Approximately 13 years experience in H.V and L.V projects, 9 years in Egypt and two years in Emirates and two year in SAUDI ARABIA

Similar documents
ELE-CDGPS-E-1980 Senior Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-MPT-E-2009 Senior Maintenance & Protection Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Holds a B. Sc. in Communication Engineering and has about 21 years experience in testing and protection of several substations.

ELE-PT-E-2003 Senior Electrical Protection & Commissioning Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-MOS-E-2006 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

78-EL-CS-E-1994 Senior Electrical Engineer. PERSONAL DATA Nationality : Egyptian

ELE-CMS-E-2007 Electrical Project Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-CMOS-E-1987 Electrical Construction & Maintenance Manager PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-PT-E-2005 Electrical Testing & Protection Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-CMOS-E-2004 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-OS-E-2002 Start-up Shift Operation Engineer & Permit Coordinator PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-CMOS-E-2001 Manager of Electrical Construction Dept. PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-CMS-E-2001 Electrical Manager PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

CURRICULUM VITAE. Having an experience and knowledge in Testing, Commissioning and Maintenance of power plant, substation and process plant.

ELE-GPT-E-1988 Protection & Control Consultant PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

B. Sc., Mechanical power science Engineering, May 1987, Monofia University. - Construction Safety Health 30 hours Administration Training by (OSHA).

: Nubaria Module III - Egypt (2x250MW GE gas turbines frame 9 FA)

ICX-CMOS-S-2004 Senior I&C Technician PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ASEC scope of work and services can be classified as

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

ELE-MPT-E-2007 Protection, Testing & Commissioning Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-COS-E-1986 Electrical Lead Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ICX-CMOS-E-2004 Senior I&C Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Switchgear and Distribution Systems for Engineers and Technicians

2006 IEEE PES General Meeting June 2006, Montreal, Canada Paper 06GM0613. Fault Current Limiters - Report on the Activities of Cigre WG A3.

Agility in energy Ahead of the challenge, ahead of the change

SUBSTATION DESIGN TRAINING

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Company Directive STANDARD TECHNIQUE: SD4O/1. Standard HV Connection Arrangements

CHAPTER 4 PROTECTION REQUIREMENTS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

APPENDIX C FACILITY ILLUSTRATION

SYSTEM EARTHING & PROTECTIVE EARTHING

ASSESSMENT LIST ALS 2-7

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Welcome to Corporate Presentation

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

MEC-CM-E-2001 Lead Mechanical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

COMPACT SUBSTATION GUIDE

Advanced Protective Relay Training

Dual Power. Protection. Protection

Powering the railways in the Middle East Efficient and reliable solutions for sustainable mobility

ADVANCED POWER GENERATION TRAINING

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

ICX-CMOS-E-2000 Lead I&C System Engineer(Comm./ GT Controller) PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

Modular integrated transportable substation (MITS)

Curriculum Vitae. Date of Birth: 23/03/1951 mailing address: Khilda P.O. Box 1877

JBBA Incident 1-NOV Saih Al Ahmar Incident 12-May Barka Incident 10-SEP-2011.

One-Fit,UFES, Reyrolle LM

ASSESSMENT LIST ALS 2-8

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Substation Maintenance Training

PRAGATI ENGINEERING COLLEGE

Substation Concepts for the Future

Power Products Division. Power Services Service underpins everything we do

Intelligence in Substation Automation

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Multi-purpose percentage restraint differential protection

Aswan high dam - Distributed control system AUTOMATION

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

EDS FUSE RATINGS AT DISTRIBUTION SUBSTATIONS

MCset kv Medium voltage equipment

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

TRANSMISSION SYSTEMS

RAPIER DSB Disconnectors

SF6 free high-voltage GIS installation in Zürich, CH.

Key features. DESIGNS: - Conservator type - Hermetically sealed

Air-insulated switchgear UniGear type ZS1

Guidelines on Bus Tendering & Specifications. Mohamed Mezghani Head of Middle-East and North Africa Office

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

Air-insulated medium-voltage secondary distribution switchgear

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010

TECHWARE is partner of CONSORZIO ITALIA 2000 (CI2000) Leader in the world for the HHV/HV overhead lines TCW and CI2000 a global

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

EE042: Practical Power System Protection for Engineers & Technicians

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

بتروتك للمقاوالت PETROTEC

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

This qualification has been reviewed. The last date to meet the requirements is 31 December 2020.

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

RESUME. 2. Honors Diploma in Web Centric Computing from NIIT Coimbatore, India.

POWER SYSTEM INCIDENT REPORT: TRIP OF NO 1 AND 2 NEW OSBORNE 66 KV BUSBARS ON 26 SEPTEMBER 2010

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

refurbishment and services

ASSESSMENT LIST ALS 2-9

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

Stefano Cervidi - ABB S.p.A. PPHV Santiago de Chile J.T. ABB Chile de Abril 2015 PASS - Plug and Switch System Subestaciones con tecnologìa

Protection with distributed generation, experience with the Mont-Soleil wind farm project

Burns & McDonnell ISU Senior Design Project 2010/2011

Instrumentation Catalog

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Electric Vehicles Coordinated vs Uncoordinated Charging Impacts on Distribution Systems Performance

Matteo Ibatici, Marketing and Sales Department, 04 th June ABB S.p.A. PPD U.O. Adda HV PASS Family & new products

MESG 12 / 17.5 / 24 / 36 KV

Transcription:

EL-PT0-E-0083-1994 Testing and Protection Engineer Approximately 13 years experience in H.V and L.V projects, 9 years in Egypt and two years in Emirates and two year in SAUDI ARABIA PERSONAL DATA: Nationality: Egyptian Date of Birth: 01/01/1970 Marital status: Single EDUCATION: B. Sc in Electrical Power and Machine Engineering, 1994, Menofia University, Egypt. COMPUTER SKILLS: Windows, Word. LANGUAGES: Arabic: Native Language English: Good TRAINING COURSES: Competent Certificat, Health Saftey & Enviroment in ADDC has approved me a testing of electrical equipments Course over the tester ISA automatic in Al Ain Hilton in course with the company products. High Voltage Line protection (P5) course at Network center in Egypt, over the period from Jan.27th to Feb. 7th 2001. Calibration of energy meters course at Energ efficiency improvement and greenhouse gas reduction project in Egypt over the period from Apr.29th to May 6th 2000. The substation protection (P4) course at Network center in Egypt, over the period from Sep. 5th to Oct. 15th 1998. Reading control circuit diagrams (CCS) course at Network center in Egypt, over the period from May.30th to jun.18th 1998. The protection fundamental (P2) course at Network center in Egypt, over the period from Mars.14th to Apr.2nd 1998. Instrument transformers and power measurement (P1) EGYPTROL www.egyptrol.com 1/5 EL-PT0-E-0083-1994

course at Network center in Egypt, over the period fromfeb.21st to Mar.12th 1998. On Load tap changer (OLTC) course at Network center in Egypt, over the period from Oct.18th to Oct.30th 1997 Fire prevention systems course at Network center in Egypt, over the period from Mar.15th to April 3rd 1997 CHRONOLOGICAL EXPERIENCE RECORD: Date: From September 2006 to date (November 2009) Employer HYUNDAI (MEEDCO) KHURSANIYAH 380/115kV project, and KHURAIS 380/115 kv project, supply TOSHIBA in 380kV and HYUNDAI in 115kV Job title: Pre-commissioning Test for over head line distance protection relays as (Siemens relay type 7SA522, ABB relays type REL 531). Pre-commissioning Test for over head line directional earth fault relays Pre-commissioning Test for OHL tele-protection schemes end to end test for distance protection and directional earth fault relay. Commissioning of OHL with load check and (distance relay & directional earth fault relay directional check). Pre-commissioning of OHL Relay & control panel scheme function check. Pre-commissioning test for (132KV & 33KV) Underground cables protection relays as (SOLKER) Pre-commissioning test for power transformer differential protection relays as( RADSB,RET,DIOBIAS) Pre-commissioning test for power transformer diff. Relay stability and sensitivity test. Pre-commissioning of power transformer R.E.F relay stability and sensitivity test. Pre-commissioning of power transformer relay and control panel scheme function check. Pre-commissioning of automatic voltage regulator relays as(mr,spau341c) Pre-commissioning of automatic voltage regulator control panel scheme function test. EGYPTROL www.egyptrol.com 2/5 EL-PT0-E-0083-1994

Pre-commissioning test for Busbar protection relays as(mfac34,radhd,reb500,7ss522) Pre-commissioning test for Bus bar protection & CBF schemes function test. Pre-commissioning test for Bus bar protection stability and sensitivity test. Pre-commissioning test for under frequency relays. Pre-commissioning test for under frequency relay scheme function test. Pre-commissioning test for different types of over current relays Commissioning of New substations 380/115/13.8 KV (S/S Abu Hadriyah),380/115/13.8KV (S/S Khurais BSP) and commissioning modified in Qurayah SW 230KV, Shedgum 380KV, Qurayah 380KV, Ghunan 380KV,Abqaiq230KV (Saudi Electricity Company-East Region Branch) Pre-commissioning test for 115KV GIS as follows: o Scheme Function check o Operation and interlock circuit check o All current transformer tests Pre-commissioning test for 13.8KV Switchgear test as follows: o 13.8KV Switchgear function check. o All CT tests o Protection relays tests o Pre-commissioning test of 13.8KV Switchgear automatic change over scheme. Date: From September 2004 to 2006 Employer: Ghantoot company in Emirates Project no. A1800 in Al Ain, this project is package units 33/11KV. The project contains two lots, lot 1 delivered package units and relocate the transformers and lot 2 delivered the package units and the transformers All relays used from VA TECH Reyrolle company, Over current, earth fult, brocken conductor is Argus1 and Delta111, Duobias for Diffrental, restricted earth fault and omega used in distance protection and PILOT WIRE PROTECTION SOLKOR R/RF for Cable feeders and EGYPTROL www.egyptrol.com 3/5 EL-PT0-E-0083-1994

Job title: share working in Al Batten s/s 132kv/11kv in ABU Dhabi as rental to ABB T&D for testing Bus Bar and other relay like REL531 and Synch-check Testing and Protection Engineer Date: From September 1998 to September 2004 Employer: Job title: Middle Delta Zone, in Tanta substation 220/66/11 KV Shared in supervising the project and handling over from foreign contractors Commissioning with the contractors, the protection scheme is design and delivered from Schneider company sharing with ABB company The protection relays is static and digital like SEL321, distance relay of Merlin Gerin, Micro mho for GEC Alstom and REL series of ABB as distance relays And the bus bar protection relays are MBCZ of GEC Alstom and INX5 of ABB, the differential relay DTN of ABB and K-series of GEC Alstom Using several kinds of testing equipments related to IEC standards like Svereker 760, ISA (Italian testing equipment), Manta, Freja automatic tester and all programma testing equipments And Familiar with designed scheme for extension of medium voltage and high voltage bus bars with compatible equipments, fire fighting systems, heating ventilation air condition (HVAC), extra height voltage cable and termination(g&w, Elatimold of USA) Date: From November 1996 to September 1998 Employer: Ministry of Electricity and Energy, Egyptian Electricity Authority Heliopolis substation 220/66/11 KV, and Cairo North substation 220/66/11 KV Gas insulation system, delivered by ABB Job title: Protection engineer for testing and commission the relays and problems occurred in the network Testing several kinds of relays static and digital types, the EGYPTROL www.egyptrol.com 4/5 EL-PT0-E-0083-1994

using relay is directional over current types as K- series of GEC Alstom and Spaj of ABB, the differential used is DTN, RADSS, and SPAD of ABB, the distance relay used is REL of ABB and Micro mho of gecalstom Dealing with programmed testing equipments Date: From 1994 to October 1996 Employer: A company in the field of several kinds of systems using high techniques like computerizing systems Job title: Maintenance and protection engineer EGYPTROL www.egyptrol.com 5/5 EL-PT0-E-0083-1994