Index - Section 40L. Large Sump or Drainage Pumps. Bulletin Bulletin 4500

Similar documents
Index - Section 14 End Suction Pump Semi-Open Impeller

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Parts for Fig. 4565, 4566 & 4568 Industrial Section 40L Bulletin 95. Repair Parts.

G2C and G2S Series Vertical Cantilever and Sump Pumps

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Goulds Process Pumps designed for severe corrosive services

Fire Protection. FP-XA End Suction

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

Series: ES. 4ES RPM - 60Hz. ES RPM - 60Hz. (See Indivdual curves for symbol number)

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

MAXIMUM RECOMMENDED RPM NUMBER OF GUIDE BEARINGS FOR PIT DEPTHS TO 19' - 6" ADDITIONAL HP REQUIREMENTS FOR PUMP WITH INTERMEDIATE GUIDE BEARINGS

1100 Series Multi-Stage Vertical Turbine Pumps

Regenerative Turbine Pumps

320 Series Vertical Sump Pumps

Regenerative Turbine Pumps

Basic Hydraulic Features

DEMING. INSTALLATION, OPERATION & MAINTENANCE MANUAL Vertical Sump & Industrial Pumps

Bulletin D51 September D51 D61 D71 D91 Series. Centrifugal Pumps. Capacities to 240 GPM Heads to 360 Feet MTH PUMPS

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

Centrifugal End Suction Fire Pumps

Series: CT. 4CT RPM - 60Hz. CT RPM - 60Hz. (See Indivdual curves for symbol number)

M50 L50 Series Multistage Regenerative Turbine Pumps

DESIGN FEATURES SPECIAL DESIGN FEATURES. Space Saving. Self Priming. Easy to install. Design Flexibility

PROCESS PUMPS MODEL V200 ANSI B73.2

EN. 850 Filtrate Pumps. Technical Specification Pages

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Series: ES. 4ES RPM - 60Hz. ES RPM - 60Hz. (See Indivdual curves for symbol number)

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Regenerative Turbine Pumps

Regenerative Turbine Pumps

Series 8SHDU. Specifications: Series: 8SHDU 25-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3.50" Spherical Solids Handling

Regenerative Turbine Pumps

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

CALCULATION OF BOWL HEAD OR DISCHARGE HEAD

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

Series: GNA5-1-1/4, GNA6-1-1/4

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

4500C Series Vortex Pumps

Series 6SHV. Specifications: Series: 6SHV 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

D51 D61 D71 D91 Series

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

SJP Vertical Propeller Pumps

SUGGESTED SPECIFICATIONS

Series: ET. 4ET RPM - 60Hz. ET RPM - 60Hz. (See Indivdual curves for symbol number)

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

BSM ROTARY GEAR PUMPS

Series: ET. 4ET RPM - 60Hz. ET RPM - 60Hz. (See Indivdual curves for symbol number)

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

Quality Value Assurance

Engineers Without Borders

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

CLOSED COUPLED CENTRIFUGAL PUMPS

AURORA 3500 SERIES MODEL 3550 ASME/ANSI B73.1 INDUSTRIAL PROCESS PUMPS

VSC /VSCS Pumps Technical Brochure

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

Trash- and Solids-Handling Centrifugal Pumps Series 2100 Quality Design Features Assure Long, Trouble-Free Service

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Fybroc Vertical Turbine Pumps

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

B. OTHER SUBMERSIBLE DEWATERING PUMPS

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

BSM ROTARY GEAR PUMPS

SERIES CS CLOSE COUPLED TURBINE PUMPS

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Contents Project: Model: Chk d: Date:

Bulletin BX-420C Bell & Gossett. VSC /VSCS Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Program

High Temperature Chemical Process Inline Pumps

RS Multi-Stage, Ring Section Pumps

CLOSED COUPLED CENTRIFUGAL PUMPS

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

Goulds Small Capacity Double Suction Pump

SERIES CS CLOSE COUPLED TURBINE PUMPS

SECTION H3 TRAYMASTER SERIES DEAERATORS

AURORA Series MODEL 3560 ASME/ANSI B73.1M INDUSTRIAL PROCESS PUMPS

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Six-Inch Submersible Pumps

SAMPLE SPECIFICATIONS

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE:

SECTION H4 BOILERMATE DEAERATORS

CRANE-DEMING VERTICAL IN-LINE INDUSTRIAL BULLETIN 3180 SECTION 38

Series

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

NECO Pumping Systems

Vertical Pumps for the Oil & Gas Industry

Transcription:

www.cranepumps.com Index - Section 40L ITEM S Typical Architect / Engineer Specifi cations - 4500 Series... 1 Guide Bearing and Shaft Selection 4500 Series... 2 Shaft and Guide Bearing Assemblies 4500 Series... 3-4 Pump Selection Data... 5 Pump Assembly, Fig. 4501, 4511, & 4521... 6 Pump Dimensions - Fig. 4501, 4511 & 4521, Simplex Units... 7 Pump Dimensions - Fig. 4501, 4511 & 4521, Duplex Units... 8 Pump Dimensions - Fig. 4560, Simplex Units... 9 Pump Dimensions - Fig. 4560, Duplex Units... 10 Selection Curves, Fig. 4500, 3500RPM, 1750RPM, 1150RPM, & 870RPM... 11-12 Performance Curves, Fig. 4511, Sizes: 1¼S & 1½S, 1150RPM... 13 Performance Curves, Fig. 4511, Sizes: 1½M & 2S, 1150RPM... 14 Performance Curves, Fig. 4511, Sizes: 2M & 3S, 1150RPM... 15 Performance Curves, Fig. 4511 & 4521, Sizes: 3MD & 1½L, 1150RPM... 16 Performance Curves, Fig. 4521, Sizes: 4MD & 5MD, 1150RPM... 17 Performance Curves, Fig. 4521, Sizes: 5MSD & 6MD, 1150RPM... 18 Performance Curves, Fig. 4521, Sizes: 6MLD, 1150RPM... 19 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 4x4x12 DV & 6x4x12 DV, 1150RPM... 20 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 6x6x12 DV & 8x6x12 DV, 1150RPM... 21 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 8x8x12 DV & 10x10x12 DV, 1150RPM... 22 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 10x10x12 DV, 870RPM... 23 Performance Curves, Fig. 4501, Sizes: 1" & 1½", 1750RPM... 24 Performance Curves, Fig. 4501 & 4511, Sizes: 2½" & 1¼S, 1750RPM... 25 Performance Curves, Fig. 4511, Sizes: 1½S & 1½M, 1750RPM... 26 Performance Curves, Fig. 4511, Sizes: 2S & 2M, 1750RPM... 27 Performance Curves, Fig. 4511, Sizes: 3S & 3MD, 1750RPM... 28 Performance Curves, Fig. 4521, Sizes: 4MD & 5MD, 1750RPM... 29 Performance Curves, Fig. 4511 & 4521, Sizes: 4S & 5MS, 1750RPM... 30 Performance Curves, Fig. 4521, Sizes: 5MSD & 6MD, 1750RPM... 31 Performance Curves, Fig. 4521, Size: 6MLD & 1½L, 1750RPM... 32 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 4x4x12 DV & 6x4x12 DV, 1750RPM... 33 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 6x6x12 DV & 8x6x12 DV, 1750RPM... 34 Performance Curves, Fig. 4565, 4566 & 4568, Sizes: 8x8x12 DV, 1750RPM... 35 Performance Curves, Fig. 4511H, Sizes: 1" & 1½", 3500RPM... 36 Performance Curves, Fig. 4511H, Sizes: 1¼S & 1½S, 3500RPM... 37 Performance Curves, Fig. 4511H, Sizes: 2S & 3MD, 3500RPM... 38 WARNING: CANCER AND REPRODUCTIVE HARM - WWW.P65WARNINGS.CA.GOV

www.cranepumps.com This page intentionally left blank

Typical Architect/Engineers Specifications Series: 4500 www.cranepumps.com General Furnish and install, as shown on the plans Deming Fig. 4500 Series Heavy Duty Vertical Sump Pumps, each pump to be capable of pumping GPM when operating against a total pumping head of feet at temperature, specifi c gravity and viscosity indicated. Each pump shall operate at RPM and shall have percent effi ciency at the design point. Shut-off head shall be not less than feet. Pump shall be (clockwise)(counter-clockwise) rotation when viewed from the driver. The unit shall be designed for installation in a sump feet deep and furnished with (above)(below) plate discharged of size indicated. Construction Details The pump liquid end including casing, impeller, suction head, strainer and bearing housing shall be of cast iron having minimum tensile strength of 30,000 lbs. Impeller shall be semi-open type secured to shaft with key, washer and lock nut and shall be fully adjustable, without dismantling the pump, by means of an adjusting nut located above the thrust bearing in the motor support. Flanged column pipe shall be full weight steel pipe with a machined register fi t at all assembly points to assure concentric alignment. Pump shaft shall be of a high grade carbon steel of suffi cient size to transmit required horsepower. Replaceable shaft guide bearings, of material suitable for the liquid being pumped, shall be contained in precision machined bearing housings; fl anged for machined register fi t in column pipe fl anges and spaced on recommended bearing centers, but not to exceed 5-foot centers. Bottom bearing assembly shall include choker ring. Suitable lubrication shall be provided to each shaft guide bearing.cast iron motor support, mounted on heavy steel support plate, shall align the motor with column pipe and shafting. High capacity ball thrust bearing, in waterproof housing, shall be mounted in the motor support. Bearing shall be grease lubricated with provision for purging old grease from bearing housing. The pump assembly shall include a heavy steel support plate inches diameter, for mounting on a pit inches diameter. Pump discharge pipe shall extend above the plate and shall be supported from the plate by two lock nuts. Duplex pump sump cover shall include a manhole 11 x 15 inches, or larger with cover and with inch (fl anged)(threaded) vent connection. Control For single pump, a suitable fl oat switch shall be mounted on support plate and shall be operated by a guided corrosion resisting fl oat. Switch shall operate motor directly or with starter, as required. For duplex pumps, supply mechanical or electric alternator and control which will alternate the normal operation of the two pumps, operate both pumps simultaneous, if required, and provide standby control should one pump become inoperative. Motor The motor shall be not less than hp RPM, NEMA design B squirrel cage type, (drip proof)(tefc) (EISA)(premium) effi ciency motor with (1.15)(1.0) service factor and suitable for operation on (115)(230) volt, 1 phase, (50)(60) Hertz power supply OR (200)(230)(460) (575) volt, 3 phase, 60 hertz power supply. Motor size shall be suffi cient to prevent overloading at operating conditions or at the lowest listed head conditions, whichever point requires greater horsepower. Following installation, grouting and connection of all piping, pump and motor must be checked for alignment in accordance with standards of the Hydraulic Institute. 1 10/18

Guide Bearing and Shaft Selection 4500 Series The proper selection of guide bearing assembly, column closure and shaft material is essential for the successful operation of Vertical Sump and Process Pumps, due to the variety of liquids that may be encountered at the point of installation. www.cranepumps.com DEMING offers a wide choice of bearing construction and shaft materials to meet requirements of most installations. Listed below are recommendations for the proper selection of these important items. Type of Service General Clean Liquids Acids (clean) Alkaline Caustic Chemical Mild Abrasive General Abrasives Molten Sulphur Nuclear Typical Application BEARING SELECTION Maximum Recommended Operating Temperature 400 F Bearing Material Max. Liquid Temp F BHN Clean Liquid (1) Recommended Lubrication Grease (2) Dry (3) Abrasion Resistance of Bearing when used in Bearing Assembly Indicated Fair Good Best Furnished on Standard Fitted and Bronze Fitted Pumps Bronze 180 57/64 NR R NR 6 & 8 11 NR Cold or Hot Water, Sea Water, Babbit- Cleaning Fluids, Gasoline, Graphite* Kerosene, Jet Fuels 300 19 R NR R NR NR NR Most Acids - Max., 60% Sulfuric Carbolube* 400 237 R NR R 6 & 8 11 NR Most Acids - Max., 100% Sulfuric Nickel Graphite* 400 -- R NR R NR NR NR Sodium Hydroxide, etc. Class 30 Standard on All Iron Pumps Cast Iron 180 160 NR R NR 6 & 8 11 NR General Service with most clean Acids and Solvents Tefl on * 350 -- R R NR 10 NR NR General Service with Compatible Liquids Cast Iron 180 180 NR R NR NR 6 & 8 11 Used in Compatible Liquids except Rubber * Concentrated Acids and Solvents (Buna) 150 -- R NR NR NR NR 12 Used as bottom bearing with Babbit- Carbolube Intermediate Bearing Graphite* 360 220 NR NR R NR NR 6 Demineralized Water Nickel Graphite * 400 -- R NR R 6 & 8 11 NR (*) Requires Type 416, Carp. 20 or 316 Stainless Steel Shaft. R - Recommended NR - Not Recommended Important! - Pump Should be Minimum 1 HP. Note: (1) Clean liquid fl ush to bearing requires approx. ½ gpm per bearing at pressure equal to or greater than ½ of the pump discharge pressure. Solenoid valve is required. (2) Standard grease lubricated pump includes grease fi tting on lube line to each bearing assembly. Spring loaded grease cup optional when specifi ed. (3) Bearings indicated for dry lubrication are lubricated by the liquid being pumped. (4) Add ½ hp per Intermediate Bearing. RECOMMENDED SHAFT MATERIALS Listed below is genera recommendation of shaft materials for various types of chemical service Shaft Material Brinell Hardenss Application 4140 SAE Steel 163 General Service - Furnished in standard fi tted pumps 416 Stainless Steel 207-241 General Service in mild acids and chloride solutions 316 Stainless Steel 135-185 Industrial chemicals, solvents, chlorides, brines and most acids Carp. 20 Stainless Steel 160 Most active acids except those requiring Hastelloy or other metals For specifi c applications, contact Factory with full information. 2 4/08

www.cranepumps.com Shaft and Guide Bearing Assemblies 4500 Series DESIGN 1 - TOP STANDARD SHAFT GUIDE BEARING ASSEMBLIES For standard drainage service - non-corrosive liquids without abrasives or vapors. Normally furnished with pressurized grease lubrication with bearings of Bronze or Cast Iron. For pressurized liquid lubrication, specify Babbit-Graphite, Nickel Graphite or Carbolube bearing material. If liquid being pumped is compatible, it may be used to lubricate the bearing. DESIGN 8 - INTERMEDIATE Design 1 is the standard cast iron column top closure. On Standard Fitted and All Iron pumps, it is of Fianite material. On alloy pumps, it will be of the same material as the liquid end parts DESIGN 6 - BOTTOM Design 8 is the standard intermediate shaft guide bearing assembly including two guide bearings of the material as selected. Used where pit depth is greater than 6 ft. For pressurized grease lubrication, specify bearings of Bronze or Cast Iron. Design 6 is the standard bottom shaft guide bearing assembly with choker ring and two guide bearings of the material selected. For pressurized liquid lubrication, specify Babbit-Graphite, Nickel Graphite or Carbolube bearing material. If liquid being pumped is compatible, it may be used to lubricate the bearing. When pumping abrasive, corrosive or hot liquids, the standard construction as shown above must be modifi ed to meet the FOR SPECIAL APPLICATIONS requirements of the particular installation. Shown below are recommendations for specifi c applications. DESIGN 3 - TOP ALTERNATE TOP COLUMN CLOSURE DESIGN 5 Design 3 top closure is used instead of Design #1 and is recommended to seal the shaft when gas or obnoxious vapors are present in the liquid. Includes three rings of packing and lantern ring. May be grease lubricated or liquid flushed. Has 1/8" inlet and outlet connections. Top closure is also used in place of Design #1 and is recommended for containment of hot or corrosive vapors, high pumping pressures, abrasives and with pressurized column assembly. Includes five rings of packing and lantern ring. May be grease lubricated or liquid flushed. Has 1/8" connections. 3 4/08

Shaft and Guide Bearing Assemblies 4500 Series www.cranepumps.com ALTERNATE GUIDE BEARING ASSEMBLIES BOTTOM OR INTERMEDIATE FOR SLIGHTLY ABRASIVES LIQUIDS FOR ABRASIVE LIQUIDS DESIGN 11 includes bearings of the material selected, fi ve rings of packing under spring tension plus choker ring in bottom of the housing to form a seal to exclude abrasives from the bearings. For pressurized grease lubrication, specify bearing of Bronze or Cast Iron. DESIGN 12 is recommended for abrasive liquids and includes two rubber bearings separated by lantern ring for fl ush connection. Requires pressurized liquid lubrication. For installation requiring maximum protection against abrasives, refer full information to Factory. For pressurized liquid lubrication, specify bearings of Babbit Graphite, Nickel Graphite or Carbolube. FOR CHEMICAL SERVICE DESIGN 10 includes Teflon bearing with lock screw and is lubricated by the liquid being pumped, or may be pressured with compatible liquid. 4 4/08

www.cranepumps.com Pump Selection Data 4500 Series Pump Selection Data Total Pumping Head: Often overlooked in selecting vertical pumps that take suction from open sumps is the need to add the losses in the sump below the mounting plate to the head above the mounting plate to determine the total pumping head for selecting the pump. These additions include the elevation from the lowest liquid in the sump to the support plate plus friction loss in the discharge elbow and discharge pipe plus velocity head in the discharge pipe to the support plate. The pump characteristic curves indicate the pump performance measured at the casing discharge fl ange; therefore in selecting the pump size and motor horsepower, the total pumping head must include the data as above. Example of Total Head Calculations: Pump required - 400 GPM, Pit depth 10'-6", lowest liquid level 7ft. below support plate, highest point in discharge line 38ft., pressure required at the discharge 8 p.s.i., friction loss in 4" discharge line beyond the pump 4 ft. Highest Elevation...38 ft. Pressure Required 8 p.s.i. x 2.31...18.48 ft. Friction Loss - Discharge line...4 ft. Lift in Sump...7 ft. Friction in elbow and discharge pipe...2.05 ft. Velocity head in pump discharge pipe...1.58 ft. Total Pumping Head...71.11 ft. Normally the "pit depth" can be substituted to compensate for the low liquid level and pipe losses below the support plate; when added to the pumping head above the pump, this will give the approximate total pumping head for selecting the pump. When the capacity and the total pumping head are specifi ed by the customer, it will be assumed that the total pumping head includes all friction losses and velocity head beyond the pump casing plus allowance for lowest liquid level in the sump; otherwise the indicated total pumping head must be corrected as above. Minimum Submergence: The distance from the surface of a liquid in a sump or tank to the pump suction inlet is known as submergence. Depending on the pump size, a "minimum submergence" is required to prevent vortex formation around the pump suction which will reduce pump capacity and may cause pump damage and rapid wear. Submergence should not be confused with Net Positive Suction Head or NPSH. It is possible to have sufficient submergence but insuffi cient net positive head or vice versa depending on the installation and liquid characteristics. Proposed installations must be checked for both required submergence and available NPSH to be sure they are equal to or greater than that required by the pump. The table below shows minimum submergence above the pump suction nozzle in 65 F water, where pump is fi tted with standard strainer and where tank liquid velocity is negligible. Omission of pump strainer, liquid velocity, sump obstructions or other pumps installed in the same sump may require greater submergence. Minimum Submergence Above Suction Nozzle Figure 4501-4511 - 4521 Pump Size 1 1½ 2½ 1¼ S 1½ S 1½ M 1½ L 2 S 2 M Min. Subm. 18" 18" 18" 18" 18" 18" 18" 18" 18" Pump Size 3 S 3 MD 4 S 4 MD 5 MSD 5 MD 6 MD 6 MLD Min. Subm. 24" 24" 24" 24" 24" 24" 24" 24" Figure 4565-4566 - 4568 Pump Size 4 x 4 x 12 6 x 4 x 12 6 x 6 x 12 8 x 6 x 12 8 x 8 x 12 10 x 10 x 12 Min. Subm. 8" 20" 24" 30" 36" 36" 5 3/08

Pump Assembly - Fig. 4501, 4511, & 4521 4500 Series www.cranepumps.com Item No. 1 2 6A 6 9 * 18 19 23 * 24 32 33 * 39 * 39A 42 44 46 48 66 70 * 73 101 101A 105 161 * 169 * 169A 170 199 202 216 219 226 241 242 244 246 247 * 250 * 254 256 257 258 260 265 267 268 270 277 285 288 294 295 307 316 332 335 * 336 341 342 350 351 Name Of Part Casing Impeller Top Shaft Bottom Shaft Suction Cover Ball Bearing Frame Base Plate Impeller Nut Impeller Key Bearing Housing Bearing Bushing Top Bearing Bushing Coupling Half - Pump Coupling Half - Driver Coupling Key Coupling Bushing Shaft Adjusting Nut Shaft Coupling Gasket Column Top Column Pipe Discharge Elbow Discharge Fitting Seal - Lower Seal - Top Bearing Adapter Top Closure Snap Ring Pipe Plug Cap Screw Cap Screw (Not Shown) Gasket Grease Fitting Brg. Adapter Key Stud Hex Nut Frame Gasket Pipe Nut Gasket Hex Nut Choker Ring Hex Nut Cap Screw Cap Screw Cap Screw Hex Nut Impeller Washer Cap Screw Cap Screw Hex Nut Pipe Nut Discharge Flange Bearing Retainer Strainer Cap Screw Lube Pipe Assembly Gasket Hex Nut Set Screw Stud Hex Nut * Recommended spare parts WARNING: CANCER AND REPRODUCTIVE HARM - WWW.P65WARNINGS.CA.GOV 6 10/18

www.cranepumps.com All Sizes - Figs. 4501, 4511 & 4521 Simplex Units FRAME 56C 143TC 145TC 182TC 184TC 213TC 215TC 254TC 256TC 284TC 286TC 324TC D 23⅞ 22½ 23½ 25⅞ 26⅞ 27 9 16 29 1 16 31 5 16 33 1 16 36 13 16 38 5 16 39⅜ FRAME 326TC 364TSC 365TSC 404TSC D 40⅞ 41⅜ 42⅜ 43⅞ FIG. SIZE MAX. SOLIDS 4501-1 ⅜ Solids A B C E F G H J K L M P Y Z U 1½ 24 2 FT. TO 20 FT. IN 6 IN. MULTIPLES 28 26 3 4 8⅝ 6⅝ 7⅛ 4 ⅜ 13 3⅜ 4501-1½ 2 24 28 26 3 4¼ 10½ 6⅜ 8¾ 4 ⅜ 13 3⅛ 11 16 Solids 2½ 24 28 26 3 4¼ 12 6⅜ 9⅜ 4 ⅜ 13 3¾ 2½ 24 28 26 3 5½ 13 4⅝ 10⅜ 4 ⅜ 13 3¾ 4501-2½ 1 1 16 Solids 3 24 28 26 3 5½ 14 4⅝ 11¼ 4 ⅜ 13 3⅞ 4 24 28 26 3 5½ 15⅞ 4⅝ 13¼ 4 ⅜ 13 4¼ 4511-1¼S 1½ 24 28 26 3 5⅛ 10⅜ 4⅞ 8⅞ 4 ⅜ 13 3⅜ 5 16 Solids 2 24 28 26 3 5⅛ 11⅛ 4⅞ 9⅜ 4 ⅜ 13 3⅛ 4511-1½S 2 24 28 26 3 5⅛ 11⅛ 4¾ 9⅜ 4 ⅜ 13 3⅛ 7 16 Solids 2½ 24 28 26 3 5⅛ 12⅝ 4¾ 10 4 ⅜ 13 3¾ 4511-1½M 7 16 Solids 4511-2S 11 16 Solids 4511-2M 11 16 Solids 4511-3S 1 3 16 Solids 4511-3MD 1 3 16 Solids 4511-4S 15 16 Solids 4521-1½L 7 16 Solids 4521-4MD 1 3 16 Solids 4521-5MD 1⅛ Solids 4521-5MSD 1 9 16 Solids 1½ 24 28 26 3 6⅜ 11⅞ 6⅛ 10⅜ 4 ⅜ 13 3⅜ 2 24 28 26 3 6⅜ 12¼ 6⅛ 10½ 4 ⅜ 13 3⅛ 2½ 24 28 26 3 6⅜ 13⅞ 6⅛ 11¼ 4 ⅜ 13 3¾ 3 24 28 26 3 6⅜ 15¼ 6⅛ 12½ 4 ⅜ 13 4½ 2 24 28 26 3 5⅞ 11¾ 4½ 10 4 ⅜ 13 3¼ 2½ 24 28 26 3 5⅞ 13⅜ 4½ 10¾ 4 ⅜ 13 3¾ 3 24 28 26 3 5⅞ 13⅞ 4½ 11⅛ 4 ⅜ 13 3⅞ 2 24 28 26 3 6⅝ 13 5⅞ 11¼ 4 ⅜ 13 3¼ 2½ 24 28 26 3 6⅝ 14½ 5⅞ 11⅞ 4 ⅜ 13 3¾ 3 24 28 26 3 6⅝ 15 5⅞ 12¼ 4 ⅜ 13 3⅞ 4 24 28 26 3 6⅝ 16⅞ 5⅞ 14¼ 5 ⅜ 13 4⅜ 3 24 28 26 3 6 15 3⅞ 12¼ 4 ⅜ 13 5 4 24 28 26 3 6 15⅝ 3⅞ 12¼ 4 ⅜ 13 4⅜ 3 30 34 32 3 7⅛ 16¼ 4⅝ 13½ 6 ⅜ 16 5 4 30 34 32 3 7⅛ 16⅞ 4⅝ 13½ 6 ⅜ 16 4⅜ 4 30 34 32 3 7 17 3⅛ 13⅝ 6 ⅜ 16 5¼ 5 30 34 32 3 7 17⅝ 3⅛ 13⅝ 6 ⅜ 16 5⅛ 6 30 34 32 3 7 18¼ 3⅛ 13⅝ 6 ⅜ 16 5⅝ 1½ 24 28 26 4 7⅜ 13¼ 7⅝ 11¾ 4 ⅜ 13 3⅞ 2 24 28 26 4 7⅜ 13¾ 7⅝ 12 4 ⅜ 13 3⅛ 2½ 24 28 26 4 7⅜ 15¼ 7⅝ 12⅝ 4 ⅜ 13 3¾ 3 30 34 32 4 7⅜ 16⅝ 7⅝ 13⅞ 6 ⅜ 16 4½ 4 30 34 32 4 7½ 19 4 15⅝ 6 ⅜ 16 5¼ 5 30 34 32 4 7½ 19⅝ 4 15⅝ 6 ⅜ 16 5¼ 5 36 40 38 4 8⅜ 19¾ 3⅞ 15¾ 6 ½ 19 5⅜ 6 36 40 38 4 8⅜ 20⅜ 3⅞ 15¾ 6 ½ 19 5½ 5 36 40 38 4 8⅜ 19¾ 3⅞ 15¾ 6 ½ 19 5⅜ 6 36 40 38 4 8⅜ 20⅜ 3⅞ 15¾ 6 ½ 19 5½ 1¼ 1½ 4521-6MD & 6MLD 1⅜ Solids 6MD 1 9 16 Solids 6MLD 6 36 40 38 4 9⅞ 20⅞ 3¾ 16¼ 6 ½ 19 5½ 8 36 40 38 4 9⅞ 22⅞ 3¾ 17 6 ½ 19 6⅛ 1" through 2½" discharge pipe furnished with pip coupling, 3" and larger are furnished with a 125# companion fl ange. Customer Shop Order No. Date: By: Pump Data Fig. No. Size Curve No. GPM Head Sp. Gr. Temp. Rotation Packing/Seal Motor Data MFGR Hp RPM Phase-Cycle Voltage Frame Enclosure Insulation Furnished by Mounted 7 9/15

All Sizes - Figs. 4501, 4511 & 4521 Duplex Units www.cranepumps.com FRAME 56C 143TC 145TC 182TC 184TC 213TC 215TC 254TC 256TC 284TC 286TC 324TC D 24⅜ 23 24 26⅜ 27⅜ 28 1 16 29 9 16 31 13 16 33 9 16 37 5 16 38 3 16 39⅞ FRAME 326TC 364TSC 365TSC 404TSC D 41⅜ 41⅞ 42⅞ 44⅜ FIG. SIZE MAX. SOLIDS 4501-1 ⅜ Solids 4501-1½ 11 16 Solids 4501-2½ 1 1 16 Solids 4511-1¼S 5 16 Solids 4511-1½S 7 16 Solids 4511-1½M 7 16 Solids 4511-2S 11 16 Solids 4511-2M 11 16 Solids 4511-3S 1 3 16 Solids 4511-3MD 1 3 16 Solids 4511-4S 15 16 Solids 4521-1½L 7 16 Solids 4521-4MD 1 3 16 Solids 4521-5MD 1⅛ Solids 4521-5MSD 1 9 16 Solids 4521-6MD & 6MLD 1⅜ Solids 6MD 1 9 16 Solids 6MLD TYPE NO A B C E F G K L P Q R S T W X Y Z U 3 1½ 44 2 FT. TO 20 FT. IN 6 IN. MULTIPLES 48 46 3 7⅛ 7⅛ ½ 5 8½ 13 14½ 10 7½ 23 3⅜ 3 2 44 48 46 3 6⅞ 8¾ ½ 5 8½ 13 14½ 10 7 23 3⅛ 3 2½ 44 48 46 3 6⅞ 9⅜ ½ 5 8½ 13 14½ 10 6¾ 23 3¾ 3 2½ 48 54 51 3 5⅛ 10⅜ ½ 2½ 13 16 14½ 12 9¼ 25½ 3¾ 3 3 48 54 51 3 5⅛ 11¼ ½ 2½ 13 16 14½ 12 9 25½ 3⅞ 3 4 48 54 51 3 5⅛ 13¼ ½ 2½ 13 16 14½ 12 8½ 25½ 4¼ 3 1½ 48 54 51 3 5⅜ 8⅞ ½ 2½ 13 16 14½ 12 9⅝ 25½ 3⅜ 3 2 48 54 51 3 5⅜ 9⅜ ½ 2½ 13 16 14½ 12 9½ 25½ 3⅛ 3 2 48 54 51 3 5¼ 9⅜ ½ 2½ 13 16 14½ 12 9½ 25½ 3⅛ 3 2½ 48 54 51 3 5¼ 10 ½ 2½ 13 16 14½ 12 9¼ 25½ 3¾ 3 1½ 48 54 51 3 6⅜ 10⅜ ½ 2½ 13 16 14½ 12 9⅛ 25½ 3⅜ 3 2 48 54 51 3 6⅜ 10½ ½ 2½ 13 16 14½ 12 9⅛ 25½ 3⅛ 3 2½ 48 54 51 3 6⅜ 11¼ ½ 2½ 13 16 14½ 12 9 25½ 3¾ 3 3 48 54 51 3 6⅜ 12½ ½ 2½ 13 16 14½ 12 9⅝ 25½ 4½ 3 2 48 54 51 3 5 10 ½ 2½ 13 16 14½ 12 9¼ 25½ 3¼ 3 2½ 48 54 51 3 5 10¾ ½ 2½ 13 16 14½ 12 9⅛ 25½ 3¾ 3 3 48 54 51 3 5 11⅛ ½ 2½ 13 16 14½ 12 9 25½ 3⅞ 3 2 48 54 51 3 6⅜ 11¼ ½ 2½ 13 16 14½ 12 9 25½ 3¼ 3 2½ 48 54 51 3 6⅜ 11⅞ ½ 2½ 13 16 14½ 12 8¾ 25½ 3¾ 3 3 48 54 51 3 6⅜ 12¼ ½ 2½ 13 16 14½ 12 8¾ 25½ 3⅞ 3 4 48 54 51 3 6⅜ 14¼ ½ 2½ 13 16 14½ 12 8½ 25½ 4⅜ 3 3 48 54 51 3 4⅜ 12¼ ½ 2½ 13 16 14½ 12 8¾ 25½ 5 3 4 48 54 51 3 4⅜ 12¼ ½ 2½ 13 16 14½ 12 8¾ 25½ 4⅜ 3 3 54 60 57 3 5⅛ 13½ ½ 3 16 19 15 15 10¼ 28½ 5 3 4 54 60 57 3 5⅛ 13½ ½ 3 16 19 15 15 10¼ 28½ 4⅜ 3 4 54 60 57 3 3⅝ 13⅜ ½ 3 16 19 15 15 10⅛ 28½ 5¼ 3 5 54 60 57 3 3⅝ 13⅜ ½ 3 16 19 15 15 10⅛ 28½ 5⅛ 3 6 54 60 57 3 3⅝ 13⅝ ½ 3 16 19 15 15 10⅛ 28½ 5⅜ 3 1½ 48 54 51 4 8⅛ 11¾ ½ 2½ 13 16 14½ 12 8 13 16 25½ 3⅜ 3 2 48 54 51 4 8⅛ 12 ½ 2½ 13 16 14½ 12 8¾ 25½ 3⅛ 3 2½ 48 54 51 4 8⅛ 12⅝ ½ 2½ 13 16 14½ 12 8⅝ 25½ 3¾ 3 3 48 54 51 4 8⅛ 13⅞ ½ 2½ 13 16 14½ 12 8¼ 25½ 4½ 3 4 54 60 57 4 4½ 15⅝ ½ 3 16 19 15 15 9⅜ 28½ 5¼ 3 5 54 60 57 4 4½ 15⅝ ½ 3 16 19 15 15 9⅜ 28½ 5⅛ 3 5 60 66 63 4 4⅜ 15¾ ½ 2 18 21½ 15 15 10 31½ 5¼ 3 6 60 66 63 4 4⅜ 15¾ ½ 2 18 21½ 15 15 10 31½ 5⅜ 3 5 60 66 63 4 4⅜ 15¾ ½ 2 18 21½ 15 15 10 31½ 5¼ 3 6 60 66 63 4 4⅜ 15¾ ½ 2 18 21½ 15 15 10 31½ 5⅜ 3 6 60 66 63 4 4¼ 16¼ ½ 2 18 21½ 15 15 9⅞ 31½ 5⅜ 3 8 60 66 63 4 4¼ 17 ½ 2 18 21½ 15 15 9⅝ 31½ 6 1¼ 1½ 1" through 2½" discharge pipe furnished with pip coupling, 3" and larger are furnished with a 125# companion fl ange. Customer Shop Order No. Date: By: Pump Data Fig. No. Size Curve No. GPM Head Sp. Gr. Temp. Rotation Packing/Seal Motor Data MFGR Hp RPM Phase-Cycle Voltage Frame Enclosure Insulation Furnished by Mounted 8 9/15

www.cranepumps.com All Sizes - Figs. 4560 Simplex Units FRAME 184 213 215 254 256 284 286 324 326 364 365 404 405 444 445 TYPE TC TC TC TC TC TC TC TSC TSC TSC TSC TSC TSC TSC TSC D 13¼ 13½ 15¾ 18½ 20½ 20 21¾ 23¼ 25 25¼ 24¾ 28 29¾ 32¾ 35 LP 13 5 16 17 1 16 17 13 16 SIZE FIG. NO. 4 x 4 x 12 4565 6 x 4 x 12 4565 6 x 6 x 12 4565 8 x 6 x 12 4565 4 x 4 x 12 4566 6 x 4 x 12 4566 6 x 6 x 12 4566 8 x 6 x 12 4566 8 x 8 x 12 4566 6 x 6 x 12 4568 8 x 6 x 12 4568 8 x 8 x 12 4568 10x10x12 4568 A B C E F G H J K L M P U Y Z 4 19⅝ 5¼ 36 40 38 4 9 4 16¼ 6 ½ 1½ 19 6 21 6¾ 2 FT. TO 20 FT. IN 6 IN. MULTIPLES 4 36 40 38 4 19⅝ 8⅝ 2⅝ 16¼ 6 ½ 1½ 19 5¼ 6 21 6¾ 6 36 40 38 4 9½ 21 16⅜ 1⅞ 6 ½ 1½ 19 6⅜ 8 23 17⅛ 7 6 21¾ 17⅛ 6⅜ 36 40 38 4 10 1½ 6½ ½ 1½ 19 8 23⅝ 17¾ 7 4 19⅝ 36 40 38 6 9 6 16¼ 6 ½ 1 13 16 19 5¼ 6 21 6¾ 4 36 40 38 6 8⅝ 19⅝ 5⅝ 16¼ 6 ½ 1 13 16 19 5¼ 6 21 6¾ 6 21 16⅜ 36 40 38 6 9½ 4⅞ 6 ½ 1 13 16 19 8¼ 8 23 17⅛ 6¾ 3 FT. TO 20 FT. IN 6 IN. MULTIPLES 6 21¾ 17⅛ 36 40 38 6 10 3⅜ 6½ ½ 1 13 16 19 8¼ 8 23⅝ 17¾ 6½ 8 26⅜ 20½ 48 54 51 6 12⅜ 2¼ 8 ½ 1 13 16 25½ 7½ 10 29 21¾ 2⅝ 6 48 54 51 8 9½ 21 16⅜ 8⅞ 6 ½ 1 13 16 25½ 12 8 23 17⅛ 10¼ 6 21¾ 17⅛ 48 54 51 8 10 7⅜ 6½ ½ 1 13 16 25½ 12 8 23⅝ 17¾ 10¼ 8 26⅜ 20½ 48 54 51 8 12⅜ 6¼ 8 ½ 1 13 16 25½ 11½ 10 29 21¾ 6⅝ 10 48 54 51 8 12½ 29 4 21¾ 8 ½ 1 13 16 25½ 6½ 1" through 2½" discharge pipe furnished with pip coupling, 3" and larger are furnished with a 125# companion fl ange. Customer Shop Order No. Date: By: Pump Data Fig. No. Size Curve No. GPM Head Sp. Gr. Temp. Rotation Packing/Seal Motor Data MFGR Hp RPM Phase-Cycle Voltage Frame Enclosure Insulation Furnished by Mounted 9 9/15

All Sizes - Fig. 4560 Duplex Units www.cranepumps.com FRAME 184 213 215 254 256 284 286 324 326 364 365 404 405 444 445 TYPE TC TC TC TC TC TC TC TSC TSC TSC TSC TSC TSC TSC TSC D 13¼ 13½ 15¾ 18½ 20½ 20 21¾ 23¼ 25 25¼ 24¾ 28 29¾ 32¾ 35 LP 13 5 16 17 1 16 17 13 16 SIZE FIG. NO. 4 x 4 x 12 4565 6 x 4 x 12 4565 6 x 6 x 12 4565 8 x 6 x 12 4565 4 x 4 x 12 4566 6 x 4 x 12 4566 6 x 6 x 12 4566 8 x 6 x 12 4566 8 x 8 x 12 4566 6 x 6 x 12 4568 8 x 6 x 12 4568 8 x 8 x 12 4568 10x10x 12 4568 A B C E F G K L P P Q R S T U W X Y Z 4 60 66 63 4 4¼ 16¼ ⅞ ½ 2 18 21¼ 15 1½ 15 9⅞ 31½ 5¼ 6 6¾ 2 FT. TO 20 FT. IN 6 IN. MULTIPLES 4 60 66 63 4 3 16¼ ⅞ ½ 2 18 21½ 15 1½ 15 5¼ 9⅞ 31½ 6 6¾ 6 16⅜ 9¾ 6⅜ 60 66 63 4 2¼ ⅞ ½ 2 18 21½ 15 1½ 15 31½ 8 17⅛ 9⅝ 7 6 17⅛ 9⅝ 6⅜ 60 66 63 4 1⅞ ⅞ ½ 2 18 21½ 15 1½ 15 31½ 8 17¾ 9⅜ 7 4 60 66 63 6 6¼ 16¼ ⅞ ½ 2 18 21½ 15 1 13 16 15 9⅞ 31½ 5¼ 6 6¾ 4 60 66 63 6 6 16¼ ⅞ ½ 2 18 21½ 15 1 13 16 15 9⅞ 31½ 5¼ 6 6¾ 6 16⅜ 60 66 63 6 5¼ ⅞ ½ 2 18 21½ 15 1 13 16 15 9¾ 31½ 8¼ 8 17⅛ 9⅝ 6¾ 3 FT. TO 20 FT. IN 6 IN. MULTIPLES 6 17⅛ 60 66 63 6 3¾ ⅞ ½ 2 18 21½ 15 1 13 16 15 9⅝ 31½ 8¼ 8 17¾ 9⅜ 6½ 8 20½ 78 84 81 6 2⅞ 1⅛ ⅝ -- 26 29 15 1 13 16 22 14⅞ 40½ 7½ 10 21¾ 14⅜ 2⅝ 6 16⅜ 78 84 81 8 5¼ ⅞ ⅝ -- 26 29 15 1 13 16 22 14⅞ 40½ 12 8 17⅛ 14⅜ 10¼ 6 17⅛ 78 84 81 8 7¾ 1⅛ ⅝ -- 26 29 15 1 13 16 22 14⅞ 40½ 12 8 17¾ 14⅜ 10¼ 8 20½ 78 84 81 8 6⅞ 1⅛ ⅝ -- 26 29 15 1 13 16 22 14⅞ 40½ 11½ 10 21¾ 14⅜ 6⅝ 10 78 84 81 8 4⅝ 21¾ 1⅛ ⅝ -- 26 29 15 1 13 16 22 14⅜ 40½ 6½ 1" through 2½" discharge pipe furnished with pip coupling, 3" and larger are furnished with a 125# companion fl ange. Customer Shop Order No. Date: By: Pump Data Fig. No. Size Curve No. GPM Head Sp. Gr. Temp. Rotation Packing/Seal Motor Data MFGR Hp RPM Phase-Cycle Voltage Frame Enclosure Insulation Furnished by Mounted 10 9/15

www.cranepumps.com Fig. 4500 Selection Curves, 3500RPM & 1750RPM 11 12/08

Fig. 4500 Selection Curves, 1150RPM & 870RPM www.cranepumps.com 12 12/08

www.cranepumps.com Fig. 4511 Sizes: 1¼S & 1½S, 1150RPM 13

Fig. 4511 Sizes: 1½M & 2S, 1150RPM www.cranepumps.com 14

www.cranepumps.com Fig. 4511 Sizes: 2M & 3S, 1150RPM 15

Fig. 4511 & 4521 Sizes: 3MD & 1½L, 1150RPM www.cranepumps.com 16

www.cranepumps.com Fig. 4521 Sizes: 4MD & 5MD, 1150RPM 17

Fig. 4521 Sizes: 5 MSD & 6MD, 1150RPM www.cranepumps.com 18

www.cranepumps.com Fig. 4521 Sizes: 6MLD, 1150RPM 19

Fig. 4565, 4566 & 4568 Sizes: 4 x 4 x 12 DV & 6 x 4 x 12 DV, 1150RPM www.cranepumps.com 20

www.cranepumps.com Fig. 4565, 4566 & 4568 Sizes: 6 x 6 x 12 DV & 8 x 6 x 12 DV, 1150RPM 21

Fig. 4565, 4566 & 4568 Sizes: 8 x 8 x 12 DV & 10 x 10 x 12 DV, 1150RPM www.cranepumps.com 22

www.cranepumps.com Fig. 4565, 4566 & 4568 Size: 10 x 10 x 12 DV, 870RPM 23

Fig. 4501 Sizes: 1" & 1½", 1750RPM www.cranepumps.com 24

www.cranepumps.com Fig. 4501 & 4511 Sizes: 2½" & 1¼S, 1750RPM 25

Fig. 4511 Sizes: 1½S & 1½M, 1750RPM www.cranepumps.com 26

www.cranepumps.com Fig. 4511 Sizes: 2S & 2M, 1750RPM 27

Fig. 4511 Sizes: 3S & 3MD, 1750RPM www.cranepumps.com 28

www.cranepumps.com Fig. 4521 Sizes: 4 MD & 5 MD, 1750RPM 29

Fig. 4511 & 4521 Sizes: 4 S & 5 MS, 1750RPM www.cranepumps.com 30

www.cranepumps.com Fig. 4521 Sizes: 5MSD & 6 MD, 1750RPM 31

Fig. 4521 Sizes: 6 MLD & 1½L, 1750RPM www.cranepumps.com 32

www.cranepumps.com Fig. 4565, 4566 & 4568 Sizes: 4 x 4 x 12 DV & 6 x 4 x 12 DV, 1750RPM 33

Fig. 4565, 4566 & 4568 Sizes: 6 x 6 x 12 DV & 8 x 6 x 12 DV, 1750RPM www.cranepumps.com 34

www.cranepumps.com Fig. 4565, 4566 & 4568 Sizes: 8 x 8 x 12 DV, 1750RPM 35

Fig. 4511H Sizes: 1" & 1½", 3500RPM www.cranepumps.com 36

www.cranepumps.com Fig. 4511H Sizes: 1¼ S & 1½ S, 3500RPM 37

Fig. 4511H Sizes: 2 S & 3 MD, 3500RPM www.cranepumps.com 38