General spare parts. Accessories & Spare parts. Ordering information. SPB03: Battery with retrofit battery clamp (XX) Lithium 3xAA-Cell batteries

Similar documents
Terminal Boxes in Stainless Steel SLS**.T

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

ILED Aquarius Illuminated Windsock. User Manual

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Direct-acting 3/2 way plunger valve

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Metal Position Switch Series 8074

Position Switches Series 8060/2

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

SITRANS P measuring instruments for pressure

Type MR 783 Magnetic level switch

Position Switches Series 8070/2

Load disconnect switch Series 8146/5-V11

Proximity Transmitters, and Seismic Vibration Transmitters

INTERNATIONAL METAL ENGINEERING

Control Buttons / Switches for Panel Mounting Series 8003

Compact Sheet-Steel Light Fittings Series 6114/1

Assembly. Trunk IN + - S U, I U, I. Spur 1

INTERNATIONAL METAL ENGINEERING

Level limit switch Series RF 3000 Selection list

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Compact Sheet-steel Emergency Light Fitting Series 6118/1

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Leading the way in hazardous areas Features EATON

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Solenoid Valve Island Type 3965

Terminal Boxes Series 8125

Position Switches Series 8074/2

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Turbine flowmeters Series TM

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Zone 1 Linear Range - Installation Guide

Floodlight Range Installation Guide

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

HTSB system System overview

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

ABG Cable Glands Installation Procedure

Floodlight LED Series 6525

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Floodlight Series 6521/4

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Type Electronic Limit Switch

Integrated Control modules

PY, SPY; FSQC, FP; EPC; AP

Plug and Socket Devices SolConeX 16 A Series 8570

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Compact temperature switch Model TCS

CCAI, CCAIF, CCAIF..H

Spring loaded resistance thermometer

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

M-0. M-0... series control, monitoring and signalling devices. Ex e

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Cable Glands - American Series - NEC/IEC

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

ILED Dorado. User Manual

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

A good connection. International approvals.

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

ExBin-P Pressure switches 5 Pa Pa

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Battery Boxes Series 8316

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Sentronic PLUS 614 Series

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Linear Valve Electric Actuator

Compact differential pressure switch Models DC, DCC

INSTRUCTION MANUAL (ATEX / IECEx)

Emergency Light Fitting for Fluorescent Lamps Series 6009

Flameproof Alternators

Load and Motor Switches, Load-Break Switches Series 8549

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

New products Ex Equipment 2015

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INSTRUCTION MANUAL (ATEX / IECEx)

Solenoid coils VACF Type codes

Type Z & Ex pz purge and pressurization system

CYCLOPS X Purge Controller SM Version

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Linear fluorescent luminaire LED V-CG-S

Transcription:

General spare parts Lithium 3xAA-Cell batteries SPB03: Battery with retrofit battery clamp (XX) SPB02 SPC02 Retrofit instruction video SPC03: Battery with retrofit battery clamp (XI) Retrofit instruction video Batteries SPB02 PB - Lithium battery 3xAA-cell - long life time. For safe area applications (F-Series & D-Series) 0r explosion proof applications (E-Series). SPC02 PC - FW-LiBat-021 Lithium 3xAA-cell battery - SPB03 long life time. Intrinsically Safe (F-Series). PB - Lithium battery 3xAA-cel - long life time. For safe area applications (XX). With retrofit battery clamp for installed F0-Series. SPC03 PC - FW-LiBat-021 Lithium 3xAA-cell battery - long life time. Intrinsically Safe (XI). With retrofit battery clamp for installed F0-Series. Various STC01 Set of terminal connectors Specify: product series, model, serial number and terminal coding. SFU01 Set of fuses for the F-Series & D-Series (10 pcs.). SFS01 Fluidwell logo stickers for front casing. Specify: product series (10 pcs.). Own branding labels on request. Accessories &

D-Series spare parts SDF01/SDF02: Front cover SPB02: Battery D-Series Front covers SDF01 SDF02 Aluminum D-Series frontcover with select / clear keypad, including gasket. Aluminum D-Series frontcover with start / stop keypad, including gasket. D-Series SFU01 SPB02 Set of fuses for the F-Series & D-Series (10 pcs.) PB - Lithium battery 3xAA-cell - long life time. For safe area applications. Accessories &

E-Series accessories ACE01: USB data logging and configuration cable ACE03/04: Stainless steel wall / pipe mounting kit 115 mm (4.53") 100 mm (3.94") 70 (2.76") 118 mm (4.65") 103 mm (4.06") 10 (0.39") 25 mm (0.98") 7 mm (0.28") ACE02: Remote configuration cable for option CX ACE05: Cable with Amphenol connector General E-Series accessories ACE01 ACE02 ACE03 ACE04 ACE05 ACE06 ACE07 Remote configuration and data log cable (2.0m/6.7ft) for option CU - Mini USB to USB. Remote configuration cable (1.8m/5.9ft), for option CX to USB. Stainless steel wall mounting kit (inc. screws+plugs). Stainless steel pipe mounting kit, (worm gear clamps not included, see ACF06 - ACF09). Shielded, two pins, 30cm (12 ) cable with Amphenol connector for turbine flowmeters. Remote configuration cable (1.8m/5.9ft), for option CH - RS485 Communication to USB. Remote configuration cable (1.8m/5.9ft), for option CB - RS232 Communication to USB. ACE06/07: Remote configuration cable RS485/RS232 E-Series SES01 SES02 SPB02 Basic Supply Module for the E-Series. With battery connector and flatcable to the Main Electronics Module, without battery (SPB01) or relays. Relay Supply Module for the E-Series. With two relays, battery connector and flatcable to the main Electronics Module, without battery (SPB01) PB - Lithium battery 3xAA-cell - long life time. For safe area applications. Accessories &

E-Series Blind plugs ABS01/05: Stainless Steel blind plugs ABB01/05: Brass nickel plated blind plugs Technical specification Certification ATEX IECEx I M2 II 2GD Ex d I&IIC Mb Gb. Ex e I&IIC Mb Gb. Ex tb IIIC Db. II 3GD Ex nr IIC Gc. Ex d I&IIC. Ex e I&IIC. Ex tb IIIC. Ex nr IIC. CSA Class I, Division 1 Groups A, B, C & D. Certificate no. ATEX IECEx Class II, Groups E,F & G. Class III SIRA 09ATEX1320X & SIRA 09ATEX4323X. SIR 09.0131X. CSA 2310046 General IP rating IP66 & 68 / Type4X 6P. Ambient Ta -40 C to +70 C (-40 F to +158 F). Brass Nickel plated blind plugs ABB01 ABB02 ABB03 ABB04 ABB05 ABB06 ABB07 Blind plug M20 Brass Nickel Plated. Blind plug M25 Brass Nickel Plated. Blind plug 1 /2 NPT Brass Nickel Plated. Blind plug 3 /4 NPT Brass Nickel Plated. Blind plug 1 NPT Brass Nickel Plated. Blind plug + reducer M25 Brass Nickel Plated for option CU - USB communication. Blind plug + reducer 3 /4 NPT Brass Nickel Plated for option CU - USB communication. Stainless Steel blind plugs ABS01 ABS02 ABS03 ABS04 ABS05 ABS06 ABS07 Blind plug M20 Stainless Steel. Blind plug M25 Stainless Steel. Blind plug 1 /2 NPT Stainless Steel. Blind plug 3 /4 NPT Stainless Steel. Blind plug 1 NPT Stainless Steel. Blind plug + reducer M25 Stainless Steel for option CU - USB communication. Blind plug + reducer 3 /4 NPT Stainless Steel for option CU - USB communication. Accessories &

E-Series Reducers ARS01/04: Stainless Steel reducer ARB01/04: Brass nickel plated reducer Technical specification Certification ATEX IECEx I M2 II 2GD Ex d I&IIC Mb Gb. Ex e I&IIC Mb Gb. Ex tb IIIC Db. II 3GD Ex nr IIC Gc. Ex d I&IIC. Ex e I&IIC. Ex tb IIIC. Ex nr IIC. CSA Class I, Division 1 Groups A, B, C & D. Class II, Groups E,F & G. Class III Brass Nickel plated reducers ARB01 ARB02 ARB03 ARB04 Stainless Steel reducers ARS01 ARS02 ARS03 ARS04 Reducer 1 NPT to 3 /4 NPT Brass Nickel Plated. Reducer 1 NPT to 1 /2 NPT Brass Nickel Plated. Reducer 3 /4 NPT to 1 /2 NPT Brass Nickel Plated. Reducer M25 to M20 Brass Nickel Plated. Reducer 1 NPT to 3 /4 NPT Stainless Steel. Reducer 1 NPT to 1 /2 NPT Stainless Steel. Reducer 3 /4 NPT to 1 /2 NPT Stainless Steel. Reducer M25 to M20 Stainless Steel. Certificate no. ATEX SIRA 09ATEX1322X & SIRA 09ATEX4323X. IECEx SIR 09.0131X. CSA 2310046 General IP rating IP66 & 68 / Type4X 6P. Ambient Ta -40 C to +70 C (-40 F to +158 F). Accessories &

F-Series accessories ACF02/ACF05: Mounting accessories Intrinisically safe isolators ACF11: Swivel for direct flowmeter mounting F-Series Mounting accessories ACF02 ACF05 ACF06 ACF07 ACF08 ACF09 ACF11 Stainless steel wall mounting kit. (incl. screws and plugs) Stainless steel pipe mounting kit. (worm gear clamps NOT included) Two stainless steel worm gear clamps. D=44-56mm (1.73-2.20 ) Two stainless steel worm gear clamps. D=58-75mm (2.29-2.95 ) Two stainless steel worm gear clamps. D=77-95mm (3.04-3.74 ) Two stainless steel worm gear clamps. D=106-138mm (4.18-5.43 ) Swivel with 25 movement from center axis for direct flowmeter mounting: 1 NPT to 1 /2 NPT Intrinisically safe isolaters ACG01 MTL5511 - I.S. one channel switch output > ACG02 ACG03 mechanic relay. MTL5525 - I.S. power supply MTL5541 - I.S. 4-20mA repeater to safe area. ACG04 MTL5051- I.S. serial comm. isolator for TTL > RS422/232 ACG05 MTL5516C - I.S. two channel switch output > mechanic relay. ACG06 MTL5513 - I.S. two channel switch output > ACG07 ACG08 ACG09 floating solid state. MTLS5546-4-20mA isolater from safe to hazardous area. MTL5541AS - I.S. 4-20mA repeater for HART communication to safe area, with current sink for safe area connection. MTL7787+ - I.S. digital (on/off) zener diode barrier. Accessories &

F-Series enclosures Back cover F Series Front covers F-Series F-Series Front covers SFF01 SFF02 SFF03 SFF04 SFF05 SFF06 Aluminum F-Series front cover with select / clear keypad, including gasket Aluminum F-Series front cover with start / stop keypad, including gasket Aluminum F-Series front cover with arrows keypad, including gasket GRP F-Series front cover with select / clear keypad, including gasket GRP F-Series front cover with start / stop keypad, including gasket GRP F-Series front cover with arrows keypad, including gasket F-Series Back cover SFB01 SFB02 SFB03 SFB04 SFB05 SFB06 SFB07 SFB08 SFB09 SFB10 SFB11 SFB12 SFB13 SFB14 SFB15 SFB16 SFB17 Aluminum field enclosure HA - IP67 / Type4X Drilling: 2 x PG9 + 1 x M20. Aluminum field enclosure HM - IP67 / Type4X Drilling: 2 x M16 + 1 X M20. Aluminum field enclosure HN - IP67 / Type4X Drilling: 1 x M20. Aluminum field enclosure HO - IP67 / Type4X Drilling:2 x M20. Aluminum field enclosure HP - IP67 / Type4X Drilling:6 x M12 Aluminum field encolsure HT - IP67 / Type4X Drilling:1 x 1 /2 NPT. Aluminum field enclosure HU - IP67 / Type4X Drilling: 3 x 1 /2 NPT Aluminum field enclosure HV - IP67 / Type4X Drilling: 4 X M20. Aluminum field enclosure HZ - IP67 / Type4X No holes GRP field enclosure HD - IP67 / Type4X No holes. GRP field enclosure HD - IP67 / Type4X Drilling: 2 x 16mm (0,63 ) + 1 x 20mm (0,79 ). GRP field enclosure HDA - IP67 / Type4X Drilling: 1 x 22mm (0,87 ). GRP field enclosure HD - IP67 / Type4X Drilling: 2 x 20mm (0,79 ). GRP field enclosure HD - IP67 / Type4X Drilling: 6 x 12mm (0,47 ). GRP field enclosure HD - IP67 / Type4X Drilling: 3 x 22mm (0,87 ). GRP FLAT BACK field enclosure HK - IP67 / Type4X No holes. Aluminum field enclosure HL - IP67 / Type4X Drilling: 2 x 1 /2 NPT. Accessories &

F-Series accessories Cable glands Blind plugs F-Series Cable glands ACF20 ACF25 ACF26 ACF27 ACF28 ACF29 ACF31 ACF32 ACF33 ACF34 ACF35 ACF39 ACF40 ACF41 Polyamide cable glands for HA: 2 x PG9, 1 x M20 incl. O-rings. Polyamide cable glands for HE: 2 x M16, 1 x M20 incl. locknut and O-rings. Polyamide cable glands for HF: 1 x M20 incl. locknut and O-ring. Polyamide cable glands for HG: 2 x M20 incl. locknuts and O-rings. Polyamide cable glands for HH: 6 x M12 incl. locknuts and O-rings. Polyamide cable glands for HJ: 3x M20 incl. locknuts and O-rings.. Polyamide cable glands for HL: 2 x 1 /2 NPT incl. O-rings. Polyamide cable glands for HM: 2 x M16, 1 x M20 incl. O-ring. Polyamide cable glands for HN: 1 x M20 incl. O-ring. Polyamide cable glands for HO: 2 x M20 incl. O-rings. Polyamide cable glands for HP: 6 x M12 incl. O-rings. Polyamide cable glands for HT: 1 x 1 /2 NPT inlc O-Ring. Polyamide cable glands for HU: 3. x 1 /2 NPT inlc O-Rings. Polyamide cable glands for HV: 4 x M20 incl. O-rings. F-Series Blind plugs ACF50 ACF55 ACF56 ACF57 ACF58 ACF59 ACF61 ACF62 ACF63 ACF64 ACF65 ACF69 ACF70 ACF71 Polyamide blind plugs for HA: 2 x PG9, 1 x M20 incl. O-rings. Polyamide blind plugs for HE: 2 x M16, 1 x M20 incl. locknut and O-rings. Polyamide blind plugs for HF: 1 x M20 incl. locknut and O-ring. Polyamide blind plugs for HG: 2 x M20 incl. locknuts and O-rings. Polyamide blind plugs for HH: 6 x M12 incl. locknuts and O-rings. Polyamide blind plugs for HJ: 3x M20 incl. locknuts and O-rings.. Polyamide blind plugs for HL: 2 x 1 /2 NPT incl. O-rings. Polyamide blind plugs for HM: 2 x M16, 1 x M20 incl. O-ring. Polyamide blind plugs for HN: 1 x M20 incl. O-ring. Polyamide blind plugs for HO: 2 x M20 incl. O-rings. Polyamide blind plugs for HP: 6 x M12 incl. O-rings. Polyamide blind plugs for HT: 1 x 1 /2 NPT inlc O-Ring. Polyamide blind plugs for HU: 3. x 1 /2 NPT inlc O-Rings. Polyamide blind plugs for HV: 4 x M20 incl. O-rings. Accessories &

N-Series accessories ACN01: Shock proof mounting brackets SRN01: Spare part - field replaceable relays (2pcs) SNF01: Spare part - Aluminum N-Series front cover N-Series Accessories & spare parts ACN01 SRN01 SNF01 Shock proof stainless steel mounting brackets (2pcs). Spare part: Set of field replaceable, mechanical make-and-break (NO-NC) relays (2pcs). Max. switching capacity (resistive load): 8A@250VAC/30VDC Max. switching power (resistive load): 2000VA 240W Spare part: Aluminum N-Series front cover with numerical keypad, incl. gasket. Accessories &

Printer accessories ACP01: Thermal, handheld printer ACP02 / ACP03: Thermal panel mount printer User-friendly portable printer with single-handed paper-load system. High speed and high quality printing mechanism with superb text quality. Suitable for the F132, N413 and N414 batch controllers. Robust design which is suitable for both vertical and horizontal panel mounting. Increased usability with expanded reporting for head up and paper out errors. Suitable for the F132, N413 and N414 batch controllers. Specifications Data Input RS-232 Serial Data Buffer 20 KB Baud Rate Up to 57,600 (9600 Default) Print Method Fixed head thermal mechanism Print Width 48 mm Dot spacing 8 dots/mm (vertical and horizontal) Dots per line 384 Font (dots) 7 x 24 / 10 x 24 Paper rol lenght 16 m Dimensions 47 x 92 x 108 mm (H x W x L) Weight 330 gr (including battery and full roll of paper) Temperature Ambient 0-50 C (32-122 F) ACP01 Ap 1300 - Thermal portable printer (incl. cables and battery charger). Specifications Data Input RS-232 Serial Data Buffer 10 KB Baud Rate Up to 115,200 Baud (9600 Default) Print Method Fixed head thermal mechanism Print Width 48 mm Dot spacing 8 dots/mm (vertical and horizontal) Dots per line 384 Font (dots) 8 x 16 / 7 x 24 / 10 x 24 Paper rol lenght 12 m Dimensions 80 x 83 x 52mm (H x W x D) Panel cut-out 75 x 75 mm ( W x D ) Weight 110 gr (without paper) Temperature Ambient 0-50 C (32-122 F) ACP02 Ap 1400 - Thermal panel printer with standard 9V DC to 36V DC power supply (incl. cables). ACP03 Ap 1400 - Thermal panel printer with external 100-240V AC power supply (incl. cables). Quality ISO 9001 www.dekra-seal.com certified Fluidwell bv P.O. Box 6 5460 AA Veghel Voltaweg 23 5466 AZ Veghel The Netherlands Telephone: +31 (0) 413-343 786 Telefax: +31 (0) 413-363 443 Email: displays@fluidwell.com Internet: www.fluidwell.com Specifications are subject to change without notice. Copyright: Fluidwell bv - 2018 -ACCESORIES-DATA-EN-V1820