Sigma Series Systems

Similar documents
Alpha Series Systems

Alpha Series Systems

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

ARGONITE Fire Protection Systems

HPCO 2. Fire Extinguishing System

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library

INERGEN. 150-BAR SYSTEMS Design, Installation, Recharge, and Maintenance Manual

Table 1. Table 2. Table 3: Toxicology/Environmental FM-200 (UL/FM) 14A-07H SECTION 1 - INTRODUCTION. Agent Physical Properties FM-200

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

Cylinder Valve Assembly Series

Component Sheet Library

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

Instructions for Installation, Operation, Care and Maintenance

FireFlex DUAL Single Interlock, Remote controlled system

B21 Series BASOTROL Gas Valve

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

Powers Controls Powertop Two-Way Valves Normally Open

Locktite Manual Reset Gas Shut-Off Valves

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

FYJR.EX Carbon Dioxide Extinguishing System Units, General Use. Carbon Dioxide Extinguishing System Units, General Use

Model RM-1 Riser Manifold Commercial and Residential General Description

Kidde Engineered Fire Suppression System

HEAD VALVE. Model No.: NF 40/600V, NF 40/360V DESCRIPTION

TECHNICAL DATA 1-1/2 (dn40)

POWERS Controls No. 4 Pneumatic Damper Actuator

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TotalPac 3 Deluge system Pneumatic release

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

VANGUARD A EZ INSTALL OPERATOR S MANUAL

Valves & Flow Control Components Valves & Flow Control Components

VB-9313 Series. Application. Features. Applicable Literature

Marine Carbon Dioxide

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Powers Controls No. 4 Pneumatic Damper Actuator

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Emergency Shear Valves

DELUGE VALVE DATA SHEET

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Bellows-Sealed Valves

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

PNEUMATIC SLIDING VALVE

VB-9313 Series. Application. Features. Applicable Literature

SOLENOID CONTROL VALVE

Electronic Globe Valve Guide Specifications

Protection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES

TECHNICAL DATA. Q= C v P S

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

PRESSURE REDUCING CONTROL VALVES

TotalPac 3 Deluge, Electric release Remote controlled system

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

CONN in mm in mm in mm SIZE lbs kg PX " /4"

BLACKMER BYPASS VALVES

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

PIPING TO HAZARD PIPING TO HAZARD AGENT SOURCE AGENT SOURCE TOP VIEW TOP VIEW

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

Protection Systems. 3-Way Directional Ball Valve P/Ns: X and X. A UTC Fire & Security Company FEATURES

TotalPac 3 Non interlock Preaction system Pneumatic release

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

Instructions for Installation, Operation, Care, and Maintenance

Powers Controls No. 6 Pneumatic Damper Actuator

Powers Controls Powermite Two-Way Flared Valves Normally Open/Normally Closed

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

North American Automatic Manual Reset and Motorized Valves

Be llows-se aled Valve s

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

CHECK VALVES. Flare to Flare. Solder to Solder. Solder to Solder - Extended Ends. Shipped loosely assembled.

A /20/30, LT-A /20/30 VEHICLE SYSTEMS Installation, Recharge, Inspection, and Maintenance Manual

Pressure Relief Valve Maintenance Manual

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

Grooved Piping System for Fire Protection Services

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

SPRAGUE PRODUCTS AIR DRIVEN HYDRAULIC PUMPS

Instrument Ball Valves

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

VB-9213 Series. Application. Features. Applicable Literature

Section R Foam Systems

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Section R Foam Systems

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

SECTION METERS AND GAGES FOR PLUMBING PIPING

CHAPTER III SYSTEM DESIGN

Model 5000 Level Controller

Worldwide Contacts.

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

POWERS TM CONTROLS LC Pneumatic Damper Actuator

Wet pipe low flow foam/water manifold system

Advanced Air Driven Gas Boosters and Amplifiers. Sprague. Air Amplifiers. Gas Boosters

Transcription:

GENERL INFORMTION The Chemetron Fire Systems are automatic suppression systems using the FM-200 chemical agent and consisting of four basic components and their associated accessories. FM-200 Components Completer Kits Detection and larm Devices Control Panels Features 1 2 3 4 The FM-200 components consist of agent containers, container supports (racks), and discharge nozzles. The completer kits consist of warning signs, hoses, connection fittings, pressure gauges or solenoid valves, and the actuator required to operate the cylinder valve. The detection, alarm devices and accessories provide fire detection, audible and visual pre-alarm warnings and annunciation of the FM-200 discharge. The control panel monitors the detection, actuates the alarms, initiates the agent discharge and controls auxiliary functions such as shut down of vital equipment and ventilation dampers. The system and its components are agency tested for total flooding applications and should be used in accordance with the guidelines contained in National Fire Protection ssociation 2001. total flooding application can be defined as injecting FM-200 into an enclosure or volume having the structural integrity to retain the agent during and after discharge. The design of such a system requires that the FM-200 chemical agent be discharged from its container within 10 seconds and be thoroughly mixed throughout the protected volume, reaching a minimum concentration level of 6.25%, but not exceeding 9% in normally occupied spaces. Cylinder and Valve ssembly Sigma Series cylinders are available in three different capacities and are charged with FM-200 to a filling density up to 70 lb/ft 3 3 (1121 kg/m ) of cylinder volume. ll cylinders are superpressurized with dry nitrogen to a pressure of 360 psig (2482 kpa), at 70 F (21 C). Each cylinder is equipped with an identification nameplate indicating the quantity of FM-200. The standard cylinder assembly, having a rigid dip tube, is designed for mounting in a vertical position only. The cylinder assembly is composed of a cylinder, dip tube, and cylinder valve. PULL LEVER MNUL PNEUMTIC CTUTOR PISTON 3/16" FLEXILE CONNECTOR O-RING SPRING CHECK VLVE SFETY URST DISC SSY PULL LEVER PORT CYLINDER VLVE SET SSEMLY SOLENOID PILOT VLVE 3/16" FLEXILE CONNECTOR SOLENOID PILOT VLVE CTUTED SIGM SERIES SYSTEM EQUIPMENT DESCRIPTION The Sigma System permits higher discharge rates and is particularly adaptable to areas requiring larger quantities of FM-200. description of the various equipment components unique to the Sigma System follows. PORT SFETY URST DISC SSY Cylinder Valve 2004 Chemetron Fire Systems. ll rights reserved (2/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems.

3" NPT DPTER NIPPLE S/N 70400133 3" GROOVED COUPLING S/N 70390540 3" - 90 GROOVED ELOW S/N 70390542 SOLENOID PILOT VLVE SSEMLY W/VENTED ELOW S/N 20610276 PIPE Y INSTLLER (NOT SHOWN) MLE CONNECTOR (S/N 50440028) 3/16" X 28" LG FLEXILE CONNECTOR (S/N 10260303) CYLINDER 3/16" X 28" LG FLEXILE CONNECTOR S/N 10260303 CYLINDER VLVE ND O-RING MNUL PNEUMTIC CTUTOR S/N 10610729 SIPHON (DIP) TUE OPTIONL LIQUID LEVEL LOCTOR (INDICTOR) Dip Tube: threaded dip tube extends from the cyl- C inder valve down to within approximately 1 in. (25 mm) of the bottom of the cylinder. The steel tube has a 3-1/2" O.D. and 1/8" (3 mm) wall thickness. The threads are 3-1/2 12UN-2. D Cylinder Valve: pressure differential type cylinder valve having a cast brass body is attached to the cylinder neck and serves to control the flow of FM- 200 from the cylinder. The valve is secured to the cylinder by means of 4.5-12UN-2 screw threads and is sealed by a cylinder O-ring. synthetic rubber seat is attached to a steel seat retainer, which is screwed into the bottom of the valve. The seat retainer also supports the dip tube. The cylinder valve has four connections, as follows: 1 Manual-Pneumatic ctuator Connection: This is a threaded connection housing a check valve and serves as the attachment point for the manualpneumatic actuator. CYLINDER NMEPLTE S/N 70360662 2 Pressure Gauge/Solenoid Pilot Valve ssembly Connection: This is a threaded connection housing a check valve and serves for the attachment of: Sigma Series FM-200 Cylinder ssembly with Completer Kit Solenoid pilot valve assembly (with pressure gauge) for pilot cylinders. Pressure gauge assembly for all other system cylinders. Cylinder Minimum Fill Capacity Maximum lbs kg lb kg Pilot Connection: 1/4" (6 mm) NPT tap in the cylinder valve cap provides a means of applying pilot pressure above the operating piston. 600 lb. 10481454 304 137.9 607 275.3 4 Discharge Connection: This connection (3 in. nomi- 750 lb. 10481455 455 206.4 910 412.8 nal pipe size) (76 mm) is in the form of an outlet fitting 1000 lb. 10481456 620 281.2 1000 453.6 that threads into the valve body and is sealed with an O-ring. The exposed end is grooved for attachment of grooved fittings (Victualic, etc.). The Cylinder: The welded seam steel cylinders are manu- outlet fitting can be removed for replacement if factured to the requirements of the Department of necessary. 3 Transportation (DOT) for compressed gas and have internal neck threads for cylinder valve connection. Safety Disc: frangible safety disc is located on the cylinder collar or valve assembly and serves to protect the cylinder against excessive internal pressure. The disc is designed to burst in a range of 850 psi to 1000 psi (5860 kpa to 6895 Kpa). COMPLETER KIT Either a primary or slave completer kit is required to complete the installation of each FM-200 cylinder. The components included in the primary and slave completer kits are detailed in the following chart. 2004 Chemetron Fire Systems. ll rights reserved (2/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems.

Completer Kits Primary 20480754 Quantity Slave 20480756 Quantity Solenoid valve w/vented elbow 1 0 Solenoid valve w/vented elbow & Supervisory Pressure Switch 1* 0 Manual-pneumatic actuator 1 0 Pneumatic booster assembly 0 1 3/16" flex hose 28" long 2 3 3" 90 Elbow, grooved 1 1 3" Coupling, grooved 1 1 3" dapter nipple 1 1 Male connector, 1/4 x 1/8 MNPT 1 1 Male connector, 1/4 x 1/4 MNPT 0 3 Pressure gauge 0 1 Pressure gauge w/supervisory Pressure Switch 0 1* Warning sign 1 0 Emergency operation nameplate 1 0 * Items are part of the Primary (S/N 20480755) and Slave (S/N 20480757) Completer Kits with Supervisory Pressure Switch If cylinders are used in a Main/Reserve system, order decals: Main Decal - S/N 50360753 Reserve Decal - S/N 50360752 and Main to Reserve Transfer Switch, S/N 20100145 Top View Front View Solenoid Pilot Valve ssembly - S/N 20610276 Manual-Pneumatic ctuator - S/N 10610729 This device is required for the manual actuation of a cylinder and is attached to a check valve connection port. This is a dual purpose device, having an actuating piston connected to a pin to upset the fill check valve when pilot pressure is applied to the piston. With the check valve open, cylinder pressure is applied through the pilot connection to the piston of the pneumatic actuator, thereby opening the cylinder to discharge its contents. Solenoid Pilot Valve ssembly The system utilizes a solenoid pilot valve assembly to provide pilot pressure for actuation. The solenoid must be electrically supervised by a recognized fire suppression system control panel. Front View Side View The solenoid pilot valve assembly includes a pressure gauge and adapter with swivel nut, elbow, and O-ring seal that is attached to the pressure gauge connection of the cylinder valve. 20610276 Solenoid pilot valve assembly 120V-60Hz/24VDC 20610278 Explosionproof Solenoid pilot valve assembly 24 VDC 20610277 Solenoid pilot valve assembly with supervisory pressure switch 120V-60Hz/24VDC Pneumatic ooster ssembly - S/N 10611067 This pneumatic actuator is used as a pneumatic booster for all cylinders connected to the manifold downstream of the pilot cylinder. Like the manual-pneumatic actuator, the device is attached to the check valve connection port and the internal operation is identical. ctuation of the booster is initiated by manifold pressure created by the opening of the pilot cylinder. PORT (OUTLET) 5/8" TYP U L 2-3/4" PORT (INLET) 3.75" 2004 Chemetron Fire Systems. ll rights reserved (2/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems.

Discharge Connection Fittings - S/N 20710368 3 in. (76 mm) grooved elbow, nipple, and companion coupling and gasket are used to extend the discharge outlet fitting of the cylinder valve to the piping system. These fittings ease assembly and accommodate some minor differences in alignment. 1-5/8" (41.3 mm) 3" (76.2 mm) leeder Pressure Gauge vented elbow on the outlet side of the solenoid is used to prevent accumulation of pressure due to accidental leakage through the solenoid pilot valve assembly, which, if unvented, could cause a false discharge of the system. OPTIONL EQUIPMENT Flexible Connector - S/N 10260303 Lengths of 3/16 in. (5 mm) flexible connectors are used to interconnect the cylinder valve devices. These hoses have a stainless steel wire braid cover and a Teflon liner, and are fitted at each end with a 1/4 in. swivel flare nut. Pressure Switch pressure switch is used in the system to implement the shut down of power and various items of equipment, such as fans; and for annunciation and alarm purposes. Pressure Gauge ssembly In systems requiring more than one cylinder, a pressure gauge assembly is required for each cylinder other than the pilot cylinder as a means of visual surveillance of the pressure condition within the cylinder. 20240041 Pressure Gauge ssembly 20610262 Pressure Gauge ssembly w/supervisory pressure switch S/N 10170089 10170089 2 Pole Pressure Switch indoor use only 70170229 Explosionproof 3 Pole Pressure Switch 10170065 4 Pole Pressure Switch weatherproof 2004 Chemetron Fire Systems. ll rights reserved (2/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems.

Check Valve - S/N 70610549 check valve is used between the cylinder valve discharge outlet flexible connection and the discharge manifold. The check valve prevents back flow from the manifold in the event that the system is discharged when one or more cylinders are disconnected, such as for weighing or general servicing. check valve is not required on single cylinder systems. CYLINDER RCK Single/Multiple Cylinders, Vertically Mounted 600 lb - S/N 20710264 750 lb - S/N 20710360 1000 lb - S/N 20710361 8½" The cylinder rack, consisting of a rail, a strap, and miscellaneous hardware for interconnection, is shipped unassembled. The rail is provided with 1-1/8 in. (2.85 cm) slots on 2 in. (5.0 cm) centers for mounting bolts. Nominal Cylinder Size Dimension in cm in cm 10481454 600 lb. 53-9/16 136.0 20-1/2 52.1 10481455 750 lb. 65-1/8 165.4 38-1/2 97.8 10481456 1000 lb. 59-1/4 150.5 29-1/2 74.9 Empty Cylinder Weight Lb (Kg) Cylinder ssembly Dimensions Height Diameter (C) in cm in cm 10481454 346 (157) 62-1/16 156.4 22 56.0 10481455 471 (214) 73-5/8 185.7 24 61.0 10481456 766 (347) 67-3/4 170.8 30 76.2 NOZZLES RIL LENGTH 600 lb = 26" 750 lb = 30" 1000 lb = 36" NTI-RECOIL PLUG Nozzles (8 port) are used to control the flow of FM-200 to insure it is discharged within 10 seconds and properly distributed in the protected hazard. NOMINL PIPE SIZE ORIFICE TYP 8 PLCES 360 Radial Nozzle NOMINL PIPE SIZE C NOTE:During actual cylinder installation, rotate the cylinder so that the nameplate is in the front. This should locate the discharge outlet to the left and angled approximately 45 to the rear. ORIFICE TYP 8 PLCES 180 Sidewall Nozzle 2004 Chemetron Fire Systems. ll rights reserved (2/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems.

Nozzle Height Nominal Pipe Size Stainless rass in mm 360 Radial Nozzle 10371360 10371415 3/8 in (10 mm) 2.031 51.6 10371361 10371416 1/2 in (13 mm) 2.250 57.2 10371362 10371417 3/4 in (19 mm) 2.688 68.3 10371363 10371418 1 in (25 mm) 2.875 73.0 10371364 10371419 1-1/4 in (32 mm) 3.250 82.6 10371365 10371420 1-1/2 in (38 mm) 3.625 92.1 10371366 10371421 2 in (51 mm) 4.500 114.3 180 Sidewall Nozzle 10371407 10371423 3/8 in (10 mm) 2.031 51.6 10371408 10371424 1/2 in (13 mm) 2.250 57.2 10371409 10371425 3/4 in (19 mm) 2.688 68.3 10371410 10371426 1 in (25 mm) 2.875 73.0 10371411 10371427 1-1/4 in (32 mm) 3.250 82.6 10371412 10371428 1-1/2 in (38 mm) 3.625 92.1 10371413 10371429 2 in (51 mm) 4.500 114.3 PHYSICL/CHEMICL PROPERTIES FM-200 (CF3CHFCF3 - heptafluoropropane) is a compound that consists of carbon, fluorine and hydrogen. It is colorless, odorless, electrically non-conductive, and suppresses fire by interrupting the combustion process and affecting the available oxygen content in the area of the discharge. FM-200 is clean, efficient, environmentally acceptable, and leaves no residue, thus minimizing any downtime after a fire. If exposed to temperatures greater than 1300 F, toxic products of decomposition (hydrogen fluoride) are formed. The system is designed to discharge in 10 seconds or less to minimize the amount of toxic byproduct formed during extinguishment of flames. Most materials contained in areas protected by FM-200, such as aluminum, brass, rubber, plastics, steel, and electronic components, are unaffected when exposed to FM-200. FM-200 is stored as a liquid in steel containers and superpressurized with nitrogen to 360 psig (2482 kpa) to increase its discharge flow characteristics. When discharged, FM-200 will vaporize at the discharge nozzles and effectively mix with the air throughout the protected area. SFETY CONSIDERTIONS In accordance with NFP Standard 2001 and the EP Significant New lternative Program (SNP), personnel exposure to FM-200 total flooding system concentrations shall be limited to the following: The discharge of FM-200 into a hazard may cause a reduction in visibility for a brief period. ny direct contact with the agent can cause frostbite. cylinder containing FM-200 should be carefully handled. ll anti-recoil devices must be in place at all times when the cylinder is not restrained. The FM-200 Material Safety Data Sheet (MSDS) should be read and understood prior to working with the agent. Concentration Level 9% or below (current NOEL) bove 9%, up to 10.5% Greater than 10.5% (current LOEL) Exposure Restriction No restriction Limit to 1 minute void any exposure The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. ll specific applications cannot be covered, nor can all requirements be anticipated. ll specifications are subject to change without notice. World of Protection 4801 Southwick Drive Third Floor Matteson, IL 60443 708/748-1503 FX 708/748-2847 email: info@chemetron.com 2004 Chemetron Fire Systems. ll rights reserved (2/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems.