PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

Similar documents
Model &

Flojet Rewrites the Book on Small Pump Control

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

50830 Series Low Pressure Centrifugal Pump

05 Water Pressure Systems INTRODUCTION

Troubleshooting WARNING

08 general Purpose Pumps

Marine Pumps & Accessories

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

PowerFLO 5800/5900 Series

General Purpose Pumps - Introduction

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

07 Oil Change & Diesel Transfer Pumps

Fully Automatic Bilge Pump INSTRUCTION MANUAL

M-3025CB-AV Fuel Pump

07 Oil Change & Diesel Transfer Pumps

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Assembly / Operation Instructions / Parts

Rev: Flow Max 115V AC Fluid Pump

WORKHORSE. Assembly / Operation Instructions / Parts

WORKHORSE. Assembly / Operation Instructions / Parts 15 GALLON TRAILER SPRAYER

MODEL MC1500 Installation and Operation Manual Important:

Electric Diesel Pump EDP/12, EDP/24

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

Models Series Series

WORKHORSE. Assembly / Operation Instructions / Parts DELUXE ATV BOOMLESS SPRAYER

WORKHORSE. Assembly / Operation Instructions / Parts 25 GALLON TRAILER SPRAYER

Installation & Operating Manual

Model: PumpAgents.com - buy pumps and parts online JABSCO Y-VALVE. Model: FEATURES INSTALLATION APPLICATION

SUNC3000 / Item #40885

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

Toilet Systems - Introduction

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

Ph: (07) Fax: (07) Pump Manual

HALLMARK INDUSTRIES INC

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

WORKHORSE. Assembly / Operation Instructions / Parts

SeaEra QC Toilet. Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

Electric Fuel Pump FPM

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SeaEra QC Toilet Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

SUPER PUMP OUT SYSTEM

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Installation, Operation & Maintenance Manual

WORKHORSE PSE. Assembly / Operation Instructions / Parts GENERAL INFORMATION WARRANTY / PARTS / SERVICE ASSEMBLY

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

WORKHORSE. Assembly / Operation Instructions / Parts

Aquajet AMERICA. RV Water System Pumps OWNER S MANUAL. The Standard For Professional Grade Diaphragm Pumps. MADE IN

ProFlo FatBoy

Whale - Electric Bilge Pump Range From the Experts in Bilge Pumps experience in electronics

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

PumpAgents.com - Click here for Pricing/Ordering INSTALLATION * Crusader is a registered trademark of Thermo Electron Corporation.

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Operating and Installation Instructions

Aquajet. User s Manual and Installation Guide. RV Water System Pumps

Professional Grade Agricultural Pumps.

2 Wire Plus Ground 3 Wire Plus Ground IL0655

OWNER S MANUAL CONVERTIBLE JET PUMP

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc.

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Oil Pump Models L 5016, L 5116 & L 5132

WORKHORSE PSE. Assembly / Operation Instructions / Parts

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

12 Volt DC Diaphragm Pumps Series 400

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

WORKHORSE PSE. Assembly / Operation Instructions / Parts

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

Model 1210C Battery Powered Pump Shown

Electric Fuel Pump FPM

RV PRODUCT DATA SHEET

Owners Manual: - Pumps

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Transcription:

PumpAgents.com - Click here for Pricing/Ordering Models 41700 / 51700 - Series Washdown Pump WASHDOWN PUMP 0 PSI (5.5 BAR) 7.5 GPM (29 LPM) 6.0 GPM (23 LPM) FEATURES High Pressure / High capacity Pumpgard TM Intake Strainer and Pressure Nozzle Included (Suitable for Use in Salt Water) Corrosion Resistant Soft Rubber Mounts Snap-fit Port Fittings and 24 VDC Models Self-Priming up to 6 feet (1. m) Motor Rating: IP 54 ISO 46 MARINE (Ignition Protection) SPECIFICATIONS Pump Body- Glass Filled Nylon Pump Design- 5 Chamber Diaphragm Suction Lift- Self Priming to 6 ft. (1.m) Ports- 3/4 (19 mm) Hose Barb, 1/2 - QEST straight, 3/4 (19 mm) Hose Barb 90 elbow, 1/2 - QEST 90 elbow Motor- Permanent Magnet Model Nominal DC Volts Amp Draw (A) @ psi (0.7 bar) Fuse Size (A) WASHDOWN PUMP Dimensions English (SI) Pump Height Length Width Weight Series inches (mm) inches (mm) inches (mm) Lb (Kg) 41700 7.3 (15) 11. (300) 6.1 (155).0 (3.6) 51700 7.3 (15).2 (259) 6.1 (155) 9.5 (4.3) Open Flow GPM (LPM) Switch Max PSI (bar) Inlet Strainer 41700-0092 9.0 25 6.0 (23) 0 (5.5) Yes Yes 41700-0094 24 4.5 15 6.0 (23) 0 (5.5) Yes Yes 51700-0092 13.5 40 7.5 (29) 0 (5.5) Yes Yes 51700-0094 24 6. 20 7.5 (29) 0 (5.5) Yes Yes Nozzle Models 41700 / 51700 - Series Dimensional Drawing 7.3" (16 mm) 4.1" (4 mm) 4.0" (2 mm) 2.7" (69 mm) 11." (300 mm) 3.0" (76 mm) 5.4" (137 mm) 4.0" 2.7" 1.4" (2 mm) (69 mm) (36 mm).2" (259 mm) 41700-Series 6.1" (155 mm) 41700/51700 SERIES 51700-Series Performance data based upon tests at 13.6 V (V) and 27.2 V (24V)

Black ( ) 20 Amp Fuse holder (+) ( ) Red (+) Figure1 Figure 2 Switch /24V DC Battery INSTALLATION (Fig.1) Remove shipping plugs from the pump ports. There may be a slight amount of water that drains out of the pump as all pumps are tested at the factory before shipment. A direction arrow can be found on the pump head to indicate direction of flow. Insert Pumpgard TM strainer into pump intake port. Snap the gate closed to retain the strainer firmly in the pump body. The strainer should be checked on a regular interval to remove debris. Blockage will affect the pump and motor life and flow performance. Connect the discharge fitting of the pump, utilizing the selection to a faucet, bib or valve. Use 3/4 (19 mm) or 1 (25 mm) braided reinforced hose and a worm screw hose clamp for hose connection to all fittings. MOUNTING The Washdown pumps are self-priming and may be located above or below the water supply in a dry location. To vertically mount these units, it is best to do so with the motor on top. This will prevent water dripping on the motor in the event of a leak. Place pump on a solid surface and secure with the four mounting screws; be careful not to compress the rubber grommets, which act as vibration dampers. IF YOU ARE NOT FAMILIAR WITH APPLICABLE ELECTRICAL STANDARDS, HAVE THE UNIT INSTALLED BY A QUALIFIED ELECTRICIAN. IT IS RECOMMENDED THAT MARINE GRADE REINFORCED HOSE BE USED FOR ALL PLUMBING WITH THESE MODELS OF WASHDOWN PUMPS WIRING Suggested wiring information is given as a reference. For proper information, please reference USCG regulations for marine applications and wiring gauges, connectors and fuse protection. STEP 1 Determine the distance from the power source to the pump and then double the measurement. Wire gauge installation is determined on the entire run length, to the pump and back. For wire gauge recommendations, please see the charts on the last page. STEP 2 Connect to power supply lead (red)(+) to the positive (+) terminal on the battery or through a properly installed fuse / circuit breaker panel. Then run the length of wire to the pump, connecting the red wire through a switch appropriately rated to the pump s current requirements. STEP 3 Route the wire so as not to create hazards in operation of the engine, movement of steering components or human traffic. PLUMBING STEP 4 Connect the red lead to the red/orange lead on the pump housing located pressure switch. STEP 5 Connect the black lead from the pump to the ground or negative power side (-) of the vessel. STEP 6 Turn the system off when not in use for extended periods of time or when the water supply tank is empty. STEP 7 After installation, check voltage at the pump motor. Voltage should be checked when pump is operating. Full voltage must be available at the pump motor at all times for proper pump operation and pump motor life. 41700 / 51700 - Series. Washdown/Livewell (Fig. 3) Install the Pumpgard TM strainer (provided) to the hose from the water source (thru-hull seacock or water tank). Connect the strainer to the pump inlet port. Connect the pump discharge to a 3-way valve or T (if livewell has a shutoff valve). Connect to livewell and to hose bib. From hose bib use supplied pressure nozzle. 41700 / 51700 - Series. w/rule Dual Port (Fig. 4) Install Rule dual port pump to seacock. Connect hose from dual port pump to livewell/baitwell tank (see Fig. 4). Connect washdown hose from dual port pump to strainer, connect to pump inlet port. Connect hose from pump outlet to pressure nozzle. Figure 3 FIgure 4 Rule

OPERATION CAUTION Motor case could get hot during extended 1. Open seacock (washdown or livewell applications). operation. Prolonged contact with skin may cause a burn. 2. Open hose bib and/or pressure nozzle. 3. Turn on pump. 4. Close pressure nozzle/hose bib when water runs free of air. Pump is now ready for automatic demand operation. 5. For prolonged operation, pump must operate at full open flow or motor will overheat. Exploded View 9 Service Parts Part Number Key Description 41700-0092 41700-0094 51700-0092 51700-0094 1 Pressure Switch 1753-5019 1753-5019 1753-5019 1753-5019 2 Upper Housing 1753-5009 1753-5009 1753-5009 1753-5009 3 Check Valve Assembly 1753-5006 1753-5006 1753-5006 1753-5006 4 Lower Housing Assembly 1753-503 1753-503 1753-5000 1753-5000 5 Motor With Baseplate 1753-5022 1753-5026 1753-5024 1753-502 6 Clips 1753-5021 1753-5021 1753-5021 1753-5021 7 Clamps 1753-501 1753-501 1753-501 1753-501 Pressure Nozzle 30702-00 30702-00 30702-00 30702-00 9 Nozzle Adapter 50647-00 50647-00 50647-00 50647-00 Pumpgard TM Strainer 46400-0711 46400-0711 46400-0711 46400-0711 TROUBLESHOOTING Failure to Prime - Motor operates, but no water flows Debris in pump: Defective check valve assembly: Air leak in intake line: Restricted intake or discharge line: Punctured diaphragm (pump leaks): Crack in pump housing (pump leaks): Empty water supply tank: Motor fails to run Pump circuit has no power: Loose or corroded wiring connection: Blown fuse or open breaker: Open thermal protector (motor shell hot): Defective motor: Pump fails to turn off after all fixtures are closed Empty water supply tank: Air trapped in pump: Debris in pump: Defective check valve assembly: No battery in circuit: Punctured diaphragm (pump leaks): Discharge line leak: Low flow or pressure Debris in inlet strainer: Water filter needs changing: Under-sized plumbing or long runs: Defective motor: Loose or corroded electrical connections: Inadequate wire gauge WARNING: BEFORE SERVICING PUMP, TURN OFF POWER TO PUMP AND DRAIN SYSTEM!! Remedy Remove upper-housing and clean Replace check valve assembly Tighten all clamps, inspect plumbing Remove lines and inspect Replace lower housing assembly Replace housing or pump head Refill or turn off power to pump Check wiring, fuse or breaker Inspect wire connections Replace or reset Wait 20 to 30 minutes for auto reset Replace motor Refill Open faucet closest to pump Remove upper-housing and inspect Replace check valve assembly Install battery Replace lower housing assembly Inspect plumbing for leaks Remove cover and clean screen Replace filter cartridge Increase plumbing I.D. Replace motor Inspect wire connections Inspect wire gauge

ACCESSORIES Quick - Connect Port System 50640-00 50642-00 50644-00 1" (25 mm) HOSE BARB 3/4" (19 mm) 1/2" - QEST 50645-00 1/2" - MALE QEST 0 90 ELBOW Wiring Guide For 5 - Chamber Pump 50643-00 3/4" (19 mm) 90 ELBOW 50641-00 1" (25 mm) 90 ELBOW These charts reflect the 3% voltage drop classifications appearing in ABYC's E-11 AC & DC ELECTRICAL SYSTEMS ON BOATS. Wire resistances were taken from NFPA NEC 2002 Handbook, Table. The percentage voltage drops will approximate percentage reductions in open flow from ideal. 41700-0092 Operating Current: 17 A Fuse Size: 25 A AWG 5' (1.5m) ' (3m) 20' (6m) 30' (9m) 41700-0094 Operating Current:.5 A Fuse Size: 15 A AWG 5' (1.5m) ' (3m) 20' (6m) 30' (9m) 51700-0092 Operating Current: 29 A Fuse Size: 40 A Wire sizing for 3% voltage, 1-way wiring run AWG 5' (1.5m) 7.5' (2.3m) ' (3m) 20' (6m) 6 4 51700-0094 Operating Current: 15 A Fuse SIze: 20 A AWG 7.5' (2.3m) ' (3m) 20' (6m) 30' (9m) www.jabsco.com THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE THREE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Jabsco Pumps Home >> Jabsco Pumps stock list >>