Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Similar documents
Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Solenoid interlock AZM 170

Operating instructions Solenoid interlock AZM About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Safety Sensor CSS 180 Product Information

Solenoid interlock AZM 200 The non-contact interlock.

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Sense7-series Non-contact coded safety switch

AZM 161SK 12/12RKED/TU 024

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Technical data. Standards: IEC/EN BG-GS-ET-15

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Safety door-handle system STS

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

AZM300 More than just a solenoid interlock

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

ZB0050 / ZB0051 ZB0070 / ZB0071

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Oil-free piston compressors KK and piston vacuum pumps KV

EStrong-series Emergency Stop

Safety switches with separate actuator

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

SG-B1 SERIES / SG-A1 SERIES

Control block VOFA with safety function

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Installation and Operating Instructions

Installation and Operating Instructions

Assembly and Maintenance Manual Type ASNU

Safety switches with solenoid and separate actuator

Guard locking systems for the protection of man and machine

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Safety switches with solenoid and separate actuator

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Assembly and Maintenance Manual Type AS

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

MKey9-series Safety Interlock Switch with Guard Locking

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Transponder-coded. with guard locking

Safety switches for hinges

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Ex m Solenoid Operator Type 0519

Technical Documentation

More than just a solenoid interlock AZM300

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

Safety switches with separate actuator

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

FL series position switches

Transponder-coded. with guard locking

HBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

Position Switches Series 8074/2

CAUTION CM-SE CM-S21 CM-S41

Tina 4A Connection block

Compensation unit AGE-XY 50-80

Support T10552 T10595 T40386

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Thermal-Magnetic Circuit Breaker M1-...

HST -LS Interlocking device (Translation of Original Manual)

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Safety rope switches with reset for emergency stop

Position switches FD series

SFS-UFS Single Foot Switches

Prewired position switches FF series

Operating instructions Flow monitors SI / / 2010

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Hinged Safety Door Switch

LR-LX-LK-LW Safety Switches with separate actuator

MANUAL. Single charger

Operating Instructions

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Bowl Feeder BF10 / BF15 Translation of original operating instruction

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Adjustable Speaker Mount GRAVIS 12

Position switches FR series

Transcription:

Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr. 9 Content About this document. Function.... Target group: authorised qualified personnel..... Explanation of the symbols used.... Appropriate use.... General safety instructions.... Warning about misuse.... Exclusion of liability... Product description. Ordering code.... Special versions..... Destination and use.... Technical data.... Safety classification... Mounting. General mounting instructions.... Dimensions.... Axial misalignment..... Adjustment.... Electrical connection. General information for electrical connection..... Contact variants..... Connector plug.... Set-up and maintenance. Functional testing..... Maintenance.... About this document. Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.. Target group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.. Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.. Appropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant. The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".. General safety instructions The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.

Safety sensor BNS. Warning about misuse In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded when safety switchgear is used. The relevant requirements of the standard ISO 9 must be observed.. Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.. Product description. Ordering code This operating instructions manual applies to the following types: BNS -➀➁Z➂-➃-➄-➅ No. Option Description ➀ Safety contacts: NO / NC 0 NC ➁ Signalling contacts: No signalling contact /0 NC ➂ Without LED G With LED ➃ connecting cable ST Connector plug M 8 ➄ L Left hinged door R Right hinged door ➅ 0 Version with extended switching distance (in combination with actuator) BPS --0 or BPS --0). Special versions For special versions, which are not listed in the order code below., these specifications apply accordingly, provided that they correspond to the standard version.. Destination and use The BNS safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards to ISO 9 and IEC 09--. To actuate the safety sensors, only the BPS - (-0) or BPS 0- (-0) actuators can be used. The safety sensors are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened. The safety switchgears are classified according to ISO 9 as type switching devices. Only the entire system consisting of the safety sensor (BNS ), the actuator (BPS ) and the safety-monitoring module (AES, SRB) meets the requirements of the standard IEC 09--. The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level. The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.. Technical data Standards: IEC 09--, BG-GS-ET- Enclosure: glass-fibre reinforced thermoplastic Protection class: IP to IEC 09 Connection: Connecting cable LIYY or connector plug M8 Cable section of connecting cable: - without signalling contact: x 0. mm² - with signalling contact: x 0. mm² Version with integrated connector: - without signalling contact: M8 x, -pole, with screw terminal or snap fitting - with signalling contact: 8 mm, -pole, with snap fitting Tightening torque for connectors: max. 0. Nm Operating principle: magnetic Actuator: BPS - (-0), BPS - (-0), coded Coding level according to ISO 9: low Switching distances: - Assured switching distance s ao : mm, 0 mm (ordering suffix -0) - Assured switch-off distance s ar : mm, 0 mm (ordering suffix -0) Switching condition indication: LED only with ordering suffix G Rated insulation voltage U i : - without LED: 0 VAC / VDC - with LED: VDC Rated impulse withstand voltage U imp : 0.8 kv Switching voltage: - without LED: max. VDC - with LED: max. VDC - with -pole connector: max. 0 V Switching current: - without LED: max. 00 ma - with LED: max. 0 ma Switching capacity: - without LED: max. 0 W - with LED: max. 0 mw Required short-circuit current: 00 A Ambient temperature: C... +0 C Storage and transport temperature: C... +0 C Max. switching frequency: Hz Resistance to shock: 0 g / ms Resistance to vibration: 0... Hz, amplitude mm. Safety classification Standards: ISO 89- Safety contact: - NC / NC combination: S-S and S-S - NC / NO combination: S-S and S-S Intended structure: - -channel usage: usable to cat. / PL e with suitable logic unit B 0d NC contacts at 0 % contact load:.000.000 B 0d NO contacts at 0 % contact load:.000.000 Service life: 0 years MTTF D B0D dop x hop n x 00 s/h op 0, x n op t cycle (Determined values can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) If multiple safety components are wired in series, the Performance Level to ISO 89- will be reduced due to the restricted error detection under certain circumstances.

Safety sensor BNS. Mounting. General mounting instructions During fitting, the requirements of ISO 9 must be observed. Safety sensor with cable, left hinged door ø,, Fitting is only authorised in a de-energised condition. Do not use the sensor and the actuator as a mechanical backstop. Any mounting position, provided that the active surfaces are opposite. Do not subject the safety sensor and actuator to extreme vibrations and shocks. 8 To avoid any interference inherent to this kind of system and any reduction of the switching distances, please observe the following guidelines: Ensure the safety sensor is mounted on a flat surface Do not install the safety sensor and the actuator in strong magnetic fields If possible, do not mount the sensor and the actuator on ferromagnetic material. A non-magnetic spacer at least mm thick or the original spacer must be used. The use of non-magnetic fixing screws is recommended also. Keep away from metal chips The mounting distance between two sensors should always be at least 0 mm Actuator ø,, Safety sensor and actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).. Dimensions All measurements in mm. 8 Sensor with connector, right hinged door, ø, Spacer, 8 ø 8 8,

Safety sensor BNS. Axial misalignment A horizontal and vertical misalignment of the safety sensor and the actuator is tolerated. The possible misalignment depends on the distance of the active surface of the sensor and the actuator. The sensor remains active within the tolerance range. The specified switching distances refer to opposedly mounted safety sensors and actuators. BPS -,, 8,, 0. Electrical connection. General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. The safety sensors must be wired in accordance with the wire colours or the pin configuration.. Contact variants The contact position shows the actuated sensor function when the safety guard is closed. For safety sensors with LED, the LED is illuminated when the safety guard is closed. The contact configurations of the versions with or without LED are identical. Safety contacts: Signalling contact: S-S and S-S or S-S S-S BPS - 8,,,, 0 The numbers between brackets indicate the PIN configuration of the versions with integrated connector; indication of the wire colours for the version with cable. BNS -0Z(G) () BK S () WH S BNS -Z(G) () BK S () WH S S BU () S BN () S BU () S BN () Assured switching distance: Assured switch-off distance:. Adjustment s ao = mm 0mm (Ordering suffix -0) s ar = mm 0mm (Ordering suffix -0) Recommended Adjustment Align the safety sensor and actuator at a distance of 0. x s ao. Align the central markings of the safety sensor and the actuator with each other. The LED can only be used as rough setting tool. The correct functionality of both safety channels must be checked by means of the connected safety-monitoring module. BNS -0/0Z(G) () GY S () GN S () WH S BNS -/0Z(G) () GY S () GN S () WH S S PK () S YE () S BN () S PK () S YE () S BN () Information for the selection of suitable safety-monitoring modules can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. Connecting multiple BNS -Z safety sensors to one AES safetymonitoring module is technically possible. To connect multiple safety sensors (check if authorised!), their NO contacts are wired in parallel and their NC contacts in series. The Protect-IE- or -0 or PROTECT-PE- (-AN) or -0 input expander module can be used to connect up to safety sensors with NC/NC or NC/NO contacts. Safety sensors equipped with LED's shall not be wired in series, except for the Protect-IE or PROTECT-PE input expander module. As a result of this, the luminosity of the LED's would considerably decrease and the voltage could drop below the minimum input voltage of the downstream safety-monitoring module.

Safety sensor BNS. Connector plug Connector plug M8, -pole, with screw terminal or snap fitting Accessories: connecting cable with coupling 8 mm, -pole, with snap fitting M8, -pole, with screw terminal m m 0 m BN straight 0099 00998 - WH BU BK angled 00 009-8 mm, -pole, with snap fitting m m 0 m GN YE straight 0000 000 000 GY PK WH angled 000 000 000 BN Accessory: Y-adapter BNS-Y- BNS -Z -Z. Set-up and maintenance. Functional testing The safety function of the safety sensor must be tested. The following conditions must be previously checked and met:. Fitting of the sensor and the actuator.. Fitting and integrity of the power cable.. The system is free of dirt and soiling (in particular metal chips).. Maintenance In the case of correct installation and adequate use, the safety sensor features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended: Check of the safety function Check the fitting of the sensor and the actuator. Remove possible metal chips. Check the cable for damage. Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators. Damaged or defective components must be replaced.. Disassembly and disposal. Disassembly The safety sensor must be disassembled in de-energised condition only.. Disposal The safety sensor must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. AES SRB S S S S BNS-Y- Accessory: Y-adapter BNS-Y-0 BNS -0Z 0-0z AES SRB S S S S BNS-Y-0

Safety sensor BNS. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 0 9 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. Name of the component: BNS Type: See ordering code Description of the component: Safety-sensor with magnetic operating principle in combination with the AES / AZR / SRB safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the DIN 09--. Relevant Directives: Machinery Directive RoHS-Directive 00//EC 0//EU Applied standards: DIN 09--: 0, DIN ISO 9: 0 Person authorized for the compilation of the technical documentation: Oliver Wacker Möddinghofe 0 9 Wuppertal Place and date of issue: Wuppertal, March, 0 BNS-E- Authorised signature Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 0, D - 9 Wuppertal Postfach 0, D - Wuppertal Phone: +9 - (0) 0 - - 0 Telefax: +9 - (0) 0 - - 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com