INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Similar documents
INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

CCTV Rack Mount Power Supplies

Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 336

Language specific user manuals are available on

Xenon Fiberoptic Lightsource

Switching DC Power Supply

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Isolation Transformer for Medical Applications

Security Plus Online Uninterruptible Power Supply

Language specific user manuals are available on

Powerware Vdc Extended Battery Cabinet User s Guide.

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

DSP led gaming monitor USER MANUAL

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

Battery Power Inverters

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

DC CCTV Power Supplies Installation Guide

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Power Blade Charger Users Guide

AM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368

Multi-Mover Charger for model L25

c-go 24V/6A 24V/8A 24V/12A

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Cruising Charger Series OWNER S MANUAL

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

SLA Battery Capacity Analyzer

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Owner s Manual. OutCast 1.2. The Ultimate Outdoor Speaker System

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

Rental Industry Safety Tester Safe Check 5s

Fiber Optic Illuminator. Model 21AC Model 21DC

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

AC CONVERTER / BATTERY CHARGER

FieldView External Charger. User Guide

- Wiring Brochure tn4 Gateway 483

RVS-AX Instruction Manual

SCXI Power Supply/Float Charger Installation Guide

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Installation Instructions

SMP3CTX Series Power Supply/Charger

BATTERY SAVER LOW RIPPLE HO

innovations in battery charging

EASY CHARGE Weather-resistant fixed mount Battery Charger

Model 1693, 1694 Switching DC Power Supply

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

owner s manual IsoCenter-NS Series Rackmount Shielded Isolation Transformer and Power Distribution Center

- Wiring Brochure Mixing Expansion Module 440

Products :: Circuit Protection :: Thermal Circuit Breakers

User s Manual. Automatic Switch-Mode Battery Charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

POWER INVERTER 700 WATT / 1800 WATT PEAK

Installation Instructions

10 AMP ON BOARD BATTERY CHARGER

Uninterruptible power supply Supply MEg101.4

UNIVERSAL BATTERY CHARGER II

QSSE, QSSEX INDUSTRIAL Battery Chargers

Operating Instructions

WF-5110R True Sine Wave Inverter

ISO FM Made in the U.S.A

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

PRODUCTS: POWER SUPPLY

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Ensuring the Safety Of Medical Electronics

Smart Battery Charger

Model 1672, 1673 Triple Output Power Supply

Power Inverter 400 MW Owner s Manual

POWERWARE User s Guide VA.

DC to AC Power Inverters

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

DC to AC Power Inverters

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power cord and plug. If any damage is observed, do not use this product. Contact Toroid Corporation or its authorized agent for instructions to return the product for repair or replacement. The ISOBOX Series Isolation transformers are intended for applications where medical devices require improved electrical isolation and/or reduced leakage current to comply with existing safety standards. With the ISOBOX connected between the device and the wall outlet where the device is installed, the leakage current and the electrical isolation of the installed device will have the data of the ISOBOX. (See data on following pages). DANGER: WARNING: NOTE: WARNING: WARNING: Risk for explosion exists if used in the presence of flammable anesthetics, or other flammable gases or liquids. Grounding continuity should be checked periodically To reduce the risk of electrical shock, do not open enclosure. There are no serviceable parts inside. Refer service to Toroid Corporation or its authorized agent only. Do not expose this equipment to rain or moisture. To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth USA and Canada, Grounding reliability can only be achieved when this equipment is connected to a matching receptacle marked Hospital Only, or, Hospital Grade. This product requires convection cooling. Adequate ventilation is therefore required. When installing this product, a minimum clearance of 2 should be provided to all sides, except mounting surface. No modification of this equipment is allowed. To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth Caution should be taken to use in life supporting equipment as this unit may shut down for safety reasons due to overload or short circuit, and render medical equipment without power. An Auto reset thermal switch may open at an overload condition and will, without warning, turn power back on automatically when device cools down. EXPLANATION OF GRAPHICS SYMBOLS The exclamation point with an equilateral triangle is intended to alert the users to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. The open book with an i is intended to alert users of the importance to read the operating instructions prior to installation and use. Page 1 of 6

TRANSPORT AND STORING CONDITIONS: Temperature range; -30 Degr.C (-22F) to 70 Degr.C (158F). Humidity; up to 95% RH (non-condensing). Altitude Range; up to 15,300m (50,000ft) OPERATING CONDITIONS: Temperature range; -10Degr.C (14F) to 40 Degr.C (104F). Humidity: up to 95% RH (non-condensing). Altitude Range; Up to 4,600m (15,000ft) CLEANING INSTRUCTIONS: This is an electrical device. Do not clean this device with power on or the power cord attached to an outlet. Only use a dry rag or cloth. PERIODIC MAINTENANCE AND INSPECTION. No regular maintenance is required for this device though a regular inspection is recommended. Grounding continuity should be checked periodically by a qualified technician. Inspection should also consist of checking that plugs are engaged and not damaged. Any cords should not be damaged or knotted. Damage to the enclosure or any parts of the device should be evaluated by the manufacturer or qualified technician. Frequency of inspection and cleaning is dependent on location and type of use and should be determined by an engineer, the equipment maintenance department or personnel. Inspect the devices at a minimum of once per year. MOUNTING INSTRUCTIONS: The ISOBOX isolation transformer may be placed horizontally on any flat stable surface such as a floor or table top. For high traffic areas, carts and unstable surfaces, use of the mounting brackets for all mounting locations is recommended to ensure the stability of the ISOBOX. The ISOBOX may also be vertically mounted to a wall by removing the four rubber feet on the bottom of the enclosure and replacing the rubber feet with the two mounting brackets supplied. The same Phillips head screws should be used for this. For wall mounting, please use appropriate wall anchors unless fastened into wall stud(s) or other forms of enforcement available to support the weight of the enclosure. Appropriate air clearance for ventilation of ISOBOX is required (see CAUTION paragraph on previous page). Page 2 of 6

OPERATING INSTRUCTIONS: The W series IsoBox offers flexibility with selectable input and output voltage. Therefore you must ensure correct input voltage and output voltage settings or you may put people in danger or create hazardous conditions and, you may severely damage equipment and parts connected to it. Recommended initial installation procedure: 1. Adjust and verify IsoBox input voltage setting to intended and available supply. 2. Adjust and verify IsoBox output voltage setting to match attached equipment. 3. Verify correct fuse rating in power entry module. See page 4 for correct fuses for your IsoBox and settings. 4. Mount IsoBox per above recommendations, note required spacing and air clearance. 5. Verify power switch on the ISOBOX is in the OFF (0) position. 6. In Canada and USA, when connecting the ISOBOX to the wall outlet, plug only into a Hospital Grade Wall Outlet to ensure reliable grounding. 7. Connect ISOBOX to Wall outlet. 8. Verify equipment to be connected to the ISOBOX is turned OFF (0). 9. Connect the devices to the receptacles of the ISOBOX. 10. Turn ON (1) the power switch of the ISOBOX. 11. The devices connected to the ISOBOX are now ready to be turned ON (1) and operated. Note detachable power cord requirements below. The total power consumption equals the sum of all devices connected to the ISOBOX. The total power consumption must not exceed the maximum power rating of the ISOBOX, as shown on the product rating label or table below. If too much power is used, the IsoBox may overheat. To reduce inrush currents, the W series employs a NTC thermistor. After turning off the IsoBox unit it is recommended to let the ISOBOX cool down for approximately 1 minute. There may otherwise be a risk of blowing a fuse in the power entry module or possibly tripping the wall outlet circuit breaker. ELECTROMAGNETIC COMPATIBILITY This equipment has NOT been tested to comply with the limits for medical devices to the IEC 601-1-2:1994. The limits in this standard are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy and, may cause harmful interference to other devices in the vicinity. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving device. - Increase the separation between the equipment. - Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected. - Consult the manufacturer or field service technician for help. Page 3 of 6

ISOBOX SPECIFICATIONS. All ISOBOX models listed in this document are intended for 115 (120) or 230 (240) VAC and 50/60 Hz input frequency. DO NOT USE OTHER VOLTAGES OR FREQUENCIES. See Datasheet for mechanical data. Model No. Rated Input Current at 115(120) / 230(240)V 50/60Hz Output voltage (VAC) Maximum Output current (Amps) Output Power * (VA) Leakage current 132V Nom/ 1 fault ** Leakage current 264V Nom/ 1 fault ** ISB-030W 2.7 / 1.35A 120/240 2.5/1.25 300 30/50*** 50/100*** ISB-060W 5.28 / 2.64A 120/240 5.0/2.5 600 30/55*** 55/100*** ISB-100W 8.7 / 4.35A 120/240 8.33/4.17 1000 30/55*** 60/110*** * Maximum total output power of the ISOBOX, whether one or more outlets are used. Rating at 120/240V. ** Nominal leakage current is measured at normal use and in no fault condition. 1 (single) fault leakage current is measured as Non-Patient connected, with reversed polarity and under single fault condition. *** Measured sample values. This is a Class 1 transformer. MECHANICAL DATA: See Individual Data Sheets. POWER CORD REQUIREMENTS: Input: All power cords must be appropriately approved by testing agency for the country where the ISOBOX is operated in, such as UL/CSA/VDE/SEMKO/<HAR> etc. For the US and Canadian Market, a HOSPITAL GRADE Plug is required. One end (plug) must be appropriate for the wall receptacle, the other to fit into the power inlet of the ISOBOX, this end must be of appliance type, IEC-320 female plug. All power cords must have grounding. Model Minimum wire Length Diameter Recommended ISB-030W AWG 18 (0.75mm 2 ) Less than 12 ft (3.6m) ISB-060W AWG 18 (0.75mm 2 ) Less than 12 ft (3.6m) ISB-100W AWG 16 (1.00mm 2 ) Less than 12 ft (3.6m) Page 4 of 6

FUSE REQUIREMENTS: These ISOBOX transformers have been tested, approved and deemed safe under certain conditions. The fuse in the power entry module is protecting the ISOBOX from overloads and short circuits. If the incorrect fuse is used, there may be danger to operator(s) or patient(s), or damage to equipment. Fuses must be UL and CSA approved and marked for North American use and VDE/EN approved and marked for European use. Use only SLOW BLOW type (T-type) fuse rated 250V. IEC 60601.1 3 rd edition requires Hi Breaking Capacity fuses, also known as Interrupting Current, (1500A) if the prospective short circuit current is 35A or 10x current rating of the fuse, whichever is higher. UL 246 (for UL installations) requires breaking capacity 1.1-3.5A =100A, 3.6-10A =200A, 10.1-15 =750A This table describes the recommended fuses (approved in Critical Component List), manufacturer and series description for each input setting; ISB-030W 115/120V 230/240V 3.15AT Part. No. 1.6AT Part No. Littelfuse 02153.15 Littelfuse 021501.6 Schurter (SPT) 0001.2509 Schurter (SPT) 0001.2506 Bussman S505-3.15-R Bussman S505-1.6-R Littelfuse 02393.15* Littelfuse 021301.6* Littelfuse 021801.6* Littelfuse 023901.6* Schurter (FST) 0034.3119* ISB-060W 115/120V 230/240V 6.3AT 3.15AT Littelfuse 021506.3 Littelfuse 02153.15 Schurter (SPT) 0001.2512 Schurter (SPT) 0001.2509 Bussman S505-6.3-R Bussman S505-3.15-R Littelfuse 023906.3** ISB-100W 115/120V 230/240V 10AT 5.0AT Littelfuse 0215010. Littelfuse 215005. Schurter (SPT) 0001.2514 Schurter (SPT) 0001.2511 Bussman S505-10-R Bussman S505-5-R *These are approved fuses for installation outside of North America as the projectable short circuit current is less than 35A **This is a UL Listed product and is approved for use in USA only DO NOT USE FUSES WITH HIGHER AMP RATING. Page 5 of 6

TROUBLE SHOOTING: DO NOT ATTEMPT TO REPAIR. WARRANTY WILL BE VOID IF UN-AUTHORIZED REPAIR WORK HAS BEEN CARRIED OUT. No output power: 1. Verify that the ISOBOX is connected and that the power switch is ON (1). 2. With all power in, and power out disconnected from the ISOBOX verify that the fuses in power entry module are operating. 3. Use another wall outlet. 4. Check wall outlet circuit breaker. 5. If you have any other problems with the ISOBOX, please call Toroid Corporation for return instructions on our toll-free number; 1-800-274-5793. If you notice any Mechanical Damage: Call Toroid Corporation for return instructions. LIMITED WARRANTY: The ISOBOX series enclosed isolation transformers are backed by Toroid Corporation s 36 month warranty. For complete information, please refer to the warranty card enclosed with this package. SAFETY AGENCY LISTINGS: The W series IsoBoxes has been tested and approved by UL to the following standards: Listee Cert./Rep.No s/ul Category Standards Markings CB Cert. No: US-ITS-225 IEC 60601-1 (2 nd Ed) - CB Cert. No: E482313-D1000-1/A0/C0-ULCB IEC 60601-1 (3rd Ed, Am1) - CE mark CE012 (self declared) Low Voltage Directive CE UL List/Cert E183813 KFCG UL60601-1 (1 st ed) UL E183813 KFCG7 CSA C22.2 No. 601.1 cul UL Recogn. E482313 QQMH2 ANSI/AAMI ES60601-1:2005/(R)2012 RU E482313 QQMH8 CSA CAN/CSA-C22.2 NO. 60601-1 (2008) cru RECYCLING: Much of this product can be recycled. Please do not dispose in general waste. Turn into a recycling center that is equipped to handle electrical equipment. This part is ROHS II compliant. Page 6 of 6