Intrinsically Safe Miniature Solenoid Valves

Similar documents
For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Electro-pneumatic control valves

ELECTRO-PNEUMATIC CONTROL VALVES

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

SOLENOID VALVES AND PNEUMATIC VALVES

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body

General characteristics Operating fluid Compressed air or inert gas Conditions of use Operating pressure 30 to 20 PSI (2 to 8 bars). Fluid: Filtered a

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Series PD directly operated solenoid valves

3/2-5/2 ports / positions

Series P directly operated solenoid valves

Valves and Solenoid valves Series E 2/

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

Series PD directly operated solenoid valves

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SOLENOID VALVES AND PNEUMATIC VALVES

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

PS1 Modular Interface Valve

2/2-way, 3/2-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 and G1/8 - cartridge ø4

VALVES SERIES 70, SOLENOID/PNEUMATIC

Compact design suitable for use in reduced mounting space. CONTROL > Directly operated solenoid valves Series PN GENERAL DATA

Valves and Solenoid valves Series 7

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Direct-acting 3/2 way plunger valve

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

Valve: brass guiding tube plunger and core made by a magnetic stainless steel specially designed for solenoid applications polyester valve body

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

SPOOL VALVE. solenoid air operated 3/2 G 1/4. SPECIFICATIONS : air or neutral gas, filtered, lubricated or not PORTS : G 1/4 CONSTRUCTION

3/2-way Rocker Solenoid Valve for pneumatic systems

HERION SERIES Indirect solenoid actuated soft seal

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

Standard valves to ISO Product range overview

Our policy is one of continued research and development. We therefore reserve the right

Pneumatics products Logic elements, Position / Detectors Electro-pneumatic valves

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

97100 NAMUR. Technical data

Data Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

SKINNER Intrinsically Safe Series Four-Way

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4.

Pneumatic. PVD Ceramic Valves

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Explosion-Protected Pressure Switches

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

2/2 Pressure operated valves

Pressure switches - Vacuum

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

COILS, CONNECTORS, SOLENOID VALVES

Remote Process Actuation Control System AirLINE - Siemens ET 200S

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Position detectors.

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

System 6. Solenoid Coils Armature Assemblies Valve Systems

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

Pressure switch hex 27

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Chapter 11: Valves and Actuators with the NAMUR-interface

3-Way Solenoid Valve - Direct Acting

Pilot operated solenoid valves for pneumatic actuators

Pilot operated solenoid valves for pneumatic actuators

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Lockable isolation 3/2-way valves Series MX 3/

Solenoid valves VZWM-L

Solenoid valves VZWM-L, NPT

Solenoid valves VZWM-L

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE. Model/Ref:

Pneumatically actuated valves 3/2 NC become NO when the supply is on connection 3.

AirLINE and AirLINE Quick electrical/pneumatic Automation System

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

14,5 PSC PSP PSR. INTEGRATED SUB-BASE MANIFOLD valve with no subbase

Transcription:

Intrinsically Safe Miniature Solenoid Valves 5 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com 5/6

Intrinsically safe miniature solenoid valves EEx ia T6 approval no. 9 C 604X For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nominal Supply voltage (barrier output or interface) 2 Vdc 0.70 W 8 59 04 8 59 4 8 59 64 between 5 and 8 Vdc inc. U nominal Supply voltage (barrier output or interface) 24 Vdc 0.70 W 8 59 05 8 59 5 8 59 65 between 2 and 28 Vdc inc. Function Versions Symbols Without manual override With manual override /2 NC /2 NC impulse /2 NC latched (/4 turn) 2 2 2 Characteristics Permitted fluids filtered 0 µ, lubricated (ASTM2) or not Operating pressure bars Orifice diameter mm Flow at 6 bars NL/min Flow coefficient KV Temperature operating C fluid C Switching time ms Mechanical life operations Construction Stainless steel, brass NBR, PA 66 Weight g Duty factor Insulation class IEC 85 Degree of protection with connector 8 56 082 (IEC 529) (see page 5/67) with subbases 8 5.../8 57... (see page 5/66) Pneumatic connections Geometry of footprint via miniature pilot sub base 8 54 0 On modules 8 5 00/200/600 8 56 00/200 Electrical connections 2 spade terminals on coil 90 rotatable via connector 8 56 082 90 rotatable via miniature pilot sub base types 8 5 /8 54 via miniature sub base types 8 5 /8 57 air or inert gases 7 0.5 2 0.2 0 + 50 0 + 0 8 to 5.5 x 0 7 5 00% ED F IP 65 see page 5/5 see page 5/5 see page 5/67 see page 5/66 air or inert gases 7 0.5 2 0.2 0 + 50 0 + 0 8 to 5.5 x 0 7 5 00% ED F IP 65 see page 5/5 see page 5/5 see page 5/67 see page 5/66 air or inert gases 7 0.5 2 0.2 0 + 50 0 + 0 8 to 5.5 x 0 7 5 00% ED F IP 65 see page 5/5 see page 5/5 see page 5/67 see page 5/66 Dimensions 9.4 Locating pin Ø 4 ext. ht. 5 + 2 spade terminals 2.8x0.5 4 8 59 04 8 59 05 26 5 6 8 59 4 8 59 5 26 4 Other information 2 8 59 64 8 59 65 Manual override Note: Our intrinsically safe miniature solenoid valves have a locating pin which prevents their mounting on our standard subbases. They must be used only with our subbases approved to EEx ia T6 as shown on page 6/6. To achieve EEx ia T6 when using a plug type connector, only our connector 8 56 082 (approved for use with our miniature solenoid valves 8 59...) must be used. Footprint 6 min. 9 min. 2 x M 6H depth 6 Solenoid valve projects on this side 7 min. Adjacent side of footprint when valves mounted in bank Standard products 9,7,8 2,4,8 To order, specify : 7,5 min. 7,5 min. 2 or Ø.6 min 2 max Part number Example : Intrinsically safe miniature solenoid valve 8 59 04 5/64 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com

General information Low consumption (0.7W), CROUZET /2 miniature solenoid valves comply with European Standards EN 5004 and EN 50020 relating to equipment operating in potentially explosive atmospheres. These intrinsically safe products are recommended for the chemical, petrochemical, gas and mining industries, etc. Important : These intrinsically safe miniature solenoid valves must be individually connected to an approved safety barrier. Placed in a safe zone, these barriers make it possible to supply intrinsically safe miniature solenoid valves installed in a hazardous zone. Hazardous Zone Non Hazardous Zone Category ia Ignition must not be provoked during normal operation, nor in the presence of a single fault, nor in the presence of a combination of faults. Group II Electrical apparatus for places with a potentially explosive atmosphere, other than mines susceptible to firedamp. EEx ia T6 Temperature class T6 Maximum surface temperature = 85 C C (gas group) More severe subdivision including hydrogen, acetylene & carbon bisulphide. 2 + I max. U supply Intrinsically safe miniature solenoid valve Safety barrier or interface Safety description (to approval no. 9 C 604 X) 8 59 04 /4 8 59 05 /5 U source EEx 8 V 28 V I max. / coil 74 ma 7 ma U supply = source of intrinsically safe supply to the miniature solenoid valve. I max. / coil = maximum current across the coil. R + The electrical connection between the safety barrier (or interface) and the miniature solenoid valve can be made with ordinary wires or cables. The inductance of the connecting line between the safety barrier and the solenoid valve must be less than 0.5 mh. Recommended barriers and interfaces These CROUZET recommended safety barriers and interfaces can be obtained from the manufacturers indicated below. When ordering, specify that they are to be used to supply miniature solenoid valves (type 8 59) EEx ia T6, no. 9.C604 X. For 2 Vdc miniature solenoid valves part numbers : 8 59 04 / 8 59 4 Manufacturer Barrier Interface GEORGIN BZC /00//79 MEASUREMENT TECHNOLOGY LTD STAHL MTL 75 + 9004/06805000 AVB ICS 000 945/200 Approval laboratory BVS Gas group Authorized zones zones and 2 zones and 2 V supply barrier / interface 2 Vdc +/ 0% 220 Vac +/ 0% 2 Vdc +0% 5% 2 Vdc +0% 5% 24 Vdc +0% 5% For 24 Vdc miniature solenoid valves part numbers : 8 59 05 / 8 59 5 Manufacturer Barrier Interface GEORGIN BZC 24/6//4A MEASUREMENT TECHNOLOGY LTD PEPPERL & FUCHS STAHL A PUISSANCE MTL 728 + MTL 708 + Z 428 EX 9004/028002500 AVB 09 MTL 224 MTL 02 KHDISD/EX4890A ICS 000 945/2020 ELVA5/0+A20 Approval laboratory BVS Gas group Authorized zones zones and 2 zones and 2 V supply barrier / interface 24 Vdc +/ 0% 220 Vac +/ 0% 20 to 26.6 Vdc 2 to 5 Vdc 80 to 260 Vac 20 to 5 Vdc 20 to 26.5 Vdc 20 to 5 Vdc 20 to 28 Vdc 20 to 0 Vdc 20 V 50 Hz general power supply + 24 Vdc control 5 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com 5/65

Subbases for intrinsically safe miniature solenoid valves EEx ia approval no. 9 C 604X Part numbers Subbases for tube for use with : Ø ext (mm) Miniature solenoid valves intermediate subbase 4 8 59... end bases 4 Miniature control valves intermediate subbase, 4 8 5 075 8 5... width 7.5 6 8 5 076 Miniature control valves intermediate subbase, 4 8 57 06 8 56... width 5 6 8 57 206 Subbase width mm subbase 7.5 subbase 5 Function connections miniature control valves 8 5 00 /200 /600 miniature control valves 8 56 00 /200 Characteristics Pneumatic miniature solenoid valves and electrical 8 59 04 /05 /4 /5 footprint 2 footprints footprint Permitted fluids lubricated (ASTM2) or not air or inert gases air or inert gases Operating pressure bars 0 to 8 0 to 8 Temperature operating C 0 to +50 0 to +50 of fluid C 0 to +0 0 to +0 Subbase fixing by clip by end bases 8 5 0 8 5 0 Rail mounting by rail EN 50022 width 5 mm Construction NBR, PA 66 fireproof, brass Integral pressure indicator Weight g 55 05 Degree of protection Pneumatic connections Port function common supply Port function common exhaust Port 2 function miniature solenoid valve 859... miniature control valve 8 5 200 /600 output at rest (NO) output at rest (NO) Port "2" function miniature control valve 8 5 200 /600 miniature control valve 8 56... output at rest (NO) output at rest (NO) Port 4 function miniature control valve 8 5 00 /200 miniature control valve 8 56... output operating(nc) output operating(nc) output operating(nc) Port "4" function miniature control valve 8 5 00 /200 output operating(nc) Integral pushin fittings (NFE 4900) Electrical connections Integral electrical connections number 2 Screw clamp clamping capacity : terminals mm 2 number 2 (A and A2) 2 (A and A2) Dimensions Associable subbases for miniature control valves EEx 8 5 and 8 56 Pair of end bases 8 5 0 (see page 5/54 general catalogue) Electrical connections Visual indicator 8 5 052 (see page 5/67) 2 4 6 5 7,5 7,5 5 7,5 80 2,5 Miniature solenoid valve EEx 8 59 (see page 5/64) Miniature control valve 8 5 or 5 56 (see page 5/5) ø4 ø6 Mounted on Ω rail l.5 mm (EN 50022) Pushin connection for semirigid tubing Ø 4 mm (NFE 4900) Other information Note : Subbases 8 5 075 / 076 and 8 57 06 / 206 must be used with end bases 8 5 0 and intermediate module 8 5 00 (if required). 5/66 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com

EEx ia T 6 accessories General information CROUZET intrinsically safe subbases conform to European Standards EN 5004 and EN 50020 relating to equipment operating in potentially explosive atmospheres. These subbases must be individually connected to an approved safety barrier. (See recommended barriers & interfaces on page 5/65.) Part numbers Visual indicator 24 V 5060 Hz c 8 5 052 Connector for solenoid valve Adaptor subbase for CNOMO 058 footprint Symbol 8 56 082 79 45 569 Hazardous Zone A2 A Subbase for intrinsically safe miniature solenoid valve A = terminal A2 = + terminal Non Hazardous Zone R + Safety barrier Distinctive features of the EEx subbase : No integral electrical common No provision for earth pin There is provision for the locating pin for each intrinsically safe miniature solenoid valve 8 59. Note : In order to satisfy the safety conditions of EEx ia T6 our intrinsically safe miniature solenoid valves 8 59... must be used ONLY with the subbases shown on page 5/66. These subbases cannot be used for mounting our standard range of 8 59... miniature solenoid valves (non approved). Characteristics Mounts between pilot solenoid valve and subbase Supplied in multiples Packet of 0 pieces Fixing Weight Connection of 5 of 0 g 6 8 5 052 8 5 055 Dimensions 8 5 052 79 45 569 29 28 5 Note : When using LED indicators only our indicator 8 5 052 (approved for use with our miniature solenoid valves 8 59...) should be used to achieve EEx ia T6. 0 Connector ref. 8 56 082 (rotatable in 90 steps) Miniature solenoid valve 8 59 see page 5/64 CNOMO footprint E 06620N for mounting miniature solenoid valve 8 59 Mounting on CNOMO 060580 / NFE 49066 footprint Control 2 signal t Earth (4) 4,7 52 max. 2 screws M4x0 8 7 max. 52 max. 5 2 2 Fixing onto CNOMO 060580/NFE 49066 footprint by 2 cap screws M4x0 (NFE 2527) 4 25 Note : When using plug connectors, only our connectors 8 56 082 (approved for use with our miniature solenoid valves 8 59...) should be used to achieve EEx ia T6. Standard products Part number To order, specify : Example : Subbase for miniature solenoid valve 8 54 66 5 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com 5/67

Intrinsically safe pressure switches EEx ia T6 approval no. 9 C 605X Conform to the Low Voltage Directive Can be used without enclosure according to IEC 664 pollution group III Part numbers 8 5 50 Fixing DIN rail 5 mm EN 50022 Function Version Symbol control manual override pressure with Characteristics Permitted fluids air, inert gases and liquids Adjustable switching pressure (* set at 0.) bar Hysteresis at bar at 2 bars at 4 bars at 6 bars Pressure indicator Temperature operating C of fluid C Mechanical life operations Maximum voltage V Construction POM, brass, AU4G Weight g Degree of protection IEC 529 Pneumatic connections Pushin connection for semirigid tubing Ø 4 mm (NFE 4900) Connection Tapped holes /8 BSP Electrical connections Integral electrical connections Screw terminals number Wire crosssection mm 2 Terminal capacity mm 2 Dimensions 2 to 8 0.5 0.6 0.8 0 + 50 0 + 0 0 6 60 Vdc 48 (24) 0.75 8 5 50 Electrical connection Adjustment of switching pressure Manual override Pneumatic indicator Pilot signal Other information On request : Low pressure version from 0.2 to.2 bars Vacuum version adjustable from 0. to bar Standard products To order, specify : Reference Example : Intrinsically safe pressure switches 8 5 50 5/68 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com

General information CROUZET intrinsically safe pressure switches conform to European Standards EN 5004 and EN50020 relating to equipment operating in potentially explosive atmospheres. These intrinsically safe products are recommended for the chemical, petrochemical, gas and mining industries, etc. These intrinsically safe pressure switches must be individually connected to an approved safety barrier. Placed in a safe zone, these safety barriers make it possible to supply intrinsically safe pressure switches installed in a hazardous zone. Hazardous Zone Non Hazardous Zone 4 2 a U < 60 V R + Intrinsically safe pressure switch Safety barrier or interface = common 2 = NC contact 4 = NO contact The electrical connection between the safety barrier (or interface) and the pressure switch can be made with ordinary wires or cables. The maximum intrinsically safe supply voltage must not exceed 60V. Recommended barriers and interfaces These CROUZET recommended safety barriers and interfaces can be obtained from the manufacturers indicated below. Specify when ordering that they are to be used to supply intrinsically safe pressure switches (type 8 5) EEx ia T6, no. 9.C605 X. For CROUZET intrinsically safe pressure switches Manufacturer Barrier GEORGIN BZC 24/20//275 MEASUREMENT TECHNOLOGY LTD PEPPERL & FUCHS GB LTD STAHL MTL 787 S + MTL 707 + Z 428 EX 900/02520604 Interface RD RD 2 MTL 220 B MTL 0 MTL 40 KHD2RW/EX KHA6RW/EX ICS PAK 9250 ICS 000 920/04..24 Approval laboratory Gas Group Authorised zones 5 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com 5/69

Intrinsically safe electropneumatic miniature control valves EEx ia T6 Mounting Connectors EEx ia T6 When using plug connectors, only our connectors 8 56 082 (which have been approved for use with our miniature solenoid valves 8 59...) should be used, to comply with EEx ia T6. Cabinet Machine Miniature solenoid valves EEx ia T6 Indicators EEx ia T6 When using LED indicators, only our indicators 8 5 052 (which have been approved for use with our miniature solenoid valves 8 59...) should be used, to comply with EEx ia T6. Valve modules Poppet /2 monostable (7.5 mm) 4/2 monostable (7.5 mm) Slide valve 4/2 bistable (5 mm) 4/2 monostable springreturn (5 mm) Subbases EEx ia T6 For miniature solenoid valves For valve modules For valve modules Associable Single Double Individual Complete product EEx ia T6 5/70 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com