TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

Similar documents
Amendment to Test Report

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

Installation Couplers intended for permanent connection in fixed installation

Amendment to Test Report

SGS Australia Pty Ltd

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Page 2 of 23 UNT150420C11

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Test Report issued under the responsibility of:

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Test Report issued under the responsibility of: BA-10CA08002-K-1 Date of issue... : Total number of pages Report Reference No...

Test Report issued under the responsibility of:

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

LIA Laboratories Limited

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

PLUG-IMQ 3/4

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LIA Laboratories Limited

Certificate of Compliance

Certificate of Compliance

Page 3 of 34 Report No Part I

LIA Laboratories Limited

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Certificate of Compliance

AS/NZS AS/NZS

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

File E Vol. 1 Sec. 125 Page 1 Issued: and Report Revised:

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Certificate of Compliance

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Connectors Safety requirements and tests

Page 1 of 27 Report No. : HT15DR LVD Test Report

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT DIN V VDE V

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT DIN V VDE V

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R.

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

Installation Couplers intended for permanent connection in fixed installation

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

Standards Update Notice (SUN) Issued: June 6, 2017

COVER PAGE FOR TEST REPORT

Information technology equipment Safety Part 1: General requirements

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

TEST REPORT IEC Connectors Safety requirements and tests

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.

SGS Australia Pty Ltd

List of Attachments (including a total number of pages in each attachment):

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

REFERENCE REV CP_TSSPEC_016 1 TITLE SPECIFICATION FOR DATE: NOVEMBER 2010 LIGHTING TABLE OF CONTENTS Page FOREWORD INTRODUCTION

Power Supply XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

IEC Information technology equipment Safety Part 1: General requirements

This standard covers the requirements of luminaires for emergency lighting chains. This standard covers safety and performance requirements.

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

Australian/New Zealand Standard

IEC Information technology equipment Safety Part 1: General requirements

NCB Intertek Testing Services NA, Inc.

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China

Transcription:

Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular requirements: Section Two Recessed luminaires CB/CCA Testing Laboratory Name: Nemko A/S Phone: (+47) 22 96 03 30 Address... :... : Address... : P.O. Box 73 Blindern, N-0314 Oslo, Norway Nordtronic ApS Aalborgvej 86, DK-9300 Sæby, Denmark Test specification: Standard... : Test procedure... : Non- IEC 60598-2-2:1996+A1:1997 used in conjunction with IEC 60598-1:2008 Nemko N/A Test item description...: Recessed downligths Trade Mark...: Nordtronic ApS Manufacturer...: Nordtronic ApS Model/Type reference...: See page 3 Ratings...: See page 3 This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Page 2 of 6 Report No.:220130 Testing procedure and testing location: CB Testing Laboratory: Nemko AS Testing location/ address... : Gaustadalléen 30, N-0373 Oslo Norway Associated CB Laboratory: Testing location/ address... : Victor He Tore Ledaal Testing procedure: TMP Testing procedure: WMT Witnessed by (+ signature)...: Testing procedure: SMT Supervised by (+ signature)...: Testing procedure: RMT Supervised by (+ signature)...:

Page 3 of 6 Report No.:220130 Summary of testing: Tests performed (name of test and test clause): Testing location: Heating test according Cl.12 The 1 st Revision report no.220130 which correct the mounting position on page 5 with bold letter, added in page 6 for new mounting position test result. Nemko AS Gaustadalleen 30 0373 Oslo The 2 nd Revision report no. 220130 which modified the limit values based on manufacturers updated information. The modifications are in bold letter. Copy of marking plate: Rev. page, ver.#2 2012-09-19..

Page 4 of 6 Report No.:220130 Test item particulars... : Classification of installation and use... : Recessed, normal use Supply Connection... : Screwless terminal... :... : Possible test case verdicts: - test case does not apply to the test object... : N/A - test object does meet the requirement... : P (Pass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : 2012-09-11 Date (s) of performance of tests... : 2012-09-12, 2012-09-16 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 60598-1 General product information:

Page 5 of 6 Report No.:220130 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference... : Nordtronic Low Profile LED Spot Lamp used... : Integral LED module Lamp control gear used... : Nordtronic Low Proflie LED Spot Mounting position of luminaire... : Recessed in ceiling wooden case covered with 200mm thermal insulating material. Supply wattage (W)... : 7,3W @ 243,8V; 7,1W @ 230V Supply current (A)... : 36mA@ 243,8V; 35mA@ 230V Calculated power factor... : 0,83 / 0,88 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : Short-circuit output of CG, no hazard - test 1: rated voltage... : - test 2: 1,06 times rated voltage or 1,05 times - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times Through wiring or looping-in wiring loaded by a current of A during the test... : P 1,06 x 230V = 243,8V temperature (C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit Test 4 limit Wooden box over lamp 56 90 Wooden box ring of hole 48 90 Wooden support under CG 61 90 Plastic enclosure of lamp 66 120 Enclosure of CG (tc mark) 68 80 Lampholder 80 > 200 * ) Wiring to lampholder 69 200 Main transformer in CG 90 110 Supply terminal in CG 42 > 85 * ) * ) depend on the component cert. temperature rating. The figure is normal temperature rating for such parts. Revision page, ver.#2 2012-09-19

Page 6 of 6 Report No.:220130 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference... : Nordtronic Low Profile LED Spot Lamp used... : Integral LED module Lamp control gear used... : Nordtronic Low Proflie LED Spot Mounting position of luminaire... : Recessed in ceiling direct covered with 200mm thermal insulating material. Supply wattage (W)... : 7,3W @ 243,8V; 7,1W @ 230V Supply current (A)... : 36mA@ 243,8V; 35mA@ 230V Calculated power factor... : 0,83 / 0,88 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : Short-circuit output of CG, no hazard P - test 1: rated voltage... : - test 2: 1,06 times rated voltage or 1,05 times - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times Through wiring or looping-in wiring loaded by a current of A during the test... : 1,06 x 230V = 243,8V temperature (C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit Test 4 limit Lamp top surface 71 90 Ring of wooden hole 52 90 Wooden support under CG 75 90 Plastic enclosure of lamp 73 120 Enclosure of CG (tc mark) 78 80 Lampholder 84 > 200 * ) Wiring to lampholder 75 200 Main transformer in CG 102 110 Supply terminal in CG 48 > 85 * ) * ) depend on the component cert. temperature rating. The figure is normal temperature rating for such parts. Rev. page. ver. #2 2012-09-19