EM DC Multi-Function DC Energy Meter

Similar documents
Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

premier product range

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Surface mounting, flush mounting, and DIN track mounting

RVS-DN Digital Reduced Voltage Motor Starter

MCD 200 Series Soft Starters

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

DIN Panel Meters Long Scale

DGC-2020 DIGITAL GENSET CONTROLLER

Industrial Power Supplies

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

USERS MANUAL MCD REMOTE OPERATOR

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Electronic timers CT-E range Selection and ordering details

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Technical Data Sheets

Technical Data Sheets

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

SD Series Non-Fused Load Switches

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Technical Data Sheets

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Data Sheets

SonoMeter 30 Energy Meters

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Technical Data Sheets

SonoMeter 30 Energy Meters

Transfer switch OTEC open or delayed transition

CP Automatic capacitor bank

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

AuCom - Soft Starters

Safety technique. Emergency Stop Module BH 5928, BI 5928

CTi Automation - Phone: Fax: Web:

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Plug Into the Current Future

EPS/ELA-Series User Manual EPS/ELA 250W

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Electronic timers CT-S range Function diagrams

Plug Into the Current Future

Digital Time Switches

RVS-DX Digital Reduced Voltage Motor Starter

MIT515, MIT525, MIT1025, MIT1525

SIGMA SERIES DE METER

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

3 Uninterruptible Power Systems

Micro Controller based Motor Protection Relay & Motor Management System

Technical Data Sheet Sigma Series DS Meter

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

INTECH Micro 2300-RTD6

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

AT EVO SERIES BATTERY CHARGER

VSD Series II Variable Speed Micro Drives

3 Uninterruptible Power Systems

OPERATING INSTRUCTIONS ECON-M

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

AT30 SERIES BATTERY CHARGER

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Superstatic 440. Static Heat- and Cooling Meter. Application

Power Conversion System The Best Technology for your photovoltaic and storage system

Cat N 3. OVERALL DIMENSIONS

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Lexium integrated drives

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Scheda prodotto Relè Series E

Acuvim-L Series. Multifunction Power Meter. Max & Min

POWERTRONIX QUASAR 5-40 KVA

OTEC Transfer switch open transition

Electronic pressure switch with integrated analogue output

CAN and Serial Instrumentation

VLM20 In-line Vortex Flowmeter

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Energy Storage System for Home

Transcription:

Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target system. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis www.ziegler-instruments.com 1 6

Block Diagram: Measurement Inputs 1 channel Voltage Timekeeper for time stamping of values Display 4 line 8 digits LED display Relay Outputs 4RO Modbus-RTU Applications: Solar Photovoltaic Systems Battery chargers and systems Wind Power Generation Electroplating Industries Power Distribution for Telecommunication Industrial DC control Systems Measurement Inputs 4 channel Current Standard Optional Power Supply 60-300 V AC/ DC USB-based Serial Port Possible applications of Relay Outputs: Alarming via lamp or horn Load shedding Remote controlling Product Features: Multi-Channel Support: Single meter measures energy consumption of four independent loads connected to one Voltage source Bi-Directional Voltage & Current measurement: The meter has a unique feature of measuring both charging and discharging current Event Logging: Previous 5 Events of factory-default parameters can be logged with Date and Time stamp Data Logging: User Selectable parameters (1 to 30) can be logged at regular intervals (1 to 60 min) with Date & Time stamp in internal memory and can be accessed via Modbus Max Records can vary from 8532 to 91010 depending upon number of selected parameters Load Profile Analysis: Logging of Energy consumed and Peak Demand (Power & Current) in a day and in a month for efficient tracking of load behaviour Daily Data is available for last 1 year and Monthly Data is available for last 14 years Direct Remote Access (optional): Remote configuration of the Instrument and access of measured parameters via MODBUS Programmable baud rates up to 57.6kbps Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen 4 - line 8 digit Ultra-bright LED Display: 4 - line LED display provides easily readable data on meter front with a display range of 99999999 Reverse Locking: Energy and Ampere Hour accumulation can be blocked for Reverse Power and Current resp. Reverse condition can be set as Import or Export Onsite Configuration: Configuration can be done via Front Keys, USB-based Serial Interface or RS485 ( MODBUS) Relay Functions: Limit Switch - For protection against over-shoot or under-shoot of any selected parameter Pulse Output - To drive an external counter for energy measurement Timer - Cyclic ON-OFF operation of relay for user-defined cycles with programmable ON-OFF Delays Remote Operation - Relays can be activated remotely via Modbus Reverse Locking Alarm RTC Relay - Relay can be activated & deactivated at predefined ON & OFF Time on any or all Days of Week Enclosure Protection for dust and water: Conforms to IP 54 (front face) as per IEC60529 Compliance to International Safety standards: Compliance to International Safety standard IEC 61010-1 - 2010 EMC Compatibility: Compliance to International standard IEC 61326-2012 www.ziegler-instruments.com 2 6

96mm 92mm+0.8 EM DC Technical Specifications: Dimensions Details: 96 mm Input Voltage: Nominal Input Voltage Range 10 ~ 60 VDC 61 ~ 200 VDC 201 ~ 1000 VDC Display Area Max continuous input voltage 125% of nominal value Input Current: No of Channels 4 Current Sensor External Shunt Shunt Setting Range 50 ~ 150 mv Full Scale Setting Range Max continuous input current Operating Measuring Range: 1 A to 20 ka 125% of nominal value Front View 3.15 80mm Voltage Current ±2 to ±125% of nominal value ±0.2 to ±125% of nominal value Auxiliary Supply: Higher Aux 60 V 300 V AC- DC, 45 to 65 Hz range Nominal Value 230 V AC- DC, 50/60 Hz for AC Aux VA Burden: Side View 92mm+0.8 Panel Cutout Nominal input voltage burden < 0.4 W approx. Nominal input current burden < 0.1 W approx. per channel Auxiliary Supply burden < 6 VA approx Accuracy: Reference Conditions 23 C +/- 2 C Voltage ±0.5% of Nominal value (±5 to ±120%) Current ±0.5% of Nominal value (±5 to ±120%) Power ±0.5% of Nominal value (±5 to ±120%) Energy Class 1 Temperature Drift 0.05%/ C Display: Type 4 line 8-digit LED Display Display Height 9 mm Overload Indication -ol- (Above 126% of nominal value) Display Range: Voltage 0 to ±9999 Current 0 to ±9999 Power 0 to ±9999 Energy (Import & Export) 0 to 99999999 Relay Output: Max Load Voltage 250 VAC / 30 VDC Max Load Current 5 A Real Time Clock ( RTC): Uncertainty ±2 minutes / month (23 C +/- 2 C) NOTE: Variation due to influence Quantity is 100% of class index www.ziegler-instruments.com 3 6

Installation: Meter PANEL Electrical Connection: LOAD 1 LOAD 2 LOAD 3 LOAD 4 SLIDE IN THIS DIRECTION AND LOCK Vdc- Shunt Vdc+ 2 5 8 11 1 3 4 6 7 9 V+ V- I1+ I1- I2+ I2- I3+ I3- I4+ I4- Aux Supply 13 14 L N Technical Specifications: Optional RS485 Communication: Protocol Modbus-RTU Baud rate 4800, 9600, 19200, 38400, 57600 bps Distance 1200 m Overload Withstand: Voltage 2 x rated value for 1 second, repeated 10 times at 10 second intervals Current 20x rated value for 1 second, repeated 5 times at 5 min intervals Applicable Standards: EMC IEC 61326-2012 Immunity IEC 61000-4-3. 10V/m min Level 3 industrial Low level Safety IEC 61010-1-2010, Permanently connected use IP for water & dust IEC 60529 ( IP 54) Pollution degree 2 Installation category 1000V CATII, 600V CATIII (Measuring Inputs) Protective Class 2 High Voltage Test ( AC 50Hz, 1 minute) Environmental: Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Number of Sweep Cycles 300V CATIII (Power Supply) 4.4 kv AC, Enclosure versus all electrical circuits 3.7 kv AC, Auxiliary Supply versus all other electrical circuits 2.2 kv AC, Measuring Terminals versus all other electrical circuits 2.2 kv AC, Relay versus Relay 2.2 kv AC, USB & RS485 versus all other electrical circuits -10 to +55 C -20 to +70 C 0... 90% non condensing Minimum 3 minute 15g in 3 planes 10... 55...10 Hz, 0.15mm amplitude 10 per axis Dimensions & Weights : Bezel Size 96 mm x 96 mm DIN 43 718 Panel Cut-out 92 + 0.8 mm x 92 + 0.8 mm Overall Depth 80 mm Weight 620 gm. approx. It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5mm. Permissible cross section of the connections wires: <= 4.0 mm sqr. single wire or 2x2.5mm sqr. fine wire www.ziegler-instruments.com 4 6

Measured Parameters: Sr No Parameters Sr No Parameters 1 Voltage 2 Current channel 1 3 Current channel 2 4 Current channel 3 5 Current channel 4 6 Total Import & Export Power 7 Power channel 1 8 Power channel 2 9 Power channel 3 10 Power channel 4 11 Total Import & Export Energy 12 Import and Export Energy channel 1 13 Import and Export Energy channel 2 14 Import and Export Energy channel 3 15 Import and Export Energy channel 4 16 Total Import & Export Ampere Hour 17 Import and Export Ampere Hour channel 1 18 Import and Export Ampere Hour channel 2 19 Import and Export Ampere Hour channel 3 20 Import and Export Ampere Hour channel 4 21 Total Import & Export Power Demand 22 Import and Export Power Demand channel 1 23 Import and Export Power Demand channel 2 24 Import and Export Power Demand channel 3 25 Import and Export Power Demand channel 4 26 27 28 29 30 Total Import & Export Current Demand Import and Export CurrentDemand channel 1 Import and Export CurrentDemand channel 2 Import and Export CurrentDemand channel 3 Import and Export CurrentDemand channel 4 31 On Hour 32 Run Hour channel 1 33 Run Hour channel 2 34 35 Run Hour channel 3 Run Hour channel 4 36 Max and Min Voltage 37 Max and Min Current channel 1 38 Max and Min Current channel 2 39 Max and Min Current channel 3 40 Max and Min Current channel 4 41 42 43 44 45 46 47 48 Max Import and Export Power Demand channel 1 Max Import and Export Power Demand channel 2 Max Import and Export Power Demand channel 3 Max Import and Export Power Demand channel 4 Max Import and Export Current Demand channel 1 Max Import and Export Current Demand channel 2 Max Import and Export Current Demand channel 3 Max Import and Export Current Demand channel 4 49 Number of Interrruptions 50 51 52 53 54 55 56 57 58 59 60 61 62 Old Import and Export Energy channel 1 Old Import and Export Energy channel 2 Old Import and Export Energy channel 3 Old Import and Export Energy channel 4 Old Import and Export Ampere Hour channel 1 Old Import and Export Ampere Hour channel 2 Old Import and Export Ampere Hour channel 3 Old Import and Export Ampere Hour channel 4 Old Max Import and Export Power Demand channel 1 Old Max Import and Export Power Demand channel 2 Old Max Import and Export Power Demand channel 3 Old Max Import and Export Power Demand channel 4 Old Max Import and Export Current Demand channel 1 63 Old Max Import and Export Current Demand channel 2 64 Old Max Import and Export Current Demand channel 3 65 Old Max Import and Export Current Demand channel 4 66 Old On Hour 67 Old Run Hour channel 1 68 Old Run Hour channel 2 69 Old Run Hour channel 3 70 Old Run Hour channel 4 71 Old Number of Interruptions www.ziegler-instruments.com 5 6

Ordering Information: Order Code Example: Ziegler EM DC - 4-400 - 200 - HA - C - 2R Ziegler EM DC 4 Channel, with MODBUS ( RS485) communication, 2 relay outputs. Ziegler Instruments Order No. PQC 96 Data sheet-e1.r0-920507-31-2013-en www.ziegler-instruments.com 6 6 Version: 1/01/II/X/0410