LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Similar documents
Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

EPOXY POWDER COATED COPPER FREE ALUMINUM

Taxonomies, Classifications, and Categories MYER'S HUB, 3-PIECE COUPLINGS, THREADLESS COUPLINGS AND THREADLESS CONNECTORS

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

Rigid/Aluminum Conduit Bodies, Gaskets and Covers

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

TCI5125 Dusttight Grip " 1.50"NPT Ins

CONDUIT BODIES CONDUIT BODIES. Phone:

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Conduit Bushings for Rigid Metal Conduit and IMC

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

ALUMINUM OUTLET BODIES

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

VR A 3W 4P Receptacle. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Applications. Standard Materials

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Spring-loaded cover seats against neoprene gasket.

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Uses, Certifications, and Standards STRUT FITTINGS,BF-FTGS,MISCELLANEOUS

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

SW Tog DP 30A 120/277V Autogrd B&S WH

4 Square Partition Square Cut Tile Wall 2 Gang Cover 2 1/8 Deep 1/2 to 1 RSD

Condulet Cast Device Boxes and Covers Application and Selection

N0N A 250V One-Time Class H Fuse

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Cable Connectors & Conduit Sealing Bushings

Corrosion Protection for Electrical Conduit and Fittings

5-1/2 INCH L X 4-1/8 INCH W X 6 INCH H

Condulet Conduit Bodies and Outlet Boxes Hazardous

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

General Cable Support Information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Cable Connectors & Conduit Sealing Bushings

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

PGL350P W PS Wallpack

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Commercial Products. New Products in the Commercial Products Product Line

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

Junction Boxes Hazardous and Non-Hazardous

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

TA Ta VA CTRL-XFRMR

Lighting: Explosionproof Area HID. Applications. Standard Materials

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Plugs and Receptacles: Hazardous Location

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

AE Series Pin and Sleeve Plugs, Connectors and Receptacles Weatherproof 600 Vac, 250 Vdc. Pressure Wire Terminals.

Rigid Metal Conduit, IMC or EMT K-Clamps

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features connection Form Material Material, Color, and Finish Finish LB125A Appleton/Oz Gedney Form 85 Unilets Type LB Conduit Outlet Body, : 1-1/4 In, Form: 85, Length: 7.88 In, Height: 3.88 In, Material: Pressure Cast Aluminum, Finish: Epoxy Powder Coat, Connection: Tapered Female Threaded, Standard: Ul 514A, Ul 514B, Ul File Number E2527, Csa C22.2 No. 18.3, Csa 065183, Nema FB-1, For Use With Rigid Steel, Rigid Aluminum Conduit, Imc and Emt 1.3 (lbs/each) Alum Tapered Female Threaded 85 W Pressure Cast Aluminum EPOXY POWDER COATED Dimensions and Weight Height STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT 1.25 IN Length 78379514825 Descriptions Description 1-1/4" LB FORM 5 ALUMINUM CONDUIT BODY Long Description Form 85 UNILETS Type LB Conduit Outlet Body, : 1-1/4 IN, Form: 85, Length: 7.88 IN, Height: 3.88 IN, Material: Pressure Cast Aluminum, Finish: Epoxy Powder Coat, Connection: Tapered Female Threaded, Standard: UL 514A, UL 514B, UL File Number E2527, CSA C22.2 No. 18.3, CSA 065183, NEMA FB-1, For Use With Rigid Steel, Rigid Aluminum Conduit, IMC And EMT Product Type 1 1/4 Type LB Form 85 Uni (A) special features Serve as pulling fittings; Make bends in conduit system; Provide openings for splicing; Connect and change direction of conduit runs; Allow connections for branch runs; Permit access to conductors for maintenance; Smooth, rounded integral bushings in hubs protect conductor insulation; Roomy interiors: more wiring space; Accurately tapped, tapered threads for tight, rigid joints and excellent ground continuity; Form 85 copper free aluminum Unilets are lightweight, self oxidizing, self-renewing and offer a h

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Manufacturer Information Brand APPLETON GTIN 00781381476508 Manufacturers Part Number LB125-A sub brand UNILETS UPC 781381476508 Taxonomies, Classifications, and Categories Category Description FORM 5 CONDULETS, COVERS, & GASKETS Type Type LB Conduit Outlet Body Packaging Carton 1 Package 20 Weight Per each 1.2999 Uses, Certifications, and Standards Application For Use With Rigid Steel, Rigid Aluminum Conduit, IMC And EMT standard UL 514A, UL 514B, UL File Number E2527, CSA C22.2 No. 18.3, CSA 065183, NEMA FB-1

Form 85 Unilet Conduit Outlet Bodies For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. Fittings Fittings: Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors for maintenance. Features Roomy interiors: more wiring space. Smooth, rounded integral bushings in hubs protect conductor insulation. Accurately tapped, tapered threads for tight, rigid joints and excellent ground continuity. Form 85 copperfree aluminum Unilets are lightweight, selfoxidizing, self-renewing and offer a high corrosion resistance. Lightweight aluminum facilitates shipping, handling and installing. Sizes with flat-back design ideal where fitting is mounted flat against surface. 1/2" to 3" blank covers are domed for extra wiring space. Standard Materials Bodies: copperfree (max. 4/10 of 1%) aluminum 1/2 thru 2 : pressure cast 2-1/2 thru 4 : sand cast Blank covers: malleable iron, steel or aluminum Cover screws: stainless steel Gaskets: neoprene or composition fiber Standard Finishes Aluminum bodies: epoxy powder coat Stamped aluminum covers: natural finish Cast aluminum covers: epoxy powder coat Certifications and Compliances UL Standards: 514A, 514B UL Listed: E2527 CSA Standard: C22.2 No. 18.3 CSA Certified: 065183 NEMA Standard: FB-1 Options PVC coating available on all threaded bodies and select covers. Add suffix -PVC to catalog number. For fully assembled body, cover and gasket, add suffix -ACGA. Related Products For explosionproof conduit outlet bodies and boxes, see Enclosures and Junction Boxes. Conduit Body with Stamped Aluminum Cover. 2 Type C shown. Typical Form 85 Conduit Bodies with Setscrews. For use with Electrical Metallic Tubing (EMT). 26 September 2010

Form 85 Aluminum Unilet Conduit Outlet Bodies Threaded Type for use with Rigid Metal Conduit and IMC; Setscrew Type for use with Electrical Metallic Tubing (EMT). Appleton Form 85 Conduit Bodies: Threaded/SetScrew Type * Threaded Type C E LB LL Setscrew Threaded Setscrew Threaded Setscrew Threaded Setscrew Type 1/2 C50-A C50T-A E50-A E50T-A LB50-A LB50T-A LL50-A LL50T-A 3/4 C75-A C75T-A E75-A LB75-A LB75T-A LL75-A LL75T-A 1 C100-A C100T-A E100-A LB100-A LB100T-A LL100-A LL100T-A 1-1/4 C125-A C125T-A LB125-A LB125T-A LL125-A LL125T-A 1-1/2 C150-A C150T-A LB150-A LB150T-A LL150-A LL150T-A 2 C200-A LB200-A LB200T-A LL200-A LL200T-A 2-1/2 C250-A LB250-A LL250-A 3 C300-A LB300-A LL300-A 3-1/2 C350-A LB350-A LL350-A 4 C400-A LB400-A LL400-A Threaded Type LR T TB X Setscrew Threaded Setscrew Threaded Setscrew Threaded Setscrew Type Fittings Fittings: Conduit Bodies 1/2 LR50-A LR50T-A T50-A T50T-A TB50-A X50-A 3/4 LR75-A LR75T-A T75-A T75T-A TB75-A X75-A 1 LR100-A LR100T-A T100-A T100T-A TB100-A X100-A 1-1/4 LR125-A LR125T-A T125-A TB125-A 1-1/2 LR150-A LR150T-A T150-A TB150-A 2 LR200-A LR200T-A T200-A TB200-A 2-1/2 LR250-A T250-A 3 LR300-A T300-A 3-1/2 LR350-A T350-A 4 LR400-A T400-A Back Style for Form 85 Unilet Conduit Body Sizes Unilet Body Flat Back Round Back C, LB, LL, LR, T 1/2 2 2-1/2 4 TB 1-1/4, 1-1/2 1/2, 3/4, 1, 2 E, X 1/2 1 * Refer to following page for Wiring Capacity Table. PVC coating available on threaded bodies. Add suffix -PVC to catalog number. September 2010 27

Covers and Gaskets for Form 85 Unilet Conduit Outlet Bodies and Wiring Capacity Covers Furnished with Stainless Steel Fastening Screws. Covers and Gaskets Body Size Blank Stamped Aluminum Blank Cast Aluminum Neoprene Composition Fiber Fittings Domed: 1/2-3 Flat: 1/2-2 FITTINGS: CONDUIT BODIES Flat: 3-1/2-6 Domed: 2-1/2-4 Tear out inner section to convert to open type gasket. 1/2 K50-A K50-CA GK50-N GK50-V 3/4 K75-A K75-CA GK75-N GK75-V 1 K100-A K100-CA GK100-N GK100-V 1-1/4 K125 & 150-A K125 & 150-CA GK125-150-N GK125-150-V 1-1/2 K125 & 150-A K125 & 150-CA GK125-150-N GK125-150-V 2 K200-A K200-CA GK200-N GK200-V 2-1/2 K250 & 300-A K250 & 300-CA GK250-300-N GK-250-300-V 3 K250 & 300-A K250 & 300-CA GK250-300-N GK-250-300-V 3-1/2 K350 & 400-A K350 & 400-CA GK350-400-N GK-350-400-V 4 K350 & 400-A K350 & 400-CA GK350-400-N GK-350-400-V Wiring Capacity: Combine Body and Cover Capacities for Total Usable Capacity per NEC 314.16(A) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Capacity (in 3 /dm 3 ) C E LB LL LR LRL T TA TB X Stamped Cover Cast Cover 143.00/ 2.34 180.00/ 2.95 303.00/ 4.97 340.00/ 5.57 139.00/ 2.28 17 2.90 300.00/ 4.92 330.00/ 5.41 140.50/ 3568.7 175.00/ 2.87 300.00/ 4.92 330.00/ 5.41 14 2.39 185.00/ 3.03 31 5.15 345.00/ 5.65 0.10 13.00/ 0.21 34.50/ 71.00/ 1.16 0.50/ 0.80/ 1.00/ 25.4 0.04 0.04 6.50/ 18.00/ 0.29 18.00/ 0.29 0.00/ 0.00 0.30/ 0.00 0.50/ 0.80/ 0.80/ 1.00/ 0.02 30.00/ 0.49 30.00/ 0.49 50.00/ 0.82 50.00/ 0.82 Add suffix -PVC to catalog number. 28 November 2011

Form 85 Aluminum Unilet Conduit Outlet Bodies Dimensions Threaded Type for use with Rigid Metal Conduit and IMC; Setscrew Type for use with Electrical Metallic Tubing (EMT). Pressure Cast 1/2 3/4 1 1-1/4 1-1/2 2 Sand Cast 2-1/2 3 3-1/2 4 Types C, T Types E, LB, LL, LR Dimensions In Inches/Millimeters A B C D E F G H J L M N P 3.94/ 100.1 4.63/ 117.6 5.38/ 136.7 9.50/ 241.3 12.25/ 311.2 12.25/ 311.2 14.88/ 378.0 14.88/ 378.0 1.31/ 33.3 1.56/ 39.6 1.81/ 46.0 63.5 63.5 3.13/ 79.5 4.31/ 109.5 4.31/ 109.5 5.50/ 139.7 5.50/ 139.7 1.38/ 35.1 1.63/ 41.4 1.88/ 47.8 3.44/ 87.4 3.88/ 98.6 4.63/ 117.6 5.19/ 131.8 5.56/ 141.2 4.75/ 120.7 5.63/ 143.0 6.69/ 1 8.56/ 217.4 8.56/ 217.4 10.81/ 274.6 15.13/ 384.3 15.13/ 384.3 18.13/ 460.5 18.13/ 460.5 2.56/ 65.0 3.00/ 76.2 8.75/ 222.3 8.75/ 222.3 2.00/ 50.8 2.25/ 57.2 2.63/ 66.8 4.19/ 106.4 5.75/ 146.1 5.75/ 146.1 7.13/ 181.1 7.13/ 181.1 2.06/ 52.3 2.44/ 62.0 2.81/ 71.4 3.88/ 98.6 3.81/ 96.8 4.56/ 115.8 5.25/ 133.4 6.81/ 173.0 4.13/ 104.9 4.88/ 124.0 6.56/ 166.6 6.44/ 163.6 8.31/ 211.1 11.88/ 301.8 11.56/ 293.6 1 355.6 13.75/ 349.3 4.31/ 109.5 5.13/ 130.3 7.88/ 200.2 7.88/ 200.2 1/ 258.8 13.69/ 347.7 13.69/ 347.7 16.50/ 419.1 16.50/ 419.1 0.63/ 16.0 0.75/ 19.1 0.94/ 23.9 1.06/ 26.9 1.19/ 30.2 1.50/ 38.1 1.81/ 46.0 2.19/ 55.6 63.5 1.13/ 28.7 1.38/ 35.1 1.69/ 42.9 2.13/ 54.1 2.38/ 60.5 2.94/ 74.7 3.38/ 85.9 4.13/ 104.9 4.75/ 120.7 5.13/ 130.3 3.14/ 79.8 3.78/ 96.0 4.50/ 114.3 8.06/ 204.7 10.63/ 270.0 10.63/ 270.0 13.13/ 333.5 13.13/ 333.5 1.05/ 26.7 1.27/ 32.3 1.52/ 38.6 2.25/ 57.2 2.25/ 57.2 3.69/ 93.7 3.69/ 93.7 4.88/ 124.0 4.88/ 124.0 Fittings Fittings: Conduit Bodies September 2010 29