PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

Similar documents
STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

DIESEL GENERATOR SET FEATURES

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

Specifications. 3406C Generator Set Electric Power

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Voltage 220 to or 1800 RPM

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

Specifications. C13 Generator Set Electric Power

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

3412C Generator Set Electric Power. Specifications. Benefits and Features

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

DIESEL FEATURES GENERATOR SET

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Transcription:

DIESEL GENERATOR SET PRIME 365 ekw 456 kva Image shown may not reflect actual package. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES COMPLETE, READY-TO-RUN SYSTEM Full-featured system includes, integral fuel tank base, exhaust silencer and flex, charging alternator, batteries, rack and cables, and main line circuit breaker Fully operable upon delivery, just add fuel and power cables ENCLOSURES (optional) Weather protective and sound attenuated SINGLE-SOURCE SUPPLIER Complete systems designed and built at Caterpillar ISO certified facilities. Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Worldwide parts availability through the Caterpillar dealer network With over 1844 dealer branch stores operating in 166 countries, you re never far from the Caterpillar part you need 99.7% of parts orders filled within 24 hours. The best product support record in the industry Caterpillar dealer service technicians are trained to service every aspect of your electric power generation system Preventive maintenance agreements The Cat Scheduled Oil Sampling (S O S SM ) program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion byproducts CAT 3406C TA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight UL 2200 Listed packages are available. Certain restrictions may apply. Consult with you Caterpillar dealer CAT SR4B GENERATOR Designed to match performance and output characteristics of Caterpillar diesel engines Optimum winding pitch for minimum total harmonic distortion and maximum efficiency Segregated low voltage, AC/DC accessory box provides single point access to accessory connections UL 1446 Recognized Class H insulation system CAT CONTROL PANELS Four levels of controls, designed to meet individual customer needs: - Electromechanical panel provides analog monitoring and metering with basic protection - EMCP II provides digital monitoring, metering, and protection - EMCP II+ provides EMCP II features along with full-featured power metering and protective relaying - Switchgear conversion provides easy interface for remote switchgear UL 508A Listed WHERE THE WORLD TURNS FOR POWER

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner Service indicator Dual element air cleaner Heavy-duty air cleaner Air inlet shutoff Cooling Exhaust Fuel Generator Radiator with guard Coolant drain line with valve Fan and belt guards Caterpillar Extended Life Coolant Stainless steel exhaust flex and ANSI outlet flange 10 dba muffler Primary and secondary fuel filters Fuel priming pump Flexible fuel lines Fuel pressure gauge Self excited Class H insulation Class F temperature rise (105 C prime/130 C standby) VR3 Voltage Regulator, 3-phase sensing Circuit breaker, IEC compliant, 3-pole with shunt trip Radiator duct flange Jacket water heater with shutoff valves Low coolant level alarm or shutdown Heat exchanger and expansion tank 25 dba muffler 35 dba muffler Elbow kit and through-wall installation kit Manifold and turbocharger guards Water separator Manual transfer pump (3) Automatic transfer systems to choose from Low fuel level alarm Permanet magnet excited 2:1 Volts/Hz AVR Digital Voltage Regulator Digital Voltage Regulator with KVAR/PF control Anti-condensation space heater Reactive droop Oversize and premium generators (except 365 ekw Prime/400 ekw Standby) Circuit breaker, IEC Compliant, 4-pole with shunt trip Governor Hydra-mechanical Woodward 1724 Electronic isochronous Electronic load sharing Governor control motor Control Panels EMCP II Electromechanical auto start/stop panel EMCP II+ Switchgear conversion Customer Communication Module Local alarm and remote annunciator modules Lube Lubricating oil and filter Manual sump pump Oil drain line with valves Fumes disposal Mounting Starting/Charging General Formed steel base with integral fuel tank, 8 hour capacity minimum Linear vibration isolators between base and enginegenerator 45 amp charging alternator Energized to Run (ETR) fuel shutoff solenoid 24 volt starting motor Batteries with rack and cables Wide base with integral fuel tank Extended capacity fuel tank base Skid base 5 amp battery charger Oversize batteries Ether starting aid Battery disconnect switch Enclosures - sound attenuated, weather protective Automatic transfer switches (ATS) EU Certificate of Conformance (CE) 2

SPECIFICATIONS CAT SR4B GENERATOR Frame Size........................................450 Excitation..................................Self Excited Pitch..........................................0.7500 Number of poles.....................................4 Number of bearings.......................single Bearing Insulation.UL 1446 Recognized Class H with tropicalization and antiabrasion IP Rating................................Drip Proof IP22 Alignment...................................Pilot Shaft Overspeed capability - % of rated......................125 Wave form........................less than 5% deviation Paralleling kit/droop transformer..................optional Voltage regulator.............3 Phase sensing with volts/hz Voltage regulation...........less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) Telephone Influence Factor...................Less than 50 Harmonic distortion.........................less than 5% CAT DIESEL ENGINE 3406C T, I-6, 4-Stroke-Cycle Watercooled Diesel Bore - mm......................................137.20 Stroke - mm....................................165.10 Displacement - L..................................14.64 Compression ratio.............................14.5 TO 1 Aspiration.........................................TA Fuel System....................Mechanical pump and line Governor type.........................hydra-mechanical CAT CONTROL PANELS EMCP II 24 Volt DC Control NEMA 1, IP22 enclosure Electronically dead front Lockable hinged door Generator instruments meet ANSI C-39-1 Terminal box mounted Single location customer connection point EU compliant - segregated AC/DC connections Panel illuminating lights Auto start/stop control Voltage adjust potentiometer True RMS AC metering Digital indications for: - rpm - Operating hours - Oil pressure - Coolant temperature - System DC volts - AC volts, phase amps, Hz Shutdowns with indicating lights for: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) 3

TECHNICAL DATA Open Generator Set - 1800 rpm/60 Hz/480 Volts PRIME DM2274 Package Performance Power rating 365 ekw Power rating @ 0.8 pf 456.25 kva Fuel Consumption 100% load with fan 98.4 L/hr 26.0 Gal/hr 75% load with fan 72.5 L/hr 19.2 Gal/hr 50% load with fan 50.6 L/hr 13.4 Gal/hr Cooling System * Air flow restriction (system).12 kpa 0.48 in. water Engine coolant capacity 20.8 L 5.5 Gal Radiator coolant capacity 40.0 L 10.6 Gal Engine coolant capacity with radiator 60.8 L 16.1 Gal Exhaust System Combustion air inlet flow rate 30.2 m3/min 1,066.5 cfm Exhaust stack gas temperature 540.1 Deg C 1,004 Deg F Exhaust gas flow rate 86.9 m3/min 3,068.8 cfm Exhaust flange size (internal diameter) 152.4 mm 6.0 in Exhaust system backpressure (maximum allowable) 6.7 kpa 26.9 in. water Heat rejection Heat rejection to coolant (total) 225 kw 12,796 Btu/min Heat rejection to exhaust (total) 346 kw 19,677 Btu/min Heat rejection to atmosphere from engine 81 kw 4,606 Btu/min Heat rejection to atmosphere from generator 22.2 kw 1,262.5 Btu/min Alternator ** Motor starting capability @ 30% voltage dip 931 skva Frame 450 Temperature Rise 105 Deg C Lube System Lube oil refill volume with filter change for 38.0 L 10.0 Gal standard sump * Ambient capability at 200 m (660 ft) above sea level. For ambient capability at other altitudes consult your Caterpillar dealer. ** Generator temperature rise is based on a 40 degree C ambient per NEMA MG1-32. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: ABGSM TM3, AS1359, AS2789, BS4999, BS5000, BS5514, DIN6271, DIN6280, EGSA101P, IEC34/1, ISO3046/1, ISO8528, JEM1359, NEMA MG 1-22, VDE0530, 89/392/EEC, 89/336/EEC Prime - Output available with varying load for an unlimited time. Prime power in accordance with ISO8528. 10% overload power in accordance with ISO3046/1, AS2789, DIN6271, and BS5514 available on request. Prime power ambients shown indicate ambient at 100 percent load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1995 standard conditions. These ratings also apply at ISO3046/1, DIN6271, and BS5514 standard conditions. Fuel Rates are based on fuel oil of 35º API (16º C or 60º F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional Ratings may be available for specific customer requirements. Consult your Caterpillar representative for details. 5

Package Dimensions Length 3800.0 mm 149.61 in Width 1105.0 mm 43.5 in Height 2091.2 mm 82.33 in Weight 4181 kg 9,218 lb Note: Do not use for installation design. See general dimension drawings for detail (Drawing #1440255). TMI Reference No.: DM2274 PL Reference No.: 406DE72 European Sourced LEHE2332 19 February 2002 28469 www.cat-electricpower.com 2002 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication.