Health Monitoring of Rotating Equipment from Torsional Vibration Features

Similar documents
TECHNOLOGY DEVELOPMENT FOR SHAFT CRACK DETECTION IN ROTATING EQUIPMENT

Weir Valves & Controls USA Inc. World Leader in Design, Manufacture and Service Support for BWR and PWR MSIV s

Condition Monitoring of Electrical Machines ABB MACHsense Solution

5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS

Outage dates (duration): March 2, 1993 to April 20, 1994 (1.1 years) Reactor age when outage began: 11.7 years

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD

The ADS-IDAC Dynamic PSA Platform with Dynamically Linked System Fault Trees

Artesis MCM Case Studies. March 2011

Advanced Rotordynamic Bearing Technology And Case Histories in the Rotating Machinery Industry

NEIL Turbine Generator Risk Assessment. Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013

Reactor Safety /22.903

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps

Balanced Stator Seal for Reactor Coolant Pump Retrofits

74 ow. 10 CFR 50.46(a)(3)(ii)

Visual Inspection of Reactor Vessel Head Penetration Nozzles

GAS TURBINE BLADE AND DISK CRACK DETECTION USING TORSIONAL VIBRATION MONITORING: A FEASIBILITY STUDY

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR

Within the 300 GW total, the Energy Department estimates that 54 GW will be required from offshore wind to feed the large coastal demand centers.

Robotics and Manipulators for Reactor Pressure Vessel Head Inspection

Future of the Power System? Presented by : Yazhou (Joel) Liu, Ph.D., PE Schneider Electric Engineering Services electric.

Experimental study of DHC. cladding and implications. dry storage conditions

Component Asset Management with Ultra-High Pressure Cavitation Peening

Hope Creek Variable Frequency Drive

Condition Monitoring in the Wind Industry, Relevant Technologies, and its Importance.

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

The First of Its Kind in Industry! SOKODES Was Developed for Use with Solar Panels to Quickly Detect Faults and Estimate Their Location

Fundamentals of Rotor-Bearing Dynamics And Case Histories in the Rotating Machinery Industry

Appendix G Examples and Recommended Methods

Machinery Vibration Limits and Dynamic Structural Response

Effect of Compressor Inlet Temperature on Cycle Performance for a Supercritical Carbon Dioxide Brayton Cycle

Vibration studies and on-site balancing of GT-1 assembly

Pump Division AFV. Vertical Axial Flow Pumps. Bulletin PS-40-3 (E)

FAULT ANALYSIS IN GEARBOX USING VIBRATION TECHNIQUE

ROTATING MACHINERY DYNAMICS

FLEXIBILITY & NUCLEAR ENERGY MANAGEMENT IN FRANCE

NUCLEAR POWER GENERATION. Est Safety-Related and Commercial Actuation Products

Nuclear L.L. C. 10 CFR 50.55a

The role of CVR in the fuel inspection at Temelín NPP

WELCOME AND INTRODUCTORY REMARKS

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

FLORENCE ELECTRICITY DEPARTMENT. MANUFACTURING SERVICE RATE--SCHEDULE TDMSA (October 2015) Availability

DEVELOPMENT OF NEW MANIPULATORS FOR PWR AND VVER VESSEL INSPECTION. Authors: Mats Wendel and Torbjörn Sjö, DEKRA Industrial, Sweden

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. LARGE MANUFACTURING SERVICE RATE SCHEDULES (November 2018)

Failure of a Test Rig Operating with Pressurized Gas Bearings: a Lesson on Humility

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

EPRI Plenary Session Circuit Breaker Users Group Briefing

April 23, U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC

Electric Transportation and Energy Storage

AP1000 European 7. Instrumentation and Controls Design Control Document

Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure

ONLINE NON-CONTACT TORSION SENSING METHOD USING FIBER BRAGG GRATING SENSORS AND OPTICAL COUPLING METHOD. Yoha Hwang and Jong Min Lee

Power-GEN Middle East

AERO AERODERIVATIVE AND INDUSTRIAL GAS TURBINES NON INTRUSIVE SENSOR SYSTEM

Sacramento Municipal Utility District s EV Innovators Pilot

ASME BPV XI NUCLEAR INSERVICE INSPECTION STANDARDS COMMITTEE HANDOUT

Eddy Current Displacement Transducer Specifications

L DIT RUNNING CHANGES

TEPCO NUCLEAR SAFETY REFORM PLAN PROGRESS REPORT 1 ST QUARTER FY 2014 EXECUTIVE SUMMARY

Vibration Signature Analysis as a Diagnostic Tool for Condition Assessment of Rotating Equipments Experience at TAPS

Monitoring Variable Speed Bearings Using Ultrasound

AGN 076 Alternator Bearings

Caution and Disclaimer The contents of these materials are for information purposes and are provided as is without representation or warranty of any

4 submersible pumps powered by renewable energy sources

James Graham, P.E. Standards Coordinator Transformers Committee

Steam Turbine Seal Rub

Torsional Analysis Challenges of a Centrifugal Pump Train. Niels Peter Pauli Lloyd s Register Consulting Niklas Sehlstedt Lloyd s Register Consulting

ALSTOM WORLD WIDE EXPERIENCE OF STEAM TURBINE RETROFITS ON NUCLEAR POWER PLANTS. May 2015

McNary Northshore Fishway Hydro Project. History & Lessons Learned

The two RENK LABECO test stands are intended to provide endurance and acceptance testing for both R&D and post-assembly quality assurance.

AP1000 Nuclear Power Plant Squib Valve Design Challenges & Regulatory Interface. September 2017

ESIA Study for 1,050MW Coal Fired Power Plant, Lamu County, Kenya Need for the Project. 3 Need for the project... 2

GE ABWR & ESBWR. Jeff Suggs ESBWR I&C April 17, Copyright 2006 by GE Energy / Nuclear

Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times

Supplemental Report on the NCTPC Collaborative Transmission Plan

Boston Scientific Energy Storage Project. Final Report (PUBLIC) November 2016

ENTSO-E Winter Outlook

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd.

Smart grids in European Union. Andrej GREBENC European Commission "Energy Awarness Seminar Villach

ACCIDENT TOLERANT FUEL AND RESULTING FUEL EFFICIENCY IMPROVEMENTS

Pump Division HDX. API 610 Double Suction, Radially Split Process Pump. Bulletin PS-20-4 (E/A4)

The IAEA does not normally maintain stocks of reports in this series.

Willem van der Westhuizen Pump Consultant Eskom Enterprises Engineering Johannesburg South-Africa. Master Degree in Mechanical Engineering

Status of HPLWR Development

Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS

I. 22. Price. Technical Report Documentation Page

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

Ageing Management, In Service Inspection and Exceptional Maintenance. D. Dallery J.J. Nicolay (Nuclear Operations Division, EDF - France)

Electricity Technology in a Carbon-Constrained Future

IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA TEL: IMT PART NUMBER

Substation inspection guidelines Mark B. Goff, P.E.

Dynamic Balancing. Need a high-speed balance? No problem.

Presented at SC-2, Meeting October 5-6, 2010,, Seattle, WA

MC High Pressure Stage Casing Pump

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. TIME-OF-USE GENERAL POWER RATE--SCHEDULE TGSA (November 2018)

Glendale Water & Power Smart Grid Project

REEML. Flicking the Switch: Retail Demand-Side Response under Alternative Electricity Pricing Contracts. IRLE May 21, Tim Capon Taylor Smart 13

DEVELOPMENT OF VIBRATION CONDITION MONITORING SYSTEM APPLYING OPTICAL SENSORS FOR GENERATOR WINDING INTEGRITY OF POWER UTILITIES

Spin Rig for NSMS Probe Development and Strain Gage Correlation

M High Performance Power Transmission Couplings

In-situ Testing Technique for On-Going Cable Aging Assessments at Oyster Creek

Transcription:

College of Engineering Health Monitoring of Rotating Equipment from Torsional Vibration Features Martin W. Trethewey Department of Mechanical and Nuclear Engineering Penn State University April 13, 2007

Project Participants Penn State University Applied Research Laboratory Mechanical & Nuclear Engineering Engineering Science & Mechanics Tennessee Valley Authority Electricité de France Southern Company Dominion Framatome ANP - Jeumont EPRI 4/14/2007 2

Electric Power Generation Mechanical Equipment Subject to: High loads Thermal gradients High operating hours Corrosion Radiation Results Fatigue cracks 4/14/2007 3

Fossil Boiler Feed Pump Blades Fatigue Cracks Fatigue Cracks 4/14/2007 4

Hydro Turbine Driveshaft 4/14/2007 5

Nuclear BWR Recirculation Pumps NRC Information Note 2005-08 April 2005 Many Byron Jackson (now Flowserve) RRP shafts have been inspected ALL have some thermal cracking at thermal barrier Axial cracks Generally benign Dangerous Circumferential Cracks Axial thermal cracks change direction under mechanical loading Fast growing Can cause catastrophic shaft failure General Electric recommends ALL pumps with 80,000 hours service be inspected and monitored for cracks 4/14/2007 6

TVA Nuclear Shaft Crack History Browns Ferry - Reactor Feed Pump October 1979 Browns Ferry - Recirculation Pump January 1984 Watts Barr - Main Feed Pump April 1997 June 1997 Sequoyah - Centrifugal Charging Pump July 1981 January 1994 April 1999 Sequoyah - Reactor Coolant Pump October 2000 April 2002 Spring 2005 4/14/2007 7

TVA Sequoyah RCP 2-1 June 2002 4/14/2007 8

Post Mortem 4/14/2007 9

TVA Sequoyah RCP 1-4 2000 4/14/2007 10

Torsional Monitoring As a crack propagates Stiffness decreases Decrease in torsional natural frequency Torsional domain less susceptible to Seal rubs Changes in film bearing stiffness Thermal growth Misalignment If a torsional natural frequency change is observed A change in the line shaft dynamics occurred 4/14/2007 11

Laboratory Feasibility Evaluation Fatigue Cycling Torsional Stiffness NDE Crack Inspection Torsional Vibration Signature Analysis 4/14/2007 12

Post Mortem Crack Inspection Y a/d = 65% a/d = 50% C L R a/d = 5% X 4/14/2007 13

Torsional Natural Frequency versus Fatigue Crack Depth Y a/d = 65% a/d = 50% a/d = 5% X % 4/14/2007 14

Objective 2 41% Scale Seeded Fault RCP Tests Motor Motor Stand Pump Bowl 4/14/2007 15

AREVA 41% Reduced Scale RCP Loop 4/14/2007 16

Reduced Scale 93A RCP 4/14/2007 17

Circumferential Cut Testing 2002 TVA Sequoyah RCP 2-1 5 sequential cuts 4 mm (10% of the diameter) 8 mm (20% of the diameter) 12 mm (30% of the diameter) 16 mm (40% of the diameter) 20 mm (50% of the diameter) 4/14/2007 18

Circumferential Cuts 1 st Torsional Frequency Frequency (Hz) 112 111 110 109 108 107 106 105 104 103 3-Probe Process Probe 1 Probe 2 Probe 3 102 0 5 10 15 20 25 Cut Depth (mm) 4/14/2007 19

PWR Reactor Coolant Pump Pump Description Flow Net Pump Head Nominal Operating Temperature Speed Nominal Motor Power Vertical shaft Single stage Suction diffuser type Limited leakage system 20,200 m3/h 80-90 m About 290 degree C 1,190 RPM 4,480 kw 6,000 HP 4/14/2007 20

93A RCP Torsional Hardware 4/14/2007 21

Mechanical Installation 4/14/2007 22

Torsional Vibration Feature Trending Started after November 2004 refueling outage Acquired on two pumps 20 minutes data snapshots Acquired twice a day At different times throughout the day 4/14/2007 23

Project Status Based on TVA Data Assessment Crack sensitive torsional features observable Provides critical design and installation experience Will guide changes to improve performance Acquired torsional data sufficient for FEM Refinement Trending Variation assessment 4/14/2007 24

Project Status Potential a technology capable of detecting and monitoring shaft crack growth Early detection of cracks Significantly superior to existing technology Readily adaptable to other pumps and rotating equipment 4/14/2007 25

Acknowledgements This work was supported by the Electric Power Research Institute (EPRI Contract EP-P9801/C4961). The content of the information does not necessarily reflect the position or policy of the EPRI, and no official endorsement should be inferred. 4/14/2007 26