INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

Similar documents
TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS

TURBO PRESSURE BLOWERS

turbo pressure blowers

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Defining Innovation. backward curved FANs

Twin City Fan & Blower

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011

CAST ALUMINUM PRESSURE BLOWERS

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Twin City Fan & Blower

TURNING AIR INTO SOLUTIONS. HIGH EFFICIENCY INDUSTRIAL BACKWARD CURVED FANS MODEL HIB

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Turbo Pressure Blowers

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

FIXED PITCH PROPELLER FANS

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

BACKWARD CURVED HIGH PRESSURE FANS

forward curved inline duct blowers

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Air Moving Solutions. AIRFOIL fans

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOGUE M950 FEBRUARY 2013

Twin City Fan & Blower

Air Moving Solutions. MODULAR plenum fans

Turning Air Into Solutions. CAST IRON BLOWERS MODEL CIW

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

Twin City Fan & Blower

HIGH VELOCITY FUME EXHAUST FANS

TURBO PRESSURE BLOWERS

COMMERCIAL DUTY PLENUM FANS

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

& 12" 96" / TABD CATALOG

Centrifugal Utility Fans - SFD/SFB

DIrect drive exhaust & supply panel fans

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

TURNING AIR INTO SOLUTIONS. INDUSTRIAL FANS RBA RBO RBR RBW RBP

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Good Enough Never Is. Plug Fan SERIES 12

Twin City Fan & Blower

LOW PRESSURE MIXED FLOW FANS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Twin City Fan & Blower

BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven

Air Moving Solutions. AEROFOIL fans

CEILING & INLINE/CABINET VENTILATORS

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

TUBULAR CENTRIFUGAL INLINE FANS

Air Moving Solutions. AEROFOIL fans

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

ceiling & inline/cabinet ventilators

Defining Innovation. DIRECT DRIVE backward inclined fans TYPE TCBI

Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Cast Aluminum Pressure Blowers

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

BACKWARD INCLINED FANS

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

TYPE HP. Static pressures to 128 WG Capacities to 20,000 CFM Temperatures to 600 F. PRESSURE BLOWERS Static pressures to 58 WG Capacities to 5,200 CFM

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Twin City Fan & Blower

Air Moving Solutions. axifan adjustable blade vaneaxial fans

AXIFAN VANEAXIAL FANS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

VANEAXIAL & TUBEAXIAL FANS

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust)

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Tubular Centrifugal Fans

MANCOOLERS. Macheta Airfoil Propeller Model UM / PUM / M39 / STL. Utility Mancooler Model UM. Pedestal Mount Mancooler Model PUM

BACKWARD INCLINED fans

Mixed Flow Inline Fan, Model MFSI

SQUARE INLINE CENTRIFUGAL FANS

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

MIXED FLOW FANS. Twin City Fan QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat)

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

The Industrial Choice. INDUSTRIAL FANS MHO / MHR / MHA / MHW / MHP CLASS 22 & 32

Centrifugal Fans - M41

ARRANGEMENT 4/4F/4H/4V SINGLE-WIDTH ACOUSTAFOIL/PLR FANS

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MIXED FLOW FANS QSL QSLR QSLSH CATALOG 1060 MARCH 2017

Transcription:

Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS PRESSURE BLOWERS MODEL PBW CATALOG 120 APRIL WWW.TCF.COM

PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high static pressures, yet stable operation throughout its operating range. The PBW is ideal for the handling of long, stringy, or fibrous materials. Typical Applications Textile fiber stripping Material conveying Product drying Air pollution control High pressure industrialprocess systems Glass blowing Combustion air Fluid bed aeration Scrubber exhaust Gas boosting Arrangement 4 with Punched Outlet Flange Capabilities Static pressures to 0" w.g. Airflow capabilities to 7,700 CFM High temperature applications to 0 F Housing Construction Fans come standard with heavy-gauge, continuously welded steel housings and welded pedestals for rugged, heavy-duty, long-term service. Housings are reversible and rotatable in the field for easy retrofit and new applications. Fans come standard with a punched inlet flange, round punched flanged outlet connection and standard shaft seal. PBW Wheel Wheel The PBW offers an all-welded, reversible, radial backplate wheel of constructed in Corten steel. PBW wheels are ideal for material handling applications. Twin City Fan For complete product performance, drawings and available accessories, download our Fan Selector program at tcf.com. 2 TWIN CITY FAN - CATALOG 120

ARRANGEMENTS Arrangement 1 (Belt Driven) The fan wheel on an Arrangement 1 is overhung on the shaft, i.e., mounted at the end of the shaft. The motor can be mounted in any of the four AMCA standard motor positions, W, X, Y or Z. The two fan bearings are mounted on the bearing pedestal, out of the airstream. Arrangement 4 (Direct Drive) The fan wheel on an Arrangement 4 is mounted directly on the motor shaft with the motor mounted on a pedestal. An Arrangement 4 offers a compact, low maintenance design, as there are no fan bearings, fan shaft or drive parts to maintain. Arrangement 4 fans are limited to 180 F. Arrangement 8 (Direct Drive) Arrangement 8 is a modified version of Arrangement 1 used for direct drive. The Arrangement 1 bearing pedestal is extended to accommodate the motor. A flexible coupling connects the fan and motor shaft. Consult factory for more information. Arrangement 1 Arrangement 4 Arrangement (Belt Driven) Arrangement is a belt driven fan with a motor slide base mounted on the side of the bearing pedestal. This arrangement permits the unit to ship as a complete assembly with the motor and drive mounted. Typically, the motor is mounted on the left side of the pedestal for CW rotation fans and on the right side for CCW rotation fans. Arrangement 8 Arrangement OPTIONAL CONSTRUCTION Spark Resistant Construction Fan applications may involve the handling of fumes or vapors. Such applications require careful consideration by the system designer to insure the safe handling of such gases. Twin City Fan & Blower offers the following classifications of spark resistant construction per AMCA Standard -01-8. It is the specifier s or the user s responsibility to specify the type of spark resistant construction with full recognition of the potential hazards and the degree of protection required. High Temperature Construction 1 to 0 F - Package includes shaft cooler with guard, high temperature grease, and standard enamel paint. For Arrangement fans, a motor heat shield is included. Type B - The fan shall have a nonferrous wheel and nonferrous rub ring about the opening through which the shaft passes usually aluminum wheel and rub ring and limited to 0 F. Consult factory for availability. Type C - The fan is constructed so that a shift of the wheel or shaft will not permit two ferrous parts of the fan to rub or strike. Shaft Cooler & Safety Guard WWW.TCF.COM 3

OPTIONS/ACCESSORIES Customer Ductwork Bolted Access Door 2 4 Customer Ductwork 1 3 7 1 Flanged Inlet Punched to ANSI 1/0 hole pattern for bolted connection is standard. Access Door Heavy duty bolted panel provides access for wheel inspection. 2 Flanged Outlet Punched to ANSI 1/0 hole pattern for bolted connection is standard. 7 Motor Slide Base for positioning motors and adjust. 3 4 Drain Standard 3 4" NPT half coupling located at the lowest point of the housing. Available with or without plug. Shaft and Bearing Guard Sheet metal guards cover shaft and bearings and come with extended lube lines to a common point outside of the guard. Painted safety yellow. Belt Guard OSHA style to enclose the V-belt drive. Painted safety yellow. Other Accessories Include: Inlet Bell with Inlet Screen Belt Guard; Quick Access Shaft Guard (Bearings Exposed) Extended Lube Lines (Arr. 1, 8, & ) Stainless Steel Nameplate Bases (Unitary, Isolation and Inertia) 4 TWIN CITY FAN - CATALOG 120

OPTIONS/ACCESSORIES 2 Customer Ductwork 1 Customer Ductwork 3 4 1 2 3 Flanged Inlet Punched to ANSI 1/0 hole pattern for bolted connection is standard. Other patterns available upon request. Flanged Outlet Punched to ANSI 1/0 hole pattern for bolted connection is standard. Other patterns available upon request. Drain Standard 3 4" NPT half coupling located at the lowest point of the housing. Available with or without plug. Outlet Blast Gate with Handle A wafer-type butterfly valve for mounting to outlet flange allows controlling flow to full shutoff. Available for automatic control. Maximum temperature 0 F. Tube-Adapter with Rubber Sleeve & clamps (on inlet & outlet) Offers flexible connection between the fan and connecting ductwork. Flexible rubber sleeve is good to 0 F operation. 4 Vibration Rails w/ RIS Isolators Designed to limit forces transmitted to the support structure of an operating fan. Constructed of structural angle, the rails extend the distance between mounting points distributing a more even load to the isolators. Rubberin-shear type isolators and flexible connectors at inlet and outlet are often required. Twin City Fan WWW.TCF.COM

ENGINEERING DATA Maximum RPM, Wheel Weights and WR 2 (moment of inertia in lb-ft 2 ) HOUSING 3 4 FAN SIZE WHEEL MAX. RPM WEIGHT (LB) WR 2 (LB-FT 2 ) 1 0 38.2.4 0 41.2 11.4 21 0 44.3 13. 22 0 47. 1.1 1 0 41..8 0 4.1 12.8 21 0 48..2 22 0 1. 17.8 21 0 44.3 13. 22 0 47. 1.1 23 0 2.1 1.3 2 0. 32. 21 0 48..2 22 0 1. 17.8 23 0 7.8 21. 2 0 78.4 3. Inlet Suction Pressure Correction If the inlet pressure is suction or negative, the static pressure required must be corrected by the inlet density ratio. Example: Operating conditions: 70 F at sea level. System resistance at the inlet of the fan is ". The correction factor from the table at right is 0.02, or it can be calculated as follows: (7. ") 7. = 0.02 Equivalent static pressure to be used for selection from the standard performance curves: " 0.02 = 44.3" Actual air density at the inlet of the fan: 0.07 lb/ft 3 x 0.02 = 0.07 lb/ft 3 Inlet Suction Pressure Correction Factors Shaft & Bearings HOUSING FAN SIZE ARR. 1 & WHEEL DIAMETER HDB: Heavy Duty Ball Bearing Housing Thickness SHAFT DIAMETER (IN.) BEARING TYPE 3 All 1-11/1 HDB 4 All 1-11/1 HDB All 1-/1 HDB All 1-/1 HDB Bare Fan Weights (Lbs.) HOUSING FAN SIZE WHEEL DIAMETER WEIGHT (LBS.) ARR. 1 & ARR. 4 3 1 23 27 3 2 278 3 21 270 281 3 22 273 284 4 1 271 283 4 27 28 4 21 278 20 4 22 281 23 21 37 3 22 380 38 23 384 2 2 2 4 21 30 8 22 33 412 23 3 417 2 4 438 Note: Weights provided above are for the largest inlet/outlet size available on the housing. HOUSING THICKNESS FAN SIZE SIDES SCROLL ALL GA. GA. INLET SUCTION PRESSURE (IN. W.G.) CORRECTION FACTOR 0.88 0.7 0.3 0.1 0.3 0.2 3 0.14 0.02 4 0.80 0 0.877 0.8 Correction Factor = (7. Inlet Suction Pressure) 7. Temperature Derate AIRSTREAM TEMP ( F) DERATE FACTOR 70 1.00 0 1.00 0 1.00 0 1.00 Twin City Fan TWIN CITY FAN - CATALOG 120

PERFORMANCE DATA Model Nomenclature PBW 2 08 MODEL INLET DIAMETER (IN.) 0 = inches, 08 = 8 inches, = inches HOUSING SIZE 3, 4,, NOMINAL WHEEL DIA. (IN.) 1,, 21, 22, 23, 2 Twin City Fan PBW In. Inlet Outlet Area: 0.1 ft 2 310,, 32, 32 300 300 RPM RPM 3 4½ 7 7½ 8 32 4 4½ 7 7½ 32 8 3½ 4 4½ 7 3 3½ 4 7½ 4½ 8 7 310 7½ 8 0 (1) 0 (37) 00 () 800 (74) 00 (03) (112) 10 (71) 0 (814) 1800 (17) 00 CFM (18) (OV) PBW In. Inlet Outlet Area: 0.1 ft 2 410, 410,,, 42, 42, 42 42 300 300 RPM RPM 3 7 7½ 8 42 7 7½ 8 42 4½ 7 7½ 8 4 4½ 7 7½ 410 8 0 (1) 0 (37) 00 () 800 (74) 00 (03) (112) 10 (71) 0 (814) 1800 (17) 00 (18) 20 (11) 20 CFM (12223) (OV) Performance shown is with a ducted outlet and a ducted inlet or inlet with venturi. WWW.TCF.COM 7

PERFORMANCE DATA PBW In. Inlet Outlet Area: 0.34 ft 2 2, 2, 2, 20 300 RPM 2, 2, 2, 20 300 RPM 0 0 20 7 8 7½ 2 7 8 7½ 2 7 7½ 8 2 3 0 (71) 00 (1432) 70 (214) 00 (28) (381) 00 (427) 170 (013) 00 (7) 20 (44) 00 (712) 270 (7878) 00 (84) (311) 300 CFM (027) (OV) PBW 8 In. Inlet Outlet Area: 0.1 ft 2 3108, 8, 328, 328 300 RPM 3108, 8, 328, 328 300 RPM 3 7 7½ 8 328 7 7½ 8 4½ 328 4 4½ 7 7½ 8 8 3½ 4 4½ 7 7½ 8 3108 0 (1) 0 (37) 00 () 800 (74) 00 (03) (112) 10 (71) 0 (814) 1800 (17) 00 CFM (18) (OV) PBW 8 In. Inlet Outlet Area: 0.1 ft 2 4108, 8, 428, 428 300 RPM 4108, 8, 428, 428 300 RPM 3 7 7½ 8 428 7 7½ 8 428 4½ 7 7½ 8 8 4 4½ 7 7½ 8 4108 0 (1) 0 (37) 00 () 800 (74) 00 (03) (112) 10 (71) 0 (814) 1800 (17) 00 (18) 20 (11) 20 (12223) 200 CFM (13242) (OV) Performance shown is with a ducted outlet and a ducted inlet or inlet with venturi. 8 TWIN CITY FAN - CATALOG 120

PERFORMANCE DATA PBW 8 In. Inlet Outlet Area: 0.1 ft 2 28, 28, 28, 208 30 RPM 28, 28, 28, 208 300 RPM 0 0 208 7 7½ 8 28 7 7½ 8 28 4½ 7 7½ 8 28 3 0 (1273) 00 (4) 70 (38) 00 (03) (3) 00 (73) 170 (813) 00 (18) 20 (114) 00 (12732) 270 (10) 00 (27) (12) 300 CFM (178) (OV) PBW 8 In. Inlet Outlet Area: 0.34 ft 2 28, 28, 28, 28, 28, 28, 208 208 300 300 RPM RPM 0 0 208 8 28 7 8 7½ 28 7 8 7½ 28 0 (8) 00 (171) 00 (78) (3438) 00 (427) 1800 (7) 20 (01) 20 (87) 2700 (773) 3 00 (84) 30 (44) 0 (313) 3 4 300 (11173) CFM (132) (OV) PBW In. Inlet Outlet Area: 0.1 ft 2 31, 3, 321, 322 300 RPM 31, 3, 321, 322 300 RPM 3 7 8 7½ 322 7 7½ 8 321 4 4½ 7 7½ 8 3 4 4½ 7 7½ 8 31 0 (1) 0 (37) 00 () 800 (74) 00 (03) (112) 10 (71) 0 (814) 1800 (17) 00 (18) 20 (11) 20 CFM (12223) (OV) Performance shown is with a ducted outlet and a ducted inlet or inlet with venturi. WWW.TCF.COM

PERFORMANCE DATA PBW In. Inlet Outlet Area: 0.1 ft 2 41, 4, 421, 422 300 RPM 41, 4, 421, 422 300 RPM 3 7 422 421 4 41 8 7½ 7 7½ 8 7 7½ 8 7 7½ 8 0 (1273) 00 (4) 70 (38) 00 (03) (3) 00 (73) 170 (813) 00 (18) 20 (114) 00 (12732) 270 (10) 00 CFM (27) (OV) PBW In. Inlet Outlet Area: 0.1 ft 2 21, 22, 23, 2 30 RPM 21, 22, 23, 2 300 RPM 0 0 2 23 22 21 7 8 7½ 7 7½ 8 7 7½ 8 3 0 (1273) 00 (4) 70 (38) 00 (03) (3) 00 (73) 170 (813) 00 (18) 20 (114) 00 (12732) 270 (10) 00 (27) (12) 300 CFM (178) (OV) 21, 22, 23, 2 30 RPM 21, 22, 23, 2 300 RPM PBW In. Inlet Outlet Area: 0.34 ft 2 0 0 3 2 4 8 23 7 8 7½ 22 7 8 7½ 21 3 0 (8) 00 (171) 00 (78) (3438) 00 (427) 1800 (7) 20 (01) 20 (87) Performance shown is with a ducted outlet and a ducted inlet or inlet with venturi. 2700 (773) 00 (84) 30 (44) 0 (313) 300 (11173) CFM (132) (OV) TWIN CITY FAN - CATALOG 120

Arrangement 1 PERFORMANCE DATA TAD DBD BHD BAU UBD TAU Notes: 1. CW rotation shown, CCW rotation similar but opposite. 2. Optional K & B flange per BC08. HOUSING SIZE 3 4 HOUSING SIZE WHEEL DIAMETER (NOMINAL) 1,, 21, & 22 1,, 21, & 22 21, 22, 23, & 2 21, 22, 23, & 2 INLET DIAMETER (NOMINAL) A B BH CB CC D E F FB GC HA HB.0 8.00 4.0 0. 11.7.00.81 13.0 14.00 1.00.0 8.00.0 0. 11.7.00.81 13.0 14.00 1.00.0 8.00 4.7 0. 11.7 2.00 8.7 13.0 14.00 1.00.0 8 8.00.00 0. 11.7 13.0 2.00 8.7 13.0 14.00 1.00.0.00 1.00.3.0.00 1.00.3.0 18.7 2.70 11.7 18.7 2.70 HC HD HE HF HG HH HZ J L M P PF Q R SD DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. CERTIFIED DRAWINGS AVAILABLE UPON REQUEST. MAX MOTOR FRAME EXCL. TAD & BHD.00 3. 17.13 1.1.88.2 14.3 13.88.3 14.3 8.00 2.31 8.00.00 14.7 2.3 1.88 28T 14T.00 4. 17.13 1.1.88.2 14.3 13.88.13 14.3 8.00 2.81 8.00.00 14.7 27.3 1.88 28T 14T.00 22.00 1.2 18.7 18.2 17.7 17.2 18.3.7 18.0.00.31 8.00.00 1.0.7 1.38 32T 184T.00 23. 1.2 18.7 18.2 17.7 17.2 18.3.38 18.0.00.3 8.00.00 1.0 32.00 1.38 32T 184T TAD & BHD BC014B WWW.TCF.COM 11

DIMENSIONAL DATA Arrangement 4 TAD DBD BHD BAU UBD TAU Notes: 1. CW rotation shown, CCW rotation similar but opposite. 2. Optional K & B flange per BC08. HOUSING SIZE 3 4 WHEEL DIAMETER (NOMINAL) 1,, 21, & 22 1,, 21, & 22 21, 22, 23, & 2 21, 22, 23, & 2 INLET DIAMETER (NOMINAL) A B BH CB CC D E F FB GC HA HB.0 8.00 4.0 0. 11.7.00.81 13.0 14.00 1.00.0 8.00.0 0. 11.7.00.81 13.0 14.00 1.00.0 8.00 4.7 0. 11.7 2.00 8.7 13.0 14.00 1.00.0 8 8.00.00 0. 11.7 13.0 2.00 8.7 13.0 14.00 1.00.0.00 1.00.3.0.00 1.00.3.0 18.7 2.70 11.7 18.7 2.70 HOUSING MAX MOTOR HC HD HE HF HG HH HZ J L M PF Q R SIZE FRAME.00 3. 17.13 1.1.88.2 14.3 13.88.3 14.3 8.00 8.00.00 14.7 2.3 28T.00 4. 17.13 1.1.88.2 14.3 13.88.13 14.3 8.00 8.00.00 14.7 27.3 28T.00 22.00 1.2 18.7 18.2 17.7 17.2 18.3.7 18.0.00 8.00.00 1.0.7 32T.00 23. 1.2 18.7 18.2 17.7 17.2 18.3.38 18.0.00 8.00.00 1.0 32.00 32T BC01B DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. CERTIFIED DRAWINGS AVAILABLE UPON REQUEST. 12 TWIN CITY FAN - CATALOG 120

Arrangement DIMENSIONAL DATA TAD DBD BHD BAU UBD TAU Notes: 1. CW rotation shown, CCW rotation similar but opposite. 2. Optional K & B flange per BC08. 3. Standard Arr. motor location is on the left for CW rotation and on the right for CCW rotation except BHD which is right for CW and left for CCW. HOUSING SIZE 3 4 HOUSING SIZE WHEEL DIAMETER (NOMINAL) 1,, 21, & 22 1,, 21, & 22 21, 22, 23, & 2 21, 22, 23, & 2 INLET DIAMETER (NOMINAL) A B BH CB CC D E F FB GC HA HB.0 8.00 4.0 0. 11.7.00.81 13.0 14.00 1.00.0 8.00.0 0. 11.7.00.81 13.0 14.00 1.00.0 8.00 4.7 0. 11.7 2.00 8.7 13.0 14.00 1.00.0 8 8.00.00 0. 11.7 13.0 2.00 8.7 13.0 14.00 1.00.0.00 1.00.3.0.00 1.00.3.0 18.7 2.70 11.7 18.7 2.70 HC HD HE HF HG HH HZ J L M P PF Q R SD MAX MOTOR FRAME.00 3. 17.13 1.1.88.2 14.3 13.88.3 14.3 8.00 2.31 8.00.00 14.7 2.3 1. 2T.00 4. 17.13 1.1.88.2 14.3 13.88.13 14.3 8.00 2.81 8.00.00 14.7 27.3 1. 2T.00 22.00 1.2 18.7 18.2 17.7 17.2 18.3.7 18.0.00.31 8.00.00 1.0.7 1.4 T.00 23. 1.2 18.7 18.2 17.7 17.2 18.3.38 18.0.00.3 8.00.00 1.0 32.00 1.4 T BC00A DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. CERTIFIED DRAWINGS AVAILABLE UPON REQUEST. WWW.TCF.COM 13

ALTERNATIVE PRESSURE BLOWERS Models HRO HRS HRO Wheel Sizes 1.7" to 1." wheel diameters Performance Airflow to,000 CFM Static pressures up to 1" w.g. See Catalog for more information HRS Wheel Model TBR Sizes.7" to 3.1" wheel diameters Performance Airflow to,0 CFM Static pressures to 4" w.g. See Catalog for more information Model TBA Sizes 11.1" to 32.0" wheel diameters Performance Airflow to 28,700 CFM Static pressures to 70" w.g. See Catalog for more information 14 TWIN CITY FAN - CATALOG 120

ALTERNATIVE PRESSURE BLOWERS Models MBO MBR MBW Sizes 1.3" to 8.4" wheel diameters MBO Performance Airflow to 18,000 CFM Static pressures over 170" w.g. MBR Performance Airflow to 18,000 CFM Static pressures over 180" w.g. MBW Performance Airflow to,000 CFM Static pressures over " w.g. See Catalog 10 for more information MBO Wheel MBR Wheel MBW Wheel Model BCN Sizes 27" to 73" wheel diameters Performance Airflow to 7,000 CFM Static pressures to 0" w.g. See Catalog 1 for more information WWW.TCF.COM

TYPICAL SPECIFICATIONS Model PBW Fans shall be Type PBW Pressure Blowers as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Fans shall be tested in accordance with ANSI/AMCA Standard 2 (air performance) and 0 (sound performance) in an AMCA accredited laboratory. HOUSING Fan housings shall be constructed of continuously welded heavy gauge steel. All sizes shall be rotatable and reversible. A choice of inlet connections shall include an inlet venturi with screen, an inlet pipe assembly and a punched flange to ANSI 1/0 bolt pattern. The outlet connection shall be flanged and punched to ANSI 1/0 bolt pattern. Inlet and outlet flanges with alternate bolt patterns shall be available. WHEEL Wheels shall be constructed of continuously welded heavy gauge steel or from a variety of special materials. Wheels shall be statically and dynamically balanced. The complete fan assembly shall be test balanced at the operating speed prior to shipment. SHAFT (ARR. 1, 8 & ONLY) Shafts shall be AISI 4 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed. BEARINGS (ARR 1, 8 & ONLY) Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, selfaligning, pillow block type and selected for a minimum average bearing life (AFBMA L-0) in excess of 0,000 hours at the maximum fan RPM. FINISH AND COATING The entire fan assembly, excluding the shaft, shall be thoroughly degreased and deburred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum components shall be unpainted. ACCESSORIES When specified, accessories such as inlet filters, inlet filters with hoods, inlet and outlet silencers, flexible connectors for flanged outlet and plain pipe outlets, outlet blast gates, built-in outlet dampers, shaft closure plates, shaft seals, drains, inspection ports, shaft and bearing guards, belt guards, couplings, coupling guards, unitary bases, isolation bases, inertia bases, and vibration rails shall be provided by Twin City Fan & Blower to maintain one source responsibility. FACTORY RUN TEST All fans prior to shipment shall be completely assembled and test run as a unit at operating speed or maximum RPM allowed for the particular construction type. Each wheel shall be statically and dynamically balanced to in accordance with ANSI/AMCA 4- Balance Quality and Vibration Levels for Fans to Fan Application Category BV-3, Balance Quality Grade G.3. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANTEE Manufacturer shall guarantee the workmanship and materials for its Pressure Blowers for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first. 1 TWIN CITY FAN - CATALOG 120

WWW.TCF.COM 17

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CENTRIFUGAL FANS UTILITY SETS PLENUM & PLUG FANS INLINE CENTRIFUGAL FANS MIXED FLOW FANS TUBEAXIAL & VANEAXIAL FANS PROPELLER WALL FANS PROPELLER ROOF VENTILATORS CENTRIFUGAL ROOF & WALL EXHAUSTERS CEILING VENTILATORS GRAVITY VENTILATORS DUCT BLOWERS RADIAL BLADED FANS RADIAL TIP FANS HIGH EFFICIENCY INDUSTRIAL FANS PRESSURE BLOWERS LABORATORY EXHAUST FANS FILTERED SUPPLY FANS MANCOOLERS FIBERGLASS FANS CUSTOM FANS Twin City Fan TWIN CITY FAN & BLOWER WWW.TCF.COM TRENTON LANE N MINNEAPOLIS, MN 442 PHONE: 73-1-700 FAX: 73-1-701 18 Twin City Fan Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog illustrations cover the general appearance of Twin City Fan & Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.