Series description: Wilo-Stratos

Similar documents
Series description: Wilo-TOP-S

Heating, air-conditioning, cooling

Data sheet: Wilo-Stratos-D 50/1-12

Data sheet: Wilo-Stratos-D 32/1-8

Series description: Wilo-Stratos ECO-STG

Heating, air-conditioning, cooling

Data sheet: Wilo-Stratos-Z 25/1-8

Data sheet: Wilo-CronoLine-IL-E 100/220-5,5/4-R1

Data sheet: Wilo-CronoLine-IL-E 40/170-5,5/2

Data sheet: Wilo-CronoLine-IL-E 65/170-11/2-R1

Data sheet: Wilo-CronoLine-IL-E 100/150-15/2-R1

Data sheet: Wilo-VeroLine-IP-E 40/130-2,2/2-R1

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

Data sheet: Wilo-Stratos PICO 25/

Series description: Wilo-TOP-STGD

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

Data sheet: Wilo-Stratos PICO 25/1-6

Data sheet: Wilo-Yonos PICO 25/

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Data sheet: Wilo-Yonos MAXO 40/0,5-16

3 Specification Magneta Smedegaard

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

Pump Stations for Heating Circuits

4 Specification Magneta Smedegaard twin pumps

Data sheet: Wilo-Economy MHI 202 (3~400 V, EPDM)

Data sheet: Wilo-CronoLine-IL 125/210-5,5/4

Data sheet: Wilo-VeroLine-IPL 100/ /4

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Data sheet: Wilo-CronoLine-IL 65/160-5,5/2

Data sheet: Wilo-VeroLine-IPL 65/ /2

Series description: Wilo-MultiCargo MC

Series description: Wilo-DrainLift KH 32

Series description: Wilo-Drain STS 40

Data sheet: Wilo-VeroTwin-DPL 65/ /2

Data sheet: Wilo-VeroLine-IPL 65/ /2

Series description: Wilo-Drain MTC

Data sheet: Wilo-VeroTwin-DPL 40/ /4

Data sheet: Wilo-CronoLine-IL 65/130-4/2

Data sheet: Wilo-CronoLine-IL 50/120-2,2/2

Data sheet: Wilo-CronoLine-IL 80/145-1,1/4

Data sheet: Wilo-CronoLine-IL 50/200-1,5/4

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

Data sheet: Wilo-CronoLine-IL 100/250-5,5/4

Data sheet: Wilo-CronoLine-IL 40/220-1,5/4

Data sheet: Wilo-VeroTwin-DPL 50/ /4

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump

Glanded Pumps. Catalogue Heating, Air-Conditioning, Cooling. In-Line Pumps and Accessories. Catalogue A2-50 Hz

Series description: Wilo-Drain TM/TMW/TMR 32

Series description: Wilo-Drain TM/TMW/TMR 32

Data sheet: Wilo-CronoNorm-NL 150/315-37/4

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

EVOPLUS / EVOPLUS SAN

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

General catalogue incl. replacement lists

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

Sewage transport Submersible pumps

Wilo Stratos Z Variable Speed, Wet Rotor Inline Pumps. Engineering Specification

Pressure boosting Single pumps

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Data sheet: Wilo-VeroLine-IPH-W 65/ /4

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Note! Product picture may differ from actual product

Series description: Wilo-Sub TWI 6-..-B

Series description: Wilo-MultiCargo FMC

DIE TWIN HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 Hz

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Axially Split Case Pumps

Superstatic 440. Static Heat- and Cooling Meter. Application

Company name: Created by: Phone:

Pressure Boosting Systems Multiple-Pump Units

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Dewatering Submersible sewage pumps

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

Planning is simple: with Calio circulators for commercial buildings

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

m-csg Ultra-compact Clean Steam Generation System

Company name: Created by: Phone: Note! Product picture may differ from actual product

Premounted Midi Shunts

Lenntech GRUNDFOS DATA BOOKLET. CME 15. Horizontal, multistage centrifugal pumps 50/60 Hz

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SIE BV/ED EVS. SINGLE HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 et 60 Hz. operating limits SIE BV/ED

TPED /4-S-A-F-A-BAQE 3X400 50HZ

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Company name: Created by: Phone: Date: Note! Product picture may differ from actual product

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Series 240 Type 3351 Pneumatic On/off Valve

High pressure centrifugal pumps

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

Pressure independent balancing and control valve

Wilo-CronoLine-IL-E Wilo-CronoTwin-DL-E Wilo-CronoBloc-BL-E

Inline Pumps. Product review. Wilo-VeroLine-IPL. Single-head pumps: Single stage inline, flanged, long coupled, mechanical sealed dry rotor pump

WZMC-402 Ultrasonic Apartment Energy Meters

Transcription:

Series description: Wilo-Stratos H/m 16 14 12 1 8 6 4 2 25(3,32,4,5)/1-1 25(3)/1-8 25(3)/1-6 25(3)/1-4 5/1-12 4/1-4 4/1-12 32/1-12 4(5)/1-8 3/1-12 4/1-16 5/1-9 65/1-9 65/1-12 Wilo-Stratos 65/1-16 5/1-16 8(1)/1-12 1 2 3 4 5 6Q/m³/h Design Glandless circulation pump with threaded or flange, EC motor with automatic power adjustment. Application Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems. Type key Example: Wilo-Stratos 3/1-12 Stratos High-efficiency pump (screw-end or flange-end pump), electronically controlled 3/ Nominal diameter 1-12 Nominal delivery head range [m] Special features/product advantages Maximum efficiency due to ECM technology Front operation and access to terminal room, variable installation positions, display independent of position Simple installation due to PN 6/PN 1 combination flanges (with DN 32 to DN 65) Application possible in cooling/air-conditioning systems without ambient temperature limitation Pump housing with cataphoretic (KTL) coating to prevent corrosion due to condensation formation System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, CAN, LON, PLR etc. Remote control via infrared interface (IR stick/ir monitor) Technical data Permissible temperature range -1 C to +11 C Mains Protection class IP X4D Screwed or flange (depending on type) Rp 1 to DN 1 Max. operating pressure, standard version: 6/1 bar or 6 bar (special version: 1 bar or 16 bar) Equipment/function Operating modes Manual control mode (n=constant) Δp-c for constant differential pressure Δp-v for variable differential pressure Δp-T for temperature-controlled differential pressure (programmable via IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN) Manual functions Operating mode setting Differential pressure setpoint setting Setting automatic setback operation Pump ON/OFF setting Speed setting (manual control mode) Automatic functions Variable power adjustment depending on the operating mode Automatic setback operation Deblocking function Soft start Full motor protection with integrated trip electronics External control functions "Overriding Off" control input "Overriding Min" control input "Analogue In 1 V" control input (remote speed adjustment) "Analogue In 1 V" control input (remote setpoint adjustment) Signal and display functions Collective fault signal (potential-free NC contact) Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules) Fault signal light LC display for indication of pump data and fault codes Data exchange Infrared interface for wireless data exchange with IR-Stick/IR-Monitor Modbus RTU serial digital interface for to building automation BA via RS485 BUS system (possible with Stratos IF- Modules) BACnet serial digital interface MS/TP Slave for to building automation BA via RS485 BUS system (possible with Stratos IF- Modules) CAN serial digital interface for to building automation BA via CAN BUS system LON serial digital interface for to a LONWorks network PLR serial digital interface for to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules) Dual pump management (double pump or 2 x single pump) Main/standby operation (automatic fault-actuated switchover/timedependent pump cycling): various combinations with Stratos IF- Modules (accessories) possible Parallel operation (efficiency-optimised peak load activation and deactivation): various combinations with Stratos IF-Modules (accessories) possible Equipment Wrench attachment point at pump body (for threaded pipe union Subject to change without prior notice. www.wilo.co.uk 5 Hz EU 213-7 1 / 5

Series description: Wilo-Stratos pumps with P 2 < 1 W) For flange-end pumps: Flange versions Standard version for DN 32 to DN 65 pumps: PN 6/1 combination flange (PN 16 flange according to EN 192-2) for PN 6 and PN 16 counter flanges Standard version for DN 8/DN 1 pumps: PN 6 flange (designed for PN 16 according to EN 192-2) for PN 6 counter flange Special version for DN 32 to DN 1 pumps: PN 16 flange (according to EN 192-2) for PN 16 counter flange Plug-in position for optional extension with Wilo-IFModules Standard thermal insulation for heating applications Materials Pump housing: Grey cast iron with cataphoretic coating Thermal insulation: Polypropylene Shaft: stainless steel Bearing: Carbon, metal impregnated Impeller: Plastic Scope of delivery Pump Including thermal insulation Including seals for threaded Incl. washers for flange screws (for nominal diameters DN 32 DN 65) Including installation and operating instructions Options Special versions for operating pressure PN 16 Accessories Screwed for threaded Adapter fittings IR-Stick IR-Monitor Stratos IF-Modules: Modbus, BACnet, CAN, LON, PLR, DP, Ext. Off, Ext. Min., SBM, Ext. Off/SBM Subject to change without prior notice. www.wilo.co.uk 5 Hz EU 213-7 2 / 5

Duty chart: Wilo-Stratos Duty chart H/m 16 14 Wilo-Stratos p/kpa 16 14 12 5/1-12 12 1 4/1-16 1 8 4/1-12 25(3, 32, 4, 5)1-1 25(3)1-8 32/1-12 4(5)1-8 8 6 4 3/1-12 5/1-9 65/1-9 65/1-12 5/1-16 65/1-16 8(1)/1-12 6 4 2 25(3)1-4 25(3)1-6 4/1-4 2 1 2 3 4 5 6 Q/m³/h Subject to change without prior notice. www.wilo.co.uk 5 Hz EU 213-7 3 / 5

Product list: Wilo-Stratos Type Max. volume Max. Pipe Nominal Rated Overall Mains Gross Art no. flow delivery flange pressure length weight head diameter Q max / m 3 /h H max / m PN / bar l / mm m / kg Stratos 25/1-4 5 4 Rp 1 1 18 Stratos 25/1-4 5 4 Rp 1 16 18 Stratos 25/1-6 7 6 Rp 1 1 18 Stratos 25/1-6 7 6 Rp 1 16 18 Stratos 25/1-8 8 7 Rp 1 1 18 Stratos 25/1-8 8 7 Rp 1 16 18 Stratos 25/1-1 9 1 Rp 1 1 18 Stratos 25/1-1 9 1 Rp 1 16 18 Stratos 3/1-4 5 4 Rp 1¼ 1 18 Stratos 3/1-4 5 4 Rp 1¼ 16 18 Stratos 3/1-6 7 6 Rp 1¼ 1 18 Stratos 3/1-6 7 6 Rp 1¼ 16 18 Stratos 3/1-8 8 7 Rp 1¼ 1 18 Stratos 3/1-8 8 7 Rp 1¼ 16 18 Stratos 3/1-1 9 1 Rp 1¼ 1 18 Stratos 3/1-1 9 1 Rp 1¼ 16 18 Stratos 3/1-12 11 11 Rp 1¼ 1 18 Stratos 3/1-12 11 11 Rp 1¼ 16 18 Stratos 32/1-1 1 1 DN 32 6/1 22 Stratos 32/1-1 1 1 DN 32 16 22 Stratos 32/1-12 13 9 DN 32 6/1 22 Stratos 32/1-12 13 9 DN 32 16 22 Stratos 4/1-4 11 5 DN 4 6/1 22 Stratos 4/1-4 11 5 DN 4 16 22 Stratos 4/1-8 15 8 DN 4 6/1 22 Stratos 4/1-8 15 8 DN 4 16 22 Stratos 4/1-1 1 1 DN 4 6/1 22 Stratos 4/1-1 1 1 DN 4 16 22 Stratos 4/1-12 19 12 DN 4 6/1 25 5.5 214225 5.5 211661 5.5 29447 5.5 26597 5.5 29448 5.7 263363 5.5 213615 5.5 211156 6 214226 5.7 2131799 5.7 29449 6 26976 6 2945 6 269759 5.6 213616 5.6 2117648 7 29451 7.3 272567 9.1 213617 9.1 211124 11 29452 11 272566 9.9 29453 9.9 269142 1.5 29454 1.5 26864 9.3 213618 9.3 2113776 16.1 29455 Subject to change without prior notice. www.wilo.co.uk 5 Hz EU 213-7 4 / 5

Product list: Wilo-Stratos Type Max. volume Max. Pipe Nominal Rated Overall Mains Gross Art no. flow delivery flange pressure length weight head diameter Q max / m 3 /h H max / m PN / bar l / mm m / kg Stratos 4/1-12 19 12 DN 4 16 25 Stratos 4/1-16 23 17 DN 4 6/1 25 Stratos 5/1-8 15 8 DN 5 6/1 24 Stratos 5/1-8 15 8 DN 5 16 24 Stratos 5/1-9 24 9 DN 5 6/1 28 Stratos 5/1-9 24 9 DN 5 16 28 Stratos 5/1-1 1 1 DN 5 6/1 24 Stratos 5/1-1 1 1 DN 5 16 24 Stratos 5/1-12 29 11 DN 5 6/1 28 Stratos 5/1-12 29 11 DN 5 16 28 Stratos 5/1-16 43 17 DN 5 6/1 34 Stratos 65/1-9 29 11 DN 65 6/1 28 Stratos 65/1-9 29 11 DN 65 16 28 Stratos 65/1-12 41 1 DN 65 6/1 34 Stratos 65/1-12 41 1 DN 65 16 34 Stratos 65/1-16 52 16 DN 65 6/1 34 Stratos 8/1-12 62 13 DN 8 6 36 Stratos 8/1-12 62 13 DN 8 1 36 Stratos 8/1-12 62 13 DN 8 16 36 Stratos 1/1-12 62 13 DN 1 6 36 Stratos 1/1-12 62 13 DN 1 1 36 Stratos 1/1-12 62 13 DN 1 16 36 16.8 263362 25.5 2131666 12.6 29456 13.4 26974 17.6 29457 18 269363 1.8 213619 1.8 212729 18.6 29458 17.6 263361 28.5 2131667 19.5 29459 19.3 269362 31 2946 31 269739 31 2131668 35 287523 35 287524 35 263364 38 287525 38 287526 38 269578 Subject to change without prior notice. www.wilo.co.uk 5 Hz EU 213-7 5 / 5