Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Similar documents
CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

A302DN.40/.63A Thermal Current Motor Starter

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Cutler-Hammer. January 2001

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

N0N A 250V One-Time Class H Fuse

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Switchboards Instant Service

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Cutler-Hammer. January 2001

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Engine Generator Circuit Breakers

SW Tog DP 30A 120/277V Autogrd B&S WH

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

ICN2S40N35I Ele Ballast (2) F40T V

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

2.2. Molded Case Circuit Breakers. Contents. Motor Circuit Protectors (MCP)

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

TA Ta VA CTRL-XFRMR

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

Product Line Overview. The Most Logically Designed Contact Assembly

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

4 Square Partition Square Cut Tile Wall 2 Gang Cover 2 1/8 Deep 1/2 to 1 RSD

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Enclosures. See Section Typical Description

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

RELB2S40N35I (2)F40T12 120V Ele BLST

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:

5-1/2 INCH L X 4-1/8 INCH W X 6 INCH H

3. Coils shall be of molded construction

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Low-Peak 600V Class RK1

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

2.3. Molded Case Circuit Breakers. Contents

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight.

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Diva Dimmer - Gloss Finish, Fluorescent or LED Dimming with

Bussmann series Quik-Spec Power Module Switch elevator disconnect

C E R T I F I C A T E O F C O M P L I A N C E

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

EPOXY POWDER COATED COPPER FREE ALUMINUM

24HR 30A SPST TM SW. Features. Long Description

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

FDBT S 32W120V DM Bal

Bulletin 190-M Compact Starters. Selection Guide

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

XT IEC Power Control Manual Motor Protectors

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

2.1. NEMA Contactors and Starters

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

1P 120/240V, 3600 RPM,

G4047BM 2G Gry Cover Plate

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

Recp Duplex 20A 250V 2P3W STR Swire WH

Transcription:

3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit Protector, Magnetic, Molded Case; F Frame; 600 Vac, 50 VDC; 100 Ampere; 3 Pole; Trip 300 to 1000 Ampere; Starter Size Nema 3; Motor Fla 3 to 84.5 Ampere; Terminal Non Aluminum Line Terminal, Load Terminal; Approval Ul, Ce Weight per unit 4.5 (lbs/each) Product Category 3 Pole Motor Circuit Protector Features Current Rating 100 AMPERE Frame Type F Maximum AC Voltage Rating 600 Maximum DC Voltage Rating 50 Motor FLA 3 TO 84.5 AMPERE Poles 3 Starter Size NEMA 3 Terminal Type NON ALUMINUM LINE TERMINAL, LOAD TERMINAL Trip 300 TO 1000 AMPERE Voltage Rating 600 VAC, 50 VDC Descriptions Additional Information APPLICABLE STANDARD IEC 157-1 Commodity Description Circuit Breakers - Commercial Circuit Breakers Description 3P 100A 600V F-FRAME MC PROTECTOR Long Description MOTOR CIRCUIT PROTECTOR, MAGNETIC, MOLDED CASE; F FRAME; 600 VAC, 50 VDC; 100 AMPERE; 3 POLE; TRIP SETTING 300 TO 1000 AMPERE; STARTER SIZE NEMA 3; MOTOR FLA 3 TO 84.5 AMPERE; TERMINAL NON ALUMINUM LINE TERMINAL, LOAD TERMINAL; APPROVAL UL, CE Product Type Motor Circuit Protector Circuit Breaker

3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Manufacturer Information Brand EATON CUTLER-HAMMER GTIN 00786679150856 Manufacturers Part Number H100R3C Model H UPC 786679150856 Taxonomies, Classifications, and Categories Category Description BREAKERS Type MAGNETIC, MOLDED CASE Packaging Carton 1 Weight Per each 4.45 Uses, Certifications, and Standards Approval UL 489, CSA C., CE

Molded Case Circuit Breakers.3 Motor Circuit Protectors Contents Description Product Overview.......................... Standards and Certifications.................. Quick Reference........................... G-Frame (15 100 Amperes)................... F-Frame (10 5 Amperes)................... J-Frame (70 50 Amperes)................... K-Frame (70 400 Amperes)................... L-Frame (15 600 Amperes).................. M-Frame (300 800 Amperes)................. N-Frame (400 100 Amperes)................. R-Frame (800 500 Amperes)................. Motor Circuit Protectors () Catalog Number Selection................. Product Selection........................ Accessories............................ Motor Protection Circuit Breakers (MPCB)....... Type ELC Current Limiter Attachment (Size 0 4)..... Current Limiting Circuit Breaker Module........... Internal Accessories......................... External Accessories........................ Page V4-T-11 V4-T-1 V4-T-13 V4-T-16 V4-T-140 V4-T-157 V4-T-165 V4-T-19 V4-T-18 V4-T-9 V4-T-44 V4-T-64 V4-T-65 V4-T-66 V4-T-74 V4-T-76 V4-T-77 V4-T-81 V4-T-31 Motor Circuit Protectors () Product Description Designated as Eaton s Types G and H, the instantaneous-only motor circuit protector () is available in ratings from 3A to 100A for motor starter sizes 0 through 8. An innovative design of internal components allows higher -starter combination interrupting ratings. The is marked to permit proper electrical application within the assigned equipment ratings. Standards and Certifications The is designed to comply with the applicable requirements of Underwriters Laboratories Standard UL 489, Canadian Standards Association Standard C. No. 5.1, and International Electrotechnical Commission Recommendations IEC 157-1. The is a recognized component (UL File E7819) and complies with the applicable requirements of Underwriters Laboratories Standard UL 489. It is also designed to comply with the applicable requirements of Canadian Standards Association Standard C. No. 5.1, International Electrotechnical Commission Recommendations IEC 157-1, and nameplates bear the CE marking. Note: Interrupting ratings are dependent on starter it is used with. Volume 4 Circuit Protection CA08100005E January 013 www.eaton.com V4-T-63

.3 Molded Case Circuit Breakers Catalog Number Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units. Motor Circuit Protector Motor Circuit Protector Note Motor Circuit Protective Type H = 3 poles HMP = poles 1 HS = 3 poles 1 On J- and K-Frame Hs only. Motor Circuit Protective Device G = 3 poles Continuous Ampere Rating 003 007 015 05 030 050 070 100 150 50 400 600 800 100 Continuous Ampere Rating 003 007 015 030 050 060 063 H 003 A0 C Magnetic Trip Range/ NEMA Starter Size A0 = 9 30/0 C0 = 1 70/0 E0 = 45 150/0 D0 = 40 60/0 H1 = 90 300/1 G = 80 10/ K = 50 500/ J = 115 170/ M = 10 700/ L3 = 160 40/3 R3 = 300 1000/3 T4 = 450 1500/4 U4 = 750 500/4 A5 = 350 700/5 C5 = 450 900/5 D5 = 500 1000/5 F5 = 65 150/5 G5 = 750 1500/5 J5 = 875 1750/5 K5 = 1000 000/5 L5 = 115 50/5 W5 = 150 500/5 N5 = 1500 3000/5 R5 = 1750 3500/5 X5 = 000 4000/5 Y5 = 50 4500/5 L6 = 1800 6000/6 (electronic) X6 = 500 500/6 (electronic) Y6 = 1000 4000/6 (electronic) X7 = 1600 6400/7 (electronic) Y8 = 400 9600/8 (electronic) G 003 A0 C Magnetic Trip Range/NEMA Starter Size A0 = 15 30/0 C0 = 35 70/0 E0 = 75 150/0 H1 = 150 300/1 K = 50 500/ J = 300 600/ M = 30 630/ Suffix C = Non-aluminum terminals W = Without terminals X = Load terminals only Y = Line terminals only S = Stainless steel terminals (150A frame only) No Suffix: Standard terminals on line and load Suffix C = Non-aluminum terminals V4-T-64 Volume 4 Circuit Protection CA08100005E January 013 www.eaton.com

Molded Case Circuit Breakers.3 F-Frame 600 Vac Maximum, 50 Vdc Maximum 600 Vac Maximum, 50 Vdc Maximum, continued NEMA Starter Size Cont. Amps Cam Motor Full Load Current Amperes (FLA) 1 Trip Catalog Number 0 3 A 0.69 0.91 9 H003A0C B 0.9 1.0 1 C 1.1 1. 15 D 1.3 1.5 18 E 1.6 1.7 1 F 1.8 1.9 4 G.0. 7 H.3.5 30 0 7 A 1.5.0 1 H007C0C B.1.5 8 C.6 3.1 35 D 3. 3.6 4 E 3.7 3.9 49 F 4.3 4.7 56 G 4.8 5. 63 H 5.3 5.7 70 0 15 A 3.4 4.5 45 H015E0C B 4.6 5.6 60 C 5.7 6.8 75 D 6.9 7.9 90 E 8.0 9.1 105 F 9. 10.3 10 G 10.4 11.4 135 H 11.5 1.6 150 1 30 A 6.9 9.1 90 H030H1C B 9. 11.4 10 C 11.5 13.7 150 D 13.8 16.0 180 E 16.1 18.3 10 F 18.4 0.6 40 G 0.7.9 70 H 3.0 5. 300 50 A 11.5 15. 150 H050KC B 15.3 19.1 00 C 19..9 50 D 3.0 6.8 300 E 6.9 30.6 350 F 30.7 4.5 400 G 34.6 38.3 450 H 38.4 4.1 500 NEMA Starter Size Cont. Amps Cam Motor Full Load Current Amperes (FLA) 1 Trip Catalog Number 70 A 16.1 1.4 10 H070MC B 1.5 6.8 80 C 6.9 3. 350 D 3.3 37.5 40 E 37.6 4.9 490 F 43.0 48.3 560 G 48.4 53.7 630 H 53.8 59.1 700 3 100 A 3.0 30.6 300 H100R3C B 30.7 38.3 400 C 38.4 46.0 500 D 46.1 53.7 600 E 53.8 61.4 700 F 61.5 69.1 800 G 69. 76.8 900 H 76.9 84.5 1000 4 150 A 34.6 46.0 450 H150T4C B 46.1 57.5 600 C 57.6 69.1 750 D 69. 80.6 900 D 69. 80.6 900 E 80.7 9. 1050 F 9.3 103.7 100 G 103.8 115. 1350 H 115.3 16.7 1500 4 150 A 57.0 75.0 750 H150U4C B 76.0 95.0 1000 C 96.0 114.0 150 D 115.0 130.7 1500 E 3 1750 F 3 000 G 3 50 H 3 500 Notes 1 Motor FLA ranges are typical. The corresponding trip setting is at 13 x the minimum FLA value shown. Where a 13 x setting is required for an intermediate FLA value, alternate Cam settings and/or ratings should be used. For DC applications, actual trip levels are approximately 40% higher than values shown. 3 s above 130 amperes are for special applications. NEC Article 430.110(a) requires the ampere rating of the disconnecting means to be not less than 115% of the motor full load ampere rating. H 3 100A come with line and load steel body terminals, 3T100FB. H 150A come with line and load steel body terminals, 3T150FB. Volume 4 Circuit Protection CA08100005E January 013 www.eaton.com V4-T-67