Short Manual. PIKO Inverter

Similar documents
Short Manual. PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

Short Manual. PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

Powerstocc Excellent. Short Manual. PS DC Storage.

Data sheet PIKO 12-20

Data sheet. PIKO MP plus

Data sheet. PLENTICORE plus. plus

Data sheet PIKO IQ

Data sheet PIKO 36 EPC EPC

Pre-announcement. Transformerless Solar Inverters

SolarMax P series The power package for residential solar plants

SolarMax MT series The all-rounder for trade and industry

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Technical specifications

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

Sunny Tripower. Can do everything that we can

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

photovoltaikforum.com

SolarMax MT series. The power pack for maximum yields.

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

SIZING OF SOLAR GENERATOR

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

/ Optimised energy management. / Dynamic Peak Manager. / Smart Grid Ready 12.0 A / 12.0 A 18.0 A / 18.0 A

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Catch Eco Range : Technical Specification Sheet

Get ready for rising energy challenges. This is where xstorage Home can help

INVEOR "Smart connections." on five levels

PowerRouter Solar Battery Self-use

500 / 630 / 720 / 760 / 800 / 850 / 900

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Price list - Inverter

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

Sunny Tripower CORE1.

PV inverter SUNNY MINI CENTRAL 7000HV

Wind Power Inverter WINDY BOY 3600TL / 5000TL

Installation and Operation manual

Technical Data Sheets

Smart connections. Certificates. PIKO-Inverter

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Operating manual UPS - System

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

Catalogue 2013 SOLPLUS Inverters and Accessories

SolarMax MT A series A reliable solution for commercial PV applications

CONERGY CIS 1200 Manufactured By Bosch

SOLAR4SAVINGS SYSTEMS

Accessories for power generation plants in Italy SMA GRID GATE

Technical specifications

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Power conversion systems for energy storage. Engineering that stores

Technical Documentation

Certificate of Conformity self-generation unit

Residential Energy Storage System SH 5K

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

PV inverter SUNNY BOY 2100TL

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

PV Inverter SUNNY BOY 3300/3800

ABB central inverters PVS to 1000 kw

SolarMax 20C/25C/30C/35C. Proven reliability.

SAJ Solar Inverter. Sununo Plus 1K/1.5K BENEFITS. Smart and Easy to Use. Flexible and Efficient. Safe and Reliable. Convenient Installation

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

3 Phase Power Systems - Designed for Canada

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Total number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1

Development of the Single Phase PV Inverter SANUPS P61A

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

APS-PV-Series 1000 V DC

COUNTIS E22 Three-phase energy meter Direct - 80 A

TANZANIA BUREAU OF STANDARDS

Technical Data Sheets

+86(571) (571) (V4)

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

Wind Power Inverter WINDY BOY 5000A/6000A

SOLAR4SAVINGS SYSTEMS

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

BLU SERIES Battery Load Units

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Guidelines for the Design of Residential and Community Level Storage Systems Combined with Photovoltaics (PV)

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Assembly instructions

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

ABB central inverters PVS to 1000 kw

PIKO BA System smart, communicative and autonomous

Energy Storage System for Home

DEGERtracker 3000HD / 3000NT / 5000NT Long-term power supplier. DEGERtracker - Dual-axis tracking system

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

Transcription:

Short Manual PIKO Inverter 3.0-20

EU Declaration of conformity The company KOSTAL Solar Electric Gmb anferstraße 6 7908 Freiburg i. Br. Germany hereby declares that the inverters described in this document are the essential requirements and other relevant provisions of the below mentioned guidelines in accordance. Directive 204/30/EU (Electromagnetic compatibility, EMC) Directive 204/35/EU (Electrical Apparatus Low Voltage Directive) A detailed EU declaration of conformity can be found at: www.kostal-solar-electric.com/download/zertifikate 2 3

Proper use The PIKO Inverter converts DC current into AC current. The current can be used for the following: nn for consumption nn for feeds into the public mains grid The unit may only be used in grid-connected photovoltaic systems within the permissible power range and under the permissible environmental conditions. The device is not intended for mobile use. Inappropriate use can be hazardous and lead to injury or even death of the user or third parties. Material damage to the device and other equipment can also occur. The inverter may therefore only be used for its intended purpose. Additional User Information For additional information, please read the complete operation manual on the CD. Exclusion of liability Any use that differs from or goes beyond the stated intended purpose is considered inappropriate. The manufacturer accepts no liability for any damage resulting from this. Modifications to the inverter are prohibited. The inverter may only be used if safe to operate and in technically perfect condition. Any instance of misuse will cause the termination of the warranty, guarantee and general liability of the manufacturer. Only a qualified electrician may open the device. The inverter must be installed by an electrician who is responsible for observing the applicable standards and regulations. Work that could affect the electrical power system of the respective utility company at the site of the solar energy feed-in may only be carried out by qualified electricians expressly authorised (licensed) by the utility company. This includes changes to the factory preset parameters. The installer must always observe the regulations of the utility company. The utility company s specifications must always be observed when setting the parameters. User Manual 4 5

Type plate Scope of delivery 2 3 8 0 2 3 4 5 6 20 anferstraße 6 D-7908 Freiburg +49 (0) 76-47744-00 www.kostal-solar-electric.com XXXXXXX Item no.: XXXXXXXX DCinput: VMPP = XXX...XXX V VDC_MAX IDC_MAX IPV_SC = XXX V = XX.X A = XX.X A ACoutput: XX~, XXXV, XXz, max. XX.X A XXXXX VA (cosϕ=0.9...) Protective Class I, IP XX -20 C...60 C, OVC DC:II / AC:III VDE V 026-- Art.-No.: NNNNNNNN Ser.-No.: XXXXXABCXXXXX W: YYXXXX PAR: XX.XX FW: XX.XX UI: XX.XX Serviceupdate: XXXXXXXX XXXXABCXXXXX 4 5 6 7 9 7 8 9 Name and address of manufacturer 2 Device type 3 Item number 4 MPP control range 5 Maximum DC input voltage 6 Maximum DC input current 7 Maximum DC short circuit current 8 Number of feed-in phases, Output voltage (nominal), Output frequency, Maximum AC output current 9 Maximum AC power 0 Protective class to IEC 6203, Protection type and ambient Temperature range, overvoltage category 2 Requirements conforming to those of the built-in grid monitoring 3 Internal item number 4 Serial number 5 Version of hardware 6 Version of firmware 7 Version of parameter set 8 Version of user interface 9 Date of the last update 3.0 3.0 6 20 Removable guarantee label 7 4x L N PE 4.2-20 4.2-20 5x 5x 4.2-20 L L2 L3 N PE 5-20 User Manual Safety Notes

Selecting the installation side NOTE Observe the following instructions, or else warranty claims will be restricted. Maintain safe distance from flammable materials or areas at risk of explosion. Protect from rain and water. 90 Select vertical installation location. Use the included wall bracket. Protect from direct sunlight. 200 00 Required cooling space is 200 mm vertical and 00 mm horizontal. Protect from falling parts. C/ F % Ambient temperature must be between -20 C and +60 C. Air humidity must be between 4 % and 00 % (condensing). N3 Protect from dust, contamination and ammonia. Prevent access by children. Select non-flammable installation location. Ensure easy access and visible display. Select stable installation location. No plasterboard or wooden walls. Ensure that people are not disturbed by operating noise. 8 9

Installation To lift the inverter Cooling space Lift here!. A C B Mounting spaces D Lift here! C A E 2. B To install several inverters A Inverter Type PIKO 5-20 00 (3.9) 200 (7.9) 76 (2.99) 46 (.8) 2 (0.) 0 3. Measures in mm (inch) A B C D E PIKO 3.0, 4.2-8.5 00 (3.9) 200 (7.9) 60 (2.4) 70 (2.8) 2 (0.) PIKO 0-2 00 (3.9) 200 (7.9) 66 (2.6) 35 (.4) 2 (0.)

Connecting AC and DC side LEBENSGEFAR DURC STROMSCLAG! Wechselrichter spannungsfrei schalten. RISK OF DEAT DUE TO ELECTRICAL SOCK! De-energise the inverter. DANGER DE MORT PAR ÉLECTROCUTION! Mettre l onduleur hors tension. PELIGRO DE MUERTE DEBIDO A ELECTROCUCIÓN! Desconectar el inversor de la tensión. PERIGO DE MORTE DEVIDO A COQUE ELÉTRICO! Desligar a tensão de corrente do inversor. PERICOLO DI MORTE PER SCOSSA ELETTRICA! Eliminare la tensione dall inverter. LIVSFARE PGA. ELEKTRISK STØD! Vekselstrømsomformeren skal kobles fra spændingen. LEVENSGEVAAR DOOR ELEKTRISCE SCOK! Schakel de omvormer spanningsvrij. OROŽENÍ ŽIVOTA ELEKTRICKÝM PROUDEM! Odpojte střídač od napětí. PERICOL DE ELECTROCUTARE! Scoateţi ondulorul de sub tensiune. SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA! Razsmernik odklopite iz električne napetosti. NEBEZPEČENSTVO OROZENIA ŽIVOTA ZÁSAOM ELEKTRICKÉO PRÚDU! Menič prepnite do beznapäťovej prevádzky. ELEKTRIK ÇARPMASI NEDENIYLE AYATI TELIKE! İnvertörü gerilimsiz hale getirin. ΚΊΝΔΥΝΟΣ ΘΑΝΆΤΟΥ ΑΠΌ ΗΛΕΚΤΡΟΠΛΗΞΊΑ! Αποσυνδέστε τον αντιστροφέα από το ρεύμα. ОПАСНОСТ ЗА ЖИВОТА ПОРАДИ ТОКОВ УДАР. Изключвайте инвертора от напрежението. LIVSFARA PÅ GRUND AV ELEKTRISK STÖT! Koppla växelriktaren spänningsfri. ZAGROŻENIE ŻYCIA PRZEZ PORAŻENIE PRĄDEM! Odłączyć falownik od zasilania. ELEKTRILÖÖGI OT! Lahutage vaheldi vooluvõrgust. PAVOJUS GYVYBEI DĖL ELEKTROS SROVĖS SMŪGIO! Inverteriui nutraukite įtampos tiekimą. ELEKTRISKĀS STRĀVAS TRIECIENA BRIESMAS! Atslēgt invertoru no strāvas. OPASNOST PO ŽIVOT OD STRUJNOG UDARA! Isključiti izmjenjivač. OPASNOST PO ŽIVOT ZBOG STRUJNOG UDARA! Isključiti izmjenjivač. OPASNOST PO ŽIVOT USLIJED STRUJNOG UDARA! Izmjenjivač isključite sa naponskog napajanja. OPASNOST PO ŽIVOT USLED STRUJNOG UDARA! Izmenjivač isključite sa naponskog napajanja. De-energising inverter:. OFF ON 2. 3. 4. 5. Switch off DC side at Inverter 2 3 OFF Switch off - AC side - S0/AL-Out Safeguard Disconnect DC side 5 min Wait 5 minutes

I/S k/s L/P K/P I/S k/s L/P K/P I/S k/s L/P K/P Connecting AC and DC side Connecting AC side and current sensor 3.0 Connecting DC side 3.0-8.5 MC4 0-20 SUNCLIX Second ground connection inside or outside is mandatory for PIKO 3.0 4.2-20 L.k L.l L2.k L2.l L3.k L3.l k L/P2 l k L/P2 l k L/P2 l Stromwandler 50 A 3x VA KI. 2 L 2 2 L 2 2 2 L 3 2 DSL / Sensor AC L L2 L3 LAN 4 5

Country-specific installation Connecting main cable with sealing cap Second ground connection 3 Nm NOTE For PIKO 3.0 the second ground connection inside or outside 6 is mandatory. 7

Option: Connecting DC & DC2 in parallel Data transfer communication board II DC DC2 DSL or LAN NOTE For PIKO 3.0 and 4.2 the parallel connection is not possible.. NOTE When using the parallel connection this feature must be activated under the menue Settings >> Service menu >> String 8 connection >> Parallel connection (only with service code). 9

Commissioning the inverter. 2. ON ON 5 Nm or 3. OFF ON 20 2

Installation Assistent* Language English. Select language 2. Enter 3. Enter Date / time > 4. Enter Language English > Select Enter 5. Select string connection 6. Enter 7. Select modus of the current sensor 8. Enter Country setting Do you really want to apply this country? No Yes 9. Select country 0. Enter. 2. Enter Confirm Country settings with YES 22 * Deviations due to software versions (UI level) is possible. 23

Menu overview* DC and AC DC menu AC menu DC menu DC input (V, I, P) DC input 2 (V, I, P) DC input 3 (V, I, P) Settings menu Self consumption menu * Depending on the inverter type and software version of the communication board, the menu may differ. AC menu Phase (V, I, P) Phase 2 (V, I, P) Phase 3 (V, I, P) Yield Power (W) Daily yield (kwh) Total yield (kwh) Grid parameters Limitation on (%) Grid frequency (z) cos phi Daily yield (diagram) Monthly yield (diagram) Annual yield (diagram) Total yield (diagram) 24 25

Settings menu Basic settings Language Select language Inverter name Entering the name Date / time Set date / Set time Communication Network settings Auto IP / DCP Network settings 2 IP address / Subnet mask Router setting External router / IP address RS485 setting Bus termination / Bus bias voltage / RS485 address Portal configuration Data export / Portal code Event messages Immediately mailing Device information SW-/W-version FW / W / UI / PAR Serial number Serial number Event list Event list Country setting Country setting Function test Fan test Start test Service menu Service code Entering service code 2 Factory setting Reset to factory settings Variations due to software versions (UI level) are possible. 2 After entering the code, additional menu items appear to configure the inverter. The code can be obtained by electricians from our customer service. 26 27

Own consumption menu Daily self-consumption Self-consumption (Wh) Self-consumptions rate (%) Self-sufficiency (%) Total self-consumption Self-consumption (Wh) Self-consumptions rate (%) Self-sufficiency (%) Current build. consump. Solar generator (W) Battery (W) Grid (W) Phase-sel. consumption Phase (W) Phase 2 (W) Phase 3 (W) 28 29

Technical data PIKO 3.0-8.5* *This manual is subject to technical changes and printing errors. You can find current informa tion on our website www.kostal-solar-electric.com. PIKO Inverter Inverter Unit 3.0 4.2 4.6 5.5 7.0 8.5 Input side (DC) Inverter type PIKO PIKO PIKO PIKO PIKO PIKO Max. PV power (cos φ = ) kwp 4.3 4.6 5. 6. 7.7 9.4 MPP range with rated DC power (sym) V 270-730 400-800 265-800 265-800 330-800 400-800 MPP range with rated DC power (unsym) V 400-800 265-800 265-800 330-800 400-800 Max. input voltage (V DCmax ) V 900 000 000 000 000 000 Min. input voltage (V DCmin ) V 60 60 60 60 60 60 Rated input current A 2 6.33 7.35 8.3 0.56 2.9 Max. input current (I DCmax ) A 2.5 Max. input current with parallel connection A 22 22 22 22 Number of DC inputs 2 2 2 2 Number of independent MPP trackers 2 2 2 2 Output side (AC) Rated output, cos φ = (P AC,r ) kw 3 4.2 4.6 5.5 7.0 8.5 Max. output apparent power, cos φ, adj kva 3 4.2 4.6 5.5 7.0 8.5 Rated output current A 3 6. 6.7 8.0 0.2 2.3 Max. output current (I ACmax ) A 3.7 6. 6.7 8.0 0.2 2.5 Short circuit current / peak A 26.4/6.9 9.5/6.7 2.5/8.8 2.5/8.8 5.8/.2 7.7/2.5 30 3

PIKO Inverter Inverter Unit 3.0 4.2 4.6 5.5 7.0 8.5 Output side (AC) Number of feed-in phases 3 Grid connection N~, AC, 230 V 3N~, AC, 400 V Rated frequency (f r ) z 50 50 Efficiencies Max. efficiency % 96.2 97.5 97.7 97.7 97.6 97.6 Max. European efficiency rate % 95.5 96. 96.3 96.3 96.5 96.5 System data Topology: without galvanic separation - transformerless Internal protection according to IEC 60529 housing / fan IP 65 / IP 55 Protective class according to IEC 6203 Overvoltage category according to IEC 60664- Input side (PV generator) Overvoltage category according to IEC 60664- Output side (grid connection) Pollution Degree 4 Enviromental category (outdoor installation) Enviromental category (interior installation) UV resistance I II III 32 33

PIKO Inverter Inverter Unit 3.0 4.2 4.6 5.5 7.0 8.5 System data Minimum cable cross-section of AC connecting line mm² 2.5.5.5.5 2.5 2.5 Minimum cable cross-section of DC connecting line mm² 4 Max. fusing on output side B6, C6 B6, C6 B6, C6 B6, C6 B6, C6 B6, C6 Tightening torque of PE connection, outer Nm 3 Tightening torque of lid screws Nm 5 Operator protection according to EN 6209-2 Electronic disconnection device integrated RCCB type B eight mm (in) 385 (5.2) 385 (5.2) 385 (5.2) 385 (5.2) 385 (5.2) 385 (5.2) Width mm (in) 500 (9.7) 500 (9.7) 500 (9.7) 500 (9.7) 500 (9.7) 500 (9.7) Depth mm (in) 222 (8.7) 236 (9.29) 236 (9.29) 236 (9.29) 236 (9.29) 236 (9.29) Weight kg (lb) 22 (48.5) 24 (52.9) 25,5 (56.22) 25,5 (56.22) 26,5 (58,42) 26,5 (58,42) Max. air throughput m³/h 84 84 84 84 Max. noise emission dba < 33 43 52 52 52 52 Ambient temperature C (F ) -20...60 (-4...40) Max. installation altitude m above sea level Relative humidity (condensing) % 4 00 Connection technology at input side MC 4 Connection technology at output side spring-loaded terminal strip 34 35 2000

PIKO Inverter Inverter Unit 3.0 4.2 4.6 5.5 7.0 8.5 Various Warranty Years 5 Warranty extension optional Years 0 / 20 Ext. current sensor (MBS ASRD 4) Rated current primary (Peak/RMS) A 50/35 Precision method Connected power PIKO kw 27 Dimensions ( x W x D) mm (in) 90 x 05 x 54 (3.5 x 4. x 2.) Max. cable diameter mm (in) 3.5 (0.5) Mounting on top hat rail to DIN EN 6075 It is important that the maximum current load of the DC connector will not be exceeded in a parallel circuit (max. 30 A). This could lead to damage of the device. If the DC string input current is higher than the maximum current load of the plug (see manufacturer s instructions), both DC inputs must be used. 36 37

Technical data PIKO 0-20* *This manual is subject to technical changes and printing errors. You can find current informa tion on our website www.kostal-solar-electric.com. PIKO Inverter Inverter Unit 0 2 5 7 20 Input side (DC) Inverter type PIKO PIKO PIKO PIKO PIKO Max. PV power (cos φ = ) kwp 0.8 2.9 6.9 9.2 22.6 MPP range with rated DC power (sym) V 290-800 345-800 260-800 290-800 345-800 MPP range with rated DC power (unsym) V String : 390-800 (max. 20A) String 2: 250-800 (max.0a) String : 490-800 (max. 20A) String 2: 250-800 (max.0a) String &2: 325-800 (max.20a) String 3: 250-800 (max.0a) Max. input voltage (V DCmax ) V 000 Min. input voltage (V DCmin ) V 60 String &2: 375-800 (max. 20A) String 3: 250-800 (max.0a) String &2: 450-800 (max.20a) String 3: 250-800 (max.0a) Rated input current A 5. 8. 22.74 25.77 30.32 Max. input current (I DCmax ) A sym: 8/8, unsym: 20/0 sym: 8/8, unsym: 20/0 Max. input current with parallel connection A 36 (DC+DC2) 36 (DC+DC2) sym.: 20/20/20 unsym.: 20/20/0 40 (DC+DC2) / 20 (DC3) sym.: 20/20/20 unsym.: 20/20/0 40 (DC+DC2) / 20 (DC3) sym.: 20/20/20 unsym.: 20/20/0 Number of DC inputs 2 2 3 3 3 Number of independent MPP trackers 2 2 3 3 3 Output side (AC) Rated output, cos φ = (P AC,r ) kw 0 2 5 7 20 Max. output apparent power, cos φ, adj kva 0 2 5 7 20 40 (DC+DC2) / 20 (DC3) 38 39

PIKO Inverter Inverter Unit 0 2 5 7 20 Output side (AC) Rated output current A 4.6 7.4 2.7 24.6 29 Max. output current (I ACmax ) A 6.2 9.3 24.2 27.4 32.2 Short circuit current / peak A 25/6.6 27.4/6.7 42/28.5 4.3/29 5/36.5 Number of feed-in phases 3 Grid connection 3N~, AC, 400 V Rated frequency (f r ) z 50 Efficiencies Max. efficiency % 97.7 97.7 98.0 98.0 98.0 Max. European efficiency rate % 97. 97. 97.2 97.3 97.3 System data Topology: without galvanic separation - transformerless Internal protection according to IEC 60529 housing / fan IP 65 / IP 55 Protective class according to IEC 6203 Overvoltage category according to IEC 60664- Input side (PV generator) Overvoltage category according to IEC 60664- Output side (grid connection) Pollution Degree 4 I II III 40 4

PIKO Inverter Inverter Unit 0 2 5 7 20 System data Enviromental category (outdoor installation) Enviromental category (interior installation) UV resistance Minimum cable cross-section of AC connecting line mm² 4 4 6 6 6 Minimum cable cross-section of DC connecting line mm² 4 Max. fusing on output side B25, C25 B25, C25 B32, C32 B32, C32 B40, C40 Tightening torque of PE connection, outer Nm 3 Tightening torque of lid screws Nm 5 Operator protection according to EN 6209-2 Electronic disconnection device integrated Relative humidity (condensing) % 4 00 42 43 RCCB type B eight mm (in) 445 (7.5) 445 (7.5) 540 (2.26) 540 (2.26) 540 (2.26) Width mm (in) 580 (22.8) 580 (22.8) 700 (27.56) 700 (27.56) 700 (27.56) Depth mm (in) 248 (9.8) 248 (9.8) 265 (0.43) 265 (0.43) 265 (0.43) Weight kg (lb) 37.5 (82.7) 37.5 (82.7) 48.5 (06.92) 48.5 (06.92) 48.5 (06.92) Max. air throughput m³/h 2x48 2x48 2x84 2x84 2x84 Max. noise emission dba 43 44 56 56 56 Ambient temperature C (F ) -20...60 (-4...40) Max. installation altitude m above sea level 2000

PIKO Inverter Inverter Unit 0 2 5 7 20 System data Connection technology at input side SUNCLIX Connection technology at output side spring-loaded terminal strip Various Warranty Years 5 Warranty extension optional Years 0 / 20 Ext. current sensor (MBS ASRD 4) Rated current primary (Peak/RMS) A 50/35 Precision method Connected power PIKO kw 34.5 Dimensions ( x W x D) mm (in) 90 x 05 x 54 (3.5 x 4. x 2.) Max. cable diameter mm (in) 3.5 (0.5) Mounting on top hat rail to DIN EN 6075 It is important that the maximum current load of the DC connector will not be exceeded in a parallel circuit (max. 30 A). This could lead to damage of the device. If the DC string input current is higher than the maximum current load of the plug (see manufacturer s instructions), both DC inputs must be used. 44 45

Notes 46 47

Service otline Germany and other countries +49 76 47 74 42 22 France +33 638 47 Greece +30 230 477 555 Italy +39 0 97 82 420 Switzerland +4 32 5800 225 Spain 2 +34 96 824 927 Turkish 3 +90 22 803 06 26 Language: German, English 2 Language: Spanish, English 3 Language: Turkish, English 2 / 207 - MA 03997-000 Subject to technical changes and printing errors You can find current information at www.kostal-solar-electric.com Manufacturer: KOSTAL Industrie Elektrik Gmb, agen, Germany