Change-Over Diesel PreCare HDPD up to 1800 l/h

Similar documents
Diesel PreCare HDP up to 1800 l/h

Change-Over Pressure Filter DFDK

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

EN / Modern Duplex Filters for Large Engines

Pressure Filter DF...K P, DF...M P, Flange Mounted

Return Line Filter RFM with 4-Hole Mounting

Plastic Tank Systems Standard models

Return Line Filter RF

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Return line and Suction Boost Filter RKM

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Return Line Filter RFM with 4-Hole Mounting

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Change-Over Inline Filter AFLD to API 614

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Change-Over Inline Filter RFLD Welded Version

Components and Systems for the Automotive Industry

Preferred Range: Filters to DIN Standard

Return Line Filter RFM with 2-Hole Mounting

TRUCKTEC T R U C K T E C

Change-Over Inline Filter RFLD Weld Version

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

HYDAC Quality for Pall Housings: Ecomicron 2-fit.

Breathers and Filler Breathers

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

3/2 Way Ball Valves KHB3K

Low Pressure Filters

Process Inline Filter Medium / High Pressure PFM / PFH

Mobile Filter Unit MFU-15

Feed Pumps VP / VPB / VPBM

Automatic back-flushing filter AutoFilt RF4

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Safety Equipment for Hydraulic Accumulators

Automatic Back-Flushing Filter AutoFilt RF9.

Plate Heat Exchangers

Innovative Element Technology for installation in HYDAC filters E / Quick Selection -

TankConditioner TC. TC visual/ electrical 1.5 GENERAL TECHNICAL SPECIFICATIONS. (10 deep) seals. For further information, please see Point 3.

Metal Bellows Accumulators for Heavy Diesel Engines

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

HYDAC LowViscosity Housings: Highest diesel quality on the whole transport route

Isolator Sandwich Plate

3- and 4-Way Ball Valves KH3/KH4

Piston Accumulators High pressure

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Piston Accumulators High pressure

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Electrohydraulic Drive System EHC-A

Multi-Function Ergonomics, Ergonomics and Knobs Handles

Safety Equipment for Hydraulic Accumulators

Process screen basket filter PRFS

Conditioning Module Reservoir Extraction CM-RE

LowViscosity Housing- Coalescer Diesel LVH-CD

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Filters. HF4R Series. Service and Parts. Index. Inlet. Outlet. ø7 (ø177.8mm) Bolt Circle ø6.25 (ø158.8mm) ø0.44 (ø11.1mm) 4 Places Equally spaced

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Sectional Directional Control Valve RS 220

Return Line Filter RF

HYDAC KineSys The energy-efficient drive system

Process Inline Filter PLF1

Backflushing Filter AutoFilt RF4

Process Inline Filter Protective filter PLF2-9HF

Spare Parts List Mobile Spin-On Filters MF/MFD. Flow rates up to 300 l/min Pressure range up to 8 bar Material: Aluminium / Sheet Steel

Price List 2018 In-House Repairs and Calibrations

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

RFN Series Service and Parts

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

Filters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/

Court of Registration: Saarbrücken, HRB Haering

Monoblock Directional Control Valve RM 230

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

HYDAC Fluidtechnik: Industrial Valves FLOW CNTROL VALVE COMPENSATED PRESSURE VP-SR X.XXX.0/01.09 E / D E /08.

Sectional Directional Control Valve RSQ 240

Oil Filter Module Pi 8300

HYDAC (Three-Phase Current) Compact Power Units CO1

MultiRheo Filter MRF 1/2/3/4/5/6/7

Selector Valve RV 713

HYDAC DC Compact Power Units DC1

Off-line Oil Filter Module Pi 8400

Oil Filter Module Pi 8300

MultiRheo Filter MRF 1/2/3/4/5/6/7

Filters. HF3P Series Places 60 b c x d DP 4 Places Flange

2/2 way Coaxial valve CXRM compact, pilot operated Modular design

Spare Parts List Filter NFD Change-Over Version

Leadership in Filtration. MANN+HUMMEL Fuel Filters

HYDAC KineSys Motion Control Systems

Suction Filter Pi 200

Suction Filters S8-455 SE56-560

Spare Parts List Return Line Filter RFM with 4-hole attachment

RFL Cast Series Service and Parts

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

Air Cooler Mobile OK-ELD 0-6 with DC motor

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

LowViscosity Housing Filter LVH-F

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Transcription:

Change-Over Diesel PreCare HDPD up to 1800 l/h Manual HDPD 340 HDPD 600 HDPD 1200 HDPD 1800 Fully automatic HDPD 600 HDPD 1200 HDPD 1800 1. TECHNICAL SPECIFICATIONS 1.1 FILTER The change-over Diesel PreCare is a modern system for diesel prefiltration which protects vehicle manufacturers and operators against breakdowns, downtimes and expensive service calls. The change-over "Diesel PreCare" filters consist of a module with multiple filter housings. They are connected by a ball change-over valve with singlelever operation. The HYDAC solution is available in two versions: Manual water discharge (BestCost) - the conventional, operator-dependent solution Fully automatic discharge Plug&Play (HighTech) - the innovative solution for fully automatic dewatering, independent of the operator, even during suction-side operation. 1.2 FILTER ELEMENTS HYDAC filter elements Dieselmicron are validated and their quality is constantly monitored according to the following standards: ISO CD 16332 ISO 19438 1.3 FILTER SPECIFICATIONS Operating pressure Flow rate Mounting thread 1.4 SPECIAL MODELS AND ACCESSORIES Water sensor (present as standard on HDPD "HighTech") Fuel pre-heater Clogging indicator (only HDPD "HighTech") With integrated hand pump or electric pump (only HDPD 600 BestCost and multiple modules) Others on request! 1.5 SPARE PARTS See Original Spare Parts List 1.6 CERTIFICATES AND APPROVALS On request 1.7 COMPATIBILITY WITH FUELS Diesel, biodiesel (B0-B100), (non-conductive) Others on request. < 1 bar absolute BestCost: up to 1800 l/h HighTech: up to 1800 l/h BestCost: M22x1.5; M27x1.5 HighTech: G ¾ (others in request) Temperature range BestCost: -40 C to +90 C HighTech: -20 C to +90 C (extended temperature range on request) Nominal voltage 24 V DC (optional 12 V) Rated output for fuel pre-heater up to 300 W Water separation efficiency >95% in accordance with ISO CD 16332 1.8 MAINTENANCE INSTRUCTIONS Only for suction-side operation Filter housings must be earthed. When using electrical clogging indicators, the electrical power supply to the system must be switched off before removing the clogging indicator connector. Due to the likelihood of freezing, there must be no restriction in the drain line. This is to compensate for the expansion. Symbol for hydraulic systems Return of surplus fuel to lubricate / cool the CR pump Pre-filter H2O Charge pump Main filter Fuel tank Automatic water discharge Common Rail 1

2. MODEL CODE (also order example) 2.1 COMPLETE FILTER "BESTCOST" (MANUAL DESIGN) HDPD KF1 340 BC1 10 W 1.X /-AS1 Filter type HDPD KF1 Dieselmicron HDPD: 340 (=left side 1x HDP 340, right side 1x HDP 340) 600 (=left side 1x HDP 600, right side 1x HDP 600) 1200 (=left side 2x HDP 600, right side 2x HDP 600) 1800 (=left side 3x HDP 600, right side 3x HDP 600) BC1 10 µm standard, fully synthetic 30 µm fully synthetic 7 µm high performance mixed media (glass/synthetic) Type of clogging indicator W no connection for a clogging indicator Type code 1 Modification number X the latest version is always supplied ASx with integrated water sensor Hx with integrated fuel pre-heater PHx with integrated hand pump (only HDPD 600 BC1) PEx with integrated electric pump (only HDPD 600 BC1) Kxxx customer-specific 2.2 SPARE ELEMENT "BESTCOST" 0340 BC1 010 KF1 /-Kxxx 0340, 0600 BC1 010 standard, fully synthetic 030 fully synthetic 007 high performance mixed media (glass/synthetic) KF1 Dieselmicron Kxxx (for descriptions, see point 2.1) 2

2.3 COMPLETE FILTER "HIGHTECH" (FULLY AUTOMATIC DESIGN) HDPD KF1 600 HT1 10 UED 1.X /-AS1 Filter type HDPD KF1 Dieselmicron HDPD: 600 (=left side 1x HDP 600, right side 1x HDP 600) 600 (=left side 1x HDP 600, right side 1x HDP 600) 1200 (=left side 2x HDP 600, right side 2x HDP 600) 1800 (=left side 3x HDP 600, right side 3x HDP 600) HT1 10 µm standard, fully synthetic 30 µm fully synthetic 7 µm high performance mixed media (glass/synthetic) Type of clogging indicator A Steel screw plug in indicator port UED Vacuum gauge Type code 1 Modification number X the latest version is always supplied ASx standard: with integrated water sensor Hx with integrated fuel pre-heater Kxxx customer-specific 2.4 SPARE ELEMENT "HIGHTECH" 600 HT1 010 KF1 /-Kxxx 0600 HT1 010 standard, fully synthetic 030 fully synthetic 007 high performance mixed media (glass/synthetic) KF1 Dieselmicron Kxxx (for descriptions, see point 2.3) 2.5 REPLACEMENT CLOGGING INDICATOR VMF 1 UED. X Type VMF Thread G 1/8 Pressure setting 1 standard -1 to 0 bar (others on request) Type of clogging indicator (see Point 2.3) Modification number X the latest version is always supplied Other standard models on request 3

3. SPECIAL MODELS Further variations of our "standard" change-over filters HDPD are possible: 3.1. DIFFERENT NUMBER OF FILTERS ON EACH SIDE Order example: HDPD KF1 600/1200 BC1 10 W 1.0 /-PH1 3.2. DIFFERENT EVOLUTION STAGES ON EACH SIDE Order example: HDPD KF1 600/340 HT1/BC1 10 W 1.0 /-AS1 Please contact HYDAC Head Office or your local area office for further advice. 4

4. DIMENSIONS 4.1. MANUAL DESIGN HDPD 340 "BestCost" 172 325 424 Other sizes 178 (HDPD BC 1200/1800) 157 (HDPD BC 600) 416 1247 (HDPD BC 1800) 854 (HDPD BC 1200) 429 (HDPD BC 600) HDPD KF1 600 BC1... HDPD KF1 1200 BC1... HDPD 340 BC 600 BC 1200 BC 1800 BC Weight incl. element [kg] 9.0 11.0 19.6 30.0 HDPD KF1 1800 BC1... 5

4.2. FULLY AUTOMATIC DESIGN HDPD "HighTech" 1410 (HDPD HT 1800) 181 (HDPD HT 1200 / 1800) 163 (HDPD HT 600) 990 (HDPD HT 1200) 460 (HDPD HT 600) 394 HDPD 600 HT 1200 HT 1800 HT Weight incl. element [kg] 20.0 40.0 60.0 NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. HYDAC Filtertechnik GmbH Industriegebiet D-66280 Sulzbach/Saar Tel.: 0 68 97 / 509-01 Fax: 0 68 97 / 509-300 Internet: www.hydac.com E-Mail: filter@hydac.com 6