RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

Similar documents
Instruments for the Analysis of Petroleum Products. Oxidation Stability

Solution Sheet 1.

Metrohm. 743 Rancimat. Determination of the oxidation stability of Oils and fats Biodiesel Food and cosmetics

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Instruments for Chemical and Petroleum Products. Flash Point

Cetane ID 510. Customer Presentation. Refining. Petrochemical

measuring vessel air inlet conductivity cell reaction vessel sample absorption solution (water) heating block (e.g. 120 C)

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Penetration. Test Methods

ADU 5. Automatic Distillation Unit

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Callisto 100. Cold Filter Plugging Point Tester

White Paper.

Closed Cup Flash Point Tester

Humidity Cabinet HYGROTHERM

Usb data loggers for cold chain monitoring

Pilodist. Laboratory & process technology. Knowledge & Competence

Heating oven with mechanical control

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Significance of Each Test. 1. Color (Visual)

Stabinger Viscometer SVM 3001

ISO 3679 INTERNATIONAL STANDARD. Determination of flash point Rapid equilibrium closed cup method

Fuels. Test Methods

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

TESTING OF FUELS : FLASH AND FIRE POINT

LUBRICATING OILS. Test Methods

Biodiesel is NOT raw vegetable oil or SVO (Straight Vegetable Oil) or refined oil or filtered used cooking oil.

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Heating oven with natural convection

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Foaming of Lubricating Oils (manual)

CERTIFICATE OF ACCREDITATION

Unit D: Agricultural Equipment Systems. Lesson 1: Understanding Applications of Fluids and Lubricants in Agricultural Equipment

Product Profile. Laboratory instruments. for quality control, analysis and calibration. Fuels

IC18DV/92/SCP - Multipurpose Distillation Plant with Automatic Control

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Jet Fuel Conductivity Analysers & Additive Management systems

SCOPE OF ACCREDITATION

Project Reference No.: 40S_B_MTECH_007

Vertical Tensile Machine

Heating oven with mechanical convection

mass flowmeter for compressed air

Flash Point Process Analyzer

TURBINE OILS GST PREMIUM 32 CALTEX LUBRICANTS FORMULATED TO FIGHT SLUDGE AND VARNISH

Heating chamber with mechanical convection

Heating chamber with mechanical convection

IT SIMPLY WORKS. EMISSION. // Emission control devices

Safety drying ovens. Advantages: Areas of application: FDL series 115

CHAPTER-3 EXPERIMENTAL SETUP. The experimental set up is made with necessary. instrumentations to evaluate the performance, emission and

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Low cost EDXRF elemental analyzer

Optidew Vision Optical Dew-Point Meter

ADDRESSING CHALLENGES AROUND FOOD GRADE GREASE PRODUCTION. ICIS FOOD GRADE LUBRICANTS 23 rd September 2014 in Berlin

Cement Compression & Flexural Testing Machines

POLLUTION CONTROL AND INCREASING EFFICIENCY OF DIESEL ENGINE USING BIODIESEL

Production of Biodiesel from Used Groundnut Oil from Bosso Market, Minna, Niger State, Nigeria

PRODUCT CONFORMITY CERTIFICATE

Heating chamber with mechanical convection

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

The PMAC Dynamic Scale Loop

Heating chamber with mechanical convection

AvCount Laser Particle Counters

Compression/Tension Testing Machines

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Refrigerated incubator with Peltier technology

Innovation in cold behavior

FUELS. Test Methods

Incubators. Incubators

Lubricating Oils. Test Methods

Model ED 400 Drying and heating chambers Classic.Line with natural convection

EBI 3x0 PDF Data Loggers

Combustion Calorimeter System

Gasoline Specifications

The storage stability issue of Biodiesel and the additives solution. Long - Term Storage of Fuels Seminar Israeli Institute of Energy and Environment

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

N E W! The next generation Digital Burette.

RALF At a glance. Bioengineering RALF essentials. General

National Board Update

Draft Indian Standard SYN GAS/ AMMONIA TURBO COMPRESSOR LUBRICATING OILS SPECIFICATION

Abstract Process Economics Program Report 251 BIODIESEL PRODUCTION (November 2004)

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

This document is a preview generated by EVS

Stabinger Viscometer Series. SVM Series

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

HAAKE Viscotester VT550 Plug & Play Application Packages

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Climate chambers with illumination

LUBRICATING GREASES. Test Methods

mass flowmeter for compressed air

Exocet Gas Oil Extra (XO1248GO)

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

MILITARY SPECIFICATION LUBRICATING OIL, VACUUM PUMP, MECHANICAL

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Warter Fuels JSC Aviation Gasoline AVGAS 115/145 Edition II

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

Transcription:

RSSOT New Standards ASTM D 7525 ASTM D 7545 EN RSSOT 16091 ASTM D 7525 ASTM D 7545 Manufacturer since 1873 WWW.PETROTEST.COM

Oxidation Stability Rapid Small Scale Oxidation Test (RSSOT) A new Method for the Determination of the Oxidation Stability Suitable for Diesel, Biodiesel (FAME) & Blends, Gasoline, Grease, Oil, Food, Cosmetics etc. The new Rapid Small Scale Oxidation Test (RSSOT) Methods For Gasoline: ASTM D 7525 covers the quantitative determination of the stability of gasoline (spark ignition fuel), including those containing alcohols or other oxygenates, under accelerated oxidation conditions. For Diesel, Biodiesel (FAME) & Blends: ASTM D 7545 - EN 16091 covers the quantitative determination of the stability of Middle Distillate Fuel. The measured induction period can be used as an indication of the oxidation and storage stability. Compared to some other oxidation and storage stability test methods, this test method uses a small sample and gives a result in a short time period Why testing Oxidation Stability? Sludge formations can ruin modern and sophisticated fuel injection systems by plugging of fi lters! Oil oxidation can scrap machinery! The oxidation of lubricants can affect for example the free movement of bearings! Oil & grease contained in foods are subject to oxidation also and may cause the products to perish! The oxidation stability is covering two important ranges: - Storage Stability (which can be infl uenced by humidity, sunlight, microorganisms, temperature, oxygen in the air etc.) is an important parameter for strategic storage of large quantities and a value of the aging and the shelftime of natural oil and other products. - Thermal Stability can additionally generate Gum and Solid Deposits during storage. This may lead to fi lter plugging. Economical Aspects and Advantages The automatic PetroOXY-method performs a massive reduction of testing time. The handling & cleaning time per test is limited to approx. 5 min. In a small, hermetically sealed test chamber a 5 ml sample is heated together with oxygen. This initiates a very fast, artifi cial aging process, which is displayed by a pressure drop in the system. It was found that the time consumption to the pressure drop is directly related to the oxidation stability. As a result of the improved repeatability, producers can reduce their costs, because now the concentration of valuable additives can be limited closer to the required level. Further fast checks in case of suspicion and accidents are possible, as well as strategic and routine storage monitoring. Results determined by the PetroOXY include all volatile & non-volatile oxidation products and thereby provide a complete analysis of the sample s oxidation stability. Compilation For oxidation stability tests on various products there is a tool now available: The new PetroOXY method! It is quick, economic and the results are well repeatable. Compared with other methods good differentiations are possible. Thanks to improved repeatability, cost reductions are possible by going closer to the limits of specifi cations. 2

RSSOT - Method PetroOXY Apparatus Complies with the requirements of users regarding an improvement of the currently used manual oxidation stability tests: - Small sample volume of 5 ml - Short test time, normally less than 1 hour - Improved user safety - Automatic pressure detection system - Automated oxygen charging & relief - Automatic heating & re-cooling - Easy handling even for less skilled users - No complicated evaluation (as soon as the test is finished the result is displayed) - Interface to transfer test data - Easy cleaning after test run Re-Cooling Alternatives: Metal Re-Cooling Block The block must be stored in a separate freezer to boost the re-cooling of the chamber between two tests. Especially useful in an warm environment. Active Re-Cooling Device It uses Peltier cooling, which allows an automatic re-cooling to a defined temperature in the range of +17 to +24 C. Fully self-contained and liquid-free it is a very easy and safe way of testing. Especially recommended for easy vaporizing fluids like gasoline. 13-3006 Test Cell Alternatives: Aluminum Chamber with galvanic coating High-graded aluminum is used to provide even and super fast heat transfer. The galvanic coating of the cell avoids catalytic effects. Suitable for: fuel, oil and with a sample dish for grease. But not for water containing products. Stainless Steel Chamber High-graded stainless steel in dairy-product quality. Suitable for: water containing products and acid forming samples in the food & cosmetic sector. aluminum chamber with galvanic coating stainless steel chamber with PTFE-sample dish PetroOXY Logger-software A programm for data acquisition and easy update, which is included in each PetroOXY. Features: - online data visualization of pressure and temperature curves during a test - data readout after a test - data storage in xml-format It requires a PC with Windows -plattform with >300 MB hard disk space, CD-ROM drive, mouse and 1 free serial port (RS232 or USB). (Configuration details upon request) Software PetroOXY 3

Gasoline, Diesel, Grease & Oil PetroOXY - Determination of the Oxidation Stability of Fuels (Gasoline, Diesel, Gasoil, Biodiesel (FAME) and Blends), Grease & Oil Product group: Fuels (Gasoline, Diesel, Gasoil, Biodiesel (FAME) & Blends) Current procedures: Oxidation Stability by Induction Period - ASTM D 525 - IP 40 - ISO 7536 The induction period may be used as an indication of the tendency of motor gasoline to form gum in storage. It should be recognized, however, that its correlation with the formation of gum in storage may vary markedly under different storage conditions and with different gasolines. Oxidation Stability of Distillate Fuel Oil - ASTM D 2274, ISO 12 205, ASTM D 5304 This test method provides a basis for the estimation of the storage stability of middle distillate fuels. But it is only possible to discriminate very good and relatively good fuels from very bad fuels. A more precise differentiation is not possible. Oxidation Stability of Fatty Acid Methyl Esters - EN 14 112, EN 15 751 A sample, in a closed reaction vessels, will be exposed to elevated temperatures while pumping air into it. This method detects oxidation stability through conductivity. & 13-3028 PetroOXY procedures: Oxidation Stability of Gasoline - ASTM D 7525 Oxidation Stability of Diesel, Biodiesel & Blends - ASTM D 7545 - EN 16 091 For the determination of the stability of fuels under accelerated oxidation conditions. Compared to some other oxidation and storage stability test methods, this test method uses a small sample and gives a result in a short time period. We recommend: 13-3003 13-3006 13-3007 PetroOXY Block Cooling with Re-Cooling Block Power supply: 115/230 V, 50/60 Hz, EU-plug & -fi lling hose Power supply: 115/230 V, 50/60 Hz, US-plug & -fi lling hose PetroOXY Active Cool with Peltier Re-Cooling Power supply: 115/230 V, 50/60 Hz, EU-plug & -fi lling hose Power supply: 115/230 V, 50/60 Hz, US-plug & -fi lling hose for liquid samples Product group: Grease Current procedures: Oxidation Stability of Lubricating Greases - ASTM D 942, DIN 51808, IP 142 This test method measures the net change in pressure resulting from consumption of oxygen by oxidation and gain in pressure due to formation of volatile oxidation by-products. This test method may be used for quality control to indicate batch-to-batch uniformity. We recommend: 13-3003 PetroOXY Block Cooling with Re-Cooling Block Power supply: 115/230 V, 50/60 Hz, EU-plug & -fi lling hose Power supply: 115/230 V, 50/60 Hz, US-plug & -fi lling hose 13-3028 Sample Dish (see Accessories) with dish for pasty samples Product group: Oil Current procedures: Oxidation Stability of Steam Turbine Oils by Rotating Pressure Vessel (RBOT) - ASTM D 2272, IP 229 The estimate of oxidation stability is useful in controlling the continuity of this property for batch acceptance of production lots having the same operation.this test method is also used to assess the remaining oxidation test life of in-service oils. Oxidation Stability of Turbine Oils (TOST) - ASTM D 943, ISO 4263, etc. This test method is widely used for specifi cation purposes and is considered of value in estimating the oxidation stability of lubricants, like inhibited steam-turbine oils. It is also used for testing hydraulic oils and circulating oils having a specifi c gravity, less than that of water and containing rust and oxidation inhibitors. re-cooling with block We recommend: 13-3003 PetroOXY Block Cooling with Re-Cooling Block Power supply: 115/230 V, 50/60 Hz, EU-plug & -fi lling hose Power supply: 115/230 V, 50/60 Hz, US-plug & -fi lling hose 4

Food, Cosmetics & other Products PetroOXY - Determination of the Oxidation Stability (Aging) of Food, Cosmetics and other Products Possible applications: - Vegetable oils and fats (like margarine or seed oil etc.) - Animal oils and fats (like butter, fi sh oil etc.) - Meltable foods with a high fat content (like butter, cheese, lipstick etc.) - Liquid or semi-liquid foods (like mayonnaise, sauce, cream or lotion etc.) - Solid, non-meltable foods (like nuts, bacon, sausage etc.) Product group: Natural Oils/Fats, Food & Cosmetics To make a statement concerning the oxidation stability respectively the shelf life, the examined sample will be aged artifi cially under controlled test conditions. By raising the temperature or oxygen pressure the period, until signs of spoiling appear, will be reduced from months/weeks to days/hours. The determined induction time characterizes the resistance of oils and fats to oxidation. Compared to similar, already published instruments, the test conditions are more rigid. Therefore the scope of application is extended. After the consumption of the antioxidants (which will be reduced faster due to the increased temperature), volatile and non-volatile products can be determined. The PetroOXY offers an easy and safe method for the fast determination of the oxidation stability even of sensitive oils and fats and is suitable for the qualitative analysis of vegetable cooking oils and greases, further for vegetable grease used in cosmetics. 13-3008 Current procedure: Oxidation Stability of Animal / Vegetable Fats and Oils - ISO 6886, EN 14 112 The determination of the oxidation stability of natural oils and fats through conductivity is a standard quality control method in the food industry. The oils and fats contained in food are also subject to oxidation, which leads to their spoilage. The suitable PetroOXY unit is: PetroOXY Stainless Steel Automatic Oxidation Stability Tester for Water Containing Products like Food, Cosmetics etc. with stainless steel chamber and PTFE Dish 13-3008 Power supply : 115/230 V, 50/60 Hz, EU-plug & -fi lling hose 13-3009 Power supply : 115/230 V, 50/60 Hz, US-plug & -fi lling hose 13-3026 Re-Cooling Block (see Accessories) stainless steel chamber with PTFE-sample dish comparison of food, cosmetics etc. 5

Order-Details Scope of Application This is a new automatic method to evaluate the storage stability of liquid fuels (gasoline, diesel, FAME), grease oil or food and give a qualitative analysis before releasing a product from any production facility or storage. Summary of Method ASTM D 7525 & ASTM D 7545 the new Rapid Small Scale Oxidation Test Methods For a quantitative determination of the stability of fuels under accelerated oxidation conditions. The measured induction period can be used as an indication of the oxidation and storage stability. The PetroOXY test methods use, compared to some other oxidation and storage stability test methods, a small sample only and give good repeatable results in a short time period. Oxidation Stability - PetroOXY Method (automatic) Gasoline Methods: ASTM D 7525 In correlation with: ASTM D 525, IP 40, ISO 7536 FAME / Biodiesel Methods: ASTM D 7545 - EN 16 091 In correlation with: EN 14 112, EN 15 751 Diesel / Gasoil Methods: ASTM D 7545 - EN 16 091 In correlation with: ASTM D 2274, IP 388, ISO 12205 ASTM D 5304 PetroOXY - Automatic Rapid Small Scale Oxidation Tester (RSSOT) Features: Microprocessor controlled Results of 20 tests can be stored. Pressure and temperature are stored once per minute. A maximum of 16000 data-sets can be stored. Data can be exported to a PC. Consisting of: Automatic tester with microprocessor control, high-grade stainless steel housing with two-color powder coating, touch-key panel with large LC-display for pressure and temperature as well as simple display of the pressure curve membrane key pad for selection of desired program and parameters, control electronics with power supply, heating control with safety over-temperature shutoff, cool-down fan, sample cup for 5 ml standard sample, screw cap cover, safety and insulation cover, hose nipples, internal tubing, solenoid valves for automatic pressurization and pressure relief. Supplied with: 1 set seals 1 set cleaning tissues 1 oxygen fi lling line (max. 8 bar) EU/US-type 1 verifi cation fl uid set, 50 ml 1 software PetroOXY-logger 1 data transfer cable 1 USB adapter RS232 1 RS232 adapter DS9/DS25 plug Technical Data: Test place : 1 Test Cell : coated aluminum or stainless steel Working range : up to +200 C Common test range : +120 C to +200 C Heater capacity : 500 W Re-Cooling Device : fan and metal block or Peltier element Temperature sensor : Pt-100 Pressure sensor : 0 to 2000 kpa Interfaces : 1x RS-232 for Printer, 1x RS-232 for data export Dimensions / Weight : 24 x 40 x 26 cm (W x D x H), 11.2 kg Power supply : 115/230 V, 50/60 Hz, EU- or US-plug & -fi lling hose Grease Methods: In correlation with: ASTM D 942, DIN 51 808, IP 142 Oil Methods: In correlation with: ASTM D 943, ISO 4263 ASTM D 2272, IP 229 Food & Cosmetics Methods: In correlation with: ISO 6886, EN 14 112 PetroOXY - model Applications Automatic Rapid Small Scale Oxidation Tester (RSSOT) Block-Cooling Active Cool Stainless Steel Gasoline X X Diesel X X Oil & Grease X X 13-3006 Food Features Order N 13-3003 13-3006 13-3007 13-3008 13-3009 X 115/230 V, EU-plug X X X 115/230 V, US-plug X X X Temperature Range up to +200 C up to +200 C up to +200 C Re-Cooling fan & block fan & active Peltier cooling fan Test Cell coated aluminum coated aluminum stainless steel Sample Dish (option) (option) 10 x 13-3008 Re-cooling Block (option) 6

Order-Details Options & Accessories 13-3026 Re-Cooling Block for faster cool down of the test chamber between tests (must be chilled in a freezer until use) 13-3028 Dish, PTFE, pack of 1 13-3026 13-3033 Reference Fluid - PetroOXY 5x 11 ml, with certifi cate of PetroOXY- & Rancimat EN 14 112-value 13-3028 (13-3029) 13-3035 Pressure Calibration Manometer with adapter Technical Data: Digital pressure gage : 0... 10 bar Accuracy : 0.1% FSS typ Indication : kpa, bar, PSI 13-3037 Works Certificate - PetroOXY about pressure and temperature, with 5 test points each 13-3040 Temperature Calibration Set Consisting of: precision thermometer, measuring chain with temperature sensor, lid and hood 13-3035 13-3049 Service Set - PetroOXY for test cell cleaning and leak detection 13-3054 Bluetooth Set, for wireless connection of 1 instrument (with RS-232 interface) to 1 PC Consumables 13-3022 Pipettes, 5 ml, graduated, made of plastic, pack of 100 13-3025 Cleaning Tissue, pack of 100 13-3049 Spares 13-3021 O-Ring Set, pack of 100 13-3029 Dish, PTFE, pack of 10 13-3034 Verification Fluid - PetroOXY Consisting of: 50 ml aluminum fl ask with diesel oil, 2 pipettes (5 ml) and works certifi cate 13-3030 Oxygen Tubing, EU-version pressure reducing max. 8 bar 13-3031 Oxygen Tubing, US-version pressure reducing max. 8 bar, 1/4 NPT 13-3054 13-3022 (1 of 100) 13-3040 7

Manufacturer of Petroleum Test Equipment since 1873 Petrotest Building Development ISO 9001 certified processes......consolidated at Petrotest! Production Quality Control Storage training Presented by: We reserve the right of changes without prior notice. 98-1510 10/09 Ludwig-Erhard-Ring 13 15827 Dahlewitz - Germany Tel.: +49 (0) 33708 / 56-300 Fax: +49 (0) 33708 / 56-556 E-Mail: info@petrotest.com Website: www.petrotest.com