Solenoid valves for drinking water Types EV220BW and EV228BW

Similar documents
Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Assisted lift operated 2/2-way solenoid valves Type EV251B

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Solenoid valve Types EV220B 15 - EV220B 50

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Servo-operated 2/2-way solenoid valves for high pressure

Servo piston operated 2/2-way solenoid valves for steam Type EV245B

Servo-operated 2/2-way solenoid valves Type EV220A

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Solenoid valves 2/2-way servo operated type EV220B 15 50

Solenoid valve Types EV220B 15 - EV220B 50

Assisted lift operated 2/2-way solenoid valves Type EV250B

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

2/2-way assisted lift operated solenoid valve type EV250B

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Solenoid valves 2/2-way servo-operated Type EV220B 15-50

Solenoid valves 2/2-way direct-operated Type EV210B

Servooperated. 2/2-way solenoid valves EV220A. The Home of Control & Automation in Ireland

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210A DKACV.PD.100.A B1023. August 2001

Solenoid valves 3/2-way direct-operated Type EV310A

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Solenoid coils. Data sheet

Solenoid coils. Data sheet

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid coil Types BB, BE, BF, BG, and BN

Coils for solenoid valves

Easy. Core Industrial Products for Distributors and Wholesalers. selection of future proof products. iasupport.danfoss.com

Solenoid valves Type EVU

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

Solenoid coil for control in potentially explosive areas Type BZ

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

Solenoid valve Types EVR 2 EVR 40 NC/NO

Solenoid valves Type EVU for fluorinated refrigerants

Pilot valves for servo opereated main valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

MAKING MODERN LIVING POSSIBLE. Coils for solenoid valves. Technical brochure

Externally operated valves Type AV210

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valve VDHT standard BSP (British Standard Pipe)

Solenoid valves VZWP, servo-controlled

Solenoid System FLANGE MOUNTING VERSION

Coils for solenoid valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

Solenoid valves VZWM-L, NPT

Pilot valves for servo operated main valves

Pressostats and thermostats CAS

Solenoid valves EVRA and EVRAT

PILOT OPERATED, 2/2 WAY, NORMALLY CLOSED, G 3/4 - G1. Pressure. Pressure Maximum For DC Voltage. Flow Coeffient. Maximum. For AC Voltage. L/m.

how to use solenoid valves INDUSTRIAL CONTROLS DKACV.PS.600.A3.02 / 520B1389

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

MULTI-FLUID SOLENOID VALVES 1/8 AND 1/4

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Technical Data Sheet

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Pilot valves for servo operated main valves

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

EVI 5 S13 Solenoid System

Water Solenoid Valves for Appliances

2/2 Pressure operated valves

Solenoid valves type EVR 2 40 NC / NO

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

82170/ /2-way diaphgram valves

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

2/2-way Solenoid Valve for liquids and gases

Solenoid valve 2/2 way N.C. With pilot control

Solenoid valves VZWM-L

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Core Industrial Products for Distributors and Wholesalers in North America

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

GEMÜ 205 Electrically operated solenoid valve

Condensed Catalog 2006 North America

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Electric Expansion Valve Type AKVO 10

Technical Principles of Valves

System 13. ü ( System 13

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

High Pressure Valves

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

Solenoid valves type EVRA 3 to 40 and EVRAT 10 to 20

APPLICATION OF SYSTEM 8

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

Transcription:

Data sheet Solenoid valves for drinking water Types EV220BW and EV228BW Solenoid valve range with drinking water approvals For water supply Houses and large apartments - Kitchen and bathrooms Commercial buildings Industrial buildings Zoning Laundry Diswashing Main inlet valves Machines and food processing Features and versions y Clip-on coil y Flow range for water in Kv: 4 40 m³ / h y Differential pressure: 0.3 0 bar y Media temperature from 0 90 C y Ambient temperature: Up to 80 C y Coil enclosure: IP65 y Thread connections: From G /2 G 2 y DN 5 50 y Water hammer damped y Built-in filter y Body material in ECO brass (Lead free < 0, %) or Stainless steel y New generation sealings recommended for drinking water y Valves are certified by RISE, notified body 002. Valid in Denmark and Sweden. In accordance with Boverket Building Regulations (BBR 2, 204-06-7). Certificate number SCO55-8 y Valves are certified by SINTEF Valid in Norway In accordance with NKB Product rules nr. 3, pkt. 3.2-3.6 - NT VVS 00, pkt. 6.4.2 og 6.4.8 - EN ISO 6509 y Inspection by DTI y EV220BW 5-25 ECO brass NC/NO y EV220BW 5-50 SS NC/NO y EV228BW 5-25 ECO brass UN (Latching) y EV228BW 5-50 SS UN (Latching) IC.PD.200.I2.02

EV220BW 5-25 ECO brass valve body, NC y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 - Pressure Equipment Directive 204/68/EU y RoHS Directive 20/65/EU y Wetted materials in accordance with BBR, DVGW, 4MS (4 member states Germany, Holland, France and UK), KTW and W270 y Certified by RISE y Certified by SINTEF y Inspection by DTI 002 CERTIFIERAD 356 DTI ISO228/ connection Seal material Orifice size K v - value Media temperature Differential pressure [mm] [m³/ h] [ C] [Bar] G ½ 5 4 0 90 0.3 0 32U500 G ¾ 20 8 0 90 0.3 0 32U2000 G 25 0 90 0.3 0 32U2500 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. ON OFF 24h Technical data Main Type EV220BW 5 BE EV220BW 20 BE EV220BW 25 BE Time to open [ms] ) 40 40 300 Time to close [ms] ) 350 000 000 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Closing times can be changed by replacement of the equalizing orifice. Installation Max. working pressure (MWP) Max. test pressure Ambient temperature Viscosity Materials Optional, but vertical solenoid system is recommended 0 bar 25 bar BB DC Up to 50 C BB AC Up to 80 C EEC BE240CS Up to 55 C Max. 50 cst Valve body / cover ECO brass CW724R Armature Stainless steel W.no..405 / AISI 430 FR Armature tube Stainless steel W.no..4306 / AISI 304 L Armature stop Stainless steel W.no..405 / AISI 430 FR Springs Stainless steel W.no..430 / AISI 30 Equalizing orifice ECO brass CW724R O-rings Valve plate Diaphragm IC.PD.200.I2.02 2

EV220BW 5-50 SS valve body NC y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 - Pressure Equipment Directive 204/68/EU y RoHS Directive 20/65/EU y Wetted materials in accordance with BBR, DVGW, 4MS (4 member states Germany, Holland, France and UK), KTW and W270 y Certified by RISE y Certified by SINTEF y Inspection by DTI 002 CERTIFIERAD 356 DTI ISO228/ connection Seal material Orifice size K v - value Media temperature Differential pressure [mm] [m³/ h] [ C] [Bar] G ½ 5 4 0 90 0,3 0 32U580 G ¾ 20 8 0 90 0,3 0 32U2080 G 25 0 90 0,3 0 32U2580 G /4 32 8 0 90 0,3 0 32U3280 G ½ 40 24 0 90 0,3 0 32U4080 G 2 50 40 0 90 0,3 0 32U5080 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. ON OFF 24h Technical data Main Type EV220BW EV220BW EV220BW EV220BW EV220BW EV220BW Time to open [ms] ) 40 40 300 000 500 5000 Time to close [ms] ) 350 000 000 2500 4000 0000 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Closing times can be changed by replacement of the equalizing orifice. Installation Max. working pressure (MWP) Max. test pressure Ambient temperature Viscosity Materials Optional, but vertical solenoid system is recommended 0 bar 25 bar BB DC Up to 50 C BB AC Up to 80 C EEC BE240CS Up to 55 C Max. 50 cst Valve body / cover Stainless Steel W. no..4404 / AISI36L Armature Stainless steel W.no..405 / AISI 430 FR Armature tube Stainless steel W.no..4306 / AISI 304 L Armature stop Stainless steel W.no..405 / AISI 430 FR Springs Stainless steel W.no..430 / AISI 30 Equalizing orifice Stainless steel W. no..4435 / AISI 36L O-rings Valve plate Diaphragm IC.PD.200.I2.02 3

Function, NC 7 Pos. no. Description Coil 2 Armature spring 3 Valve plate 4 Pilot orifice 5 Diaphragm 6 Main orifice 7 Equalizing orifice Coil voltage disconnected (closed): When the voltage is disconnected, the valve plate (3) is pressed down against the pilot orifice (4) by the armature spring (2). The pressure across the diaphragm (5) is built up via the equalizing orifice (7). The diaphragm closes the main orifice (6) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will be closed for as long as the voltage to the coil is disconnected. Coil voltage connected (open): When voltage is applied to the coil (), the pilot orifice (4) is opened. As the pilot orifice is larger than the equalizing orifice (7), the pressure across the diaphragm (5) drops and therefore it is lifted clear of the main orifice (6). The valve is now open for unimpeded flow and will be open for as long as the minimum differential pressure across the valve is maintained, and for as long as there is voltage to the coil. IC.PD.200.I2.02 4

EV220BW 5-25 ECO brass valve body NO y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 - Pressure Equipment Directive 204/68/EU y RoHS Directive 20/65/EU y Wetted materials in accordance with BBR, DVGW, 4MS (4 member states Germany, Holland, France and UK), KTW and W270 y Certified by RISE y Certified by SINTEF y Inspection by DTI 002 CERTIFIERAD 356 DTI ISO228/ connection Seal material Orifice size K v - value Media temperature Differential pressure [mm] [m³/ h] [ C] [Bar] G ½ 5 4 0 90 0.3 0 32U50 G ¾ 20 8 0 90 0.3 0 32U200 G 25 0 90 0.3 0 32U250 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. ON OFF 24h Technical data Main Type EV220BW 5 BE EV220BW 20 BE EV220BW 25 BE Time to open [ms] ) 40 40 300 Time to close [ms] ) 350 000 000 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Closing times can be changed by replacement of the equalizing orifice. Installation Max. working pressure (MWP) Max. test pressure Ambient temperature Viscosity Materials Optional, but vertical solenoid system is recommended 0 bar 25 bar BB DC Up to 50 C BB AC Up to 80 C EEC BE240CS Up to 55 C Max. 50 cst Valve body / cover ECO brass CW724R Armature Stainless steel W.no..405 / AISI 430 FR Armature tube Stainless steel W.no..4306 / AISI 304 L Armature stop Stainless steel W.no..405 / AISI 430 FR Springs Stainless steel W.no..430 / AISI 30 Equalizing orifice ECO brass CW724R O-rings Valve plate Diaphragm IC.PD.200.I2.02 5

EV220BW 5-50 SS valve body NO y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 - Pressure Equipment Directive 204/68/EU y RoHS Directive 20/65/EU y Wetted materials in accordance with BBR, DVGW, 4MS (4 member states Germany, Holland, France and UK), KTW and W270 y Certified by RISE y Certified by SINTEF y Inspection by DTI 002 CERTIFIERAD 356 DTI ISO228/ connection Seal material Orifice size K v - value Media temperature Differential pressure [mm] [m³/ h] [ C] [Bar] G ½ 5 4 0 90 0,3 0 32U58 G ¾ 20 8 0 90 0,3 0 32U208 G 25 0 90 0,3 0 32U258 G /4 32 8 0 90 0,3 0 32U328 G ½ 40 24 0 90 0,3 0 32U408 G 2 50 40 0 90 0,3 0 32U508 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. ON OFF 24h Technical data Main Type EV220BW EV220BW EV220BW EV220BW EV220BW EV220BW Time to open [ms] ) 40 40 300 000 500 5000 Time to close [ms] ) 350 000 000 2500 4000 0000 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Closing times can be changed by replacement of the equalizing orifice. Installation Max. working pressure (MWP) Max. test pressure Ambient temperature Viscosity Materials Optional, but vertical solenoid system is recommended 0 bar 25 bar BB DC Up to 50 C BB AC Up to 80 C EEC BE240CS Up to 55 C Max. 50 cst Valve body / cover Stainless steel W. no..4404 / AISI 36L Armature Stainless steel W.no..405 / AISI 430 FR Armature tube Stainless steel W.no..4306 / AISI 304 L Armature stop Stainless steel W.no..405 / AISI 430 FR Springs Stainless steel W.no..430 / AISI 30 Equalizing orifice Stainless steel W. no..4435 AISI 36L O-rings Valve plate Diaphragm IC.PD.200.I2.02 6

Function, NO 7 Pos. no. Description Coil 2 Armature 3 Valve plate 4 Pilot orifice 5 Diaphragm 6 Main orifice 7 Equalizing orifice Coil voltage disconnected (closed): When the voltage to the coil () is disconnected, the pilot orifice (4) is open. As the pilot orifice is larger than the equalizing orifice (7), the pressure across the diaphragm (5) drops and therefore it is lifted clear of the main orifice (6). The valve will be open for as long as the minimum differential pressure across the valve is maintained, and for as long as the voltage to the coil is disconnected. Coil voltage connected (open): When voltage is applied to the coil, the valve plate (3) is pressed down against the pilot orifice (4). The pressure across the diaphragm (5) is built up via the equalizing orifice (7). The diaphragm closes the main orifice (6) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will be closed for as long as there is voltage to the coil. IC.PD.200.I2.02 7

EV228BW 5-25 ECO brass valve body UN, latching y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 - Pressure Equipment Directive 204/68/EU y RoHS Directive 20/65/EU y Wetted materials in accordance with BBR, DVGW, 4MS (4 member states Germany, Holland, France and UK), KTW and W270 y Certified by RISE y Certified by SINTEF y Inspection by DTI 002 CERTIFIERAD 356 DTI ISO228/ connection Seal material Orifice size K v - value Media temperature Differential pressure [mm] [m³/ h] [ C] [Bar] G /2 5 4 0 60 0.3 0 32U2400 G 3/4 20 8 0 60 0.3 0 32U2402 G 25 0 60 0.3 0 32U2404 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. ON OFF 24h Technical data Main Type EV228BW EV228B 20B EV228B 25B Time to open [ms] ) 40 40 300 Time to close [ms] ) 350 000 000 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Closing times can be changed by replacement of the equalizing orifice. Installation Optional, but vertical solenoid system is recommended Max. working pressure (MWP) 0 bar Ambient temperature Up to 50 C Viscosity Max. 50 cst Valve body / cover ECO brass CW724R Armature Stainless steel W.no..405 / AISI 430 FR Armature tube Stainless steel W.no..4306 / AISI 304 L Armature stop Stainless steel W.no..405 / AISI 430 FR Materials Springs Stainless steel W.no..430 / AISI 30 Equalizing orifice ECO brass CW724R O-rings Valve plate Diaphragm Switch power (on/off) 08F7396 (2V DC) IC.PD.200.I2.02 8

EV228BW 5-50 SS valve body UN, latching y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 - Pressure Equipment Directive 204/68/EU y RoHS Directive 20/65/EU y Wetted materials in accordance with BBR, DVGW, 4MS (4 member states Germany, Holland, France and UK), KTW and W270 y Certified by RISE y Certified by SINTEF y Inspection by DTI 002 CERTIFIERAD 356 DTI ISO228/ connection Seal material Orifice size K v - value Media temperature Differential pressure [mm] [m³/ h] [ C] [Bar] G ½ 5 50 4 0 60 0.3 0 32U240 G ¾ 20 50 8 0 60 0.3 0 32U2403 G 25 50 0 60 0.3 0 32U2405 G /4 32 50 8 0 60 0.3 0 32U2407 G ½ 40 50 24 0 60 0.3 0 32U2409 G 2 50 50 40 0 60 0.3 0 32U24 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. ON OFF 24h Technical data Main Type EV220BW EV220BW EV220BW EV220BW EV220BW EV220BW Time to open [ms] ) 40 40 300 000 500 5000 Time to close [ms] ) 350 000 000 2500 4000 0000 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Closing times can be changed by replacement of the equalizing orifice. Installation Optional, but vertical solenoid system is recommended Max. working pressure (MWP) 0 bar Max. test pressure 25 bar Ambient temperature BB DC Up to 50 C Viscosity Max. 50 cst Valve body / cover Stainless steel w. no..4404 / AISI 36L Armature Stainless steel W.no..405 / AISI 430 FR Armature tube Stainless steel W.no..4306 / AISI 304 L Armature stop Stainless steel W.no..405 / AISI 430 FR Materials Springs Stainless steel W.no..430 / AISI 30 Equalizing orifice Stainless steel W. no..4435 / AISI 36L O-rings Valve plate Diaphragm IC.PD.200.I2.02 9

Function UN, latching 8 + Fig. a 7 When (minus) is supplied to the left terminal pin and + (plus) to the right (see fig. a), the valve plate is pressed down against the pilot orifice (4) by the armature spring (2). The pressure across the diaphragm (5) is built up via the equalizing orifice (7). The diaphragm closes the main orifice (6) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will stay closed, until the poles are switched (see fig. b). Pos. no. Description Coil 2 Armature spring 3 Valve plate 4 Pilot orifice 5 Diaphragm 6 Main orifice 7 Equalizing orifice 8 Permanent magnet + Fig. b Switching poles When + (plus) is supplied to the left terminal pin and (minus) to the right (see fig. b), the pilot orifice (4) is opened. As the pilot orifice is larger than the equalizing orifice (7), the pressure across the diaphragm (5) drops and therefore it is lifted clear of the main orifice (6). The valve is now open for flow and will stay open as long as the minimum differential pressure across the valve is maintained, until the poles are switched back (see fig. a). IC.PD.200.I2.02 0

Dimensions and weight Danfoss 32U783.0 Type L B B [mm] / coil type H H Weight without coil [mm] [mm] BA BB / BE BG / BO BP [mm] [mm] [kg] EV220/228BW 5 80.0 52.0 32 46 68 45 99 5.0 0.7 EV220/228BW 20 90.0 58.0 32 46 68 45 03 8.0 0.9 EV220/228BW 25 09.0 70.0 32 46 68 45 3 22.0.3 EV220/228BW 32 20.0 82.0 32 46 68 45 20 27.0 2.0 EV220/228BW 40 30.0 95.0 32 46 68 45 29 32.0 3.0 EV220/228BW 50 62.0 3.0 32 46 68 45 35 37.0 4.8 Mounting angle EV228BW EV228BW EV220BW EV220BW IC.PD.200.I2.02

Capacity diagrams: Example, water: Capacity for EV220BW 5B at differential pressure of 3 bar. Approx. 7 m 3 /h EV220/228BW 5 NC/NO/UN EV220/228BW 20 NC/NO/UN EV220/228BW 32 NC/NO/UN EV220/228BW 25 NC/NO/UN EV220/228BW 40 NC/NO/UN EV220/228BW 50 NC/NO/UN IC.PD.200.I2.02 2

BB / BY, High performance coils y Enclosure: - IP00 version with DIN 43650 A spade connectors - IP20 version with protective cap - IP65 version with mounted cable plug y In accordance with: - RoHS Directive 20/65/EU - Low Voltage Directive 204/35/EU - EN60730- - EN60730-2-8 Type Supply Tambient voltage Voltage Frequency Power consumption Control variation [ C] [V] [Hz] [W] [VA] BB024AS -40 80 24-5%, +0% 50 NO, NC 9 08F7358 BB230AS -40 80 220-230 -5%, +0% 50 NO, NC 9 08F735 BB02DS -40 50 2 ±0% DC NC, NO, UN (Latching) 3 08F7396 BB024DS -40 50 24 ±0% DC NC, NO, UN (Latching) 6 08F7397 Technical data Design In accordance with VDE 0580 Insulation of coil windings Class H according to IEC 85 Connection Spade connector in accordance with DIN 43650 form A Enclosure, IEC 529 IP00 with spade connector, IP20 with protective cap, IP65 with cable plug Duty rating Continuous Plug type Cable plug (042N056) Dimensions and weight L without cable plug L with protective cap L with cable plug Weight [mm] [mm] [mm] [kg] 62 77 85 0.24 IC.PD.200.I2.02 3

Accessories: Cable plug Type, Form A GDM 20 (grey) cable plug according to DIN 43650-A PG 042N056 EEC Electronic coil controller EEC electronic coil controller for solenoid valves, type EV220B. The EEC gives the coil a short over-boost, and controls the armature speed: y Low power consumption (holding power: 4 W) y Reduced noise during operation y Increased MOPD compared to standard coils y Increased lifetime of the solenoid valve y Enclosure: - IP67 version y In accordance with: - Low Voltage Directive 204/35/EU - EN60730- Type BE240CS -25 55 Supply voltage Power consumption Tambient Voltage Frequency Control variation [ C] [V] [Hz] [W] 208-240 ±0% 60 NC, NO 4 208-240 ±0% 50 NC, NO 4 08F6783 IC.PD.200.I2.02 4