Safe and secure power distribution Arc fault protection solutions

Similar documents
Safe and secure power distribution Arc fault protection solutions

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Modular Standardized Electrical and Control Solutions for Fast Track Projects

ZX2 Gas-insulated medium voltage switchgear

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

ZX-Family Gas-insulated medium voltage switchgear

When grids get smart ABB your partner for developing Smart Grids solutions

SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE

MNS PDUpro Intelligent power distribution unit

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Ultra Fast Earthing Switch UFES retrofit Overview

ZX-Family Gas-insulated medium voltage switchgear

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

TRANSFORMER SERVICE. ABB Ability inspection for transformers TXplore Oil-filled transformer internal inspection service

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

Life cycle services for protection and control relays Full support from start to finish

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Microgrid solutions Delivering resilient power anywhere at any time

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Grounding Of Standby & Emergency Power Systems

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

Gas-insulated medium-voltage switchgear. For marine and offshore applications. Answers for energy.

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ZX2.2 Gas-insulated medium voltage switchgear

Operational Experience with Startup Optimization for Steam Boilers. E.ON s Staudinger, Heyden, Ingolstadt und Zolling Power Plants

Electrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance

Low and medium voltage service. Power Care Customer Support Agreements

voltage switchgear ZX ABB ZX Family 1

Safe, fast HV circuit breaker testing with DualGround technology

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

Exceeding the standards with MNS

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

UniSec Maintenance solutions

Stora Enso Helping Stora Enso achieve big energy savings

Brochure. Arc Guard System TVOC-2 A protection device for reliable safety

Low Voltage Systems MNS and MNS is PowerCenter

Arc-Flash Mitigation Technologies. Dennis Balickie

ABB FACTS Customer Service. FACTS Care Upgrades

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Low Voltage Switchgear MNS with Integrated VSD

Brochure. Synchronous generators for steam and gas turbines Proven generators reliable power

Totally Integrated Power. A reliable all-rounder. Gas-insulated medium-voltage switchgear 8DJH 36.

ABB Low voltage systems MNS Platform

Overview Overvoltage protection

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Unit C of the Scholven Power Plant Automated with System 800xA

One-Fit,UFES, Reyrolle LM

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Fault management for grid automation Advanced fault location solution

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

Service and Rehabilitation Electrical Power Systems

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

EMPAC Metal enclosed capacitor bank for wind applications

CRITICAL ISSUES DOWNTOWN CONTINGENCY PORTFOLIO

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Substation Concepts for the Future

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

B kv T&D GAS INSULATED SWITCHGEAR

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Short form catalogue Motor protection and control Manual motor starters

Mechanical, Electrical, Technology Engineering Firm

Xiria the smart solution

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Multi-megawatt power protection at medium voltage

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

Breaker-failure protection RAICA

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Western Alberta Transmission Line (WATL) HVDC Project

Not all Low Voltage Switchgear is created equal

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

ABB in primary aluminium From mine to market

Arc flash hazard mitigation

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

Retrofitting unlocks potential

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

Air-insulated switchgear UniGear type ZS1

Manual motor starters Overview and benefits

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Galapagos San Cristobal Wind Project. VOLT/VAR Optimization Report. Prepared by the General Secretariat

Xiria the smart solution

DESIGN AND RETROFITTING OF LOW VOLTAGE AIR CIRCUIT BREAKERS.

XIRIA Green, Smart, Compact solution

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ABB life cycle services Uninterruptible power supplies

Product information. ECOSS Electronic compact starter for wound rotor drives

Transforming Transforming Advanced transformer control and monitoring with TEC

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

Technical information No. 01. IT systems. The basis for reliable power supply

Raising the bar. UHV switchgear and components

Transcription:

Safe and secure power distribution Arc fault protection solutions

2 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS The Noble Art of Switchgear Arc Fault Protection Power system operation fault statistics reveal that a vast majority of the switchgear arc faults are caused by incorrect human actions or by aging network equipment. One way of reducing human-related or equipment-associated fault risks is to focus investments on technological solutions that enhance the operating environment. The basic necessity of a switchgear arc fault protection system can be investigated from the probability aspect of arcing faults or from the aspect of their adverse effects. The perspective of investigation usually focuses on staff safety and security and on asset management. Both sectors are of essential business importance for network companies as well as industrial enterprises.

3

4 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS Impacts of power system arc faults Electric arcs may cause instant and severe burns to persons happening to stay close to the fault, when it arises. Typically, this is the case if the arc incident is caused by an incorrect switchgear operation. The arc flash easily causes a fire, which, in addition to the immediate damage, also creates fire gases and consequential damage due to smoke and stain. The fire gases of burning electrical devices are particularly dangerous for people residing in the same area. The effective life-time of distribution network equipment is typically in the range of decades. Network companies and industrial enterprises aim at maximizing the operational life-time of their equipment and to reach the financial goals. Equipment fault proneness a function of time As the life-time of electrical devices extends over decades, changes constantly occur in their operational proximity and the customer base they serve. The legislation and regulations may also change over the operational life-time of the equipment. For instance, a switchgear system, which originally was intended for limited supply of power to a small population centre, may later have to supply power to a shopping mall serving thousands of customers seven days a week. The role of the switchgear system may also have become more critical. Possible power outages may cause considerable economic losses to the customers. Furthermore, the loading of the switchgear has grown and for this reason a second power transformer has been installed in parallel with the first one. In peak load situations the transformers can be run in parallel, which also causes the short circuit power to increase. At the same time the arc fault energy and the resulting damage in case of an arc fault increase.

5 Changing working manners pose risks In power systems the maintenance need of the primary system equipment is generally small. Therefore the equipment maintenance intervals tend to be fairly long. There is also just a limited need to perform local control of such components as breakers and switches. Under these circumstances the personnel will not obtain the necessary experience to work with power system components. The personnel s lack of experience will pose an increased risk of making mistakes during maintenance work and fault clearance activities. The probability of accidental arc faults is also increased by changes in the utility s work staff. The fact that when the current maintenance people of the network companies reach the age of retirement, the familiarity of the new staff with the network systems decreases on a local level. In addition, the need of the network companies to outsource maintenance functions further add to the risks of human errors. Over the years the working conditions of the devices degrade. The aging and degeneration of protective structures and auxiliary furnishing expose the equipment to dust, moisture, temperature variations and rodents. The condition of the switchgear system is also affected by stress factors and excessive loading, which may cause untightening of joints and degeneration of bushings. By investing in protective equipment such as arc fault protection, the safety and security of the switchgear system can be enhanced. The investment done in protection equipment will also extend the life-time of the switchgear installation, postponing possible investments in new switchgear or even substations to a later date.

6 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS Milliseconds that count Time is a critical parameter in reducing the effects of arc faults, as the arc incident energy rapidly increases by time. An arc fault lasting for 500 ms may cause severe damage to the installation. If the arc flashes for less than 100 ms the damage is often limited, and if the arc is extinguished in less than, say 4 ms the damage will be insignificant. Operating time The operating time of the protection is the prime factor with regard to the elimination of the adverse effects of arc faults, seen not only from the point of view of staff safety and security, but also from the switchgear and environmental point of view. When the selectivity of the protection system is based on time grading, the protection operating time at switchgear faults is typically hundreds of milliseconds. With a separate busbar protection system a total operating time of about 100 milliseconds can be achieved, much depending on the speed of the circuit breaker. By installing an arc fault protection system the operating time can be halved. This means that the switchgear damage is reduced to a tolerable level, typically limited to a single switchgear cubicle. A total operating time of a couple of milliseconds can be reached by using a separate arc flash eliminator for earthing the busbar. This procedure causes the electric arc to die out immediately at the moment of earthing. Due to the ultra-fast earthing function no significant pressure increase will develop in the switchgear system and no significant damage will arise. Arc fault damage as a function of the arc fault energy and the arc fault impact time. Arc fault energy [ka 2 s] 300 Steel fire Copper fire 200 Cable fire 100 200 Fault impact time [ms]

7 Selectivity In conventional arc fault protection solutions electrical faults in the cable terminations of outgoing feeders are typically handled by the busbar protection system, although these faults could be eliminated using the circuit breaker of the faulted outgoing feeder. Modern arc fault protection systems are not restricted by lack of selectivity. When an arc fault protection system is used the interruption caused by a cable termination fault affects only the consumer loads supplied by the faulted cable feeder. In cable termination faults the whole substation will normally be blacked out resulting in a much more widespread interruption of the power supply. An earth-fault rapidly tends to develop into an arcing fault, because the operating time of the basic earth-fault protection system is usually relatively long. Arc fault protection systems are also capable of detecting arcing faults between the phase conductors and the switchgear frame. Even in phase-to-frame faults the operating time of the arc fault protection system is as short as for inter-phase arc faults. Redundancy A reliable function of the protection system is of crucial importance for critical network nodes. These cases justify the implementation of a redundant protection system, fully independent of the basic protection system. An autonomous arc fault protection system perfectly fulfils this requirement, as its function is based on a different physical phenomenon than conventional protection solutions and on a dedicated technology.

8 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS An ABB solution for any application ABB s arc fault protection systems provide appropriate solutions for both green field projects and retrofit installations. The arc fault protection introduction tool presents a product portfolio diagram mapping alternative strategies and solutions. Arc fault probability High Moderate Significant 615 and 620 series with integrated arc fault protection REA REA+ UFES Switchgear renewal Low Maintenence work Minor Moderate Significant Impact of arc faults Serious From the comprehensive and compatible arc fault protection system assortment the customers can choose their solutions according to their own preferences. An already existing main protection scheme can be completed with an independent arc fault protection system or it can be upgraded by using protection relays with integrated arc fault protection in the basic functionality set-up. The ABB arc fault protection systems provide detection and isolation of arcing faults starting from either earth faults or from short circuits. The selection of the appropriate arc fault protection system preferably starts with a risk mapping, which, on one hand, focuses on the probability of the development of an arc fault, and on the other hand, on the effects of a possible arc fault. The probability of the development of arc faults is especially related to human factors but also to the structure and the state of the switchgear system, the physical stress imposed on the system and the environmental stress on the system. In the evaluation of the consequences of arc faults the implications on the staff safety and security must be studied, as also the impacts on the power distribution, the buildings and the rest of the proximity. Furthermore, industrial customers may suffer great losses of production due to arc faults. The volume and type of investments needed to enhance the safety and security of the power system, and the reliability of the power distribution can be studied by performing risk analyses. In the process of choosing an arc fault protection solution for an existing switchgear system, its expected remaining life-time is of significant importance. There are two alternative strategies to choose from. Either the operational life-time of the switchgear system can be prolonged by additional investments, or the whole switchgear system can be renewed. In modern switchgear systems the probability of damage due to arc faults is comparatively low. Despite of that, it can, of technical and assembly reasons, be recommendable to provide the switchgear panel with a system-wide supervision solution serving for the whole operational life-cycle of the switchgear system. Please contact your local ABB product or service sales in order to perform a risk mapping for an arc incidence in your power system installation.

9 The 615 and 620 series protection relays with integrated arc fault protection are adapted to switchgear systems, which are important for the distribution network and its customers. In these systems the consequences of arc faults can be considerable to the personnel and the surrounding, although the probability of an arc fault is low. Due to the integration of arc fault protection into the basic protection set-up the 615 series relays present a universal solution. The operating time including detection and submission of a trip signal from the 615 series protection relays is typically 7 10 ms. The operating time of the circuit breaker (30 60 ms) will additionally delay the arc fault extinguishing. The REA arc fault protection system suits switchgear systems, where the damage to the proximity has been limited by means of constructional measures, but which are highly critical from the point of view of the distribution network and the customers. Switchgear systems having already served their time are examples of installations, in which REA arc fault protection easily can be installed afterwards. The REA arc fault protection system is also a perfect match for replenishing the protection system of double busbar switchgear systems. The operating time including fault detection and submission of a trip signal from the REA arc fault protection system is <2.5 ms. The operating time of the circuit breaker (30 60 ms) will additionally delay the arc fault extinguishing. UFES (Ultra-Fast Earthing Switch) is suited for switchgear systems, where staff safety and security, and switchgear arc fault and fire damage are crucial. Switchgear systems of shopping malls, buildings, mining industry, off-shore applications and other limitedsize switchgear systems are typical examples of this category. The fault detection and elimination time of an UFES arc fault elimination solution is typically <4 ms. REA and UFES as an integrated solution meets switchgear systems, where staff safety and security is of great significance and the switchgear system is of utmost importance for the distribution network and its customers. Switchgear systems of this type are usually feeding hospitals, traffic nodes and process industry facilities. The typical operating time of the REA and UFES solution for detecting and eliminating an arc fault is <4 ms.

10 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS

11 Our references speak for themselves Over the past decade thousands of ABB arc fault protection systems have been delivered to over 40 countries worldwide. Systems have been installed in distribution systems of power utilities and heavy industry production facilities, such as paper, steel, petrochemical and chemical industry plants. Arc fault protection systems have also been integrated in the power distribution systems of airports and harbours and in power distribution systems of commercial and society service facilities like shopping centres, water works and sewage treatment plants, also including marine and off-shore installations.

12 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS Helsinki International Airport, Finland Aviaenergia Oy supplies secured power to the critical functions of the Helsinki Airport, including air traffic control and surveillance functions. In line with the company s strategic decision also the recently erected new 20 kv substation supplying power to the top ranking Helsinki airport was equipped with ABB arc fault protection of the REA product line. Due to the location of the substation at the Helsinki airport, safety and security measures and possible outages caused by faults must be seen as part of the stringent airport safety program.

13 Detmarovice Power Plant, Czech Republic The Detmarovice Power Plant was built 1972 through 1976, and with its capacity of 800 MW it is the largest coal-fired power plant in Moravia. In a modernization project the power plant had been equipped with ABB s modern REA arc fault protection. At an accident in 2002 the REA system obviously saved the lives of two workers and minimized damage to mere smoke and dust detriment. The estimated repair costs would have mounted to approx. $1.6 million USD, had the plant not been provided with arc fault protection.

14 SAFE AND SECURE POWER DISTRIBUTION ARC FAULT PROTECTION SOLUTIONS Hanover Waterworks, Stadtwerke Hannover AG, Germany Hanover s municipal utility supplies energy, water and other services to the citizens. The utility operates three waterworks providing drinking water to a total of 650,000 inhabitants in the metropolitan area of Hanover. The 50 years old switchgear system of the second largest Fuhrberg waterworks has recently been replaced by a modern switchgear system including IEC 61850 compliant REF615 feeder protection and control devices with integrated arc fault protection. Arc fault protection was a necessity, because, according to the requirement, the switchgear system had to be re-energized within half an hour after a fault-related power outage. Wacker Chemie AG, Germany Staff safety and security is of number one priority to Wacker Chemie AG and its chemical plants. In this context Wacker Chemie also needs to minimize the arc fault hazards in connection with medium voltage switchgear systems. Wacker Chemie therefore needed a solution for minimizing the effects of such hazards. ABB provided an innovative retrofit solution based on a new technology for arc elimination, the Ultra Fast Earthing Switch (UFES). The UFES system provides greatly enhanced staff safety and security during arc faults and radically minimizes arc-fault related damage.

15 Pellesmäki substation, Savon Voima Verkko Oy, Finland Staff safety and security have always been put in focus at Savon Voima Verkko. Already in the 1990 s the power utility took a decision that all new substations would be equipped with arc fault protection. The utility has also carried outupgrading projects concerning existing substations, in which ABB s REA arc fault protection systems were installed. As a network operator Savon Voima Verkko sees as its duty to assure staff safety and security, and to maintain power supply even in fault situations. Besides improving constructions, instructions and guidance it is important that risks caused by human error also are considered in the protection system of substations. As outsourcing is used to an increasing extent in substation work today, the risks related to human errors are accentuated. Yale University Medical Campus, USA The most important aspect of any electrical system is to have the best protection available to the personnel working with and on these systems. A recent installation that utilizes ABB s REA Arc Flash Protection System at the Yale University Medical Campus for both bus protection and arc flash hazard reduction experienced a bus fault resulting in an arc flash event. REA successfully detected the fault and cleared it before the traditional bus differential protection (87 function) could detect the fault and pickup. The quick response time of REA resulted in no injuries to nearby personnel and minimal damage to the switchgear.

ABB Distribution Solutions P.O. Box 699 FI-65101 VAASA, Finland Phone: +358 10 22 11 Fax: +358 10 22 41094 ABB India Limited, Distribution Automation Maneja Works Vadodara 390013, India Phone: +91 265 272 4402 Fax: +91 265 263 8922 ABB AG Oberhausener Strasse 33 DE-40472 Ratingen, Germany abb.com/mediumvoltage abb.com/substationautomation Additional information We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. Specifications subject to change without notice. 1MRS756596 REV C EN 11-2018