to dump exceeding power to resistor(s) to slow down the wind turbine. d. Battery Over-charge Protection: when the battery voltage is higher than the floating charge voltage, the controller will start to dump exceeding power to resistor(s) to slow down the wind turbine. In other words, the controller will stop the MPPT function and enter a battery protection mode to protect the battery when the battery is full. e. High Voltage Protection: the controller can protect itself from being damaged by certain high voltage pulse, such as a lightning strike. 2. The charge controller requires little maintenance if it is used properly. Please periodically clean the controller surface with a cloth. In addition, please keep the wind turbine, generator, and battery in a good condition to ensure the whole system can function well. 3. Check the operating status of the controller and diversion load box regularly. Please pay attention to the warning messages and follow the instructions labeled on the charge controller. 4. Contact UGE Technical Support if the controller display does not function normally. See back cover for Technical Support contact information. Do not try to repair the controller by yourself. This machine includes components carrying high voltage electricity that could potentially cause serious personal injury or even loss of life. Only a qualified professional such as a licensed Electrician or UGE distributor should repair or replace parts. The safety brake must be applied before all maintenance procedures with the turbine. Allowing the turbine to free spin without a brake can cause severe damage to the turbine, and will void the warranty. Keep this manual for your future reference. 16

DIVERSION LOAD OPERATION Standard Operation 1. Normal Setup: Power Switch: On Manual Shut-Down Switch: Off Manual Slow-Down Switch: Off 2. Manual shut-down procedure: Step 1: Power Switch: On Step 2: Manual Slow-Down Switch (S3) = On (Slow down first) Step 3: Manual Shut-Down Switch (S2) = On (Shut down) Switch Configurations 1. Power Switch: On: Standard Operating Mode: The diversion load is on. Off: The diversion load will shut down. Should not be in this position during normal operation. 2. Manual Slow-Down Switch: On: The wind turbine will slow down. Off: The Wind Charge Controller will control the braking signal automatically. 3. Manual Shut-Down Switch: On: The wind turbine will stop spinning immediately. If the wind turbine is spinning, please engage the Slow-Down Switch first. Off: The Wind Charge Controller will control the braking signal automatically. 4. Advanced independent braking feature: As a backup safety feature, the control box can slow the wind turbine on its own. 17

LCD DISPLAY WG Braking... N= rpm _m s MPPT Charging... Rotr spd= rpm Braking Status R.P.M. of the Wind Generator MPPT Charging... OUT:. _V. _A MPPT Charging... IN: V. _A Output Voltage and Current Input Voltage and Current 18

NOTES 19

TECHNICAL SUPPORT If your product requires troubleshooting or warranty service, contact your merchant. If you are unable to contact your merchant, or the merchant is unable to provide service, contact UGE directly at: Urban Green Energy 330 West 38th Street Suite 1103 New York, NY 10018 Tech. Support Phone: +1 (917) 720-5685 Email: techsupport@urbangreenenergy.com This manual is an adaptation of the Power General WCHG-483000 installation manual for this product and is meant to be used as a guideline only. For specific details, refer to the Power General manual. A certified electrician or the project electrician is responsible for verifying that the controller installation meets local elelctrical code. UGE provides this manual as a guideline and is not responsible for any errors which may occur due to the use of this manual. 20 March 2012 Copyright Urban Green Energy, Inc. 2012