ALPHA ATEX APPROVED DIESEL PUMP

Similar documents
Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT. Applies to the following models only: - FC.TGE - FC.OCIO

Technical Data PR VALVE PRESSURE REGULATING VALVE

TRANSFER PUMP 120 LPM 230V AC

Zone 1 Linear Range - Installation Guide

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

GL1200T Cut & Seal. (GL1200 Seal only)

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

JABSCO & Series 1½ 80 SIZE UTILITY Pump

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

ECONOMISER SERIES E2T USER MANUAL

Pressure Transmitters

KMP Insulation-Continuity Tester. Users Manual

Operating Instruction for Flowmonitor. Model: DF-WM

Floodlight Range Installation Guide

M4 Troubleshooting 42

Tina 4A Connection block

Watermaster Exterior Socket (Part Number ES1001 or ES5001) Vehicle Wall Outside Caravan. Dust Cover. Water Container

DC Master 24/ A

SUBMERSIBLE WATER PUMP

DUAL DIGIT COUNTDOWN TIMER MANUAL

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

INSPECTIONS AND MAINTENANCE

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

TECHNICAL DATA HYDRAULIC UNIT

Tina 10A/B/C Adaptor unit

FMC-1/2 Tina Muting unit

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Tina 11A Connection block

3200NT Timer Service Manual

QSI (Q-Star) Electronics Owner s Manual

BMRX Series ROTARY LEVEL CONTROL

Signet Pressure Transmitter

HILLSTONE DC LOAD BANK

Installation Instructions. Y-Series Brushless Servo Motor

Model 124 Filter Minder & Model 124

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

EC200 ELECTRONIC CONTROL SYSTEM

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

Technical Documentation

USER MANUAL. Insulation Tester + DMM. Model MG320

Exterior Pump Range INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

INSTRUCTION AND USE MANUAL

A Member of the. Integrated Metering Technologies

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Multi-Mover Charger for model L25

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Battery Charger JCB-FCH20LI2

Navigator 550 Sodium wet-section

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Signet Pressure Transmitter

HIGH CAPACITY POWER VENT KIT

Operating Instructions

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Meter FMT II. Operating manual. original operating manual. Translation of the

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

SAX Electronic Valve Actuator

OPERATION & MAINTENANCE INSTRUCTIONS

Mini Hi-Fi System *MFL * SIMPLE MANUAL

Battery Charger JCB- SCH20LI.2

ILED Aquarius Illuminated Windsock. User Manual

80 Litre Suction Oil Drainer With Inspection Chamber

Operating instructions

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Flameproof Level Sensor (Flameproof F/S FP)

Electro-hydraulic actuators for valves

102 Differential Pressure Switch

Declaration of Conformity

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

DALI 650mA LED Driver

Date received into service; / /.

ZB0050 / ZB0051 ZB0070 / ZB0071

SmartPak Welding Controller WK-MPS-16 Constant Current

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

Grant Grid-Connected Inverter For Grant Solar PV Systems. Installation & User Instructions

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Design and application

Model LA 4300 Time Delay OFF Controller

EStrong-series Emergency Stop

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

PSU EN54-4 Power Supplies

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

362 Clamp Meter. Users Manual

Transcription:

Technical Data ALPHA ATEX APPROVED DIESEL PUMP Applies to the following models only: -ALPHA/50A -ALPHA/50FA -ALPHA/50LA -ALPHA/70A -ALPHA/70FA -ALPHA/70LA -ALPHA/90A -ALPHA/90FA -ALPHA/90LA Please read carefully before commencing installation Registered Office: HYTEK (GB) LIMITED, Delta House, Green Street, Elsenham, Bishop s Stortford CM22 6DS UK. Registered in England No. 1915382 Tel: +44 (0) 1279 815 600 Fax: +44 (0) 1279 812 978 email: info@hytekgb.com Web: www.hytekgb.com

ENVIRONMENTAL INFORMATION European Directive 2012/19/EU requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product must be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. PRODUCT DESCRIPTION This pump is ATEX certified to dispense diesel or other liquids classed as category 3 in accordance with European Regulation No. 1272/2008. It bears the following certification marking and number: MANUFACTURED TO: EN13617-1 CERTIFICATE NO: CML 15ATEX9183 2503 II 2 G IMPORTANT WARNING NOTES 1. On above ground storage tanks an angle check valve fitted with the appropriate spring or pressure regulating valve must be fitted at the tank outlet to prevent loss of fuel under gravity in the event of vandalism or accidental damage. 2. This pump must only be used to dispense diesel or other liquids classed as category 3 in accordance with European Regulation No. 1272/2008. It must not be used to dispense petrol or any other liquid with a similar flash point. 3. Installation of this equipment and its associated tank, pipe work and fittings should only be carried out by qualified fuel installation engineers.

4. The installation must be carried out in accordance with the requirements of EN 60079-14 the latest relevant electrical and local authority regulations and standards. 5. It must not be used with other liquids or for other applications. We will accept no warranty claims or liability if it is used for other liquids or applications. RATION The meter on this pump unit must be calibrated electronically to ensure accuracy and reliability.

INSTALLATION INSTRUCTIONS 1. Check you have the following items: 1 off Alpha pump 1 off delivery hose 1 off front door key 2. Open the front panel using the key provided. 3. Remove the rear panel, if necessary, and store safely. MOUNTING 4. Bolt the pump to a firm level foundation by means of the four 14 mm diameter-mounting holes provided. NB: If the optional drip tray is to be fitted to the pump it must be sealed to its foundation, with a suitable elastomeric substance, to prevent leaked fuel "wicking" back underneath the pump. To maintain the environmental integrity of the drip tray any possible leak path through the pump mounting holes must also be sealed.

PIPEWORK 5. Connect the 11/2 diameter pipe from the tank to the suction inlet flexible connector of the pump. The inlet thread of the flexible connector flange is 11/2 BSP taper female. Seal the joints with a suitable thread sealing compound. The pipe work must be sealed to the drip tray (if fitted) to ensure no leaking fuel can flow underground. An alternative pipe work entry point, for above ground pipe work, is provided at the rear of the pump base. Push out the plastic cover plate if required. NB:On above ground tanks an angle check valve fitted with the appropriate spring or an anti-syphon valve must be fitted in the suction line to prevent spillage or leakage in the event of damage. 6. Connect the delivery hose and selected ATEX approved nozzle to the pump outlet in accordance with the instructions supplied with the individual components. Ensure the nylon hose-sealing washers are in place on the hose end. It should be hand tight plus a quarter turn.

ELECTRICAL 7. Remove the covers from the junction box. 8. Connect a constant 220/240V AC 50 Hz supply, fused at 16 amps, to the terminal block in the junction box as shown on the wiring details diagram. NB:The Alpha pump must have a continual 220/240V AC supply, even when not in use 9. If the Alpha is to be operated in conjunction with a key/card system, remove the link in the junction box (shown on the Alpha Installation Wiring Diagram) and connect so that the control system makes and breaks the connection. Make connection - Pump on Break connection - Pump off Alternatively remove the link and connect a switched live supply (230V AC 16A max.) to terminal 4 (shown on the Alpha Installation Wiring Diagram) Live supply switched on - Pump on Live supply switched off - Pump off 10. A pulse output for connection to key/card systems is available from the separate terminals located in the junction box. This is a passive contact giving 10 or 100 pulses per litre. Contact ratings are as follows: Maximum current - 0.25 amps Maximum voltage - 50 volts Maximum power - 5 VA 11. Ensure all the terminal screws are tight and replace the junction box covers.

INSTRUCTIONS FOR USE 1. Remove the nozzle from the holster. 2. Place the nozzle spout in the fuel tank. 3. Squeeze the nozzle trigger to dispense fuel. On completion of the delivery release the trigger and replace the nozzle in the holster.

MAINTENANCE The Alpha should require minimum maintenance in normal regular use, but as with all mechanical apparatus regular servicing will prolong its life and ensure maximum efficiency & reliability. The following should be carried out every 12 months or 1 million litres which ever comes first. - Isolate power supply - Inspect & clean or replace pump filter - Inspect & clean or replace nozzle filter - Inspect & replace if necessary the V-belt - Check motor pulley grub screw is tight - Re-calibrate electronic display

44 105 460 396 340 32 ALPHA BASE AND SUCTION CONNECTION DIAGRAMS BASE VIEW FROM ABOVE FRONT 526 500 13 FOUR 15MM DIA. MOUNTING HOLES ALL DIMENSIONS IN MM SUCTION INLET LOCATION 215 REAR VIEW 1 1/2" STAINLESS STEEL FLEXIBLE CONNECTOR (SUPPLIED AS STANDARD) 1 1/2" BSP TAPER FEMALE THREADED STANDARD TRIANGULAR SUCTION FLANGE ALIGNED WITH SUCTION HOLE IN BASE 82 133 76.5MM DIA. ALTERNATIVE SUCTION HOLE SLOTTED TO BOTTOM OF BASE 22MM DIA. ALTERNATIVE CABLE ENTRY HOLE

COM REL OPT ALPHA INSTALLATION WIRING DIAGRAM ALPHA MAIN JUNCTION BOX INSTALLATION WIRING DETAILS 220/240V CONNECTIONS PULSE OUTPUT CONNECTIONS 230V MOTOR OUTPUT AUTH. 220-240V INPUT PULSE OUTPUT ALTERNATIVE PUMP CONTROL - KEY/CARD L CONTROL SYSTEM SWITCHED LIVE SUPPLY 220/240V AC 16 A MAX E L N 1 2 3 4 5 * L 6 N 7 E 8 1 2 3 OPTO ISOLATED KEY/CARD CONTROL RELAY SYSTEM PULSE INPUT TERMINALS COMMON 50V 0.25A MAX KEY/CARD CONTROL SYSTEM RELAY 220/240V AC 16A MAX * SUPPLIED WITH LINK FITTED BETWEEN TERMINALS 4 AND 5. REMOVE LINK FOR REMOTE KEY/CARD CONTROL E N L CONSTANT SUPPLY 220 / 240V AC FUSE - 16A

ALPHA EXTERNAL DIMENSIONS SIDE NOZZLE HOLSTER ALPHA EXTERNAL DIMENSIONS FRONT NOZZLE HOLSTER

ALPHA SIDE ACCESS PANEL VIEW 33 20 34 21 25 ALPHA PUMP UNIT FILTER LOCATION PUMP UNIT FILTER LOCATION AS VIEWED FROM THE FRONT

FEATURES ELECTRONIC DISPLAY/CALCULATOR 6-digit backlit Main LCD display: 8-digit backlit totaliser LCD display: Up to 9999.99 or 99999.9 litres per delivery Up to 99999999 litres Display retained during power failure OPERATION Stand-by mode: Nozzle removed: Fuel drawn: Nozzle Returned: Upper line of LCD display shows previous delivery Lower line of LCD display shows ongoing total Upper line shows all eights then all zeros Lower line shows FUELLING Pump starts Upper line shows litres dispensed Lower line shows FUELLING Pump stops Upper line of LCD display shows previous delivery Lower line of LCD display shows ongoing total

RATION PROCEDURE - (MUST BE CARRIED OUT TO ENSURE PUMP ACCURACY) 1. Ensure the nozzle is stowed in the holster and the dispenser is isolated from any fuel management systems. 2. Remove calibration button cover bolt from rear of display / calculator housing (if fitted). 3. Gently push and hold the calibration button using a small screwdriver or similar tool.

4. Release the calibration button when the totaliser display shows VER followed by the version number on the lower line of the display. 5. The lower line will show the following in a looping sequence: 1 PULSE CHANNEL - Single channel pulser connected 2 PULSE CHANNEL - Two channel pulser connected REED PULSER - Reed switch pulser connected Press calibration button once when desired option is displayed. Select 2 PULSE CHANNEL for Weights & Measures Alpha, REED PULSER for Alpha fitted with PULS.E18 reed switch pulser (pre August 2003) or Adblue Alpha and 1 PULSE CHANNEL for all other Alpha versions. 6. The lower line will show the following in a looping sequence: LITRES Display measures in litres. GALLONS Display measures in gallons (Imperial or US) Press calibration button once when desired option is displayed. 7. The lower line will show the following in a looping sequence: BACKLIGHT ON backlight on constantly. BACKLIGHT OFF backlight off. ON FOR FUELLING backlight only on during fuelling. Press calibration button once when desired option is displayed.

8. The lower line will show the following in a looping sequence: 1 DECIMAL PLACE - One decimal place on display 2 DECIMAL PLACE - Two decimal places on display Press calibration button once when desired option is displayed. 9. The lower line will show the following in a looping sequence: REED RELAY 10 - Ten pulse per litre reed relay output. OPTO OUTPUT 10 - Ten pulse per litre opto-isolated output. OPTO OUTPUT 100 - One hundred pulse per litre opto-isolated output. Press calibration button once when desired option is displayed. 10. The lower line will show the following in a looping sequence: TANK SW UNUSED No tank empty switch connected. TANK SW IS TA.F Tank empty switch connected is Hytek TA.F type* (*Feature coming soon) TANK SW NOT TA.F Tank empty switch connected is standard normally closed float switch* (*Feature coming soon) 11. The lower line will show the following in a looping sequence: LEAK SW UNUSED No pump leak switch connected. LEAK SW IS TA.F pump leak switch connected is Hytek TA.F type* (*Feature coming soon) LEAK SW NOT TA.F pump leak switch connected is standard normally open float switch* (*Feature coming soon)

12. The lower line will show the following In a looping sequence: NOZ 2 SW UNUSED No additional /remote nozzle switch connected. 2nd NOZ SW N/O Additional nozzle switch is normally open type. 2nd NOZ SW N/C Additional nozzle switch is normally closed type. 13. The lower line will show the following in a looping sequence: STAND ALONE - Pump external serial interface not used. SELECT THIS OPTION CONFIG NETWORK Configure serial network. DO NOT SELECT 14. The lower line will show the following in a looping sequence: SAVE AND EXIT Save all settings entered and return to normal operation. RATE PUMP Continue and calibrate pump with 20 litre measure. ABANDON CONFIG Do not save any settings entered and return to normal operation. 15. If RATE PUMP was selected TAKE NOZZLE will be shown. Take the nozzle (the lower line will show DISPENSE 20L) and dispense 20 litres into a calibrated test measure. 16. Once 20 litres have been dispensed hang up the nozzle. The lower line should show RATION OK. If there is an error in the calibration the relevant error message will be displayed.

ERRORS If an error occurs ERROR, followed by a brief description is shown on the lower display. The errors are classified as follows: FLOW TOO FAST The pulser has run too fast (in excess of 300 pulses per second) UNAUTH FLOW The meter has turned without the nozzle being removed RATE FAIL A time delay of 2 minutes or more has occurred during the 20 litre calibration. PULSER SIGNAL One of the pulse transmitter s pulse trains has been interrupted. PULSE REVERSE The meter has run backwards during a delivery PULSER POWER The pulser has been disconnected The error condition is maintained until the nozzle is returned to its holster, for at least 2 seconds, and then removed again to restart the fuelling sequence. TIMEOUT If, during a delivery, no fuel is dispensed for 2 minutes the display will show TIMEOUT alternating with REPLACE NOZZLE and the pump will stop running until the nozzle is returned to its holster, for at least 2 seconds, and then removed again to restart the fuelling sequence.

1 2 3 1 2 YELLOW GREEN/BLUE RED COMMON - BROWN REED RELAY - BLUE OPTO ISOLATED - GRN/YEL +12VDC - BROWN 0V - BLUE +12VDC - RED (W&M GREEN) CH 1 - YELLOW (W&M WHITE) CH 2 - GREEN (W&M YELLOW) 0V - BLACK (W&M BROWN) AND SCRN DISPLAY CONNECTION DIAGRAM 220/240 VAC POWER INPUT NEUTRAL EARTH LIVE AC INPUT DISPLAY / CALCULATOR VIEWED FROM REAR RATION BUTTON 220/240 VAC MOTOR RELAY OUTPUT NEUTRAL - GREY LIVE - BLACK PUMP NOZZLE P/OUT SOLENOID SWITCHES PULSE IN COMMS GND IN 12V COM REED OPT 12V GND TANK LEAK EXT +12V CH1 CH2 GND GND + - GND SW GND SW GND SW DC 1 2 3 1 2 3 1 2 1 2 3 4 5 6 1 2 3 4 1 2 3 NOZZLE SWITCH INPUT 10:1 / 100:1 PULSE OUTPUT 12V DC SOL. OUTPUT (WEIGHTS & MEASURES VERSION ONLY) PULSE TRANSMITTER INPUT

ALPHA EXTERNAL VIEW 8 1 11 3 5 2 10 6 9 7

ALPHA INTERNAL VIEW 27 14 26/31 28 15 22 32 16 18 19 17 30 29

DRG. REF PART DESCRIPTION ALPHA PARTS LIST PART NO. A50/A70 PART NO. A90 EXTERNAL COMPONENTS 1 LCD DISPLAY UNIT ALP.DISP.PCB.3A ALP.DISP.PCB.3A (Above item includes LCD, transformer board and fitting kit) 2 LOCK (x 2) ALP.LOCK3 ALP.LOCK3 3 NOZZLE HOLSTER WITH SWITCH ALP.NOZBOOT.A ALP.NOZBOOT.A 4 DOOR KEY 209.KEY 209.KEY 5 OUTLET ELBOW ELB.4FFCR ELB.4FFCR 6 SIDE ACCESS PANEL ALP.ACCPAN3 ALP.ACCPAN3 7 MOUNTING BASE ALP.BASE3 ALP.BASE3 8 TOP CAP ALP.CAP3 ALP.CAP3 9 DOOR ALP.DOORASS3 ALP.DOORASS3A DOOR (FRONT NOZZLE OPTION)* ALP.DOORASS.F3 ALP.DOORASS.F3A 10 SIDE PANEL ALP.SPAN.BL3 ALP.SPAN.BL3 11 SIDE PANEL WITH HOSE OUTLET ALP.SPANH3 ALP.SPANH3 SIDE PANEL WITH HOSE OUTLET (FRONT NOZZLE OPTION) ALP.SPANH.F3 ALP.SPANH.F3 INTERNAL COMPONENTS 14 DOOR STAY ALP.DSTAY3 ALP.DSTAY3 15 PULSER PULS.30A PULS.30A 16 AIR SEPARATOR OUTLET FLOAT CHAMBER MINIVENT MINIVENT 17 MOTOR MOT.E75.ATEX MOT.E75.ATEX 18 4 PISTON METER 209A.METER.REP 209A.METER.REP (2 REV PER LITRE) 19 PUMP UNIT (COMPLETE) 209A.PASSY 209A.PASSY 20 PULLEY BELT VBLT.28 VBLT.285 21 PULLEY PULL.25C PULL.3C 22 METER OUTLET PIPE ALP.OUTPIPE.W ALP.OUTPIPE.W 23 INLET FLANGE* FLNG FLNG 24 INLET GASKET* GSK.TRI GSK.TRI 25 FLEXIBLE SUCTION CONNECTOR TTLB TTLB 26 RELAY (INSIDE JUNCTION BOX) ALP.RELAY ALP.RELAY 27 UPPER PANEL (x 2) ALP.UPAN3 ALP.UPAN3 28 DISPLAY COVER ALP.DISPCOV3 ALP.DISPCOV3A 29 PUMP MOUNTING FRAME (x 2) ALP.PFRAME3 ALP.PFRAME3 30 PUMP MOUNTING PLATE (x 2) ALP.PPLATE3 ALP.PPLATE3 31 JUNCTION BOX ALP.DBOX3 ALP.DBOX3 32 OUTLET CHECK VALVE CHK.1A.DRILL CHK.1A.DRILL 33 CHECK VALVE* 209EP.21 209EP.21 34 BYPASS VALVE* 209EP.29 209EP.29 35 PUMP UNIT VANES* (X 6) 209EP.38 209EP.38 36 PUMP UNIT FILTER* 209EP.3 209EP.3 *Not shown on illustration

E.U. DECLARATION OF CONFORMITY Company Name: Address: Hytek (GB) Ltd Delta House, Green Street. Elsenham, Bishops Stortford, Hertfordshire, CM22 6DS, UK Date of Issue: 20 th April 2016 Equipment Details: Alpha ATEX Fuel Pumps with Fuel Control ALPHA/50A, ALPHA/50LA, ALPHA/50FA, ALPHA/70A, ALPHA/70LA, ALPHA/70FA, ALPHA/90A, ALPHA/90LA, ALPHA/90FA, ALPHA/5050A, ALPHA/5070A, ALPHA/5090A, ALPHA/7070A, ALPHA/7090A, ALPHA/9090A Applicable Directives: 2004/108/EC EMC Directive & & Standards 2014/30/EU EMC Directive (effective date 20 th April 2016) EN 61000-6-3:2007 (+A1) Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission std. for residential, commercial & light-industrial environments EN 61000-6-2:2005 Electromagnetic compatibility (EMC) Part 6-2: Generic standards - Immunity for industrial environments 2014/35/EU Low Voltage Directive 2006/42/EC Machinery Directive 97/23/EC Pressure Equipment Directive & 2014/68/EU Pressure Equipment Directive (effective 19 th July 2016) 2012/19/EU Waste Electrical & Electronic Equipment Regulations 2011/65/EU Restriction of Hazardous Substances Directive (RoHS2) Declaration Number: 94/9/EC ATEX Directive & 2014/34/EU ATEX Directive (effective date 20 th April 2016) EN 13617-1:2012 & EN 1127-1:2011 EC Type examination Certificate No.: CML 15ATEX9183 Marking: Ex II 2 G EN 13617-1:2012 Ta= -20 C to + 40 C Notified Body: CML Ltd. Number 2503 Unit 1 Newport Business Park, New Port Road Ellesmere Port, CH65 4LZ UK EU124/5 On behalf of the above named company, I declare under our sole responsibility that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms with all technical and regulatory requirements of the above listed directives. Clive Wellings, Technical Manager THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROTECTED BY COPYRIGHT AND PROPERTY LAWS AND IS THE SOLE PROPERTY OF HYTEK (GB) LTD. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HYTEK (GB) LTD IS PROHIBITED.