Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Similar documents
Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

FUME HOOD SELECTION GUIDE

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

MODEL NO. - ACM-1212FH FUME HOOD

Product Datasheet. Cable TV Junction Box (Page 4)

General Purpose Walk-In Fume Hood

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

F. VAV hoods shall have a restricted bypass plate.

General Purpose Walk-In Fume Hood

LABORATORY FUME HOODS

LABORATORY FUME HOODS

KENYA MARINE AND FISHERIES RESEARCH INSTITUTE

Protector XStream Laboratory Hoods

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Polypropylene Total Exhaust Fume Hoods

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket

LABORATORY FUME HOODS OF 5

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

Design Standard - Fume Hoods & Fume Hood Exhausts

CORPORATION DURALAB CORPORA

HEMCO. Laboratory Fume HoodsR

Bedcolab Vanguard Laboratory Fume Hoods

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

new fume hoods providing performance and protection

Supreme Air Fume Hood Option Availability

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Fume Hoods Overview OVERVIEW

Direct Gas-Fired Heating

AUDIO-VISUAL EQUIPMENT

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Labconco 48, 60, and 72 Hoods

Accessories Standard Service Fixture Kits

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

ANATOMY DISSECTION TABLES

Fume Hood Operation & Maintenance Manual

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Climas y Proyectos Leyco, S.A. de C.V.

LABORATORY CABINETRY AND SPECIALTIES: FUME HOODS

Circulaire. Superb Containment, Excellent Capacity. Filtration Fume Cabinets

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Ductless Nanoparticle Containment Enclosures

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

Esco Ascent Max Ductless Fume Hood

Fume cupboards and extraction devices

Completing Your Fume Removal System

SECTION WELDING FUME EXHAUST SYSTEM

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

SECTION AXIAL HVAC FANS

Model ND-2 Specification

High Performance Ductless Balance Enclosures

Laboratory Fume Hoods & Enclosures

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

User s Manual. Protector Laboratory Fume Hoods

Tube Axial Inline Fans

Blower Specifications

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

CURVED CC5 CC5 RF6 CC5 RF9 CC5 RF12 CC5 RF15 CC5 HT6 CC5 HT9 CC5 HT12. Page 1. Download C.A.D models or contact us on COSSIGA.COM

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series

Ventilated Balance Enclosures

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Ductless Nanoparticle Containment Enclosures

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Fume extractor is warranted for two years, parts and labor.

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Global Finishing Solutions Table of Contents

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

Protector Demonstration Hoods

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Dust Collectors and Fume Exhausters

th Avenue Spring Lake, MI Ph:

Filtered Kitchen Supply Packaged Ventilator

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

LABORATORY HOOD MANUAL

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Transcription:

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria 1) The laboratory fume hoods must confirm to the following regulations and standards. 2) ASHRAE 110 1995, American Society of Heating, Refrigerating, and Air Conditioning Engineers, Method of Testing Performance of Laboratory Fume Hoods. 3) EN 14175, The European Standard EN 14175:2003, Method of Testing Performance of Laboratory Fume Hoods. 4) The bidder should have in house ASHRAE 110: 1995 and EN 14175:2003 fume hood test facility. Past ASHRAE and EN test reports & photographs of this test facility must be attached to the technical bid. 5) At least 2 Customer feedback forms stating the quality of work and overall feedback of Project Values of at least Rs. 1 Crore for one project and Rs. 40 Lacs each for the remaining two projects. 6) Bidder/ parent company should have SEFA Membership Certificates for Last three years on a continuous basis. 7) Bidder/ parent company has to submit: A). Test Report: Furniture to be type tested as per SEFA 8 standard by a third party. B). Test Report: Fume Hood to be type tested as per EN 14175 by a third party. C). Test Report: Fume Hood to be type tested as per ASHRAE 110 by a third party. 8) Membership Certificate: The bidder/parent company should possess the key professional staff, at least one, in his organization with good knowledge of codes and standards like SEFA, OSHA, EN 14175, ASHRAE 110 etc. Such professionals should have a valid membership of SEFA. 9) Additional Certificate: ISO 9001 2008, ISO 14001 2004, OSHAS 18001 2007 (For Design, Development, Manufacturing, Supply and servicing) should be submitted by the bidder/parent company. 10) The bidder or its parent company in India or abroad should have a well established (their own) in house manufacturing unit for the steel lab furniture and fume hood, quality management system as per International standards providing the products and

services on the continuous basis at least for the last 7 years. The bidder or its parent company in India or abroad should possess the current/valid approval for such items manufacturing facility by a statutory certifying authority, like factory inspector etc. Manufacturers should have 100% modern and sophisticated manufacturing facility having strict quality checks at every level. 11) 1000 hour salt spray test report (by third party) for powder coating quality assurance also must be attached to the technical bid. 12) MOC of the Fume hood should be GI (Galvanized Iron) 1 1.3mm 13) Bidder / parent company will have to submit a No Deviation compliance sheet, any deviation from the technical specification will lead to cancelation. Technical Specifications for 5 Feet Regular Fume Hood Quantity: 4 no.s Overall Dimensions with base cabinet: Fume Hood dimensions: Base Cabinet dimensions: Inside Fume Hood working volume: Bed size: 1800 mm W X 900 mm D X 2400 mm H 1800 mm W X 900 mm D X 1600 mm H 1700 mm W X 540 mm D X 700 mm H 1520 mm W X 650 mm D X 1155 mm H 1520 mm W X 650 mm D Sr. Specification Desription No 1 Design Basis 2 Design Structure Aerodynamic, Floor mounted American Design Standard: ASHRAE110-1995 European Design Standard: EN-14175-2003 3 Airflow Type Low Constant Volume (for A.C. environment) 4 Color Combination Grey & White 5 Powder coating Pre-treated with 8 tank chemical processes and powder coated with highly chemical resistant material having appropriate dry film thickness. 6 Material of Construction of Galvanized Iron (GI) as per IS 277: 2003 standard of

superstructure 1.0 mm thickness for all sheet metal paneling 1.2 mm for back pillars 1.2 mm for front corner post 7 Front Top Panel 8 Corner Post 9 Construction (Interior) 10 Active Kinetics exhaust system 11 Airfoil 12 Worktop 13 Sink, Water tap with drain arrangement 14 Sash (Shutter) 15 Wet & Dry Service valves Easily openable hinged Top Panel for easy access to Flow Control Valve and Electrical Lighting fixtures for maintenance. Triangular profiled Corner Post should be placed on Left and Right Hand Side of the Fume hood for the utility line fittings and electrical receptacles. Chemical & Heat Resistant, Fire Retardant, Smooth Finish, Easily Cleanable Panels should be made out of durable PRL integral work walls. Interstitial 7-point active kinetics exhaust system (for light, normal & heavy fumes) with baffle to ensure rapid exhaust of fumes. Aerodynamic Design, Horizontal fixed airfoil mounted on the worktop made of SS. Chemical resistant splash & spillage proof dished Jet Black Granite worktop (18 +1 mm thick). Skirting of 15 mm from all sides for no chemical spillage. Worktop will have sink sealed with silicon sealant for drainage with water tap on left back side of worktop. Sink will have a trap for waste collection. dimensions of sink should be 100 mm X 200 mm sink Vertical rising sash counter-balanced with pulley and counterweight system. Toughened Float Glass sash (4 mm thick). Smooth and light sash operation. Clear open able height = 750 mm. Impact Resistance of the sash (Toughened Glass) is four times higher than other sash materials (like Safety Glass and Polycarbonate). Breaking Stress value for fully toughened glass (Tempered Glass) = 24,000 psi. Remotely operated Color coded Brass Needle Valves for fine control over utilities (as per DIN 12920 norms) total 6 nos. service valves with PU plumbing with 6 mm internal dia, withstands up to 5 kgf pressure ( 4 LHS)

1 for Raw water (PU) 1 for Nitrogen(PU) 1 for Vacuum(Teflon) 1 for Compressed Air (PU) 16 Maintenance ports 17 Internal nozzles 18 Lighting 19 Electrical Utilities 20 Built-in Starter Open-able top panel for easy maintenance of tube light and flow control valve service panel for maintenance of utility valves and tubing. Fittings should be coated with Brass powder to avoid the intermingling of the flexible tubes. Also the taps should be tapered in shape to use with flexible tubing of sizes from ¼ to ½ in dia, to provide greater flexibility to the user. Fluorescent light (minimum 40 watt, 2 Nos.) with vapour-proof fitting for proper illumination. Intensity approx 400 lux at worktop level. 6 nos. electrical sockets NorthWest make (230 V, 6/16 A, 50 Hz), 6 nos. NorthWest make MCBs with blower NO/NC switch with built in starter & light switch on front fascia. Cables & wires should be Fire Retardant grade. The electrical wiring should have built-in starter of Telemechanique make; suitable to blower motor capacity. 21 Cable entering port For easy access of cables from fume hood to electrical sockets. 22 Chemical Storage Base Cabinet (Ventilated on Castors) Base cabinet should be ready to receive the fume hood at its top. It should have following features: Completely made from 1mm thick GI sheet with Highly corrosion resistant epoxy powder coating,60-80 microns thickness. Cabinet integral work walls will be Special chemical & heat resistant, smooth finish, easily cleanable panels made out of durable PRL sheets. Two exhaust ports connected to the fume hood exhaust system internally. One removable horizontal partition to store chemicals. PP Trays for chemical storage.

Cabinets on castors. Roller catch of HAFELE Germany Make for the Base Cabinet doors. Polyamide Hinges from outside of Base Cabinet. Overall Dimensions: 850 mm W X 540 mm D X 700 mm H 2nos. A grid made up of Duralumin Powder coated rod (Dia. 12.7 mm) 23 Apparatus Holding Grid (Lattice to hold the apparatus. It should cover the entire length of the fume Assembly) hood and should be built-in at fume hood backside. Installed at the distance of 150 mm from backside of fume hood. 24 Level adjusting screws Made of SS Bolts to adjust the fume hood level by +or - 10 mm. 25 Exhaust Port Unique exhaust port design should ensure that the fumes will be exhausted smoothly without any turbulence at the exhaust port. Also it should ensure low noise level. Dia. 250 mm 26 Flow control valve To regulate airflow. 27 Noise Level < 70db at 1 meter from fume hood. 28 Auto fire extinguisher Fire extinguisher to take care of fire erupting within the fume hood. The sensing tube/ sensor will activate immediately after fire breaks out within the hood. Sensor threshold: 68 degree centigrade. Media: ABC Dry Powder CENTRIFUGAL BLOWER: (For air suction in cluster of 2 nos. Fume Hood) - 2Nos. Silent PP + FRP high efficiency remote blower, consisting of continuous rating motor and chemical resistant impeller. It satisfies international safe velocity norms. Sr. No Specification Description 1 Construction SISW type, chemical & heat resistant PP + FRP blower with aerodynamically balanced PP impeller, with drain plug. 2 Air Suction Capacity 600 CFM confirming to international face velocity norms and as per safe fume hood airflow pattern. 3 Motor Crompton / LHP/Other Reputed make, 2 HP Motor 3 Phase TEFC, IP 55, Class F, continuous rating. As per IS 325. 4 Drive Direct Drive

DUCTING: Chemical resistant PP + FRP (3mm + 2mm) rigid & flexible ductwork from Fume hood to exhaust stack point with weatherproof canopy. Total ducting with horizontal, vertical members, flanges, bends, bracketed supports and gooseneck exhaust stack. INSTALLATION: Should be carried out by vendor s skilled team with ductwork design, fitting, fixing of blower, commissioning & testing of the same. TESTING: All fume hoods should be factory tested as per ASHRAE110:1995 face velocity norms. Also, Onsite Validation should be carried out to ensure working of fume hood as per international norms. Tracer gas containment testing can be asked to be carried out at vendor s factory (extra cost can be charged). WARRANTY: Minimum 12 months warranty against all manufacturing defects from the date of installation. DELIVERY: As soon as possible after the release of PO. Terms and Conditions: 1. Prices should include transportation, installation, and maintenance for a year, including all manufacturing flaws. 2. 1 year warranty. 3. Maximum educational discount. 4. Other specification according to the above technical requirements including commercial bids. 5. Quoted price should be in Indian Rupees only.

Please mention Fume Hoods for Chemistry Laboratory (-----) on the sealed envelope carrying the quotation and related literature. Send your best offer on or before 28.2.2017 to the following address. Dr. Dattatraya H. Dethe Associate Professor Lab No:101E, Old Core Lab, IIT Kanpur Tel: +91-512-259-6788 Email: ddethe@iitk.ac.in