SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

Similar documents
MOTOR SCM ISO

SCM M2. Other advantages:

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

MOTOR SCM M2

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

SCM DIN. Other advantages:

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

Hydraulic pumps, motors and accessories. The solution for all your hydraulic needs

Hydraulic pumps, motors and accessories. The solution for all your hydraulic needs

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

Hydraulic pumps, motors and accessories. The solution for all your hydraulic needs

Axial Piston Fixed Motor A2FM

Axial piston variable pump A7VO

Fixed Displacement Bent Axis Axial Piston Pumps TPB 70 - TAP 70

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Radial piston hydraulic motor Hägglunds CAb

Pump SCP / SCPT 090,130 DIN, SAE

Radial piston motor for compact drives MCR-C

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

Axial piston fixed motor A2FM Series 70 A2FE Series 70

Axial Piston Fixed Pump A2FO

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

Radial piston motor for compact drives MCR-C

6.3 SIZE 2. Ordering Code External Gear Pump

TXV - Characteristics

Variable displacement axial piston pumps,

Axial Piston Fixed Pump A17FNO Series 10

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Radial piston motors for industrial applications MCR-D

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Hydraulic Motor/Pump Series F11/F12 zp12

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Radial piston motor for frame integrated drives MCR-A

Hydraulic Motor Series V12 Variable Displacement

Series TMM Axial Piston Motor. Technical Information

TMF 600 ( cm³/rev.)

Fixed Displacement Pump A2FO

Fixed Displacement Motor AA2FM (A2FM)

Radial piston motor for track drives MCR-T

TPF 60 (36,16 49,94 cm³/rev.)

HYDRAULIC-MOTORS. Radial Piston Motors with fixed displacement RM...X series V g = 250 cm 3 /rev cm 3 /rev

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries

Axial piston fixed motor A2FM for explosive areas II 2G ck IIB Tx

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95

US version. Drain connection

Torque. Motor model R

Fixed Displacement Motor A2FM

Axial piston variable pump (A)A4VSO

Fixed Displacement Plug-In Motor A2FE

Radial piston motor for heavy duty wheel drives MCR-W

External Gear Pumps Series F

C9: BMM, BMP, BMR, BMH, BMJ Series & Valves CONTENT. Usage Guide 2. BMM Series Hydraulic Motors 3. BMP Series Hydraulic Motors 11

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Pump Series F1plus Fixed Displacement

Axial Piston Fixed Displacement Pump KFA

Axial Piston Variable Double Pump A8VO

Hydraulic Motor/Pump Series F11/F12

HYDRAULIC MOTORS EPMS - series 3

GEAR PUMPS DIMENSIONAL DETAILS

Ordering Code of 2PBA Pumps

CONTENT Axial Piston Motors and Pumps Fixed Displacement. Technical Specification Guide...2. Hydraulic motor MAP Hydraulic motor MAP50...

External gear pump Series G

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Axial piston fixed pump AA2FO

1.3 HIGH PRESSURE SERIES

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

Variable Plug-In Motor A6VE

Hydraulic Fixed Piston Rexroth A2FE Motor

Radial piston motor for wheel drives MCR-F

» Feeding mechanism of robots and manipulators;» Metal working machines;» Textile machines;» Machines for agriculture;» Food industries;

Fixed Plug-In Motor A2FE

Variable displacement axial piston pumps,

Radial piston motor for integrated drives MCR-H

Axial Piston Fixed Pump A17FNO

HYDRAULIC MOTORS EPRM

AP212HP Cast Iron Gear Pumps

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

HYDRAULIC MOTORS MM APPLICATION OPTIONS CONTENTS GENERAL MOTORS

Axial Piston Variable Pump A18VLO Series 11

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

COMPACT. Series CA 50 - CA 210

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Series 20 Axial Piston Pumps. Technical Information

Variable Displacement Plug-In Motor A6VE

Axial Piston Variable Pump A2VK

2-Circuit Axial Piston Fixed Pump A18FDO

OMP Hydraulic Motor Versions

External gear motor High Performance AZMB

High Pressure Gear Motors KM 5

Brueninghaus Hydromatik Rexroth A2FO Pump & A2FM Motor

High Torque Low Speed Motors MR - MRE

Axial piston variable pump A10V(S)O Series 31

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Transcription:

SCM 010-130 ISO is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 ISO is of the bent-axis type with spherical pistons. The design results in a compact motor with few moving parts, high starting torque and high reliability. It covers the entire displacement range 10-130 cmᶟ rev. at a maximum pressure of bar. It s well dimensioned, double tapered roller bearings permit high shaft loads and lead to excellent speed characteristics. The motor s high level of reliability is based on the choice of materials, hardening methods, surface structures and the quality assured manufacturing process. Other advantages: High maximum speed Smooth operation over the entire speed range Available in many different configurations of shafts and connections High efficiency Speed sensor available as option Suitable for applications with high angular accelerations due to its high rotary stiffness 3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 1/13

Versions, main data Example SC M - 010 W - N - I41 - W25 - K3 G - 1 00 Line 1 2 3 4 5 6 7 8 9 10 Line SC Sunfab Compact, bent-axis design 1. Type M Motor 2. Displacement 010 012 017 025 034 040 047 056 064 084 090 108 130 3. Direction of rotation W Independent 4. Sealing N Nitrile H High pressure, nitrile V Viton 7. Connection cover S1 S2 S3 V1 V2 R1 K3 40 Mount flange vertical * 40 Mount flange horizontal * 40 threaded connection 90 Mount flange vertical * 90 Mount flange horizontal * Side connections, flanged * Combicover 90 side conn. thread. * According to SAE J518 code 62 010 012 017 025 034 040 047 056 064 084 090 108 130 - - - - - - - - - X X X X - - - - - X X X X - - - - X X X X X - - - - - - - - - - - - - - - - - X X X X - - - X X X X X X X X X X - - - X X X X X X X X X X X X X X X - - - - - - - - 5. Mounting flange ISO 3019-2 010 012 017 025 034 040 047 056 064 084 090 108 130 I41 ISO 4-h ø80 I42 ISO 4-h ø100 I43 ISO 4-h ø125 I44 ISO 4-h ø140 I45 ISO 4-h ø160 6. Shaft Spline DIN 5480 X X X - - - - - - - - - - - O O X X - - - - - - - - - - - - - X X X X - - - - - - - - - - - - - X X O O - - - - - - - - - O O X X 010 012 017 025 034 040 047 056 064 084 090 108 130 W20 W20x1.25x14x9g X X X - - - - - - - - - - W25 W25x1.25x18x9g X X X X O - - - - - - - - W30 W30x2x14x9g - - - X X X X X O - - - - W32 W32x2x14x9g - - - - - X X X O - - - - W35 W35x2x16x9g - - - - - X X X X X X - - W40 W40x2x18x9g - - - - - - - - - X X X X W45 W45x2x21x9g - - - - - - - - - O O X X Key DIN 6885 K20 ø 20 k6 X X X - - - - - - - - - - K25 ø 25 k6 X X X X O - - - - - - - - K30 ø 30 k6 - O O X X X X X O - - - - K35 ø 35 k6 - - - - - X X X X - - - - K40 ø 40 k6 - - - - - - - - - X X O O K45 ø 45 k6 - - - - - - - - - O O X X 8. Connections 010 012 017 025 034 040 047 056 064 084 090 108 130 G ISO G* X X X X X - - - - - - - - M Metric ** - - - X X X X X X X X X X U UN*** - X X X X X X X X X X X X * Only threaded connections ** Only flanged connections *** Only available for S covers 9. Additional 1 External drainage 10. Speed sensor 00 No speed sensor P1 S1 S2 Prepared for speed sensor Fitted speed sensor type PNP* Fitted speed sensor type NPN* 010 012 017 025 034 040 047 056 064 084 090 108 130 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X * See separate brochure Speed sensor hall for more information. X = Standard, preferred O = Contact Sunfab 3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 2/13

Motor SCM 010-130 ISO 010 012 017 025 034 040 047 056 064 084 090 108 130 Displacement cm 3 /rev 9.6 12.6 17.0 25.4 34.2 41.2 47.1 56.7 63.5 83.6 90.7 108.0 130.0 Working pressure max intermittent max continuous Revolutions max intermittent max continuous min continuous Power max intermittent max continuous bar rpm 8800 8000 kw 41 15 8800 8000 54 20 8800 8000 74 25 7000 6 Starting torque theoretical value Nm/bar 0.15 0.20 0.27 0.40 0.54 0.66 0.75 0.89 1.0 1.33 1.44 1.71 2.06 Moment of inertia (x 10-3 ) kg m 2 0.9 0.9 0.9 1.1 1.1 2.6 2.6 2.6 2.6 7.4 7.4 7.4 7.4 Weight kg 8.5 8.5 8.5 9.5 9.5 16.5 16.5 16.5 16.5 28.0 28.0 30.5 30.5 86 40 7000 6 115 55 6 5700 125 60 6 5700 145 65 6 5700 175 80 6 5700 195 90 5200 4700 215 100 5200 4700 230 110 5200 4700 275 130 5200 4700 285 135 Data concerning RPM are based on maximum premitted peripheral velocity of the tapered roller bearing. Max intermittent power data may vary dependent on application. For further information please contact Sunfab. Continuous power data are based on maximum output power without external cooling of the motor housing. Intermittent duty is defined as follows: max 6 seconds per minute, e g peak RPM when unloading or accelerating. 3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 3/13

3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 4/13

3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 5/13

3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 6/13

3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 7/13

3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 8/13

3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 9/13

General instructions Choice of shaft seal Temp. Max. housing pressure bar at rpm Motor SCM Code C 1000 2000 0 0 5000 6000 7000 8000 9000 010-034 N 75 5.5 2.7 1.8 1.4 1.1 0.9 0.8 0.7 0.6 H 75 24.6 12.3 8.2 6.1 4.9 4.1 3.5 3.1 2.7 V 90 5.5 2.7 1.8 1.4 1.1 0.9 0.8 0.7 0.6 040-064 N 75 5.5 2.7 1.8 1.4 1.1 0.9 0.8 H 75 24.6 12.3 8.2 6.1 4.9 4.1 3.5 V 90 5.5 2.7 1.8 1.4 1.1 0.9 0.8 084-130 N 75 3.8 1.9 1.3 1.0 0.8 0.6 H 75 17.2 8.6 5.7 4.3 3.4 2.9 V 90 3.8 1.9 1.3 1.0 0.8 0.6 Code according to page 2, Versions, main data Factors affecting the choice of shaft seal include the hydraulic motor housing pressure and the drainage oil temperature. The drainage oil should have a maximum temperature of 75 C with a Nitrile shaft seal and 90 C with a Viton shaft seal. These temperatures must not be exceeded. The housing pressure must be equal to or greater than the external pressure on the shaft seal. Shaft loads The life of the motor is highly dependent on the bearing life. The bearings are affected by operating conditions such as speed, pressure, oil viscosity and filtration. External load on the shaft, as well as its size, direction and location also affects the bearing life. D Optimal force direction of radial load Fa+ Fa- Fr F 20 A Pressure Anticlockwise rotation B Pressure Clockwise rotation 20 F SCM ISO Max recommended shaft loads Fr (radial) max 1 Distance D (to point of force) Fa (axial) + (at standstill/ 0 bar pressure) max Fa (axial) - (at standstill/ 0 bar pressure) max Fa (axial) + (at bar pressure) max 2 Fa (axial) - (at bar pressure) max 2 010 012 017 025 034 040 047 056 064 084 090 108 130 kn 7 7 7 8 8 8.5 8.5 9 9 12 12.5 12.5 13 mm 45 45 45 50 50 60 60 60 60 65 65 70 70 kn 3 3 3 3 3 4 4 4 4 5 5 5 5 kn 4 4 5 7 7 7 7 10 11 13 14 16 19 kn 4 4 5 7 7 7 7 10 11 13 14 16 19 kn 0 0 0 0 0 0 0 0 0 0 0 0 0 ¹) Fr (radial) max; Calculation based on running conditions: bar / 2000 rpm ¹) Fr (radial) max; Calculation based on optimal force direction (Fr max will be lower in other force directions) ¹) Fr (radial) max; In running conditions higher than bar and/or 2000 rpm the max limits for Fr (radial) max will be lower ²) Fa (axial) + Will increase bearing life ²) Fa (axial) - Will decrease bearing life For other forces, please contact Sunfab for advice. 3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 10/13 9 (12)

Temperatures/Housing cooling Excessive system temperature reduces the life of the shaft seal and can lower the oil viscosity below the recommended level. A system temperature of 60 C and a drain flow temperature of 90 C must not be exceeded. Cooling/flushing of the motor housing can be needed to keep the drain flow temperature at an acceptable level. Q Counter pressure valve Q flush Suggested flow: Motor SCM 010-034 Flushing l/min 2-8 Cont. RPM 2800 040-064 4-10 2500 084-130 6-12 2200 Counter pressure valve Q flush Q flush Housing flushing can be built up with the help of a flushing valve or taken directly from the return line. When the return pressure is too low this is compensated for by a counter pressure valve. The tank line is connected to the highest point as in the figure. Flushing valve Simplified circuits Installation The motor housing should be filled with oil to at least 50% before starting. The drainage pipe should be connected to topmost drainage outlet. The other end of the pipe should be connected to the oil tank at a point below the oil level. 3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 11/13 10 (12)

Piping Recommended oil velocity in pressure line max. 7 m/sec Filtering Cleanliness according to ISO norm 4406, code 16/13. Hydraulic fluids High performance oils meeting ISO specifications such as HM, DIN 51524-2 HLP, or better must be used. A min. viscosity of 10 cst is required to keep the lubrication at a safe level. The ideal viscosity is 20-40 cst. Additional technical data Noise levels and bearing life calculations available on request. Please contact Sunfab! Useful formulaes Required flow rate Speed Torque Power Q = n = M = P = D x n 1000 x η v Q x 1000 x η v D D x p x η hm 6.3 Q x p x η t 60 litres min. RPM Nm kw D n P Q η v η hm η t M p = displacement, cm 3 revolution = speed, revolution min = power, kw = flow rate, litres min = volumetric efficiency = hydraulic-mechanical efficiency = overall efficiency = η v x η hm = torque, Nm = pressure difference between the hydraulic motor inlet and outlet, MPa 3204GB1502 1.1 - Printed: 30/11/2018 03:46:26 - Page 12/13 11 (12)

WARNING When the motor is in use: 1. Do not touch the pressure pipe 2. Beware of rotating parts 3. The motor and pipes can reach high temperatures Sunfab reserves the right to make changes in design and dimensions without notice. Printing and typesetting errors reserved. Copyright 2015 Sunfab Hydraulics AB. All Rights Reserved. GB - Printed: 30/11/2018 03:46:26 - Page 13/13