Mounting Instructions D08X0 June 0 Use these instructions to mount a Fisher FIELDVUE DVC00 digital valve controller mounting kit for Universal (side mounting), sliding stem applications. WARNING Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any installation operations: Always wear protective clothing, gloves, and eyewear. Do not remove the actuator from the valve while the valve is still pressurized. Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the control valve. Use bypass valves or completely shut off the process to isolate the control valve from process pressure. Relieve process pressure from both sides of the control valve. Use lock out procedures to be sure that the above measures stay in effect while you work on the equipment. Check with your process or safety engineer for any additional measures that must be taken to protect against process media. Vent the pneumatic actuator loading pressure and relieve any actuator spring precompression so the actuator is not applying force to the valve stem; this will allow for the safe removal of the stem connector. Refer to figures, 8 and for mounting parts identification. Hex key,. hex, L-key flat end, long (key ) is to be used to secure the M hex socket button head screws (key ). Refer to the DVC00 digital valve controller instruction manual for digital controller parts identification. Refer to the appropriate actuator instruction manual for actuator installation, operation, maintenance, and parts identification. DVC00 Digital Valve Controller. Isolate the control valve from the process line pressure and release pressure from both sides of the valve body. Shut off all pressure lines to the actuator, releasing all pressure from the actuator. Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment.. Determine the stem diameter (must not be smaller than. mm (0. Inch) mm and not larger than. mm (.00 inch). Use the stem blocks and shims in the kit, drill out the stem block assembly to the actuator stem dimension (see figure ). Once desired diameter is reached, loosen the two stem block assembly screws and remove the shims. Figure. Stem Block Assembly MAX. BORE,. (.00) MIN. BORE,. (0.) SHIMS STEM BLOCK ASSEMBLED WHEN DRILLING SHIM STEM BLOCK HALF (FRONT) SHIM STEM BLOCK HALF (BACK) () SCREW, CAP, HEX SOCKET M8X.X mm (INCH). Attach the stem block to the stem, in relationship to the desired location of the mounting bracket (key ). Use the () M8x.x screws to secure the stem block to the stem in the predetermined position. www.fisher.com
DVC00 Digital Valve Controller Mounting Instructions D08X0 June 0 Figure. Rib Style Yoke Note. (.) MIN 0. (.) MAX When the stem is in either the fully open or fully closed position, the distance from the centerline of the mounting bracket (key ) and the centerline of the stem block assembly should not exceed (see figure ).. Revisit the desired location of the mounting bracket.. (.00) MIN. (.) MAX MUST HAVE CLEARANCE FOR STEM BLOCK ASSEMBLY Figure. Stanchion Style Yoke (.0) MIN. (.0) MAX mm (INCH) a. If actuator has a NAMUR rib (figure and ), verify the width of the yoke is a minimum of. mm (.00 inch) up to a maximum of. mm (. inch). Once this is verified, ensure the distance from the face of the mounting bracket (key ) to the mounting face of the stem block assembly is a minimum of. mm (. inch) and not more than 8. mm (.88 inch). Attach mounting bracket (key ) using either /-8 X. inch hex head screw(s) or M8 X. X mm hex head screw(s) (key 8)(see figure and ). b. If actuator has a stanchion style yoke, verify the width of the yoke is a minimum of.8 mm (.0 inch) up to a maximum of. mm (.80 inch). Once this is verified, ensure the distance from the face of the mounting bracket (key ) to the mounting face of the stem block assembly is a minimum of mm (.0 inch) and not more than 8. mm (.80 inch). Attach mounting bracket (key ) using M8x.xx U-bolts (key ) (see figures and 8). c. If actuator has a Plane Surface style yoke, verify the width of the yoke is a minimum of. mm (.0 inch) up to a maximum of. mm (.0 inch). Once this is verified, ensure the distance from the face of the mounting bracket (key ) to the mounting face of the stem block assembly is a minimum of. mm (. inch) and not more than 8. mm (.88 inch).. (.00) MIN. (.) MAX MUST HAVE CLEARANCE FOR STEM BLOCK ASSEMBLY mm (INCH) These holes can be tapped either for /-8 or M8 X. hardware. Attach the mounting bracket (key ) using either /-8 X. inch hex head screws or M8 X. X mm hex head screws (see figure ).
Mounting Instructions D08X0 June 0 DVC00 Digital Valve Controller Figure. Plane Surface Yoke 8. (.) MIN 0. (.) MAX 80 (.) MIN 0 (.0) MAX MUST HAVE CLEARANCE FOR STEM BLOCK ASSEMBLY mm (INCH). Ensure the actuator/valve stem connector mounting face is visually square with the actuator yoke legs.. Attach the connector arm (key ) to the stem connector using the two hex head cap screws (key ) and plain washers (key ), but do not tighten (see figure, 8 and ). See figure 0 through for the proper arrangement for your application.. Attach the adjustment arm (key ) to the connector arm (key ) with two M flange socket head machine screws (key ) securely but do not tighten to maintain adjustability (see figure, 8 and ). 8. Attach the magnet assembly (array) (key ) to the extension arm (key ) with two M flange socket head machine screws (key ) securely but maintain adjustability (see figure, 8 and ).. Attach the extension arm (key ) and the magnet assembly (array) (key ) to the adjustment arm (key ) using two M flange socket head machine screws, (key ) securely but maintain adjustability. The next step will ensure that the connector arm (key ) selected is suitable (see figure ). Figure. Connector Arm Selection Figure. Mounting Holes (A) (B) A) CONNECTOR ARM FOR LARGER SIZE ACTUATORS B) CONNECTOR ARM FOR SMALLER SIZE ACTUATORS (.) () M8X. OR /-8 (.) ARRAY FIGURE SHOWS MAGNET ASSEMBLY MARKING ALIGNED WITH SENSOR INDEX MARK FOR AIR-TO-EXTEND ACTUATORS ASSEMBLY MARKING mm (INCH) ALIGNMENT TEMPLATE
DVC00 Digital Valve Controller Mounting Instructions D08X0 June 0 0. Attach the black plastic alignment template (see figure ) to the mounting bracket assembly by inserting the two protruding posts into the two recessed mounting holes in the bracket and simultaneously position the magnet assembly (array) so that it can slide into the channel in the alignment bracket. The magnet assembly (array) should be fully in the alignment template channel so that the extension arm is contacting the back of the alignment template but not bending it. Tighten the hex head cap screws (key ) at the stem connector and pan head machine screws (key ) attaching the extension arm to the connector arm but do not yet tighten the pan head machine screws attaching the magnet assembly (array).. For an air-to-extend actuator, slide the magnet assembly (array) (key ) so that the bottom marking aligns with the sensor index mark on the alignment template (figure ). The top marking of the magnet assembly (array) is used for air-to-retract. The mounting bracket (key ) may require vertical repositioning to get the magnet assembly (array) (key ) in the correct location. When the magnet assembly (array) (key ) is properly positioned, remove the alignment template (see figure ) and tighten the two pan head machine screws (key ).. Attach the digital valve controller to the mounting bracket assembly and tighten the three hex head cap screws (key 0) (see figure, 8 and ).. Check the position of the magnet assembly (array) (key ) in the channel of the digital valve controller housing and ensure that it is visually centered between the channel walls and has adequate clearance with the backside of the channel (approximately mm).. Connect and calibrate the digital valve controller as described in the instruction manual or quick start guide. For additional information concerning the mounting, setup, calibration and maintenance of the DVC00 digital valve controller, refer to the appropriate instruction manual or quick start guide.
Mounting Instructions D08X0 June 0 DVC00 Digital Valve Controller Figure. Mounting on Actuator with NAMUR Rib Yoke 8 0 PARTS LIST DVC00 ITEM 8 0 QTY 0 0 DESCRIPTION UNIV_RIB-YOKE WASHER, LOCK M8 ARM, ADJUSTMENT SCREW, CAP HEX SOCKET MX0.X0 FLANGED BUTTON BRACKET, MOUNTING ARM, EXTENSION ARM, CONNECTOR (CHOOSE ONE) SCREW, CAP HEX HD M8X.X OR /-8X. WASHER, PLAIN M SCREW, CAP, HEX HD M8X.X SCREW, CAP, HEX HD MXX FEEDBACK ARRAY NOT USED THIS VIEW NOT USED THIS VIEW HEX, KEY. HEX, L-KEY FLAT END LONG
DVC00 Digital Valve Controller Mounting Instructions D08X0 June 0 Figure 8. Mounting on Actuator with Stanchion Style Yoke 0 PARTS LIST DVC00 ITEM 8 0 QTY 0 0 DESCRIPTION UNIV_PILLAR-YOKE WASHER, LOCK MM8, X.X.0 ARM, ADJUSTMENT SCREW, CAP HEX SOCKET MX0.X0 FLANGED BUTTON BRACKET, MOUNTING ARM, EXTENSION ARM, CONNECTOR (CHOOSE ONE) NOT USED THIS VIEW WASHER, PLAIN M SCREW, CAP, HEX HD M8X.X SCREW, CAP, HEX HD MXX FEEDBACK ARRAY U-BOLT M8X. NUT, HEX M8X.-H HEX, KEY. HEX, L-KEY FLAT END LONG
Mounting Instructions D08X0 June 0 DVC00 Digital Valve Controller Figure. Mounting on Actuator with Plane Surface Style Yoke 8 0 DVC00 ITEM 8 0 QTY 0 0 PARTS LIST DESCRIPTION UNIV_PLANE-SURF-YOKE WASHER, LOCK M8 or / ARM, ADJUSTMENT SCREW, CAP HEX SOCKET MX0.X0 FLANGED BUTTON BRACKET, MOUNTING ARM, EXTENSION ARM, CONNECTOR (CHOOSE ONE) SCREW, CAP, HEX HD M8X.X OR /-8X. WASHER, PLAIN.XX. SCREW, CAP, HEX HD M8X.X SCREW, CAP, HEX HD MXX FEEDBACK ARRAY NOT USED THIS VIEW NOT USED THIS VIEW HEX, KEY. HEX, L-KEY FLAT END LONG
DVC00 Digital Valve Controller Mounting Instructions D08X0 June 0 Figure 0. MIN. (.80) MAX. (.80) MINIMUM AND MAXIMUM OF ARM ADJUSTMENT 8. (.). (.). (0.0) MAX AND MIN BRACKET A (SEE FIGURE ). (0.8) (.8) MAX AND MIN BRACKET B (SEE FIGURE ). (.8) mm (INCH) 8
Mounting Instructions D08X0 June 0 DVC00 Digital Valve Controller Figure. STEM CONNECTOR ARM A OR B (SEE FIGURE ) SCREW, CAP, HEX SOCKET (KEY ) STEM BLOCK ASSEMBLY (SEE FIGURE ) ARM, ADJUSTMENT (KEY ).8 (0.0) 8. (.). (.) 8. (0.) (.) 8. (.0) 0. (.). (.) 8. (0.). (0.) ARM EXTENSION MAX UP. (.0) ARM EXTENSION MAX DOWN ARM, EXTENSION (KEY ) mm (INCH) Figure. STEM. (.) (.) STEM BLOCK ASSEMBLY (SEE FIGURE ). (.) 8.8 (.). (.). (.8) 8. (.). (.) ARM, ADJUSTMENT (KEY ) ARM EXTENSION MAX UP CONNECTOR ARM A OR B (SEE FIGURE ) ARM, EXTENSION (KEY ) ARM EXTENSION MAX DOWN SCREW, CAP, HEX SOCKET (KEY ) mm (INCH)
DVC00 Digital Valve Controller Mounting Instructions D08X0 June 0 Figure. STEM. (.) (.). (0.) STEM BLOCK ASSEMBLY (SEE FIGURE ). (.8) MAX 0. MAX (.00). (0.) 0. (0.) 8.8 (0.). (.). (.) ARM, ADJUSTMENT (KEY ) CONNECTOR ARM A OR B (SEE FIGURE ) SCREW, CAP, HEX SOCKET (KEY ) ARM EXTENSION (KEY ) TURNED OVER MAX UP ARM, EXTENSION (KEY ) ARM EXTENSION (KEY ) TURNED OVER MAX DOWN mm (INCH) Figure. STEM CONNECTOR ARM A OR B (SEE FIGURE ) SCREW, CAP, HEX SOCKET (KEY ) STEM BLOCK ASSEMBLY (SEE FIGURE ). (.) 8.8 (.). (.) ARM, ADJUSTMENT (KEY ). (.) 0 (.8). (.). (0.). (.). (.) CONNECTOR ARM A OR B TURNED OVER MAX UP ARM, EXTENSION (KEY ) CONNECTOR ARM A OR B TURNED OVER MAX DOWN 0
Mounting Instructions D08X0 June 0 DVC00 Digital Valve Controller Figure. PLANE SURFACE YOKE (SEE FIGURE AND ) STEM BLOCK ASSEMBLY (SEE FIGURE ) BRACKET MOUNTING (KEY ). (.0) MAX UP 8.88 (.0) MAX DOWN MAXIMUM UP & DOWN BASED ON 00 mm MAGNET ASSEMBLY (ARRAY) mm (INCH)
DVC00 Digital Valve Controller Mounting Instructions D08X0 June 0 Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. HART is a mark owned by the HART Communication Foundation. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 08 USA Sorocaba, 808 Brazil Chatham, Kent ME QZ UK Dubai, United Arab Emirates Singapore 8 Singapore www.fisher.com 0 Fisher Controls International LLC. All rights reserved.