STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

Similar documents
GLX. Series. 1kW to 16kW Central System

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

Micro Lighting Inverter

Illuminator Series CR NEMA 3R

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

EMEX. Central Battery Systems Emergency Lighting

CEPS Series UL924 Emergency Lighting Inverters

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

RELIABILITY THROUGH TECHNOLOGY

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Sola/Hevi-Duty S3K Series Mini-Tower UPS

TLE Series UPS 400/500 kw With eboost Technology

POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER

Crucial Power Products

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TECHNICAL GUIDE SPECIFICATIONS

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

SURE-LITES LIFEWAY II SERIES

Technical Data Sheets

Illuminator System Series CIII

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

SURE-LITES LIFEWAY II Series C & IPS

SUBSTATION EQUIPMENT - Page 1 of 8

Alphapower HTU UPS. Some key features include:

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Aurora Single Phase Emergency Lighting Inverters

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

2 Uninterruptible Power Systems

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

AT30 SERIES BATTERY CHARGER

3 Uninterruptible Power Systems

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Technical Data Sheets

Uninterruptible Power Supplies

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Product Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

3 Uninterruptible Power Systems

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz

56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof

TECHNICAL DATA SHEET KVA UPS Systemss

Power+ CLASSIC. 20/30 kva, 3x208 Vac

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Uninterruptible Power Systems

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

UL AND CODE COMPLIANCE

3 Uninterruptible Power Systems

Technical Data Sheets

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features

Table of Contents 文管中心 發行章

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

TECHNICAL GUIDE SPECIFICATIONS

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

OutdoorXUPS-600AHV-8364

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

WHY STACO ENERGY PRODUCTS?

Solar Inverter Manual

Liebert PowerSure PSI UPS

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

3 Uninterruptible Power Systems

Uninterruptible Power System

Automatic DC Power Supply/Battery Charger

PureSine 150/300 Pure Sine Wave Inverter User s Manual

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Transfer switch OTEC open or delayed transition

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

INVERTER/CHARGERS Off-Grid Power Solutions

Transcription:

STL Series Emergency Lighting Inverter 3kW to 160kW Central System

STL Series Sine Wave APPLICATIONS: The STL Series Inverter will operate incandescent, fluorescent, HID and LED lamps. *Depending on the LED driver inrush current it may be necessary to derate the inverter in certain situations. Airports Assisted Living Centers Casinos Grocery Stores Hotels Medical Movie Theaters Parking Garages Race Tracks Religious Facilities Department Stores Shopping malls Superstores Apartments/Condominium Complexes Banks, Financials City, County, State, Federal Hospitals Industrial Military Complexes Office Buildings Prisons Train, Subway, Bus Stations Restaurants Schools, Colleges Sport Facilities Tunnel and Toll Bridges 1

RATINGS TABLE Size Input Volts Maximum Amps Recommended Breaker Battery Voltage Strings # of battery cabinets 3000 208Y120 10.4 15 384 1 1 3000 480Y277 4.5 15 384 1 5000 208Y120 17.3 25 384 1 1 5000 480Y277 7.5 15 384 1 6000 208Y120 20.8 30 384 1 1 6000 480Y277 9.0 15 384 1 8000 208Y120 27.8 35 384 1 1 8000 480Y277 12.0 15 384 1 10000 208Y120 34.7 45 384 1 1 10000 480Y277 15.0 20 384 1 15000 208Y120 52.0 70 384 2 2 15000 480Y277 22.6 30 384 2 20000 208Y120 69.4 90 384 2 2 20000 480Y277 30.1 40 384 2 24000 208Y120 83.3 125 384 2 2 24000 480Y277 36.1 50 384 2 30000 208Y120 104.1 150 384 2.0 2 30000 480Y277 45.1 60 384 2 35000 208Y120 121.4 150 384 2 2 35000 480Y277 52.6 70 384 2 40000 208Y120 138.8 175 384 2 2 40000 480Y277 60.1 80 384 2 50000 208Y120 173.5 225 384 2 2 50000 480Y277 75.2 100 384 3 3 Maximum amps calculated at high charge full load initially after power failure. Recommended circuit breaker is rated at 1.25 times the maximum amps rounded up. 70000 208Y120 242.9 300 480 3 3 70000 480Y277 105.2 150 480 or 4 4 80000 208Y120 277.6 350 480 5 5 80000 480Y277 120.3 150 480 or 4 4 100000 208Y120 347.0 500 480 4 4 100000 480Y277 150.4 200 480 or 5 5 128000 208Y120 444.1 600 480 7 7 128000 480Y277 192.5 250 480 5 5 160000 208Y120 555.2 700 480 9 9 160000 480Y277 240.6 300 480 6 6 * Consult factory for other options. ** Input currents are shown at high charge with full load rating per UL. Normal running currents are considerably less. 2

Dimensions for A: 7kW and under 32 W x 72 H x 32 D Dimensions for B: Over 7kW 64 W x 72 H x 32 D 72 64 32 *Battery Cabinets 1-8 depending on unit size *32 x 32 goes to 40/kW 64 is above 40kW 3

STL Series Sine Wave System Overview: The STL Series Inverter provider efficient AC Emergency Power to operate all emergency lighting fixtures at full-light output providing superior dependability and security to commercial, industrial, Institutional environments. The STL Series Emergency Lighting Inverter from IEP Systems is designed to provide power to emergency and other critical loads in the event of a power failure or brownout situation. The line voltage output allows the remote fixtures to be located up to 2000 feet from the unit. Power Factor:.9 leading to.9 lagging STL series inverter is designed to occupy a minimum footprint and has a separate compartment for main electronics and for batteries. The STL series is a rugged, modular emergency lighting inverter. Typical applications include all types of LED, fluorescent, incandescent, quartz re-strike, HID and low voltage lighting. The modular design and low MTTR (mean-time-to-repair) ensure easy maintenance. The STL is well suited for stairwell, hallway, and outdoor emergency egress lighting, large size office buildings and warehouses. STL Series inverter employs premium Valve Regulated lead Acid (VRLA ) batteries, designed with an expected service life of 10 years per battery manufacturer guidelines. *VRLA do not need to have electrolyte added. Periodic checks, coupled with standard record keeping and maintenance of the inverter would ensure the longevity of the battery module. Theory of Operation: The STL is designed to power the emergency egress lighting at full brightness for 90 minutes. The system is installed between the switch gear and the emergency panel system will operate loads to.5 leading to.5 lagging. Upon failure of the normal power source to the connected lights, the STL will continue to power the emergency fixtures connected to it for a minimum of 90 minutes utilizing standard building lighting components. When the normal power is restored the STL will automatically switch the lighting fixtures back to the normal source and recharge the batteries so that they are ready for the next power outage. Applications: The STL Series Inverter will operate incandescent, fluorescent, HID, and LED lamps with power factor greater than.9. *Self ballasted compact fluorescent and replacement LED screw in lamps may be used provided they have rated power factor of.9 or greater. *we recommend that only Energy Star recognized compact fluorescent or LED lamps be used with this equipment. Operating Parameters: Run Time: minimum 90 minutes Housing: Heavy duty steel construction finished in powder coat paint. Environment: Operating temperature: 32F (0C) 104F (40C) Altitude: 10,000 feet above sea level without derating Storage temperature: -20 to 70 degrees C. Note batteries will require frequent recharging if stored above 35 degrees C. STL design will provide full rated VA output from.9 leading to.9 lagging power factor. Loads outside of this power factor will reduce the total output of the unit depending on the VA at that power factor. 4

Order Information STL 700 120 120 OPTIONS STL STL Series Pure Sine Wave Lighting Inverter Capacity 3KW 5KW 6KW 8KW 10KW 15KW 20KW 24KW 30KW 35KW 40KW 50KW 70KW 80KW 100KW 128KW 160KW AC Input Voltage 120/208V 277/480V AC Output Voltage 208/120V 480/277V RUNTIME (Other than 90 Minutes) R30-30 Minutes R120-120 Minutes OPTIONS I - Inverter on Dry Form C Contact S - Summary Dry Form C Contacts P - Input Trip T - Output Trip (supervised) Alarm B - Battery Trip (Alarm) C - Circuit breakers (additional) Z - Seismic Mounting Warranty 2YW - Factory Start-up & 2nd Year Electronics Warranty 5YW - 5-Year Electronics Warranty (Includes Start-up) 5YP - 5-Year Maintenance Plan, Start-up Included *Consult factory for other configuration/options *Battery Cabinets 1-8 depending on unit size A: PO Box 20302 Lehigh Valley PA 18002 V: (610) 351 1907 W: www.iepsys.com E: info@iepsys.com 5

STL Series Sine Wave OVERVIEW: Cooling Fan IGBT Heat Sink DC Filter Capacitor AC Filter Capacitor Byass Fuses 6 IGBT Driver Board Main Breaker Connection Terminals

Display Panel Black powder coated paint 7

STL Series Sine Wave Operating Parameters: Run Time: minimum 90 minutes Housing: Heavy duty steel construction finished in powder coat paint. Environment: Operating temperature: 32F (0C) 104F (40C) Altitude: 10,000 feet above sea level without derating Storage temperature: -20 to 70 degrees C. Note batteries will require frequent recharging if stored above 35 degrees C. Battery life expectancy is based on an operating ambient temperature of 20-30 degrees C. STL design will provide full rated VA output from.9 leading to.9 lagging power factor. Loads outside of this power factor will reduce the total output of the unit depending on the VA at that power factor. Additionally, universal, input voltage drivers operating at 277volts may require larger inverters because of inrush of driver parameters. r factor. Options: Suffix NOR - Normally off relay 1 required for every uprest of load Normally off relay required period put relay limited to 20Amp at 120v or 15Amps at 277V AC. NOR - (coil voltage matches single phase input voltage of unit). Suffix ITP Input breaker trip alarm Suffix OTP Output breaker trip alarm, 1 per output breaker Suffix BTP Battery breaker trip alarm Suffix OCB Additional output circuit breakers (note 20 amp output breakers are standard unless otherwise specified. Suffix R30 - Battery capacity of 30 minutes for when the system is used with a permanently installed emergency generator. Suffix R120 Battery capacity of 120 minutes ( may require additional enclosures depending on the rating of the unit). Suffix RS232 - Standard features: All electronics are in 1 cabinet. Battery cabinets are modular. Heavy gauge cold-rolled steel construction finished in powder coat paint. IGBT technology, low THD with high reliability and high efficiency. MTTR of less than 30 minutes for any one component. ETL listed to UL 924, meets or exceeds the requirements of OSHA, NEC, NFPA and other codes Input breakers and output breakers standard features. Battery breakers in each battery cabinet. Two door access to electrical/electronic cabinet for ease of installation, wiring and maintenance. Front mounted meter panel for intuitive system status. Basic alarms for overload, overload shutdown, high temperature, near low battery and low battery shutdown. Bottom wiring channel. 97% efficiency on standby. Fan operation is dependent upon internal temperature and discharge condition to elongate fans useful service life. Specifications: Input: Voltage: 208Y/120 or 480Y/277 VAC 4 wire plus ground +/- 15% Frequency: 60 Hz +/- 3 Hz Protection: Circuit Breaker Output: Voltage: 208Y/120 or 480Y/277 VAC 4 wire plus ground Frequency: 60 Hz +/-.5 Hz THD: > 3% Linear load Regulation: +/- 3% for 50% load change Inverter overload: 110% for 5 minutes Protection: Output Circuit Breaker Battery: Type: Premium 10 year design life Valve Regulated Lead Acid (VRLA) Voltage: See chart for string voltage and number of strings Protection: Battery circuit breaker 8

Power Rating: Capacity: 3KW 160KW Three phase output with latest PWM technology to provide the most advanced performance and reliability. Input: 208V/120V or 480V/277* Output: 208V/120V or 480V/277 VAC true on-line design Efficiency: >92% efficient at 100% linear load Batteries: Sealed, maintenance-free, lead calcium (AGM) batteries with10 year prorated warranty. The STL employs Smart Battery Monitoring System which is temperature compensated and maintains maximum run-time and battery life. Battery life is offset by combined temperature. Electronics: Microprocessor controlled; recharge and over charge protection standard Lamps and Loads: Emergency power provides FULL LIGHT OUTPUT from all lamps and HID lighting for the entire run-time. STL Series Inverter operates fluorescent, CFL, incandescent, quartz, LED and other approved lamp types and loads. Protection: Provides overload, surge and voltage protection. Surge protection against load surges as defined in ANSI/IEEE C62.45 category A and B. Diagnostics and Maintenance: STL Series On-board Monitoring System provides complete self checking capabilities and LED Indicator light Monitor. Informative advanced Metering Display and Alarms keep you in control of your emergency lighting environment 24/7. Automatically performs checking ensuring a safely lighted environment prior to an emergency Single point of testing instead of hundreds with battery packs. Installation: Modular design and small footprint allow easy installation in electrical closet or other convenient locations. Extended warranty available. Warranty Options: 2YW - Factory Start-up & 2nd Year Electronics Warranty 5YW - 5-Year Electronics Warranty (Includes Start-up) 5YP - 5-Year Maintenance Plan, Start-up Included Codes: Listed to UL 924, NFPA 101, NFPA 70, NEC and OSHA Cabinet: Space saving small footprint Free Standing Indoor NEMA 1 enclosure with modular design enables flexible installation. 9

STL Series Sine Wave CONTACT US IEP Systems A PO Box 20302 Lehigh Valley PA 18002 P tel: (610) 351 1907 W website: www.iepsys.com E e-mail: info@iepsys.com