GROUP D. Switch & Protective device.

Similar documents
GROUP C. Apparatus Bushing.

SF 6 Gas Insulated Load Break Switch

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

SWITCHGEAR DIVISION PRODUCT PROFILES

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

PRODUCT CATALOGUE. Overhead System

Type ICX Outdoor open type cutout

Cobra-S. Catalog Cobra-S

Solid Dielectric, Single Phase Recloser

Q pole Pole Mounted Capacitor System

Gas Insulated Metal-clad Switchgear, HMGS!

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Three-Phase Pole Mounted Recloser

Technical Specification for Pole Mounted Capacitor Rack

Product Group Brochure. PS Range Capacitor Vacuum Switches

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Typical Specification

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Medium Voltage Outdoor Apparatus Portfolio 2009

Air-insulated switchgear UniGear type ZS1

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Gas Insulated Switchgear

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Horizontal Circuit Switchers

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Medium Voltage Metal-Enclosed Switches

Horizontal Circuit Switchers

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Disconnect & ByPass Switches

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Solid Dielectric, Single Phase Reclosers

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Medium Voltage Metal-Enclosed Switches

S&C Loadbuster Disconnects

Padmount Solid Dielectric Switchgear Catalog

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Wind Power Solutions. Make Energy Renewable and Reliable!

GENERAL. CONSTRUCTION External

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

OHB Outdoor sulphur Hexafluoride circuit-breaker

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

C1000 Series Automatic Cap Bank

CATALOG. Joslyn Hi-Voltage Overhead reclosers & switches

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Figure 1. HX cutout fuseholders.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

AIR CORE REACTORS. Phoenix Electric Corporation

25 kv Apparatus Bushings

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

34-SDMS-01 SPECIFICATIONS FOR

Figure 1. HX cutout fuseholders. Positive Interruption

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

CP Automatic capacitor bank

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

METAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV

M-Force three-phase switch

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

PRODUCT SELECTION GUIDE

Energy Division. PCA Single Column Polymeric Surge Arrester

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

15 kv and 25 kv Thru-Bushings

MEDIUM VOLTAGE SWITCHGEAR

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Technical Specification For Outdoor Substation Harmonic Filter Banks

GE TRANQUELLTM Surge Arresters

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Chapter 6 Generator-Voltage System

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

EMPAC Metal enclosed capacitor bank for wind applications

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

Transcription:

GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com

Pole-mounted SF Insulated Load Break Switch Manual Operation & Automatic Operation

PYUNGIL pole-mounted type SF insulated load break switch permits fast, efficient modernization of overhead distribution systems for 27kV (400 A or 30 A). It's compact, light weight design assures easy installati on with cross arm mounting and aerial lug or mold cone connection. In addition to the standard porcelain bushing, a variety of options are available including rubber bushing over the epoxy bushing and epoxy bushing. Connecting terminal and mold cone is also available for the porcelain bushing and rubber bushing. PYUNGIL SF switch construction is completely sealed and corrosion resistant, and the color coded operating handle is easily visible from the ground. PYUNGIL SF switch can be applied with the other protective devices for the protective coordination, and it equips indicators for voltage indication, current indication and fault indication. The switch varies by manual type, motorized type and automatic type and can be used together with SCADA systems for distribution automation. Remote Control and Operation (Automatic Type) Locking Device Equipped Self-Locking Function at Low Pressure Excellent Loadbreak and Insulation Performance at Low Pressure Polymeric Bushing Equipped Easy to handle & Light-weighted Porcelain Bushing Available www.pyungil.com

POLE-MOUNTED SF INSULATED LOAD BREAK SWITCH Current Switching Capacity Section Type Rated Voltage Rated Current Rated Frequency Rated Short-time Current Rated Making Current Load Current Cable charging Current Line charging Current Exiting Current No Voltage Rated Control Voltage Power Frequency Withstand Voltage Surge Withstand Voltage (1.2/0 SF Charging Voltage Weight (kg) Loop Current Applied Standard Dry Wet MANUAL 2.8kV 0/0Hz 12.kA/1sec (rms) 32.kA (Peak). times 2A/10 times 7.A/10 times 1.A/10 times 000 times AUTO (Remote) PS11-4M PS11-M PS11-4A PS11-A 400A 30A 400A 30A 400A/200 times 30A/200 times 400A/200 times 30A/200 times 20A/20 times 31.A/20 times 20A/20 times 31.A/20 times 400A/200 times 30A/200 times 400A/200 times 30A/200 times 14A/10 times 21A/10 times 14A/10 times 21A/10 times - 1220V AC/24VDC 0kV/1min 0kV/10sec 10kV 1.kgf/G (at 20) 13 1 170 190 IEC 02-1. ANSI C37. 71

POLE-MOUNTED SF INSULATED LOAD BREAK SWITCH Solid porcelain bushing designed to applicable ANSI/IEEE standards. Termnial type and moldcone type are available, and standard conductor is copper. According to customer's request, higher creepage can be applicable. Rubber bushing connected with the epoxy apparatus bushing designed to applicable ANSI/IEEE standards. Termnial type and moldcone type are available. Standard conductor is copper and aluminum conductor is optional. Epoxy apparatus bushing for elbow connectors designed to applicable ANSI/IEEE standards. Standard conductor is copper and aluminum conductor is optional. Porcelain Bushing Rubber Bushing Epoxy Bushing PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Home Page : www.pyungil.com Tel : 82-31-420-0~3 FAX : 82-31-424-7300

Pad-mounted SF Insulated Load Break Switch Manual Operation, Electrical Operation & Automatic Operation

PYUNGIL SF pad-mounted types SF insulated load break switch is designed to separate or branch the line for underground distribution systems for 27kV (30 Amp). Three way through seven way switch is available for either two-position or three-position loadbreak switches or circuit breakers, and the construction of switch is completely sealed, oil-free, environment-free and corrosion resistant. The insulation material, sulfur hexaflouride (SF) is non-toxic, non-flammable, Arc-extinguishing and minimal maintenance required. Accordingly SF switches are relatively maintenance-free and require no periodic inspection of contact. The controller of the switch for distribution automation has a fault indicating function at fault current or line and central monitoring function. The SF switch is available for indoor, outdoor and pad-mount application and designed to meet the requirements of IEC 02-1, ANSI/IEEE C37.71 and ANSI/IEEE 38 under rigid quality compliance of the ISO 9001 quality assurance program. Excellent Switching Performance Reliable Performance at Low Pressure Minimal Maintenance Compact & Light-weighted Distribution Automation Possible 2 position or 3 position Selectable www.pyungil.com

PAD-MOUNTED SF INSULATED LOAD BREAK SWITCH The SF insulated switches utilize linear puffer interrupters inside a welded stainless steel tank. The stationary contact and piston assembly are housed in cylindrical tubes. The stationary contacts are connected to the cable bushings. As the contacts are closing, the piston assembly compresses the SF between the contacts. This increases the dielectric strength of the gap, minimizing prestriking. The contacts are designed using a tulip bay-o-net construction and the sliding action of the contacts provides a self cleaning action of the main current carrying surface. The contact fingers are designed for increasing contact pressure with increasing current for proper operation during momentary or making conditions. CLOSED OPENNING OPEN CLOSING ITEM VALUE Rated Voltage Rated Current 12kV 30A 2kV 30A Impulse Voltage Rated Frequency 9kV/12kV/10kV 0Hz, 0Hz Power-frequency Withstand Voltage 42kV 0kV DC Withstand Voltage Partial Discharge Short-time Current Rated Making Current Gas Charging Voltage 78kV 19kV 20kA (rms), 4sec 0kA (peak) times 10psiG (at 20) Span of Operating Mechanism Open/Close 000 cycles Open/Earth 1000 cycles Operating Type Applied Standard Manual, Electrical (Motor-operared), Automatic IEC 02-1, ANSI C37.71

Cat. No. D0102 Aug. 2004 PAD-MOUNTED SF INSULATED LOAD BREAK SWITCH Way Voltage Model No. Operation Type Dimension(LWH) Circuit diagram 33-D-M-X Manual 1,2008001,200 3 12/2kV 33-D-A-X 33-D-B-X Electrical Automatic 1,348001,300(S) 1,34901,300(D) 44-D-M-X Manual 1,38001,200 4 12/2kV 44-D-A-X 44-D-B-X Electrical Automatic 1,7008001,300(S) 1,700901,300(D) -D-M-X Manual 1,8728001,200 12/2kV -D-A-X -D-B-X Electrical Automatic 2,038001,300(S) 2,03901,300(D) -D-M-X Manual 2,2088001,200 12/2kV -D-A-X -D-B-X Electrical Automatic 2,3728001,300(S) 2,372901,300(D) 77-D-M-X Manual 2,448001,200 7 12/2kV 77-D-A-X 77-D-B-X Electrical Automatic 2,7088001,300(S) 2,708901,300(D) NOTE : (S) means "Single Connection", and (D) means "Double Connection" PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Home Page : www.pyungil.com Tel : 82-31-420-0~3 FAX : 82-31-424-7300

Polymer-housed Surge Arrester for 3kV to 18kV SURGE ARRESTER GAPLESS METAL OXIDE ARRESTER EASY TO HANDLE AND INSTALL ECONOMICAL SURGE PROTECTION RESISTANT TO BREAKAGE ROBUST DESIGN OPTIONAL GROUND ISOLATOR PYUNGIL polymer surge arresters with EPDM or silicone housing offer safety and convenience features with excellent protective characteristics. The resilience of the polymer housing minimizes the risk of damage in case the arrester is dropped or is subjected tocareless handling during transportation and installation. PYUNGIL arresters comply with the design test of IEC 0099-4, and exceeds ANSI requirements. The operation of the arrester is typical of gapless metal oxide arrester. During steady state conditions, line-to-ground voltage is applied continuously across the arrester terminals. When a surge occurs, the arrester immediately limits the overvoltage to the required protective level by conducting the surge current to ground. Upon passage of the surge, the arrester returns to its initial state. A disconnecting device, which removes the ground terminal from the arrester in the unlikely event of arrester failure, is available; thus, theoretically PYUNGIL arrester prevents a permanent system short circuit.

Cat. No. D0201 Aug. 2004 POLYMER-HOUSED SURGE ARRESTER FOR 3kV TO 18kV Creepage Distance (mm) 3 134 142. 340 134 142. 340 9 171 142. 40 12 171 142. 27 1 227 142. 27 18 24 142. 738 4.1 3 7.20 9 7.2 9 8.32 9.10 12.00 9 1 12.47 9 1 13.20 9.10 1 13.80 10.12 1 20.78 1.18 21 22.90 18 27 8/20 Max. Discharge Voltage (kv Crest) PPA-03 3 2. 11. 9.7 10.4 11. 13.0 PPA-0.10 22.3 19.4 20.8 22.3 2.0 PPA-09 9 7. 33. 29.1 30. 33.0 38.0 PPA-12 12 10.20 44. 38. 40. 44.0 0.3 PPA-1 1 12.70.8 48. 0.7 4.8 2.9 PPA-18 18 1.30.7 8.0 0.9.8 7. PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Home Page : www.pyungil.com Tel : 82-31-420-0~3 FAX : 82-31-424-7300

Cutouts with Polymeric Insulator GAPLESS METAL OXIDE ARRESTER EASY TO HANDLE AND INSTALL ECONOMICAL SURGE PROTECTION RESISTANT TO BREAKAGE ROBUST DESIGN OPTIONAL GROUND ISOLATOR CUTOUTS Protection technologies from overcurrents introduced by abnormal condition have been utilized with cutouts. Recently the state-of-the-art technology of the polymer has been integrated into the conventional overcurrent protection device. PYUNGIL cutouts provides dependable overcurrent protection performance for primary distribution systems. Currently two voltage rated cutouts is available, 1kV and 27kV. PYUNGIL cutouts is electrically and mechanically interchangeable with the other manufacturers' such as S&C, A.B. Chance or ABB cutouts. In addition, Fuse holder interchangeability reduces the time required to replace the fuse during an outage. PYUNGIL cutouts is designed to meet or exceed the requirements of ANSI Standards C37.41-1994 and C37.42-1989, NEMA SG-2-198 and the other relevant industrial standards. PYUNGIL cutouts is available in several frame sizes to match the BIL of each distribution system, in a variety of fault current interrupting ratings and optional load break designs. It can be applied to capacitor banks, transformer banks, and for sectionalizing circuits. It is equipped with hooks for use with a portable load break tool, allowing it to be used to break load currents.

Cat. No. D0204 Aug. 2004 CUTOUTS WITH POLYMERIC INSULATOR Application Fiexibility Reliable Protection Safe & Simple Operation Easy & Quick Installation Optimum Interchangeability Self-Cleaning Function Light Weight Non-Frangibility Good Weatherability SPD-1-10 1kV 110kV 7100/10000A SPD-27-2 27kV 12kV 7100/10000A SPD-27-0 27kV 10kV 8000/12000A Dimension(mm) SPD-1-10 7.8/1 110 429 24 330 12 27 7 SPD-27-2 1/27 12 0 4 34 194 299 111 SPD-27-0 27 10 00 790 388 22 30 143 PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Home Page : www.pyungil.com Tel : 82-31-420-0~3 FAX : 82-31-424-7300