VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

Similar documents
TECHNICAL SPECIFICATIONS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

1 / Genset general description

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

1 / Genset general description

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Standby Amper VOLTAGE

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMR - 67P 67P 09/05/2016 GMR - 067P

GE.PK.022/020.SS+0_all

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GE.VO.360/325.SS+0_all

Technical specification

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Standby Amper VOLTAGE

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Standby Amper VOLTAGE

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

P6000s 230V 50Hz #CONN #DPP

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

S V50HZ #AVR #CONN #DPP

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

LWALR LIQUID COOLED LONG RUNNING GENSETS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

WPS20/S EP Series. Features:

The enginewithintegrated water cooling

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

P V 50HZ #CONN #DPP

POWER ENGINEERING KVA 50 HZ rpm

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS350/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

THE COMPLETE PETROL PACKAGE

SIVASA Doosan Series. SD250 Technical Data

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

TPD2250H6.3 TECHNICAL DATA

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

MODEL GBW15-22 Yanmar

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

WPS100/S EP Series. Features:

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Standby Amper VOLTAGE

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

Transcription:

TECHNICAL SPECIFICATIONS Model: II-044 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL F32SM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 40 kva ALTERNATOR MODEL MECC-ALTE ECP 32-3S / 4 STAND-BY POWER: (LTP Limited Time Power norma ISO 8528-1) 44 kva Amperes in the different voltages: VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/240 50 3 0,8 41,8/33,4 46,0/36,8 64,02 400/230 50 3 0,8 41,8/33,4 46,0/36,8 66,42 380/220 50 3 0,8 41,8/33,4 46,0/36,8 69,91 240/139 50 3 0,8 41,8/33,4 46,0/36,8 110,7 230/133 50 3 0,8 41,8/33,4 46,0/36,8 115,51 220/127 50 3 0,8 41,8/33,4 46,0/36,8 120,76

ENGINE CHARACTERISTICS MAKE FPT GENERAL DATA MODEL F32SM1A Power PRP (kwm) Power LTP (kwm) No. cylinders Cylinder capacity (L) Diameter per stroke (mm) Compression ratio Cooling system Injection Suction Series regulator Fly wheel coupling 37.70 41.50 4 3.20 99 x 104 17.10 LIQUID DIRECT TURBO MECHANICAL 3-11,5" Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) 10.50 0.10 0.60 Ventilation system Air cooling flow (m3/h) Combustion air flow (m3/h) Max. back pressure for fan (mbar) 5760-20 Exhaust system Exhaust gas flow (m3/h) Exhaust back pressure (mbar) Temp. exhaust gases (ºC)) 491 50 593 Electrical system VDC (V) Battery (Ah) Engine start-up (kw) 12 90 3 Teléfono: +34 968 380 Planet 129 Trading Phone: and Transportation +34 968 380 879 W L L Street No:4 / Gate Fax: No: +34 117 968 380 / Building 504 No:235 / Fax: Industrial +34 968 Area 380 400 / PO Box: 8359 Doha / Qatar Tel: 974 E-mail: 4498 sales@inmesol.com 7849

ALTERNATOR CHARACTERISTICS MODEL MECC-ALTE ECP 32-3S / 4 (400 / 230 V) GENERAL DATA Power PRP (kva) Power LTP (kva) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X d (%) X Degree of protection 42.50 46.75 89.10 88.60 4 DSR 12 H 190 14.30 10 IP21 GENERATOR SET CONSUMPTION % POWER USED LITRES/HOUR 50% 5.60 75% 8.50 100% - DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT AND NOISE DIMENSIONS (MM) LENGTH WIDTH HEIGHT 2500 1100 1455 FUEL TANK (LITRES) WEIGHT (KG) 85.00 1230.00 NOISE LEVEL (db (A)) 60 @ 7 m

INMESOL GENERATOR SET GENERAL DESCRIPTION The INMESOL generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. REGULATIONS The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS).

IN INDUSTRIAL RANGE / SCOPE OF SUPPLY Engine/alternator monobloc directly connected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint. Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint. Fuel tank integrated in the base frame provided with fuel level jauge and fuel connections to the engine. Engine with mechanical engine driven pusher fan. Industrial silencer with -15 db(a) noise reduction and exhaust outlet tube. Residencial silencer with -35 db(a) noise reduction with exhaust tube and protection cap. Electric control cubicle with control module including protection and reading of electrical meassures engine instrumentation fuel level and engine running hours, etc. Termal and magnetic circuit breaker and termal and magnetic circuit breaker and earth fault relay. Battery charge alternator. Starter battery complete with cables to the engine and pole protection. Installation prepared for earthing spike (spike not included). Security protection for heat and moving parts as well as live electrical components. External emergency stop push button. Manual engine oil extraction pump. Self excited and auto regulated alternator. Integrated lifting hook for single point lifting with crane, gensets up to 450 kva (Except in swing-out cover model) 4 Lifting points for gen sets from 450 kva and bigger. Preparate for extended fuel tank, fully bomded for leakage protection. Base frame is prepared for trailer kit installation. Standard electronic speed governor on engines from 220 kva (LTP) and up. Horizontal outlet for hot air Street No:4 / Gate Fax: No: +34 117968 / Building 380 504 No:235 / Industrial Fax: +34 Area 968 / PO 380 Box: 400 8359

DSE 3110 MANUAL CONTROL PANEL DSE 3110 MANUAL CONTROL PANEL MANUAL CONTROL, PROTECTION AND DISTRIBUTION panel, assembled on the generator set in metal cabinet with a DSE 3110 engine protection unit. It has the following: Image for guidance purposes. 1 STARTER SWITCH 2 EMERGENCY STOP PUSHBUTTON 3 MEASURING INSTRUMENTS: 3 Analogue Ammeters. 1 Analogue Voltmeter with a separated phases selector. Fuel Level Indicator Digital Reading of Hz and Functioning Hours Counting (DSE 3110)

DSE 3110 MANUAL CONTROL PANEL 4 SET CONTROL AND ENGINE PROTECTION: DSE 3110, allows: START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL Digital readings of the operating hours and the Frequency Controls the main characteristics of the engine, causing an alarm or stopping the machine: 1. Low and High Voltage (STOP) 2. Low and High Frequency and Speed (STOP) 3. Low Oil Pressure and High Coolant Temperature (STOP) 4. Failure of the Alternator Battery-Charger (ALARM) 5. Low fuel level (ALARM) 5 PROTECTIONS: Magnetothermal Protections Earth Leak Protection Protection fuses for control module

DSE 3110 MANUAL CONTROL PANEL For OPEN sets - Three-phase generators (single phase by request): SET POWER CONT. POW. MAGNETO. PROTECTION (A) EARTH LEAK PROTECTION DISTRIBUTION 10 kva 4P, 16A (B) Mod. 16A, 300 ma 1 B. CEE 3P+N+T 16A 13 kva 4P, 20A (B) Mod. 25 A, 300 ma 1 B. CEE 3P+N+T 32A 15 kva 4P, 25A (B) Mod. 25 A, 300 ma 1 B. CEE 3P+N+T 32A 20 kva 4P, 32 A (B) 1 B. CEE 3P+N+T 32 A Mod. 32 A, 300 ma 1 B. CEE 2P+T 16 A 4P, 50 A (B) 1 B. CEE 3P+N+T 63 A 30 kva Mod. 63 A, 300 ma 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 63 A (B) 1 B. CEE 3P+N+T 63 A 40 kva Mod. 63 A, 300 ma 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 80 A (B) 1 B. CEE 3P+N+T 125 A 50 kva 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 100 A (B) 1 B. CEE 3P+N+T 125 A 60 kva 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 125 A (B) 1 B.CEE 3P+N+T 16 A 75-80 kva 1 B.SCHUKO 2P+T 16 A 3P, 160 A (B) 1 B. CEE 3P+N+T 16A 100 kva 1 B. SCHUKO 2P+T 16 A 3P, 250 A (B) 1 B. CEE 3P+N+T 16A 125-150 kva 1 B. SCHUKO 2P+T 16 A 3P, 400 A (B) 1 B. CEE 3P+N+T 16A 200-275 kva 1 B. SCHUKO 2P+T 16 A 3P, 630 A (B) 1 B. CEE 3P+N+T 16A 300-400 kva 1 B. SCHUKO 2P+T 16 A 3P, 800 A (B) 1 B. CEE 3P+N+T 16A 450 kva 1 B. SCHUKO 2P+T 16 A VOLVO 430 kva DEUTZ 3P, 800 A (B) 450-500 kva 3P, 630 A (B) 570-650 kva 3P, 1000 A (B)

DSE 3110 MANUAL CONTROL PANEL 6 OPTIONAL: AUTOMATIC PANEL FOR MANUAL GENERATOR: ATS DSE 334 This panel provides the manual control generator with a reserve operation from the Mains, as the ATS sends the command to start and stop the generator, when it detects a supply failure and when the Mains is restored Cubicle composed of the electronic control module which is detecting a mains failure and of 2 contactors mechanically and electrically interlocked or a motorized switch controlled by the above electronic controller who are realizing the change of supply from the GEN SET or the MAINS to the load.