Operating manual. General operating instructions: Assembly, commissioning and maintenance B

Similar documents
Flow control valve type SJ

Releasable check valve type RH

Releasable check valve type HRP

Shut-off valve type AVT and AVM

Throttle valve type ED, throttle restrictor check valve type RD and RDF

Throttle valve and throttle check valve type CQ, CQR and CQV

Throttle valve and shut-off valve type CAV

Starting up hydraulic systems

Check valve type ER and EK

Flow divider, type TQ

Check valve type ER and EK

Valve bank type BNG. Product documentation. Manifold mounting Operating pressure p max : Flow rate Q max : 400 bar 60 lpm D 7788 BNG

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

Releasable twin check valve type DRH

Pump element type MPE and PE for radial piston pumps

Direct current compact hydraulic power pack type NPC

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Variable displacement axial piston pump type V80M

Valve bank (directional seated valve) type BVH

Connection blocks type AX, ASX, AVX and APX

Check valve type ER and EK

Angle seat valve with diaphragm actuator VZXA-...-M

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Operating manual Separator

Installation manual wall-mounted distributor

OTTO HYDRAULICS GmbH & Co KG SYSTEME UND KOMPONENTEN FÜR ÖLHYDRAULISCHE ANTRIEBE UND STEUERUNGEN SIEMENSSTRASSE 12/ FRIEDRICHSHAFEN

Ball valve for pipeline systems

Angle seat valve with piston actuator VZXA-...-K

Operating Instructions for Elevator Buffers type LP

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Water pumps. Typical damage patterns and their causes

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52.

Free Float Air Trap G8

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

Routine Compressor Maintenance

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Declaration of Conformity as per Directive 97/23/EC

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Angle seat valve with piston actuator VZXA-...-K

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD

Internal Gear Pumps Installation Manual

Spare parts list Inline filter FLND switchable

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Maintenance Information

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

Directional spool valves type SWPN

Installation manual portable distributors

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Manufacturer Kakogawa, Japan DC5S

Installation, Operation, and Maintenance Manual

These installation and maintenance instructions must be read in full and completely understood before the installation!

Butterfly valves Figure 56 Installation & Maintenance Instructions

Svendborg Conveyor Brake Maintenance

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps

Before you go through this booklet, we request you to go through the following general instruction before commissioning your hydraulic systems.

Automatic Back-Flushing Filter AutoFilt RF9.

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Cooling System. Table of Contents

Operating instructions Accu Jet

Membranventil Kunststoff, DN Diaphragm Valve Plastic, DN GEMÜ 600 Antriebsgröße Code 2-4 Actuator size Code 2-4

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

MECHANICAL CYLINDERS Operating Instructions

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Assembly and Maintenance Manual Type ASNU

Instruction Manual. Maximum Operating Pressure 510 bar

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

A408 GB. Pneumatic oil and diesel pumps 1:1

Before equipment use, please read this operation manual carefully. Serial Number: Date Purchased:

Quarter turn actuator DAPS..R..-F..

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

Variable displacement axial piston pump type V60N

Pneumatic grease pump 50:1 and grease supply system

Exchange of rollers from the XTS-Mover

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Instruction Manual. Unique 7000 Series Aseptic - Manually Operated ESE02421-ENUS Original manual

Operating manual Vacuum Breaker

Troubleshooting the Transmission Hydraulic System

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Instruction manual for rescue equipment. Hydraulic power units

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23

Unique 7000 Series Valve - Standard and Reverse Acting

TC Series Cooling Systems

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Operating instructions Form no safety definitions

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Assembly and Maintenance Manual Type AS

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Transcription:

Operating manual General operating instructions: Assembly, commissioning and maintenance B 5488 09-2016-2.0

Contents 1 General operating instructions for assembly, commissioning and maintenance... 3 1.1 General information and the purpose of this document...3 2 Assembly... 3 2.1 Basic preparation...3 2.2 Preparing for assembly and commissioning...4 3 Initial operation...5 3.1 First test run...5 3.2 Initial operation of complex systems or systems with several simultaneous consumer movements... 6 3.3 Most frequent mistakes during initial operation... 7 4 Maintenance and repair... 8 4.1 Inspection...9 4.2 Maintenance... 10 4.3 Repair...11 5 Disassembly and disposal...12 6 Storing hydraulic uids and hydraulic components... 13 7 Con-current documents... 14 2 09-2016-2.0 - B 5488 www.hawe.com 2016

1 General operating instructions for assembly, commissioning and maintenance 1.1 General information and the purpose of this document This operating and maintenance manual provides only general information regarding the assembly, operation and maintenance of systems and components from HAWE Hydraulik SE. The documentation for individual components and the operating and maintenance manual of the speci c complete system must also always be observed. Proper operation and maintenance substantially increases the service life of hydraulic components and systems and significantly contributes to functional reliability. Supplementary applicable guidelines VDI 3027 "Initial operation and maintenance of oil-hydraulic systems" DIN 24346 "Hydraulic systems" DIN EN ISO 4413 "Hydraulic uid power - General rules and safety requirements for systems and their components" 2 Assembly 2.1 Basic preparation Check stored parts for completeness and possible shipping damages. Check that the delivered components are complete and undamaged. Note Dirt must not enter the power pack. Otherwise, the power pack may be damaged. Ensure the power pack is completely clean. Keep all pipes, hose lines, ttings and couplings of the power pack clean. Carry out all work on the power pack in a clean environment. Clean hands and clothing before working on the power pack. Before installation: Clean the outer surfaces of the power pack (tank, lines, motor etc.) and then continue to keep them clean. Carry out the assembly in a clean workspace. Dirt or moisture must not enter the hydraulic uid. Always close open connections with a protective cover, even if the connections are only open for a short time. www.hawe.com 2016 09-2016-2.0 - B 5488 3

2.2 Preparing for assembly and commissioning Always use the standard lifting lugs and transport equipment. Valve contact surfaces must be level. For angeable valves, the contact surface must also be clean and free of scratches and correspond to the prescribed surface nish. Tighten the fastening screws equally with the speci ed torque. This prevents undesirable tension and subsequent malfunctions. Select pipes, hoses and ttings/ anges in the correct pressure stage (wall thickness, material). Only use a seamless precision steel tube. Observe the installation information from the tting manufacturer. This prevents external leakages on the connection points. Hemp or Te on (PTFE) tape must not be used! State of the art, widely available assembly material makes hemp or Te on (PTFE) tape definitely superfluous! Route pipe and hose lines correctly and according to the applicable standards. Avoid mechanical tension or cha ng of the hoses on other components without fail. Fill oil tank with the correct hydraulic uid (also see Oil recommendations: D 5488/1). Ensure that the hydraulic uid corresponds to the required cleanliness level. Note The system and all components, in particular the seals, must be suitable for the hydraulic uid. The absolute neness of the ller lter must be at least the same as the lter installed in the system. Fill the hydraulic uid through the system lter or a mobile lter station, up to the top marking of the ll level monitor. Charging hydraulic accumulators Note Hydraulic accumulators are subject to the safety regulations that apply locally to the installation location. Use only nitrogen as lling gas. Depressurise the system on the oil side. Fill with nitrogen until the gas pre-load pressure p0 speci ed in the documentation is reached. Installation types for accumulators: Diaphragm accumulators can be installed as desired. Bladder accumulators are preferably installed vertically with an oil connection underneath. Piston type accumulators are almost always installed vertically. Danger Risk to life due to hydraulic accumulators potentially exploding if they are not lled correctly! Risk of serious injury or death. The maximum operating pressure, lling pressure and temperature range of the hydraulic accumulator must be suitable for the operating conditions. Fill hydraulic accumulators only with N 2 (nitrogen). Only use suitable lling and testing devices. Connect the drive motor to the power supply. Connect electromagnetic valves and sensors to the power supply. 4 09-2016-2.0 - B 5488 www.hawe.com 2016

3 Initial operation 3.1 First test run The test run may only be carried out by technically quali ed personnel from the machine manufacturer or by maintenance personnel. Release the pressure on all pressure control valves (pressure reducing and pressure-limiting valves) and also the pressure controllers of variable pumps and set to the minimum value. Sealed TÜV pressure-limiting valves are exempt. Open shut-off valves and throttle valves as wide as possible. Brie y start the drive motor to verify that the rotating direction is conforming the specification of the pump. Verify that all valves are in their desired position (acc. to the hydraulic circuit plan). Fill pump housing with hydraulic uid. This prevents bearings and power unit components from running dry. (also see the relevant operating and maintenance manual for the pump). Brie y start the power pack and observe that no unusual noise can be detected. Bleed the hydraulic system: Carefully loosen top screw ttings or dedicated bleed screws, but do not remove them. The bleeding process is complete when the hydraulic uid ows out without bubbles. At this point, re-tighten ttings/screws. Also switch the pump motor on and off again several times. Rinse the system: Perform all the functions of the hydraulic system a few times without load until the they run smoothly and in the pre-de ned time. Once the operating oil temperature has been reached (at least 40 C), check the system under load. To do this, slowly raise the pressure to the set point while constantly monitoring the pressure gauge. Check the surface temperature of pumps and motors (max. 80 C). Monitor hydraulic uid level and re- ll hydraulic uid if required. Check proper setting/function of all safety and pressure limiting valves either by external load or abrupt deceleration of the application. Check for external leaks. Switch off drive. Check and retighten all mounting screws, ttings etc. with the speci ed torque, even if no leaks are visible. Danger Risk to life due to hydraulic accumulators potentially exploding if they are not lled correctly! Risk of serious injury or death. The maximum operating pressure, lling pressure and temperature range of the hydraulic accumulator must be suitable for the operating conditions. Fill hydraulic accumulators only with N 2 (nitrogen). Only use suitable lling and testing devices. Caution Risk of injury due to pressurised parts. Risk of minor injury. Release the pressure in the system before re-tightening screws and valves. www.hawe.com 2016 09-2016-2.0 - B 5488 5

Questions for the next work steps The following questions must be answered with "no" before the next steps: Have the changing pressure loads indicated inadequate tting of pipelines? Have the changing loads resulted in cha ng of the hose lines on other components? Functional check of the complete system: Compare measured values with the standard or maximum permissible values. Check the reached adjustment and rotation speeds against the targets. Re-adjust the control units if required. The following observations point to inadequate bleeding. Repeat the bleeding process in the following cases: Jerky movements or adjustment speeds are not reached. Foam forms on the surface of the hydraulic uid. Check the operating temperature regularly. 3.2 Initial operation of complex systems or systems with several simultaneous consumer movements When commissioning such systems, it is often necessary to take multiple measurements (e.g. multiple pressures, electrical signals, routes, speeds, ow rates etc.) at different measuring points simultaneously. The mutual in uence or the targeted interaction of the consumers should be monitored with this. These measurements and therefore optimisation cannot generally be carried out with conventional measurement devices (such as pressure gauges, thermometers, electrical multimeters etc.). This applies to systems such as machine tools, crane controls, machines with electro-hydraulic controls and others. HAWE Hydraulik therefore recommends contacting the service department of the system manufacturer. Warning Danger of injury and material damage due to incorrect installation, operation and maintenance! Risk of serious injury or death. Ensure that the power pack is installed, operated and maintained by quali ed and trained specialist personnel only. Before staff work on the power pack, ensure they are trained and instructed by the manufacturer. Please note that incorrect installation, operation and maintenance may result in material damage. 6 09-2016-2.0 - B 5488 www.hawe.com 2016

3.3 Most frequent mistakes during initial operation Insufficient cleanliness during assembly. Valves are strained or tted with the incorrect torque. The hydraulic uid was not ltered or the required cleanliness level was not complied with. The hydraulic system was not checked before commissioning. Hydraulic uid has leaked during subsequent conversion. System parts were not bled or were insufficiently bled. Pressure-limiting and safety valves were set too closely above the operation pressure (closing hysteresis is not observed). The ow direction that is sometimes predetermined in valves was not complied with. Loud mechanical noise, particularly from the pump, was ignored. Possible causes of mechanical noise: Cavitation Leaking suction line Pump and motor incorrectly adjusted The switching hysteresis of mechanical pressure switches that is dictated by design was not considered when setting the pressure switch. Hydraulic pump housing and hydraulic motor housing were not lled with hydraulic uid before commissioning. The technical adjustment values were not documented or the correct standard values are missing. Adjusting spindles were not secured/locked or sealed. Insufficient qualification of staff. www.hawe.com 2016 09-2016-2.0 - B 5488 7

4 Maintenance and repair HAWE power packs and components have been designed to enable fault-free operation over a long service life. However, regular maintenance will need to be planned and carried out, taking into account the length of time for which the power packs and components are switched on, their switching frequency, the potential consequences in the event of a failure and the availability or guarantee time required. Instructions in addition to the general operating and maintenance manual must also be observed (see Chapter 7, "Con-current documents"). The standard DIN 31051 de nes the following tasks under the generic term "maintenance": Inspection Identifying and assessing the actual status. Clarifying how and why the depletion of the so-called wear reserve is continuing. Maintenance Preserving the target status. Taking precautions to ensure that the depletion of the wear reserve is kept as low as possible during continuous operation through appropriate maintenance work. Repair Re-establishing the target status. Rectifying functional restrictions, malfunctions and replenishing the wear reserve. Inspection, maintenance and repair work often overlap in practice and are not so strictly separated as de ned in accordance with standards. 8 09-2016-2.0 - B 5488 www.hawe.com 2016

4.1 Inspection Regular tasks to be carried out are recorded in the so-called maintenance or inspection lists. In this way, employees with different qualifications can carry out individual tasks reliably. The most important tasks for the inspection: Checking the hydraulic uid level in the tank. Checking the cleanliness/condition of the hydraulic uid. Note A check without a laboratory test is only able to provide a rough estimate of the condition of the hydraulic uid. The following indicate that the condition is poor: Milky cloudiness in the hydraulic uid. Darker appearance than when it was lled. Sediment in the uid reservoir. A smell of burnt oil. Checking the visual clogging indicators of lters or differential pressure switches during operation (if present). Checking the hydraulic uid temperature during operation (usually <60 C, max. 80 C). Checking pressures and adjustment speeds. Checking for external leakage (visual check). Checking the pipeline system for loose ttings and hoses for cha ng. Caution Risk of injury from damaged pipes and hose lines. Risk of cuts. Immediately replace any damaged pipes and hose lines. Warning Slip hazard due to escaping hydraulic uid puddles! Risk of minor or serious injury. Remove hydraulic uid using suitable binding agents. Dispose of binding agents according to local regulations. Checking hydraulic accumulators (visual check). Checking the electrical supply lines of the motor, solenoid valves, sensors, pressure switches etc. (visual check). www.hawe.com 2016 09-2016-2.0 - B 5488 9

4.2 Maintenance An overview of inspection and maintenance intervals can be taken from table 1 in Chapter 7, "Con-current documents". The most important maintenance work Checking hydraulic uid and replacing if necessary. The permissible period of use depends on the operating conditions (e.g. tank size, number of throttle points), but particularly on the average operating temperature. 80 C should be the maximum value (lower for hydraulic uids with water content) (+10K equates to a service life reduction of 50%). Mixing different types of uids may lead to undesirable chemical reactions such as sludge formation, resinification or similar. If the hydraulic uid needs to be changed, it is essential to contact the oil manufacturer and to ush the system thoroughly. Completely drain the hydraulic uid at operating temperature and dispose of it properly. Heavily aged or contaminated system uid is not improved when new hydraulic uid is added. Only ll via the system lters or via lters that have at least the same deposition rate as the installed lters. Take oil samples regularly and test them for particle type, size and quantity. Document values. Checking the settings for system and control pressure. Documenting any pressure corrections. If the power pack needs to be readjusted repeatedly in order to get back to the intended pressure: indication of the wear of the pressure valve. Checking the pressure control valve and replacing if necessary. Looking for leakages in the pipe system. Caution Risk of injury due to pressurised parts. Risk of minor injury. Release the pressure in the system before re-tightening screws and valves. Note Leakages at connection points which are sealed with deformable seals (O-rings, moulded sealing rings etc.) cannot usually be resolved by re-tightening (observe the permissible torque) because in such cases these sealing elements are either destroyed or hardened. The sealing elements must be replaced with new ones. Checking the function of control and monitoring elements (pressure gauges, pressure switches, etc.). Caution Danger of burning due to hot metal surfaces on the power pack, particularly on the power pack tank, electric motor, valve blocks and valves. Risk of minor injury. Wear protective gloves. Allow the power pack to cool down before touching it. Disconnect the power supply before touching the heating element. 10 09-2016-2.0 - B 5488 www.hawe.com 2016

4.3 Repair Identifying and locating causes of damage Troubleshooting Successful troubleshooting within a hydraulic system is largely based on detailed knowledge of the assembly, the operation and the interaction of the individual components. All essential documentation les should be available. The ability to read hydraulic or electro-hydraulic schematics is generally required in order to understand these les. Correctly functioning measurement devices (thermometer, electrical multimeter, industrial stethoscope, stopwatch, tachometer etc.) are indispensable tools. Corrective action Ensure the highest degree of cleanliness during all work. Clean the workspace before loosening ttings. Defective devices should generally not be repaired on site because usually the tool required will not be available or the required level of cleanliness will not be obtained in order for the repairs to be carried out properly. The aim should be to only replace entire components on site, or at least parts that can be tested individually. As a result downtimes are minimised, troubleshooting is simpli ed and hydraulic uid losses are kept to a minimum. It is important to clarify whether the malfunction of the repaired/replaced component could result in the risk of damage occurring in the hydraulic circuit due to increased metal abrasion or even debris. After the actual damage is recti ed, it should be clari ed whether there was a primary cause for the malfunction (e.g. lter neness was too low, inappropriate maintenance intervals etc.). This primary cause must then be resolved. www.hawe.com 2016 09-2016-2.0 - B 5488 11

5 Disassembly and disposal Disassembly and disposal of the power pack may be carried out by quali ed staff only. Decommissioning the power pack as old equipment: Comply with the currently applicable laws and regulations regarding disposal. Caution Danger of burning due to hot metal surfaces on the power pack, particularly on the power pack tank, electric motor, valve blocks and valves. Risk of minor injury. Wear protective gloves. Allow the power pack to cool down before touching it. Disconnect the power supply before touching the heating element. Note recommends the following for disposal of power packs by refuse type: Mixed scrap: valve bank, valve control, control block Electronic waste: switch box, pump housing with motor, heating element Scrap iron: Metal frame, accumulator (unpressurised), gear pump Waste oil: hydraulic uid If the components cannot be disposed of by separate refuse types, the entire power pack may be disposed of as mixed scrap. However, the hydraulic uid must be drained beforehand. Dispose of the hydraulic uid as waste oil. Note Do not release hydraulic uid into the environment. Collect cleaning, operating and lubrication uids and consumable materials in suitable containers and dispose of them according to local regulations. 12 09-2016-2.0 - B 5488 www.hawe.com 2016

6 Storing hydraulic uids and hydraulic components Storing hydraulic uids and hydraulic components Storage conditions for hydraulic components depend primarily on the following factors: seals utilised, moistening with oil during the factory functional test The storability of rubber materials is generally in uenced by the following factors: Warmth, light, humidity, oxygen, ozone As far as possible, components should be de-energised and without deformation when stored. A storage temperature range of 15 to 20 C is optimum. Relative humidity approx. 65% (+-10%). Exposure to direct sunlight or a light source with strong UV rays should be avoided. Ozone-producing equipment (electric motors, high-voltage equipment) among other things must not be present in the storage room. If seals are packaged in plastic bags, these should not contain any plasticisers and, if necessary, should be impermeable to UV light. Details on storage of elastomers are also available in the following standards: DIN 7716, MIL-HDBK-695, SAE ARP5316D, SAE AS 1933, DIN 9088. Hydraulic uids can be stored for an unlimited period in sealed containers supplied by the manufacturer, as no chemical reactions take place. The presence of atmospheric oxygen, dust and moisture can lead to more or less rapid oxidation and resinification, depending on the type of oil and its additives. A dark room with virtually constant temperature and humidity is recommended for storage of hydraulic components. The parts should be kept in a plastic bag to protect them from dust and continuous air exchange. A functional test (manual override, dry switching) should be carried out at least once a year to ensure operation. Safety-related components: A six-monthly functional test on site and a regular factory inspection including seal replacement every 2 years. When the hydraulic components are stored as described above, the risk of corrosion is low. Most external parts of HAWE components are coated with a protective layer (galvanised, nitrided) and moistened with oil. www.hawe.com 2016 09-2016-2.0 - B 5488 13

7 Con-current documents Oil recommendations: D 5488/1 Speci c product documentations e.g. product related service notes, hydraulic circuit plans, technical drawings, test protocols, technical supplements etc. Table 1 Inspection- and maintenance intervals Hydraulic uid During start daily or permanent 1 week or 40 h During standard operation always after 3 months or 500 h Filling level o o Service temperature o o 6 months or 1000 h Condition ( uid sample) o o 1 year or 2000 h 2 year or 4000 h Change o o 1) o 1) Filter Replacement/inspection of lters without clogging indicator o o o 1) Monitoring of the clogging indicator o o Cleaning of the breather lter o o 1) Replacement of the drying lters (silica gel) Accumulator Check gas pre-load pressure p0, check mounting Set values Pressure-, ow valves, pump controllers, monitoring devices Cooler o o o 1) o o o 1) Clean uid/air-cooler o o 1) o o 1) Clean uid/water-cooler o o 1) Other controls External leaks o o o o 1) Contamination Damages o o o 1) Noise o o o o 1) Test equipment o o 1) o 1) Inspection or maintenance intervals for operation < 500 h / year 14 09-2016-2.0 - B 5488 www.hawe.com 2016

Further information HAWE Hydraulik supplies compact, energy-saving and durable hydraulic components and systems. These are characterised by the following, for example: Consistent use of steel (no parts exposed to pressure made of cast-iron or aluminium) Components designed for high pressures Compact design (requiring minimal space) Zero leakage or controlled minimal leakage Approved for special operating conditions (e.g. ATEX) Further information on HAWE Hydraulik and our range of products can be found at: HAWE Hydraulik SE - www.hawe.com. HAWE global contact person: Addresses of of ces and representatives (international). 09-2016-2.0 - B 5488 HAWE Hydraulik SE Streitfeldstraße 25 81673 München Postfach 80 08 04 81608 München Germany Tel +49 89 379100-1000 Fax +49 89 379100-9100 info@hawe.com www.hawe.com