CONTENTS: Concept Document Layout

Similar documents
GLM SERIES CONTROL Users Manual Rev:

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

AALS - Electric Traction and Control Systems for Miniature Locomotives.

INSTALLING THE #OMEGA-3v9s ESC.

ATA 49 AUXILIARY POWER UNIT

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Quick Start Guide. This is only a quick start guide. A full wiring and installation manual is included in PCLink.

DASSAULT AVIATION Proprietary Data

KD LV Motor Protection Relay

24V 3A EN54 Ancillary Power Supply

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

Programmable 8 Channel Injector Driver Module

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module.

NHP SAFETY REFERENCE GUIDE

Reversing Hand Throttle and Horn Relay Board RBT / HRB

INSTALLATION GUIDE Table of Contents

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

Ultra IBEC Ignition Battery Eliminator Users Manual. Ultra IBEC Features

ATOTH-G Series BLDC Motor Controller. User s Manual

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Components for EEx e Panels

INSTRUCTIONS. DO NOT CONNECT TO MAINS POWER ( V AC).

OMEGA-3v8s Electronic Speed Controller

INSTRUCTIONS. DO NOT CONNECT TO MAINS POWER ( V AC).

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

Service and operate a diesel-electric main line locomotive

Battery Control Center - Diesel

INSTRUCTIONS. DO NOT CONNECT TO MAINS POWER ( V AC).

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

Service and operate an electric main line locomotive

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

Triumph Street Triple VSM Grip Heater Install

CAUTION DO NOT ATTEMPT TO ALTER THE TUNING OF THE RADIO EQUIPMENT. DO NOT USE RADIO CONTROL EQUIPMENT IN THUNDERSTORMS.

OMEGA-3v7 Electronic Speed Controller

DeltaV SIS TM Auxiliary Components

DeltaV SIS TMAuxiliary Components

12VPS TRAK-DT. Block Detection / Signaling Starter Package. 12 VOLT / 0.5 Amp REGULATED POWER SUPPLY. a c t i v a t i o n s e c t i o n

siemens.com/mobility Avenio a rapid ride as tram or light railway Details about vehicle and technology. Avenio fits your city.

TX-1 Digital Proportional R/C

FEATURES AND OPERATIONS

Electronic Circuit Breaker ESS20

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

GA PLUS Ordering Information. Earth Leakage Motor Protection Relay Kits

POWER DOOR LOCKS 8P - 1 POWER DOOR LOCKS CONTENTS

Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable

AL-100DP Full-Feature Vehicle Security System for Factory-Equipped Remote Keyless Entry Transmitters Owner s Guide

PRX-5A-HV. Operating manual. Stabilised receiver power supply. PRX-5A-HV Power for Receiver - High Voltage. Order No. 4176

Installation and Construction Notes for EVSE4

SST-3 Start-Stop-Throttle

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Electrical Awareness and Considerations

Safety technique. Emergency Stop Module BH 5928, BI 5928

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL. TPM 001 Revision 0.1

Blower Drive Checkout for 3GIBC1 Systems

CUSTOMER WIRING INSTRUCTIONS TO SUIT: BA-BF XR6 and XR8 Universal Auto or Manual Trans

Troubleshooting Guide

Modular Standardized Electrical and Control Solutions for Fast Track Projects

INSTRUCTIONS. DO NOT CONNECT TO MAINS POWER ( V AC).

Model APS-20B Owner's Manual

EC225 Power Control System

KEYLESS ENTRY SYSTEM

INSTALLING THE #OMEGA-3v9k ESC.

Rae-San Stock Coil Kit CX_STK_CDI-S CDI-P2. X Stator type G47 rewind Engine Apart to replace Internal Pick Up coils

AP1000 European 7. Instrumentation and Controls Design Control Document

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

AT COMMUNICATION POWER DISTRIBUTION SYSTEM TECHNICAL GUIDE

Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

LH POWER LOCK SYSTEMS 8P - 1 POWER LOCK SYSTEMS TABLE OF CONTENTS POWER DOOR LOCKS... 1 REMOTE KEYLESS ENTRY... 4 POWER DOOR LOCKS TABLE OF CONTENTS

EC328 Power Control System

Electric control panel

EC400 Power Control System

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

MGL Avionics AvioGuard. Fault protected, wide input range, isolated, DC to DC converter for avionics applications

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

OPERATOR S MANUAL 7(5 & ( 8&. $5.00 P/N REV.B

Model K20 installation guide. ProSecurity

INSTRUCTION MANUAL WARNING

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

PEOPLE ARE FAMILIAR WITH THE CONCEPT OF RUNNING A LIGHT FROM A BATTERY AND THEN RECHARGING THE BATTERY USING A SOLAR PANEL OR A WIND-POWERED GENERATOR

System Background and Operation

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Model PRO-9675FT4 Owner's Manual

BigStuff3 - GEN3. 1st Gear Spark Retard with Spark Retard Traction Control System (SR 2 ) Rev

MACHINE SENSORS CONTROL PANEL CONVEYOR SYSTEM SYSTEM SENSORS...

Supercapacitors & Safety

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

2005 Directed Electronics, Inc. Vista, CA N412V 01-05

Mechanical, Electrical, Technology Engineering Firm

EC200 ELECTRONIC CONTROL SYSTEM

LV101 DCC Power Station

ZTC 335 Dual Track Detector Installation Manual

RS900 / RS901 SERIES VI

Model AS-9234E. Owners Guides

WIRELESS DOOR LOCK CONTROL SYSTEM 05DLF 01 REGISTRATION

Operation and Installation Manual

DLRM DLRM

Power Systems Trainer

Transcription:

CONTENTS: Concept Document Layout Part 1: Systems 0 50V (AC/DC) Start by reading this covers 95% of scenarios, so put the simple thing first For locomotive construction that utilises power of voltages no greater than 50V (AC or DC). Part 2: Systems 50V+ Don t read this if you don t have to. For locomotive construction that has higher voltages than 60V essentially the bulk of the existing document. This takes the design to another level. 1. A: ELV definition and requirements 2. B: LV definition and requirements 3. C: Legal aspects (licensed persons to conduct electrical design/testing/approval) 4. D: Failure Analysis, Risk Management etc Basically, if you want to go above 50V, you need to do the work. Otherwise, stick to safety. Part 3: Radio Control Systems - Digital Control only; Analog radio links illegal - Two methods of remote traction control isolation - Loss of signal/broken link failsafe design

PART 1: Systems 0 50V This needs to be as simple as possible. It covers 95% of the hobby at least. MANDATORY All failures of any traction system designed (be it from resistive control through to full digital adaptive control) can be rendered safe and failsafe by the inclusion of three components, wired between the power supply (batteries, alternators etc) and the traction control system (resistors, electronics, wiring to traction motors etc): 1. A manual traction power isolation switch. This disconnects power directly at the source (at the battery, alternator etc). The result is comprehensively rendering the locomotive dead in the event of any electrical failure in any system. 2. A correctly rated fuse or circuit breaker. This limits the maximum failure power between the power supply feed and the traction control system. 3. A normally-open relay, that must be switched from the driver s controls ( ignition ). This ensures power can be removed to the traction control system regardless of any fault with the traction control system (e.g. stuck open throttle). a. The type of switch on the drivers controls is up for debate, but could equally be a key switch or missile-trigger protected toggle switch any type that prevents accidental switching. b. If a Key switch is used, it is suggested a Toggle or latching emergency stop switch is wired in series, ensuring that in an emergency, the keyswitch is not required to be operated for speedy isolation. See SHEET 1 for layout. All components are wired in series in this order. RECOMMENDED The addition of a closed-loop Deadman control is recommended, but not required, if the mandatory conditions are met. The argument has been put forward that no steam locomotive has this feature; but all steam locomotives have a regulator that is identified in a couple of seconds, while most diesel-outlines do not have commonly identified controls identifiable at a glance. A deadman button removes this difference, and requires the driver to constantly acknowledge their presence at the controls. The deadman can take any form, as long as it is triggered when the driver is no longer in control (i.e. is failsafe) could be (certainly not limited to) a pushbutton, a tether latch (similar to a speedway bike), a seat contact (driver falls off, engine stops), a vigilance control with a 10sec timer, or even a guard s button to pull the train up if in an emergency. The presence of this functionality is what is important. See SHEET 1 for layout. Most electronic controllers come with an enable line for exactly this purpose, that must be connected before the controller can operate (i.e. failsafe by nature). It is easily wired in. If the controller does not have this facility, an interposing normally-open relay between the traction control system and the motors themselves can be used, with an identical outcome. See SHEET 2A for interposing relay layout.

MULTIPLE-VOLTAGE SYSTEMS Many miniature locomotives utilise multiple different voltages for their systems. For example, most locomotives traction systems are a higher voltage (24V or 48V) than the auxiliary control system (usually 12V, to run lights, horns, air brakes, relays etc). In order to ensure multiple voltages in use on a locomotive are adequately able to be isolated, the manual isolator must be located at a point in the system that, when operated, removes power from both the Traction and Control/Auxiliary systems together. This comprehensively renders the locomotive dead in the event of any electrical failure in any onboard system. When using batteries in series, the isolator must be wired directly after the first battery in the chain, before any power connections are made. This has the net effect of isolating both the traction and control/auxiliary power. See SHEET 2B for manual isolator position within battery arrangement.

PART 2: Systems > 50V Existing document covers standards, procedures, failure analysis etc. A note can be added to simply say PART 1 covers up to 120V ripple-free DC also. Don t change the title of Part 1 keep it simple for most people. If you re reading this part, you actually want to know. Basically, if you re going down this path, you have to be prepared to wear the pain of jumping through the big-boy-pants hoops to get there.

PART 3: Radio Control Systems (R/C) With the rapid development of radio control gear during the last two or three decades, radio control has become far more predictable in failure, moving in the direction of failsafe control. Drones and model aircraft have pushed this technology to be better at mitigating any failure scenario, which has reduced the risk of crashing expensive equipment or in this case, preventing the loss of control of a locomotive. As such: MANDATORY 1. All radio control systems for use on miniature locomotives must be of digital control. No analogue radio system is to be used, as these systems by their nature go into an unknown state when the signal is lost in most cases, and are susceptible to crosstalk or interference from similar-frequency controllers. 2. All digital radio control systems must include/be configured to return to the off position in the event of either loss of signal or corruption/interference of signal. In practical terms, this means any locomotive under digital remote control must come to an immediate stop if the locomotive: - Runs out of range - The transmitter fails (battery flat etc) - Another transmitter is used in the vicinity that affects the control. Luckily, modern digital frequency-hopping systems are fully capable of doing these things with no intervention, provided these protections are turned on. This can be comprehensively and simply tested by driving the locomotive under radio control (at a safe speed on an empty, looped track) and turning the transmitter off (or disconnecting the batteries in the transmitter). RECOMMENDED 1. Locomotives should be fitted with a physical activation system that interrupts the traction circuit in the same way either the ignition switch or deadman control renders the traction system failsafe. This can take any form, but be accessible to a person standing adjacent to the track, should a locomotive under radio control pass by. Possible implementations may consist of (but are not limited to): - A normally-closed latching pushbutton - A lever or bar somewhere on the locomotive, operating a latching electrical interrupt - A toggle switch All of which are wired in series with the ignition or deadman circuit, so upon activation, the locomotive traction power is removed. It is recommended to have this activation also apply brakes. 2. Provide a second method of failsafe control. a. Utilise a multiple-channel transceiver system, with one channel dedicated to maintaining a healthy relay state on the ignition or deadman circuits. This

separates the radio control operation from the speed control, so if one channel (or the speed control) fails, the other channel can be used to stop the locomotive, removing power from the traction system. OR b. Use a separate remote control system as a redundant link. This could either be a physically separate system utilising an entirely different transmitter/receiver pair, or a separate receiver that listens to the single transmitter, opening the ignition or deadman relays if the transmitter is no longer detected as being healthy. This is a technologically-advanced option, but is in widespread use in industry.