SOLAR PV standard Plan-Simplified Central/String Inverter Systems for One and Two Family Dwellings

Similar documents
Job Address: Permit #: Contractor/Engineer Name: License # and Class: Signature: Date: Phone Number:

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Job Address: Permit #:

Solar PV Standard Plan Simplified Central/String Inverter Systems for 10 KW or less One- and Two-Family Dwellings

Solar PV Standard Plan Central/String Inverter Systems for One- and Two-Family Dwellings

Use this plan ONLY for utility-interactive central/string inverter systems. This plan is not intended for bipolar systems,

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Applicant and Site Information Job Address: Permit #:

Solar Standard Plan Simplified Systems for - and Two-Family Dwellings

STREAMLINED SOLAR CHECKLIST Owner Name:

CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

2. Fire Department Inspections are required and available by appointment on Tuesdays and Wednesdays. See item number four for fees.

Submittal Requirements Bulletin Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Solar Rooftop Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

CITY OF SONOMA - TOOLKIT DOCUMENT #1

The following permits are required to install a solar PV system with a maximum power output of 10 kw or less:

City of Daly City Department of Economic and Community Development Building Division th Street, Daly City. CA

Solar PV Standard Electrical Plan

Solar PV Standard Electric Plan

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

PHOTOVOLTAIC SYSTEMS

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

EXPANSION JOINT DETAILS DURA-BLOK CONDUIT SUPPORT CONDUIT ATTACHMENT DETAIL SCALE: NOT TO SCALE GROUNDING WIRE DETAIL SCALE: NOT TO SCALE

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

CHAPTER 10 ELECTRICAL. Notes:

Solar Power Installation Application

2016 Photovoltaic Solar System Plan Review List

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Photovoltaic Solar Plan Review

SOLAR PV INSTALLATIONS

Solar Eligibility Checklist for Expedited Photovoltaic Permitting for One- and Two-Family Dwellings

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

Electrical Design/Build Guide

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

ENGINEERING SPECIFICATION

Technical Summary of Battery Energy Storage Systems

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

Residential Photovoltaic (PV) Packet

City of Manhattan Beach Community Development

Know the Code: PV and NEC

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

Green Building Technology

Mike Holt s Illustrated Guide to SOLAR PV SYSTEMS

Non-Residential Solar Energy Photovoltaic (PV) Packet

City of Manhattan Beach Community Development

CHAPTER 10 ELECTRICAL

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

Code Calculations. for an Off-Grid PV System

APPROACHING. The Inverter. 92 IAEI NEWS May.June approaching the inverter

Load Side PV Connections

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

hat inspectors need to know

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number:

CHAPTER V RESIDENTIAL WIRING

Temporarily Approved Solar Photovoltaic System Electrical Schematics

CPS 3Phs String Inverters NEC 2014 Compliance

A Look at the 2017 NEC Significant Changes

PV Installations 2015 Electrical Code & more. Presented by: Ted Olechna Director Codes and Standards Support

XXX RESIDENCE : XXX kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM

Photovoltaic Installations

PART A General Conductor Requirements

March Commercial Distributed Generation with Optional Energy Storage Systems

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Spring Test 10 due 05/11/2013

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Residential microinverter system

SINGLE PHASE WIRING SPECIFICATIONS

Code Compliance. Perspectives on PV. Back to the Grid, Designing PV Systems for

COVER VICINITY MAP SCOPE OF WORK ELECTRICAL NOTES GOVERNING CODES SHEET INDEX

THREE PHASE WIRING SPECIFICATIONS

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

Electrical Tech Note 106

33'-10"± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9"± 25'-5"

THIS PANEL FED FROM INV1. PER NEC 408.4(B) Part No NEC (C) Entrances to rooms or other guarded locations that contain exposed live

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast

SECTION SOLAR ENERGY ELECTRICAL POWER GENERATION SYSTEM

Oncor Application for Interconnection of Distributed Generation

DIRECTORY, IDENTIFICATION, LABEL, MARKING, PLAQUE, AND SIGN REQUIREMENTS FOR SOLAR PV SYSTEMS

Application Note Three Phase String Inverters NEC 2014 Compliance

Supply-Side PV Connections

The Reliable Choice. Field Pocket Guide

SECTION SOLAR ENERGY ELECTRICAL POWER GENERATION SYSTEM

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

Spring Test 7 due 05/03/2013

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

Bulletin Wiring methods for Solar Photovoltaic Systems Rules and , Tables 11 and 19

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual

NEC 2014 Code Changes

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

Transcription:

SOLAR PV standard Plan-Simplified entral/string Inverter Systems for One and Two Family Dwellings 21815 Pioneer Boulevard Hawaiian Gardens, a 90716 (562) 420 2641 E-002-a EFFETIVE : 9-31-2015 SOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a system A inverter output rating of 10kW on the roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to the load side of a single-phase A service panel of nominal 120/240Vac with a bus bar rating of 225A or less. This plan is not intended for bipolar systems, hybrid systems or systems that utilize storage batteries, charge controllers, trackers, more than two inverters or more than one D combiner (non-inverter-integrated) per inverter. Systems must be in compliance with current alifornia Building Standards odes and local amendments of the authority having jurisdiction (AHJ). Other Articles of the alifornia Electrical ode (E) shall apply as specified in 690.3. MANUFATURER S SPEIFIATION SHEETS MUST BE PROVIDED for proposed inverter, modules, combiner/junction boxes and racking systems. Installation instructions for bonding and grounding equipment shall be provided, and local AHJs may require additional details. Listed and labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling (E 110.3). Equipment intended for use with PV system shall be identified and listed for the application (E 690.4[D]). Job Address: ontractor/ Engineer Name: Signature: Date: Permit #: License # and lass: Phone Number: Total # of Inverters installed: (If more than one inverter, complete and attach the Supplemental alculation Sheets and the Load enter alculations if a new load center is to be used.) Inverter 1 A Output Power Rating: Watts Inverter 2 A Output Power Rating (if applicable): Watts ombined Inverter Output Power Rating: 10,000 Watts Location Ambient Temperatures (heck box next to which lowest expected temperature is used): 1) Lowest expected ambient temperature for the location (T L ) = Between -1 to -5 Lowest expected ambient temperature for the location (T L ) = Between -6 to -10 Average ambient high temperature (T H ) = 47 Note: For a lower T L or a higher T H, use the omprehensive Standard Plan D Information: Module Manufacturer: Model: 2) Module V oc (from module nameplate): Volts 3) Module I sc (from module nameplate): Amps 4) Module D output power under standard test conditions (ST) = Watts (ST)

5) D Module Layout Identify each source circuit (string) for inverter 1 shown on the roof plan with a Tag (e.g., A, B, ) Number of modules per source circuit for inverter 1 Identify, by tag, which source circuits on the roof are to be paralleled (if none, put N/A) ombiner 1: ombiner 2: Total number of source circuits for inverter 1: 6) Are D/D onverters used? Yes No If No, skip to STEP 7. If Yes, enter info below. D/D onverter Model #: Max D Output urrent: Amps Max # of D/D onverters in an Input ircuit: D/D onverter Max D Input Voltage: Volts Max D Output Voltage: Volts D/D onverter Max D Input Power: Watts 7) Max. System D Voltage Use A1 or A2 for systems without D/D converters, and B1 or B2 with D/D converters. A1. Module V O (STEP 2) = x # in series (STEP 5) x 1.12 (If -1 T L -5, STEP 1) = V A2. Module V O (STEP 2) = x # in series (STEP 5) x 1.14 (If -6 T L -10, STEP 1) = V Table 1. Maximum Number of PV Modules in Series Based on Module Rated VO for 600 Vdc Rated Equipment (E 690.7) Max. Rated Module VO (*1.12) 29.76 31.51 33.48 35.71 38.27 41.21 44.64 48.70 53.57 59.52 66.96 76.53 89.29 (Volts) Max. Rated Module VO (*1.14) 29.24 30.96 32.89 35.09 37.59 40.49 43.86 47.85 52.63 58.48 65.79 75.19 87.72 (Volts) Max # of Modules for 600 Vdc 18 17 16 15 14 13 12 11 10 9 8 7 6 Use for D/D converters. The value calculated below must be less than D/D converter max D input voltage (STEP #6). B1. Module V O (STEP 2) x # of modules per converter (STEP 6) x 1.12 (If -1 T L -5, STEP 1) = V B2. Module V O (STEP 2) x # of modules per converter (STEP 6) x 1.14 (If -6 T L -10, STEP 1) = V Table 2. Largest Module VO for Single-Module D/D onverter onfigurations (With 80V AFI ap) (E 690.7 and 690.11) Max. Rated Module VO (*1.12) (Volts) Max. Rated Module VO (*1.14) (Volts) D/D onverter Max D Input (STEP #6) (Volts) 30.4 33.0 35.7 38.4 41.1 43.8 46.4 49.1 51.8 54.5 57.1 59.8 62.5 65.2 67.9 70.5 29.8 32.5 35.1 37.7 40.4 43.0 45.6 48.2 50.9 53.5 56.1 58.8 61.4 64.0 66.7 69.3 34 37 40 43 46 49 52 55 58 61 64 67 70 73 76 79 8) Maximum System D Voltage from D/D onverters to Inverter Only required if Yes in STEP 6 Maximum System D Voltage = Volts

9) Maximum Source ircuit urrent Is Module I S below 9.6 Amps (STEP 3)? Yes No (if No, use omprehensive Standard Plan) 10) Sizing Source ircuit onductors Source ircuit onductor Size = Min. #10 AWG copper conductor, 90 wet (USE-2, PV Wire, XHHW-2, THWN-2, RHW-2) For up to 8 conductors in roof-mounted conduit exposed to sunlight at least ½ from the roof covering (E 310) Note: For over 8 conductors in the conduit or mounting height of lower than ½ from the roof, use omprehensive Plan. 11) Are PV source circuits combined prior to the inverter? )? Yes No If No, use Single Line Diagram 1 with Single Line Diagram 3 and proceed to STEP 13. If Yes, use Single Line Diagram 2 with Single Line Diagram 4 and proceed to STEP 12. Is source circuit OPD required? Yes No Source circuit OPD size (if needed): 15 Amps 12) Sizing PV Output ircuit onductors If a combiner box will NOT be used from [STEP 11], Output ircuit onductor Size = Min. #6 AWG copper conductor 13) Inverter D Disconnect Does the inverter have an integrated D disconnect? Yes No If yes, proceed to STEP 14. If no, the external D disconnect to be installed is rated for Amps (D) and Volts (D) 14) Inverter information Manufacturer: Model: Max. ontinuous A Output urrent Rating: Amps Integrated D Arc-Fault ircuit Protection? Yes No (If No is selected, omprehensive Standard Plan) Grounded or Ungrounded System: Grounded Ungrounded A Information: 15) Sizing Inverter Output ircuit onductors and OPD Inverter Output OPD rating = Amps (Table 3) Inverter Output ircuit onductor Size = AWG (Table 3) Table 3. Minimum Inverter Output OPD and ircuit onductor Size Inverter ontinuous Output urrent Rating (Amps) (STEP#14) 12 16 20 24 28 32 36 40 48 Minimum OPD Size (Amps) 15 20 25 30 35 40 45 50 60 Minimum onductor Size (AWG, 75, opper) 14 12 10 10 8 8 6 6 6 Integrated D Arc-Fault ircuit Protection? Yes No (If No is selected, omprehensive Standard Plan) Grounded or Ungrounded System? Grounded Ungrounded

16) Point of onnection to Utility Only load side connections are permitted with this plan. Otherwise, use omprehensive Standard Plan. Is the PV OPD positioned at the opposite end from input feeder location or main OPD location? Yes No If Yes, circle the Max ombined PV System OPD(s) at 120% value as determined from STEP 15 (or STEP S20), bus bar Rating, and Main OPD as shown in Table 4. If No, circle the Max ombined PV System OPD(s) at 100% value as determined from STEP 15 (or STEP S20), bus bar Rating, and Main OPD as shown in Table 4. Per 705.12(D)(2): [Inverter output OPD size [STEP #15 or S20] + Main OPD Size] [bus size (100% or 120%)] Table 4. Maximum ombined Supply OPDs Based on Bus Bar Rating (Amps) per E 705.12(D)(2) Bus bar Rating 100 125 125 200 200 200 225 225 225 Main OPD 100 100 125 150 175 200 175 200 225 Max ombined PV System OPD(s) at 120% of bus bar Rating Max ombined PV System OPD(s) at 100% of bus bar Rating 20 50 25 60* 60* 40 60* 60* 45 0 25 0 50 25 0 50 25 0 *This value has been lowered to 60 A from the calculated value to reflect 10kW A size maximum. Reduction of the main breaker is not permitted with this plan. Otherwise, use omprehensive Standard Plan. 17 & 18 & 19) Labels and Grounding and Bonding This content is covered by the labels on Page 4 and the Single Line Diagram(s). For background information, refer to the omprehensive Standard Plan.

Solar PV Standard Plan Simplified entral/string Inverter Systems for One- and Two-Family Dwellings Markings E Articles 690 and 705 and R Section R331 require the following labels or markings be installed at these components of the photovoltaic system: WARNING INVERTER OUTPUT ONNETION; DO NOT RELOATE THIS OVERURRENT DEVIE E 705.12(D)(7) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] WARNING ELETRI SHOK HAZARD. THE D ONDUTORS OF THIS PHOTOVOLTAI SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED E 690.35(F) [Only required for ungrounded systems] WARNING: PHOTOVOLTAI POWER SOURE R R331.2 and F 605.11.1 [Marked on junction/combiner boxes and conduit every 10 ] ode Abbreviations: alifornia Electrical ode (E) alifornia Residential ode (R) alifornia Fire ode (F) J/Box M A INVERTER D WARNING DUAL POWER SOURES SEOND SOURE IS PHOTOVOLTAI SYSTEM RATED A OUTPUT URRENT- AMPS A NORMAL OPERATING VOLTAGE VOLTS E 690.54 & E 705.12(D)(4) PV SYSTEM A DISONNET RATED A OUTPUT URRENT - AMPS A NORMAL OPERATING VOLTAGE VOLTS E 690.54 WARNING ELETRI SHOK HAZARD IF A GROUND FAULT IS INDIATED, NORMALLY GROUNDED ONDUTORS MAY BE UNGROUNDED AND ENERGIZED E 690.5() [Normally already present on listed inverters] WARNING ELETRI SHOK HAZARD DO NOT TOUH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION E 690.17 PV SYSTEM D DISONNET RATED MAX POWER-POINT URRENT- AD RATED MAX POWER-POINT VOLTAGE- VD SHORT IRUIT URRENT- AD MAXIMUM SYSTEM VOLTAGE- VD E 690.53 Informational note: ANSI Z535.4 provides guidelines for the design of safety signs and labels for application to products. A phenolic plaque with contrasting colors between the text and background would meet the intent of the code for permanency. No type size is specified, but 20 point (3/8 ) should be considered the minimum. E 705.12 requires a permanent plaque or directory denoting all electric power sources on or in the premises.

Solar PV Standard Plan Simplified entral/string Inverter System for One- and Two-Family Dwellings ONDUTOR/ONDUIT SHEDULE TAG DESRIPTION AND ONDUTOR TYPE ONDUTOR NUMBER OF SIZE ONDUTORS A USE-2 OR PV-WIRE B D ONDUIT/ABLE TYPE ONDUIT SIZE

Solar PV Standard Plan Simplified entral/string Inverter System for One- and Two-Family Dwellings OMBINER ONDUTOR/ONDUIT SHEDULE DESRIPTION AND ONDUTOR NUMBER OF ONDUIT/ABLE TAG ONDUTOR TYPE SIZE ONDUTORS TYPE A1 USE-2 OR PV-WIRE B1 D E ONDUIT SIZE NON-OMBINED STRINGS ONDUTOR/ONDUIT SHEDULE (IF APPLIABLE) DESRIPTION AND ONDUTOR NUMBER OF ONDUIT/ABLE TAG ONDUIT SIZE ONDUTOR TYPE SIZE ONDUTORS TYPE A2 USE-2 OR PV-WIRE B2

Solar PV Standard Plan Simplified entral/string Inverter Systems for One- and Two-Family Dwellings Supplemental alculation Sheets for Inverter #2 (Only include if second inverter is used) D Information: Module Manufacturer: Model: S2) Module V oc (from module nameplate): Volts S3) Module I sc (from module nameplate): Amps S4) Module D output power under standard test conditions (ST) = Watts (ST) S5) D Module Layout Identify each source circuit (string) for inverter 1 shown on the roof plan with a Tag (e.g., A, B, ) Number of modules per source circuit for inverter 1 Identify, by tag, which source circuits on the roof are to be paralleled (if none, put N/A) ombiner 1: ombiner 2: Total number of source circuits for inverter 1: S6) Are D/D onverters used? Yes No If No, skip to STEP#S7. If Yes, enter info below. D/D onverter Model #: Max D Output urrent: Amps Max # of D/D onverters in a source circuit: D/D onverter Max D Input Voltage: Volts Max D Output Voltage: Volts D/D onverter Max D Input Power: Watts

S7) Max. System D Voltage Use A1 or A2 for systems without D/D converters, and B1 or B2 with D/D converters. A1. Module V O (STEP S2) = x # in series (STEP S5) x 1.12 (If -1 T L -5, STEP S1) = V A2. Module V O (STEP S2) = x # in series (STEP S5) x 1.14 (If -6 T L -10, STEP S1) = V Table 1. Maximum Number of PV Modules in Series Based on Module Rated VO for 600 Vdc Rated Equipment (E 690.7) Max. Rated Module VO (*1.12) (Volts) Max. Rated Module VO (*1.14) (Volts) 29.76 31.51 33.48 35.71 38.27 41.21 44.64 48.70 53.57 59.52 66.96 76.53 89.29 29.24 30.96 32.89 35.09 37.59 40.49 43.86 47.85 52.63 58.48 65.79 75.19 87.72 Max # of Modules for 600 Vdc 18 17 16 15 14 13 12 11 10 9 8 7 6 Use for D/D converters. The value calculated below must be less than D/D converter max D input voltage (STEP #S6). B1. Module V O (STEP#S2) x # of modules per converter (STEP S6) x 1.12 (If -1 T L -5, STEP S1) = V B2. Module V O (STEP#S2) x # of modules per converter (STEP S6) x 1.14 (If -6 T L -10, STEP S1) = V Table 2. Largest Module VO for Single-Module D/D onverter onfigurations (With 80V AFI ap) (E 690.7 and 690.11) Max. Rated Module VO (*1.12) (Volts) Max. Rated Module VO (*1.14) (Volts) D/D onverter Max D Input (STEP #6) (Volts) 30.4 33.0 35.7 38.4 41.1 43.8 46.4 49.1 51.8 54.5 57.1 59.8 62.5 65.2 67.9 70.5 29.8 32.5 35.1 37.7 40.4 43.0 45.6 48.2 50.9 53.5 56.1 58.8 61.4 64.0 66.7 69.3 34 37 40 43 46 49 52 55 58 61 64 67 70 73 76 79 S8) Maximum System D Voltage from D/D onverters to Inverter Only required if Yes in STEP S6 Maximum System D Voltage = Volts S9) Maximum Source ircuit urrent Is Module IS below 9.6 Amps (STEP S3)? Yes No (if No, use omprehensive Standard Plan) S10) Sizing Source ircuit onductors: Source ircuit onductor Size = Min. #10 AWG copper conductor, 90 wet (USE-2, PV Wire, XHHW-2, THWN-2, RHW-2) For up to 8 conductors in roof-mounted conduit exposed to sunlight at least ½ from the roof covering (E 310) Note: For over 8 conductors in the conduit or mounting height of lower than ½ from the roof, use omprehensive Plan. S11) Are PV source circuits combined prior to the inverter? Yes No If No, use Single Line Diagram 1 with Single Line Diagram 3 and proceed to STEP S13. If Yes, use Single Line Diagram 2 with Single Line Diagram 4 and proceed to STEP S12. Is source circuit OPD required? Yes No Source circuit OPD size (if needed): 15 Amps S12) Sizing PV Output ircuit onductors If a ombiner box will NOT be used from [STEP#S11], Output ircuit onductor Size = Min. #6 AWG copper conductor S13) Inverter D Disconnect Does the inverter have an integrated D disconnect? Yes No If yes, proceed to STEP S14. If No, the external D disconnect to be installed is rated for Amps (D) and Volts (D)

S14) Inverter information: Manufacturer: Model: Max. ontinuous A Output urrent Rating: Amps Integrated D Arc-Fault ircuit Protection? Yes No (If No is selected, omprehensive Standard Plan) Grounded or Ungrounded System: GROUNDED UNGROUNDED A Information: S15) Sizing Inverter Output ircuit onductors and OPD: Inverter Output OPD rating = Amps (Table 3) Inverter Output ircuit onductor Size = AWG (Table 3) Table 3. Minimum Inverter Output OPD and ircuit onductor Size Inverter ontinuous Output urrent Rating (Amps) (STEP 14) 12 16 20 24 28 32 36 40 48 Minimum OPD Size (Amps) 15 20 25 30 35 40 45 50 60 Minimum onductor Size (AWG, 75, opper) 14 12 10 10 8 8 6 6 6 Load enter alculations (Omit if a load center will not be installed for PV OPDs) S20) Load enter Output: alculate the sum of the maximum A outputs from each inverter. Inverter #1 Max ontinuous A Output urrent Rating[STEP S14] 1.25 = Amps Inverter #2 Max ontinuous A Output urrent Rating[STEP S14] 1.25 = Amps Total inverter currents connected to load center (sum of above) = Amps onductor Size: AWG Overcurrent Protection Device: Amps Load center bus bar rating: Amps The sum of the ampere ratings of overcurrent devices in circuits supplying power to a bus bar or conductor shall not exceed 120 percent of the rating of the bus bar or conductor.

Solar PV Standard Plan Simplified entral/string Inverter System for One- and Two-Family Dwellings 1 2 3 4 5 6 7 8 TAG DESRIPTION SOLAR PV MODULE / STRING D/D ONVERTERS INSTALLED? YES / NO (IF YES, STEPS 6 & 8 REQUIRED) SOURE IRUIT JUNTION BOX INSTALLED?: YES / NO SEPARATE D DISONNET INSTALLED?: YES / NO INTERNAL INVERTER D DISONNET: YES / NO ENTRAL INVERTER *SEPARATE A DISONNET INSTALLED?: YES / NO TO LOAD ENTER ON LINE DIAGRAM 1 * onsult with your local AHJ and /or Utility SINGLE-LINE DIAGRAM #3 ADDITIONAL INVERTER FOR DIAGRAM #1 INVERTER # 2 HEK A BOX FOR WHETHER SYSTEM IS GROUNDED OR UNGROUNDED: GROUNDED (INLUDE GE) UNGROUNDED FOR UNGROUNDED SYSTEMS: - D OPD MUST DISONNET BOTH ONDUTORS OF EAH SOURE IRUIT - UNGROUNDED ONDUTORS MUST BE IDENTIFIED PER 210.5(). WHITE-FINISHED ONDUTORS ARE NOT PERMITTED. 1 2 3 4 MODULES 5 6 7 MODULES MODULES MODULES A D 8 A B IF D/D ONVERTERS ARE USED, HEK THE BOX BELOW THE ORRESPONDING ONFIGURATION D/D ONVERTERS + - + - INVERTER D/D ONVERTERS + - + - INVERTER ONDUTOR/ONDUIT SHEDULE TAG DESRIPTION AND ONDUTOR TYPE ONDUTOR NUMBER OF SIZE ONDUTORS A USE-2 OR PV-WIRE EG/EG: B EG/EG: EG/EG: ONDUIT/ABLE TYPE ONDUIT SIZE ENTER N/A WHERE SUITABLE FOR WHEN NOT USING ONDUIT OR ABLE AS PERMITTED BY ODE + - PARALLEL D/D ONVERTERS ON ONE SOURE IRUIT (FIXED UNIT VOLTAGE D/D ONVERTERS) + - D/D ONVERTERS ARE ALL RUN IN SERIES (FIXED SOURE IRUIT VOLTAGE D/D ONVERTERS)

Solar PV Standard Plan Simplified entral/string Inverter System for One- and Two-Family Dwellings OMBINER ONDUTOR/ONDUIT SHEDULE DESRIPTION AND ONDUTOR NUMBER OF ONDUIT/ABLE TAG ONDUTOR TYPE SIZE ONDUTORS TYPE A1 USE-2 OR PV-WIRE B1 D ONDUIT SIZE NON-OMBINED STRINGS ONDUTOR/ONDUIT SHEDULE (IF APPLIABLE) DESRIPTION AND ONDUTOR NUMBER OF ONDUIT/ABLE TAG ONDUIT SIZE ONDUTOR TYPE SIZE ONDUTORS TYPE A2 USE-2 OR PV-WIRE B2 D/D ONVERTERS

SOLAR PV STANDAR PLAN Roof Layout Diagram for One- and Two-Family Dwellings Items required: roof layout of all panels, modules, clear access pathways and approximate locations of electrical disconnecting means and roof access points.