SATRON VT Pressure Transmitter

Similar documents
SATRON VDt Differential Pressure Transmitter

SATRON VVFe Pressure Transmitter

SATRON VTe pressure transmitter

Page SATRON VT Pressure transmitter 7 SATRON VB Pressure transmitter 15

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Pressure transmitter for industrial applications Type MBS 4510

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Smart Pressure Transmitter

Differential pressure transmitter PASCAL Ci4 Delta P

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Differential pressure transmitter PASCAL Ci4 Delta P

JUMO dtrans p20 DELTA

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube variable area flowmeter for gases, liquids and steam

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Smart Pressure Transmitter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Smart Pressure Transmitter

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Differential pressure transmitter PASCAL Ci4 Delta P

Turbine flowmeters Series TM

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

SITRANS P measuring instruments for pressure

Ar-Mite TM Low Flow Armored Flowmeter

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

2600T Series Pressure Transmitter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Pressure transmitter JUMO dtrans p02

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

Installation and Setting-Up Instructions Spare Parts List

Pressure transmitter PASCAL CV4

SITRANS P measuring instruments for pressure

Relative and absolute pressure transmitter type 528

2010TC for Differential Pressure, Pressure and Temperature (Mass Flow)

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Special Purpose Transmitters

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

Pressure transmitters for industrial applications Type MBS 4510

ORIMAS Mass Flowmeter

Flow switches Series AD/VH

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitter for marine applications MBS 33M

Design and application

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

K - Flow Meter with Float

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

JUMO MIDAS S05 Pressure transmitter Type

Smart Pressure Transmitter

SATRON VDt differential pressure transmitter. Installation and Setting-Up Instructions Spare Parts List

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Pressure transmitter for industrial applications Type MBS 4500

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Installation and Setting-Up Instructions

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Plastic tube variable area flowmeter for liquids and gases

Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute. Series 2600T Pressure Transmitters. Engineered solutions for all applications

STEEMCO Flowmeter for Steam

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

BM 26 BASIC/ADVANCED Technical Datasheet

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Relative pressure transmitter type 522 for shipbuilding

BM 26 BASIC/ADVANCED Technical Datasheet

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

STEEMCO-MAS Flowmeter for Steam

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Flap-Type Flow Meter Prall

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

압력트랜스미터 Model ADP9000 Series

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Differential Pressure Sensors

p Additional dimensions see section dimensions.

Differential Pressure Sensors

Pressure transducer DMU 01K Compact version

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Transcription:

SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring applications SATRON VT-transmitters are used for measuring the pressure of clean gases, steam and noncrystallizing liquids.the transmitter's sensor is piezoresistive. The rangeability is 100:1 for types VT6 - VT8. M2, revision 2 TECHNICAL SPECIFICATIONS Measuring range and span See Selection Chart. Zero and Span adjustment Zero elevation: Calibrated span is freely selectable on the specifi ed range depending from the desired option. This can be made by using extern control shafts, keyboard (display option), HART 275/375 communicator. Damping Time constant is continuously adjustable 0.01 to 60 s. Temperature limits Ambient: -30 to +80 C Process: -30 to +120 C, DIN 16288-20 to +200 C, DIN 3852-X Shipping and storage: -40 to +80 C. Operating temperature of display: 0 to +50ºC (does not affect operation of the transmitter) Pressure limits Min. and max. process pressure: See the appended tables. Volumetric displacement < 0.5 mm 3 /max. span ( ) ±[0.025+0.01 x max.span calibrated span ]% of calibrated span (incl. nonlinearity, hysteresis and repeatability) Long-term stability ±0.1 %/max. span/12 months Temperature effect on compensated temperature ranges -20...+80 C Zero and span shift: ±0.15 % of max. span 0 to +200 C, (process connection, code 3, DIN3852-X-G½A, Flush Mounted) ±1 % of max. span, VT6 - VT7 ±2 % of max. span, VT4 - VT5 Mounting position effect (VT3 - VT7) Zero error < 0.32 kpa, which can be calibrated out. VT8: mounting position has no effect Vibration effect (IEC 68-2-6: FC): ±0.1 % of measuring range/ 2g/10 to 2000 Hz 4g/10 to 100 Hz Other sensing element materials: AISI316, SIS 2343. Filling fluid: Silicone oil or inert oil (VT3 - VT7) Enclosure class IP66 Housing with PLUG connector, housing type codes H and T Housing: AISI316, Seals: Viton and NBR TEST jacks: MS358Sn/PVDF, protected with silicone rubber shield. PLUG connector: PA6-GF30 jacket, Silicone rubber seal, AISI316 retaining screw. Housing with junction box/terminal strip, housing type codes M and N Housing: AISI303/316, Seals: Nitrile and Viton ; Nameplates: Polyester Connection hose between sensing element and housing : Codes L and K : PTFE hose with AISI316 braiding. Load / Imax = 20.5mA Output 2-wire (2W), 4-20 ma, user selectable for linear, square root, inverted signal or the transfer function (16 points)specifi ed by the user Supply voltage and permissible load See the load capacity diagram; 4-20 ma output: 12-35 VDC. Humidity limits 0-100 % RH; freezing of condensed water not allowed in reference pressure channels. PERFORMANCE SPECIFICATIONS Tested in accordance with IEC 60770: Reference conditions, specifi ed span, no range elevation, horizontal mounting; AISI316L diaphragm, silicone oil fi ll. Accuracy ±0.1 % of calibrated span (span 1:1-7.5:1 /max.range). On the measuring ranges 7.5:1-100:1: Power supply effect < ±0.01 of calibrated span per volt Insulation test voltage 500 V rms 50 Hz CONSTRUCTION AND CALIBRATION Materials Diaphragm 1) : AISI316L (EN 1.4435), Duplex (EN 1.4462), Hast. C276 (EN 2.4819), Tantalum or Titanium Gr2 (EN 3.7035). 1) Parts in contact with process medium Pressure limits Maximum process pressure, MPa Transmitter type VT3 VT4 VT5 VT6 VT7 VT8 Max. overload pressure 0.2 0.3 1.5 7.5 40.0 100.0 Pressure class PN40 PN40 PN40 PN100 PN250 PN1000 Rmax = Supply voltage - 10V Imax Supply voltage for transmitter without intrinsic safety (not ATEX) Minimum process pressure (VT8: no min. pressure limitations) T proc. C 20 40 80 120 Minimum pressure for different fill fluids (kpa, abs.) DC200 100 cst 5 8 16 21 Supply voltage / V Imax = 20.5mA using HART -communication Imax = 23mA (when the alarm current 22.5mA is on) Inert oil 8 10 28 53 Imin = 3.7mA Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Calibration For customer-specifi ed range with 1 s. damping. (If range is not specifi ed, transmitter is calibrated for maximum range.) Electrical connections Housing with PLUG connector, H and T: PLUG connector, connector type DIN 43650 model AF; Pg9 gland for cable; wire cross-section 0.5 to 1.5 mm 2. Housing with junction box/terminal strip, M and N: M20x1.5, 1/2-NPT inlet; screw terminals for 0.5 to 2.5 mm 2 wires Special Conditions for Safe Use (X) : The enclosure with plastic window and the plastic DIN43650 connector must not be installed in potentially explosive atmosphere requiring category 1 apparatus. The non-conducting surface of the sensor element may be charged by the fl ow of non-conducting media, so there may be electrostatic hazard with IIC-gases. These units should be marked 2 GD. The equipment shall be installed and connected according to the manufacturers instructions. Weight Transmitter - with housing types H and T : 0,7 kg - with housing type M and N : 1.2 kg Load / Product Certifications European Directive Information Electro Magnetic Compatibility (EMC directive 2004/108/EC) All pressure transmitters Atex Directive (94/9/EC) Satron Instruments Inc. complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) All Pressure Transmitters : - Sound Engineering Practice Transmitters with nominal pressure higher than 200 bar fulfi l the requirements of the Conformity Assessment procedure Module A of the directive. Rmax = Supply voltage - 10V Imax Supply voltage for transmitter with certified intrinsic safety (ATEX) Supply voltage / V Imax = 20.5mA using HART -communication Imax = 23mA (when the alarm current 22.5mA is Hazardous Locations Certifications European Certifications ATEX Intrinsic Safety Certifi cation No. : DNV-2007-OSL-ATEX- 1346X II 1 GD T135 C EEx ia II C T4-20 C Tamb 50 C II 2 GD T135 C EEx ia II C T4-20 C Tamb 50 C Input Parameters : Ui = 28 V Ii = 93 ma Pi = 0.651 W Ci = 5 nf Li = 0.2 mh Housing with PLUG connector, codes H and T

Dimensions ( in mm) 165 VT3...VT7, ATEX +15 145 VT8, ATEX +15 Ø48 G½ A DIN 16288 Pg 9 std. housing codes H and T Hex 36 VT3... VT7 Hex 27 VT8 165 VT3...VT7, ATEX +15 145 VT8, ATEX +15 75 Ø48 M20 x 1,5 std. housing code M 195 VT3...VT7, ATEX +15 175 VT8, ATEX +15 70 M20 x 1,5 std. housing code N

Dimensions ( in mm) 195 VT3...VT7, ATEX +15 175 VT8, ATEX +15 G½ A DIN 16288 91 Hex 36 VT3... VT7 Hex 27 VT8 PG9 housing N with plug DIN 43650, code N_ / P Housing codes H, T and M 195 Housing code N 225 Atex transmitter code 1, +15 Hex 27 14 Ø26 DIN3852-E-G½ Ø27 G½ Ø30 2,5 18,5 VT4 - VT7 Threaded DIN3852-X-G½A Flush-Mounted Diaphragm Process coupling DIN 3852-X-G½ Housing with terminal strip, code M Housing with terminal strip and display, code N Housing with terminal strip and display with plug connector DIN 43650, code N _/ P

Dimensions (mm) Clearance for cover removal 100 Housing codes H, T and M 215 Housing code N 245 Atex transmitter code 1, +15 170 Option K 125 149 110 min. R75 60 Pg9 std. housing type H and T M20x1.5 std. housing types M and N Option L Remote electronics, connecting cable with protection hose, codes L and K min. 290 Use of selector switch : RUN = working position PZ = Process value zero D = Damping adjustment S = Span adjustment Z = Zero adjustment DN = Down UP = Up Housing with PLUG connector, code T Process temperature / C Keyboard : Esc = Press Esc move back towards the top of the main menu. = Use the UP arrow key to move up on the current menu level or to increase the selected parameter value. = Use the DOWN arrow key to move down on the current menu level or to decrease the selected parameter value. Enter = Press ENTER to move to a lower level in a menu or to accept a command or parameter value. Housing with display, code N Recommended application range (horizontal mounting) Ambient temperature / C Process temperature limits for the transmitter of high temperature, process connection, code 3 (DIN3852-X-G1/2A, Flush mounted)

Selection Chart Adjustability Span, min Span, max Measuring range VT3 1.4 kpa (14 mbar) 35 kpa (350 mbar) -35...+35 kpa (-350...350 mbar) VT4 4 kpa (40 mbar) 100 kpa (1000 mbar) -100...+100 kpa (-1000...1000 mbar) VT5 10 kpa (100 mbar) 500 kpa (5000 mbar) -100...+500 kpa (-1000...5000 mbar) VTA5 10 kpa (100 mbar) 500 kpa (5000 mbar) 0...+500 kpa (0...5000 mbar), abs. VT6 0.03 MPa (0.3 bar) 3 MPa (30bar) -0.1...+3 MPa (-1...+30 bar) VTA6 0.03 MPa (0.3 bar) 3 MPa (30 bar) 0...+3 MPa (0...+30 bar), abs. VT7 0.15 MPa (1.5 bar) 15 MPa (150 bar) 0...+15 MPa (0...+150 bar), abs. VT8 1 MPa (10 bar) 100 MPa (1000 bar) -0.1...+100 MPa (-1...+1000 bar) Output S 4-20mA DC/HART -protocol Process connection 1 G 1/2A DIN 16288 (male) 2 1/2-NPT (male) 3 DIN 3852-X-G½A (male), Flush Mounted, not VT3, VT8 Wetted material Body Diaphragm Code Material Code Material 2 AISI316L (EN 1.4404) 2 AISI316L (EN 1.4435) (no VT8) 3 Hast. C 276 (EN 2.4819) 3 Hast. C276 (EN 2.4819) (no VT3, VT8) 6 Titanium Gr2 (EN 3.7035) 5 Tantalum (no VT3, VT8) (*) 8 Duplex (EN 1.4462) 6 Titanium Gr2 (EN 3.7035) (no VT3, VT4) (*) 8 Duplex (EN 1.4462) (no VT3, VT8) Fill fluid (specify for types VT3 - VT7) S Silicone oil G Inert oil Housing type H Housing with PLUG-connector, DIN43650, no display, inlet PG9 T Housing with PLUG-connector and with manual adjust, DIN43650, no display, inlet PG9, (no ATEX) M Housing with junction box/terminal strip, no display, inlet M20x1,5 N Housing with junction box/terminal strip, with display, inlet M20x1,5 Explosion proof 0 No explosion proof classifi cation 1 Atex Intrinsic Safety, II 1 GD T135 C (**) Process coupling 0 No coupling 1 Threaded coupling G½, DIN 16288 2 Threaded coupling G½, DIN 3852-X-G½ (Flush-Mounted) Special size of electrical inlet N 1/2 NPT G Pg13.5 P Plug DIN 43650 Special features Remote electronics (specify only if housing connected with cable to sensing element) - connecting cable with protection hose L Hose protected with PTFE/AISI316 braiding, straight K Hose protected with PTFE/AISI316 braiding, angle of 90 Length of connection cable between sensing element and housing 2 2 m cable 3 3 m cable etc. (max. 10 meter) Mounting parts for remote electronics for Ø 51 mm tube 0 No mounting parts 1 Mounting parts Documentation Calibration certificate AE English Installation and operating instructions I E English I F Finnish Material certificates O No material certifi cate MC1 Raw material certifi cate without appendices, in accordance with SFS-EN 10204-2.1 (DIN 50049-2.1) standard MC2 Raw material certifi cate for wetted parts, in accordance with SFS-EN 10204-2.2 (DIN 50049-2.2) standard MC3 Raw material certifi cate for wetted parts, in accordance with SFS-EN 10204-3.1 B (DIN 50049-3.1 B) standard We reserve the right for technical modifi cations without prior notice. HART is a registered trademark of HART Communication Foundation. Viton is the registered trademark of DuPont Down Elastomers. Hastelloy is the registered trademark of Haynes International. Tefl on is the registered trademark of E.I. du Pont de Nemours & Co (*) = not for process connection code 3 (**) = Housing H and N : II 2 GD T135 C