Developing Performance Based Generator Set and System Specifications

Similar documents
Diesel Generators in the Data Center: When to Go Big

UL 1008 ATS Withstand and Close On Ratings

Understanding ISO 8528 Generator Set Ratings

NFPA 110 Overview for Generator Set Emergency Power Systems This material is based on NFPA

Emissions Requirements for Compression Ignition Engines in EPA Non-Emergency Operation

JOB LOSSES BY STATE, State Industry US total AK AL AR AZ CA CO CT Agriculture, forestry, fisheries -15, ,

FY 2002 AWA INSPECTIONS

UPDATE OF THE SURVEY OF SULFUR LEVELS IN COMMERCIAL JET FUEL. Final Report. November 2012

National Routing Number Administration p-ani Activity and Projected Exhaust Report

Reducing deaths, injuries, and loss from motor vehicle crashes

Electrical & Power Study May Sponsored by:

Five Star Dealer INTERNATIONAL.

Choose a Sunroof with Style STRUCTURE PLUS. Webasto Aftermarket Sunroofs OE Quality. Featuring

BAF Overview. Barry P. Carr Northeast Regional Sales Manager November 2012

U.S. Heat Pump Water Heater Market Transformation: Where We ve Been and Where to Go Next

Five Star Dealer USA.

Finding List by Question by State *

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

The Economic Downturn Lessons on the Correlation between Economic Growth and Energy

Diesel Generator Set S3.8 Series Engine

Thru-The-Wall TTWC-R Series Condensing Unit Catalog 1-1/2 To 2-1/2 Ton Capacity

Diesel generator set QSK78 series engine

Optimizing Emergency Power Systems for Health Care Applications

Diesel generator set QSX15 series engine

PlugShare Quarterly 2015-Q3 Census, US Electric Vehicle Infrastructure Exhibits

Diesel generator set QSX15 series engine

CustomerServicesDivision

Diesel generator set QSK23 series engine

Traffic Safety Facts 1995

Effects of all-offender alcohol ignition interlock laws on recidivism and alcohol-related crashes

Owner letters will be mailed based upon part number and production date, starting with earlier production vehicles.

EP 724 US RAIL SERVICE ISSUES DATA COLLECTION

Diesel generator set QSK23 series engine

Executive Summary: U.S. Residential Solar Economic Outlook :

Policy considerations for driving automation technology

An Overview of Solar Energy and Opportunities for Growth in the Midwest and Kansas

Semiannual Report Of UST Performance Measures End Of Fiscal Year 2018 (October 1, 2017 September 30, 2018)

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

U.S. PRODUCTION GROWTH

Highway Safety Countermeasures

Diesel generator set QSK78 series engine

Diesel generator set QSK60 series engine

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Effects of all-offender alcohol ignition interlock laws on recidivism and alcohol-related crashes

Diesel generator set QSB7 series engine

Weather Shield Thermal Performance Criteria

NEC REQUIREMENTS FOR GENERATORS

TOOLING & WORKHOLDING. Executive Summary.

2013 Migration Patterns traffic flow by state/province

Traffic Safety Facts 2002

North Carolina. Joel Sheltrown VP of Governmental Affairs Elio Motors, Inc

Wyoming electricity use is growing

Diesel Generator Set Model DFJD 60 Hz

IIHS activities on alcohol-impaired driving

University of Houston Master Construction Specifications Insert Project Name

Diesel generator set QSK50 series engine

Diesel generator set QST30 series engine

2016 Migration Patterns traffic flow by state/province

Diesel generator set QSK60 series engine

, NAS!?r-s~~if.{" WOQi2AN PIGS: FINAt:. EST'IHATES (STATISTICAL,,,", BULLETIN.) NATIONAL ' AGRICULTURAL STATISTICS SERVICE,, ':-'-"'-'-,,

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Spark-Ignited Generator Set Model GGKD 60 Hz

Paralleling Equipment

Charles Hernick Director of Policy and Advocacy

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Diesel generator set 4BT3.3 series engine

RhodeWorks Initiative

Up to Spec! American Coalition for Ethanol Annual Conference, August 17, Kristy Moore KMoore Consulting LLC

Diesel Generator Set Model DFHB 60 Hz

Alaska (AK) Passenger vehicles, motorcycles 1959 and newer require a title ATV s, boats and snowmobiles do not require a title

Diesel generator set QSK60 series engine

GOVERNMENT RELATIONS BULLETIN

Diesel generator set QSK95 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Spark-ignited generator set

Diesel generator set 6BT5.9 series engine

EPA Emissions Standards for Switch and Line-Haul Locomotives

Solar Power. Michael Arnold, LEED AP. ACI-NA Environmental Committee Meetings June 27, 2011

Spark-Ignited Generator Set Model GGKC 60 Hz

Rental Power 800 kw. Specification sheet. Description. Features. Options

Tier4 certified diesel generator set QSK50 series engine

Diesel Generator set QSK95 series engine

Diesel generator set QSK60 series engine

Spark-ignited generator set

NISSAN GROUP. More than 34 Years of Manufacturing in America IS INVESTING IN AMERICA FUTURE IN AMERICA JOBS IN AMERICA SOURCED IN AMERICA

Diesel Generator set QSK95 series engine

Green Bus Technology Plan

Spark-ignited generator set

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Model DFHD 60 Hz EPA Emissions

Gaseous Fuel Generator Set Model GFDA

CSA State of the Union

EPA REGULATORY UPDATE PEI Convention at the NACS Show October 8, 2018 Las Vegas, NV

Richard Carrier Trucking, Inc. P.O. Box 718, Skowhegan, ME

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

CHART A Interstate ICS Rates

Net Metering in the world

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel generator set QSL9-G7 series engine

Transcription:

PowerHour webinar series for consulting engineers Experts you trust. Excellence you count on. Developing Performance Based Generator Set and System Specifications Thursday May 12 1:00 CDT / 2:00 EDT (1PDH issued by Cummins)

Welcome! PowerHour is designed to help our engineer partners to Keep up to date on products, technology, and codes and standards development Interact with Cummins experts and gain access to ongoing technical support Participate at your convenience, live or on-demand Earn PDH Technical tips: Audio is available through teleconference, or your computer (don t forget to unmute) You are in listen only mode throughout the event Use the WebEx Q&A Panel to submit questions, comments, and feedback throughout the event. We will provide sufficient Q&A time after presentation If you lose audio, get disconnected, or experience a poor connection, please disconnect and reconnect Report technical issues using the WebEx Q&A Panel, or email powergenchannel@cummins.com

Meet your panelists Cummins presenters: Mike Sanford Group Leader, North America and Caribbean Application Engineering Hassan Obeid Technical Specialist, Application Engineering Cummins facilitator: Tom Bakritzes, Global Sales Training Manager Your local Cummins contacts: IL: John Kilinskis (john.kilinskis@cummins.com), Cummins Sales and Service, Central region TX: Scott Thomas (m.scott.thomas@cummins.com), Cummins Sales and Service, Gulf region IN, KY, OH, TN, WV: Tom Stadulis (thomas.stadulis@cummins.com), Cummins Sales and Service, East region For other regions, find your local distributors at http://power.cummins.com/sales-service-locator, or email: powergenchannel@cummins.com 3

Course Objectives Participants will be able to: Recognize performance-based requirements for generator set, transfer switch and switchgear specifications. Identify common specification pitfalls and provide performancebased alternatives. Recognize current technology trends that impact the power generation industry and learn how they can be applied to existing specifications. Discuss the benefits of specification generation tools and how they can improve efficiency by specifying competitive and thorough system requirements.

What is a Performance-based Spec? Driven by a functional requirement Why is it needed? Incorporates technology relevant in the current market Requires an understanding of underlying principles Improves system efficiency and reliability by optimizing equipment for specific applications Inclusive of functional equivalents

Generator Set Specification Items

Diesel Engine Requirement Each engine shall be of the full diesel compression ignition, liquid cooled type, 16 cylinder, four cycle, 1800 rpm and shall utilize No.2 diesel fuel. The engine shall be turbo-charged, after-cooled and equipped with crosshead malleable iron pistons, replaceable cylinder liners, counter balanced forged steel crankshaft, forged steel connecting rods, replaceable main and connecting rod bearings

Diesel Engine Requirement Specificity of content may limit the design choices for product Requiring detail on such a section may distract from key performance drivers By including this text in the spec, if a new technology is released, it may limit the potential of adopting a better technology Suggest including the functional requirements (fuel type, cooling type, etc.) Fuel: ASTM D975 #2 Diesel Fuel

Fuel Filtration The genset shall be provided with heavy duty, high capacity fuel pre-filter/water separators as manufactured by Brand X. Filters shall be Model Y, and provide two stages of filtration: 30 micron primary and 7 micron secondary.

Fuel Filtration Specifying a brand of filters limits product options (a different brand may provide something better) The filter micron requirement should be removed, filtration requirements are not common across all engine manufacturers. Fuel oil filters shall be provided per engine manufacturer s requirements. Filter and Strainer: Provided by the engine manufacturer of record to provide adequate filtration for the prime mover to be used.

Sound Performance Housing should provide sound reduction capabilities up to Critical Grade Silencing. Exhaust silencer(s) shall be critical grade. Does not specify overall sound pressure level at a given distance (property line) May not comply with local noise ordinances Sound pressure level measured at the property line (23 feet from the generator set), shall not exceed 85 db(a).

Sound Performance 87 db(a)

Fuel Coolers Engine generator shall be equipped with a fuel oil cooler. Fuel return temperature must not exceed 38 C. Fuel oil coolers are application specific Maintaining the returned fuel temperature at an excessively low value may not be achievable A fuel oil cooler shall be provided per the application as required by the engine manufacturer.

Design Calculations Calculations provided in the submittal package to include: Calculations of the engine and generator output power capability, including efficiency and parasitic load data. Calculations for the capacity of each day tank, including allowances for recirculated fuel, usable tank capacity, and duration of fuel supply.

Design Calculations Design calculations are considered proprietary data in most organizations Test data of actual output based on prototype and production units is a much more accurate and relevant piece of information Generator set manufacturer shall provide a certified summary of prototype-unit test report. Generator set manufacturer shall provide a list of factory tests to be performed on units prior to shipment. Generator set manufacturer shall provide a report of exhaust emissions and compliance statement certifying compliance with applicable regulations.

Turbocharger Loads Manufacturer shall submit turbocharger load bearing calculations for the proposed engine-generator set. The intent of this section is to determine the weight which the turbo can hold, not the electrical or mechanical load of the turbo impeller/housing.

Turbocharger Loads Turbocharger Exhaust Outlet Elbow / Flange

Turbocharger Loads Turbochargers are not built to hold weight, the flange is provided as a connection point only. Exhaust system shall be installed per engine manufacturer s requirements.

Transient Performance Expectations The engine-generator set shall respond to maximum step load changes such that the maximum voltage and frequency deviations from bandwidth are not exceeded. Max Step Load Increase 100 % of Service Load at 0.8 PF Maximum Voltage Deviation with Step Load Increase: 10 % of rated voltage Maximum Frequency Deviation with Step Load Increase: 5 % of rated frequency

Transient Performance Expectations 10% voltage dip on 100% step load of nameplate is virtually impossible 10% voltage dip on 100% step load of facility requirement is possible, but requires a significantly oversized genset For loads which are sensitive to voltage dip, apply them in steps and later in the loading sequence Not more than 20 percent variation for 50 percent step-load increase or decrease. Voltage shall recover and remain within the steadystate operating band within three seconds. On application of a 100% load step the generator set shall recover to stable voltage within 10 seconds.

ISO Transient Performance Engine-generator shall be capable of transient performance per ISO 8528 class G3. Common misinterpretation of this: ISO 8528 lists an acceptable voltage and frequency surge based on 100% load rejection and an acceptable voltage and frequency drop based on a calculated load percentage

O & M Manuals Six copies of the operation manual (approved prior to commencing onsite tests) in 8-1/2 by 11 inch binders, having a minimum of 3 rings from which material may readily be removed and replaced, including a separate section for each system or subsystem. Sections shall be separated by heavy plastic dividers with tabs which identify the material in the section. Drawings shall be folded blue lines, with the title block visible, and placed in 8-1/2 by 11 inch plastic pockets with reinforced holes. One full size reproducible mylar of each drawing shall accompany the booklets. Mylars shall be rolled and placed in a heavy cardboard tube with threaded caps on each end. The manual shall include: step-by-step procedures for system startup, operation, and shutdown; drawings, diagrams, and single-line schematics to illustrate and define the electrical, mechanical, and hydraulic systems together with their controls, alarms, and safety systems; the manufacturer's name, model number, and a description of equipment in the system. The instructions shall include procedures for interface and interaction with related systems to include automatic transfer switches, fire alarm/suppression systems, load shedding systems, uninterruptible power supplies. Each booklet shall include a CDROM containing an ASCII file of the procedures.

Common Specification References

Performance Spec Values Safety and protection: UL 2200 listed generator set, CSA, CE Emergency system usage: NFPA 110 Level 1, Type 10 Emissions Levels: Emergency Stationary, Stationary Non-emergency, or Non-road mobile Seismic IBC 2006, 2009, 2012, 2015 OSHPD Pre-certification

Performance Spec Values Transient Performance Class: ISO 8528 G2 or G3 (depending on load types) Voltage/Frequency dip requirements of potential facility loads Alternator specs: Temperature rise: 80 C, 105 C, 125 C depending on performance requirements Excitation type: PMG or AUX for non-linear loads or starting large motors (typically > 35 kw sets) Subtransient reactance: Sensitive loads (12%) Less sensitive loads (15%)

System/Switchgear Specifications

Control Circuit Board The ATS control logic shall be provided on multi-layer printed circuit boards How would a single-layer verses a multi-layer impact the performance of the ATS? Almost all circuit boards are multi-layered Possibly specify radio frequency emission compliance, surge withstand rating and operating temperature

Synchronizer and Load Control Include in the switchgear a Woodward MSLC and DSLC: All paralleling control components shall be compatible with each proposed generator manufacturer. Digital paralleling controls as part of the generator controller are not acceptable. What is the technical justification for not allowing the paralleling control to be part of the generator set? Relying on a master for paralleling introduces a single point of failure

Synchronizer and Load Control Provide a paralleling control panel for each generator set in the emergency/standby power system. Each paralleling control shall be independent and autonomous, requiring no interaction with other controls for synchronizing

Multi-function Relays Provide each generator circuit breaker with a multi-function generator relay in a drawout case to provide protection, control, metering and monitoring of the generator. Locate one 9600 baud RS232 port. The relay shall have Windows based PC software to enable setpoint programming file storage, on-line help, and real time display of status and measured data. General Electric Multilin SR489 series This portion specifically calls out a brand of relay, but does not address the functions that the relay should carry

Multi-function Relays The generator controller shall have the following protection: 1. High AC voltage shutdown 2. Low AC voltage shutdown 3. Over/Under frequency 4. Reverse power 5. Overcurrent 6. Synch check 7.

Synchronizing Panel Provide Synchronizing panel with: 1. One bus AC voltmeter, Crompton digital analog type 2. One synchroscope 3. Two synchronizing lamps Why not take advantage of the modern digital paralleling technology? Manual operation needed? The generator set operator panel shall provide manual and automatic functions for control of the generator set

Metering Provide digital/analog ammeter suitable for the display of all phases (1% accuracy) with ammeter switch for all generators Are the analog meters necessary? The generator and Master HMI should display: Line to line voltage (all three phases simultaneously) Line to Neutral voltage (all three phases simultaneously) Alternator frequency

Paralleling Time All generators shall be paralleled and on-line within 10 seconds following the utility outage May be possible in some situations Size the smallest generator set to handle the critical loads requiring a 10 second compliance time Critical loads should be online within 10 seconds

Specification Building Tool GenSpec Generators Automatic Transfer Switches Switchgear

Summary Remember to write specifications based on functions and performance Listing brand-specific components can limit design options and increase cost Assess how realistic and relevant the specified performance metrics are Be sure to keep specifications current with modern technology

Q&A Type your questions, comments, feedback in the WebEx Q&A box. We will get to as many questions as we can We will publish consolidated FAQ along with presentation and webinar recording on powersuite.cummins.com 37

Q&A Type your questions, comments, feedback in the WebEx Q&A box. We will get to as many questions as we can We will publish consolidated FAQ along with presentation and webinar recording on powersuite.cummins.com Your local Cummins contacts: AZ, ID, NM, NV: Carl Knapp (carl.knapp@cummins.com), Rocky Mountain Region CO, MT, ND, UT, WY: Joe Pekarek (joe.a.pekarek@cummins.com), Rocky Mountain Region Northern IL, IA: John Kilinskis (john.a.kilinskis@cummins.com), Central Region UP of MI, MN, East ND, WI: Michael Munson (michael.s.munson@cummins.com), Central Region NB, SD, West MO, KS: Earnest Glaser (earnest.a.glaser@cummins.com), Central Region South IL, East MO: Jeff Yates (Jeffery.yates@cummins.com), Central Region TX: Scott Thomas (m.scott.thomas@cummins.com), Gulf Region FL, GA, SC, NC and Eastern TN: Robert Kelly (robert.kelly@cummins.com), South Region NY, NJ, CT, PA, MD: Charles Attisani (charles.attisani@cummins.com ): East Region CA, HI: Brian E Pumphrey (brian.pumphrey@cummins.com) WA, OR, AK: Tom Tomlinson (tom.tomlinson@cummins.com) For other states and territories, email powergenchannel@cummins.com or visit http://power.cummins.com/sales-service-locator

Closing Watch out for a follow-up email including A Link to webinar recording and presentation A PDH Certificate Visit powersuite.cummins.com for PowerHour webinar recording, presentation and FAQ archive Other Cummins Continuing Education programs Sizing and spec development tool Please contact Mohammed Gulam if you have any questions related to the PowerHour webinar (mohammed.gulam@cummins.com)