VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

Similar documents
VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

TECHNICAL SPECIFICATIONS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

1 / Genset general description

1 / Genset general description

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

1 / Genset general description

GE.VO.360/325.SS+0_all

GE.PK.022/020.SS+0_all

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Standby Amper VOLTAGE

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Technical specification

WPS20/S EP Series. Features:

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

WPS350/S EP Series. Features:

GMR - 67P 67P 09/05/2016 GMR - 067P

70 KW / 90 KVA POWERED by

50 Hz kva & PORTABLE RANGE. Rev. 0 07/05/2015

WPS100/S EP Series. Features:

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

16 KW / 20 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Standby Amper VOLTAGE

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

30 KW / 40 KVA POWERED by

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

WPS60/S EP Series. Features:

Standby Amper VOLTAGE

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

60 KW / 75 KVA POWERED by

57 KW / 71 KVA POWERED by

500 KW / 625 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

WPS150/S EP Series. Features:

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

WPS250/S EP Series. Features:

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Generating Rates. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

TPD2250H6.3 TECHNICAL DATA

130 KW / 165 KVA POWERED by

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

45 KW / 55 KVA POWERED by

28 KW / 28 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Generating Rates SERVICE PRP STANDBY. HR RANGE Soundproofed rental Powered by YANMAR

18 KW / 18 KVA POWERED by

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Transcription:

TECHNICAL SPECIFICATIONS Model: IVRN-115 Image for guidance purposes. (400 / 230 V) ENGINE ALTERNATOR MAKE VOLVO MODEL MODEL TAD551GE (IIIA) MECC-ALTE ECP 34-2S / 4 CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) STAND-BY POWER: (LTP Limited Time Power norma ISO 8528-1) 105 kva 115 kva Amperes in the different voltages: VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/240 50 3 0,8 102,6/82,1 113,0/90,4 157,32 400/230 50 3 0,8 102,6/82,1 113,0/90,4 163,22 380/220 50 3 0,8 102,6/82,1 113,0/90,4 171,81 240/139 50 3 0,8 102,6/82,1 113,0/90,4 272,03 230/133 50 3 0,8 102,6/82,1 113,0/90,4 283,85 220/127 50 3 0,8 102,6/82,1 113,0/90,4 296,76

ENGINE CHARACTERISTICS MAKE VOLVO GENERAL DATA Power PRP (kwm) Power LTP (kwm) No. cylinders Cylinder capacity (L) Diameter per stroke (mm) Compression ratio Cooling system Injection Suction Series regulator Fly wheel coupling MODEL TAD551GE (IIIA) 89.00 98.00 4 4.76 108 x 130 18.00 LIQUID DIRECT TURBO-INTERC. ELECTRONIC 3-11.5" Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) 21.00 0.11 1.30 Ventilation system Air cooling flow (m3/h) Combustion air flow (m3/h) Max. back pressure for fan (mbar) 5040 450.00 3 Exhaust system Exhaust gas flow (m3/h) Exhaust back pressure (mbar) Temp. exhaust gases (ºC)) 1248 70 530 Electrical system VDC (V) Battery (Ah) Engine start-up (kw) 24 120 5

ALTERNATOR CHARACTERISTICS MODEL MECC-ALTE ECP 34-2S / 4 (400 / 230 V) GENERAL DATA Power PRP (kva) Power LTP (kva) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X d (%) X Degree of protection 105 115.50 92.50 92.20 4 DSR 12 H 230 17.60 7.40 IP21 GENERATOR SET CONSUMPTION % POWER USED LITRES/HOUR 50% 15.20 75% 21.70 100% 26.10 DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT AND NOISE DIMENSIONS (MM) LENGTH WIDTH HEIGHT 2990 1140 1900 FUEL TANK (LITRES) WEIGHT (KG) 480.00 2170.00 NOISE LEVEL (db (A)) 69dB(A)@7m

INMESOL GENERATOR SET GENERAL DESCRIPTION The INMESOL generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. REGULATIONS The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS).

RE RENTAL RANGE / SCOPE OF SUPPLY Engine/alternator assembly, coupled and installed on a heavy electric wilded steel profile base frame through antivibration pad, then treated with rust removing products for zink layer application and Polyester (QUALICOAT) painting, special treatment for external and corresive environment.. Soundproof canopy treated with rust removing products for zink layer application and Polyester (QUALICOAT) painting, special treatment for external and corresive environment. Then lined with rock wool material of high density. Liquid cooled engine with integraed mechanical radiator and blower fan. Integrated exhaust residential silencer of -35 db (A) antenuation, with rain cap protection. Lifting hook crane. Fork lift pockets for easy lifting from the bottom. Hook for towing. Radiator water filling cover register. Easy acces to radiator cleaning, and replacement. Integrated metalic fuel tank of 24 hours autonomy with liquid leakage protection. Large fuel tank register for cleaning. Fuel draining plug. Internal fuel filler cap with security locable key. Kit of 3-way valves for external fuel tank connection (optional). Fast fuel plug connection between external and internal fuel tanks. (Optional). Protection of heat, mobile, and live comoponents. Manual oil sump pump. Baseframe prepared to be mounted on a trailer. External emergency stop push button. Engine starting battery maintenance free complete with wires connection, terminal protection and on-off switch. Alternator battery charger with earth plug. Self excited and auto regulated alternator. Manual control panel with a mircroprocessor for control, protection and generating set reading parameters as voltage, amperage, working hours, etc. Digital manual/automatic control panel (optional). Circuit breaker, and differential for protection. Prepared for earth stud installation (earth stud not included). Voltage and frequency change selector (optional). Electrical power socket kit (optional). Soundrpoof canopy auxiliary internal lighting (optional). Standard electronic speed governor on engines from 220 kva (LTP) and up. Vertical outlet for hot air

RE RENTAL RANGE / OPTIONS Engine preheating system. Battery charger. Automatic/manual fuel trasnfer pump. Total plus alternator protection. Diferent colour. External linkbox for armound cables.

DSE 6010 MKII MANUAL CONTROL PANEL DSE 6010 MKII MANUAL CONTROL PANEL MANUAL CONTROL, PROTECTION AND DISTRIBUTION panel, assembled on the generator set in metal cabinet with a DSE 6010 MKII engine protection unit. Image for guidance purposes. It has the following: 1 EMERGENCY STOP PUSHBUTTON. 2 PROTECTIONS: Magnetothermal Protection. Differential Protection Protection fuses for control module

DSE 6010 MKII MANUAL CONTROL PANEL 3 DSE 6010 MKII PROTECCION CONTROL MODULE. It has a digital LCD screen, which provides easy reading of the information regarding the ENGINE, ALTERNATOR and CHARGING. READINGS that can be made: ENGINE: Coolant temperature Oil pressure Turning speed (rpm) Fuel level Battery voltage Battery alternator voltage Operating hours Number of start-ups ALTERNATOR AND CHARGE: Voltages between phases and between phases and neutral. Frequency Intensities CONTROL of the set: START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL. Protection of the engine and alternator, with the ALARMS activated: ENGINE: Low oil pressure High coolant temperature Low and High battery Voltage. Failure of the alternator to charge batteries Low fuel level.. ALTERNATOR: Low and High Voltage Low and High Frequencya Overload due to Intensity (A)

DSE 6010 MKII MANUAL CONTROL PANEL OTHER CHARACTERISTICS: The real-time clock records the last 50 events.s. Configurable inputs and outputs. Configurable alarms and timers. USB connectivity Fully configurable via software and PC. Communication via USB cable for remote control Programmable clock with multiple maintenance events which can be configured for optimal motor functioning. Weekly and/or monthly programming for up to 8 startups and shutdowns per week. ALTERNATIVE CONFIGURATIONS, which open up the working possibilities.

DSE 6010 MKII MANUAL CONTROL PANEL 4 OPTIONAL: AUTOMATIC PANEL FOR MANUAL GENERATOR: ATS DSE 334 This panel provides the manual control generator with a reserve operation from the Mains, as the ATS sends the command to start and stop the generator, when it detects a supply failure and when the Mains is restored Cubicle composed of the electronic control module which is detecting a mains failure and of 2 contactors mechanically and electrically interlocked or a motorized switch controlled by the above electronic controller who are realizing the change of supply from the GEN SET or the MAINS to the load.