Wastewater Solutions

Similar documents
Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

DSN. Switch-rated plug and receptacle with Type 4X protection

Switch rated plugs and receptacles with nema 4X protection

Switch rated plugs and receptacles

POWER GENERATION SWITCH RATED ELECTRICAL CONNECTORS FOR INDUSTRY. hyconelec.co.za MARECHAL TECHNOLOGY

NFPA 70E 68! & CSA Z462

Robust construction and high amperage capabilities

SWITCH-RATED = + Plugs & Receptacles THE MAIN DIFFERENCES. DECONTACTOR TM Technology. Switch and Hp Ratings. Short Circuit Ratings

Robust construction and high amperage capabilities

Plugs, Receptacles & Connectors

DS Switch-Rated. plug and receptacle. Main Advantages. DS100 p. 48 DS200 p. 50 Spare parts p. 52 Dimensions p. 54

WATER & WASTE WATER INDUSTRIES

Switch rated connectors for. Ports, Shipyards & Vessels

PORTS, MARINAS, SHIPYARDS & VESSELS

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

MAIN OPTIONS DESCRIPTION OF THE KEY OPTIONS OF OUR PRODUCTS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 132 PF/PFQ A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p.

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 128 PF/PFQ A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p.

Technical Manual TYPE 4X

SWITCH SHOULD BE ON THE UPPER SIDE!

Mechanical features. Spring-loaded elastic terminals: resist vibrations

THE ADVANTAGES OF BUTT CONTACTS

SWITCH SHOULD BE ON THE UPPER SIDE!

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Now - Up To 400A Mains!

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Receptacles & Wall Boxes with Integral Circuit Protection

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

BAC Custom Engineered Controls

Design Standard. Purpose: Design Standard:

HEAVY-DUTY PLUGS & SOCKETS

Products for. Section

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Product guide. Enclosed NEMA starters. Answers for industry.

Specification made simple for selective coordination in a compact size

Product Guide. enclosed NEMA STARTERS

OTEC Transfer switch open transition

Quik-Spec Electrical Gear

General information about motor protection

Product Specification Sheet #3LD2.1

Application Description

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Quik-Spec. Section Contents

Selection Guide Motor Control Device Solutions

INDUSTRIAL DECONTACTOR & CONNECTOR SYSTEMS

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Transfer switch OTEC and OTECSE open transition

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

DECONTACTOR SWITCH WITH SOCKET-OUTLET

Bussmann series Quik-Spec Coordination Panelboard

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

Receptacles & Wall Boxes with Integral Circuit Protection

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

DN9C. Up to 9 contacts 30 A / 415 V max. IP54/IP55 Metal page 74. Up to 7 contacts 25 A / 500 V max. IP66/IP67 GRP or metal page 72

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

A Safety-First Priority

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

IEC 309 Plugs, Connectors, Receptacles, and Inlets

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

MULTICONTACT. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

Product Guide. NEMA pump controls.

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

SOCKET-OUTLETS WITH PROTECTION

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

Solar Combiner Solutions

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Safety Alert: Square D Safety Switches

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Self-ejecting systems applications

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Switches & Motor Controls

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

PDI PowerWave 2 Bus System

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

INDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES

EPIC. Pin & Sleeve Connectors PIN & SLEEVE CONNECTORS

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arrow Hart. environment devices. Watertight, severe duty and corrosion resistant devices for harsh industrial environments

Compact Circuit Protector (CCP) Application Note

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Transcription:

Wastewater Solutions Featuring Meltric s Switch-Rated Plugs, Receptacles and Electrical Connectors meltric.com A company of MARECHAL ELECTRIC GROUP

Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors are a combination plug and receptacle and disconnect switch in the same device. In addition to providing a safe and convenient electrical connection, they also provide the code required line of sight disconnect. They allow users to safely and easily make and break electrical connections even under full load. Using Meltric Decontactors to connect motors instead of hard-wiring can help reduce motor change-out downtime by 50% or more. Connection to an Anaerobic Basin Mixer Remote Lift Station Primary Air Compressor Simplify Maintenance Decontactors allow mixers and other equipment to be safely connected with plug and play simplicity. Mechanics can easily replace or service equipment without needing an electrician on site and without the need for electrical PPE, as required by NFPA 70E and CSA Z462. Equipment change-out times are significantly reduced, worker exposure to harsh environments is minimized, and re-wiring errors are eliminated (no more motors running backwards). Simplify Code Compliance Using Decontactors to connect pumps, grinders (shown) or other equipment, automatically provides the code required line of sight disconnect. The installation of Decontactors is a simple and cost effective means of achieving code compliance on new or existing installations. Decontactors function as a local disconnect and provide positive visual verification that power is off. The need and expense of a separate disconnect switch is eliminated. 2

Ideally Suited for the Wastewater Industry Decontactors are built with materials that withstand the harsh environment of wastewater treatment plants. For example, Meltric s silver-nickel contacts, stainless steel hardware, and chemical resistant housings help withstand corrosion caused by the hydrogen sulfide gases often found in wastewater environments. Other features, such as optional auxiliary pilot contacts, help make the operation of a wastewater plant safer and more efficient by allowing electrical interlocking with a motor starter and by simplifying the monitoring of key parameters that may indicate thermal alarms or seal failures. Connection to a Sludge Mixer in a Holding Tank Connections to Submersible Pumps for Effluent Water Provide Durable Connections Decontactors are ideal for connecting submersible pumps in both indoor and outdoor applications. Their spring-loaded, silver-nickel butt-style contacts provide consistently superior electrical performance over thousands of operations and are resistant to wear, corrosion, oxidation, and other factors that contribute.to the premature failure of pin & sleeve devices. They also feature a patented, spring assisted, screw terminal design that helps prevent connections from loosening over time due to conductor yield and vibration. Ensure Safety for Maintenance Personnel In addition to the safety benefit inherent in the contact design, all Decontactors have dead front construction, enclosed arc chambers and short circuit make and withstand ratings of at least 65kA. The dead front prevents user access to live parts and the short circuit rating ensures safety during insertion, even under overload or locked rotor conditions. Decontactors eliminate the safety hazards associated with pin & sleeve devices. 3

Benefit from Meltric Connectors Meltric Switch Rated Plugs, Receptacles and Connectors are ideal for connecting power to Pumps Mixers Aerators Portable Motor Grinders Compressors Generators Control Centers 4

STOP STOP Throughout Your Plant Application Spotlight: Submersible Mixers Submersible mixers and pumps are used throughout a typical wastewater treatment plant, as well as, at remote lift stations. When used to connect power to submersible mixers or pumps, Meltric Decontactors offer Safety Workers can safely make and break electrical connections under full load. The dead front safety shutter prevents access to live parts. Easy Equipment Change-outs A technician can break the power, service or replace the mixer, and reconnect power. There is no need for an electrician on site. Low Costs Decontactors are UL, CSA, and IEC switch rated. You effectively get a disconnect switch for free. Design and Installation Simplicity There is no need to locate and install auxiliary disconnect switches or mechanical interlocks. Long Life Robust materials and construction resist harsh environments. Butt-style contacts perform for thousands of operations. Extended Functionality Optional auxiliary pilot contacts allow facilities to easily interlock with motor starters and monitor key parameters, such as, thermal alarm or seal failure. Simple and Safe Operation Submersible mixer connections at a BNR process basin Meltric DECONTACTOR Typical submersible mixer application 1 2 3 4 When the plug and receptacle are latched together, the circuit is connected. Pressing the pawl causes the DECONTACTOR to break the circuit. The plug is ejected to its rest position; its contacts are now dead. Rotating the dead plug 30 counterclockwise closes the safety shutter and frees the plug to be withdrawn from the receptacle. The plug and the receptacle are separated. The safety shutter prevents access to live parts. 5

Meltric DECONTACTOR TM Series Plugs and Receptacles DSN pictured Spring-Assisted Screw Terminals Patented design assures Tighten and Forget confidence. Spring-Loaded Butt Style Contacts Ensures consistent contact force over thousands of operations. Lid Provides additional protection from harsh environments. OFF Button Press to deenergize. Provides push button circuit disconnection. Durable Casings Offers great resistance to impact and harsh environmental conditions. Dead Front /Safety Shutter Assures safety by preventing user access to live parts. Allow easy NEC, NFPA 70E and CSA Z462 code compliance Functions as a line of sight disconnect switch Safely makes and breaks resistive or inductive loads Lockout-Tagout Provisions Allows plug to be easily locked out and tagged. Optional padlock pawl allows lockout/tagout of the receptacle. Silver-Nickel Contacts Silver-Nickel material provides superior conductivity, durability and corrosion resistance. DSN 20-150A DS 20-200A DB 30-100A Compact, lightweight design Type 4X, IP66 +IP67 Up to 6 auxiliary contacts Fiberglass reinforced Polyester casings 100kA short circuit rated + Rugged construction Type 3R (4X optional) Up to 6 auxiliary contacts Fiberglass reinforced Polyester or Metal casings 65kA short circuit rated + High horsepower capacity IP67 Up to 4 auxiliary contacts Zinc aluminum alloy casing 100kA short circuit rated + + Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp ratings, except for DB100 which was tested with 250A fuses. Non-horsepower rated DS100 and DS200 devices were tested with RK5 time delay fuses sized at 100% of the devices rated ampacity. Tested to a Higher Standard Meltric Decontactors are the world s only UL and CSA switch rated plugs and receptacles. Not only do they meet performance test requirements for UL 1682/CSA C22.2 No. 182.1 (to which competitive pin and sleeve devices are listed), but Decontactors also meet the performance test requirements in UL Subject 2682 Switch-Rated Plugs and Receptacles. Based on their evaluation against this standard, Decontactors are UL and CSA listed for use in motor circuit disconnect/switching applications and in branch circuit disconnect/switching applications. Tests passed by Meltric Decontactors and by traditional pin and sleeve type plugs and receptacles (per UL 1682 and CSA 22.2 No. 182.1) Temperature Rise (not to exceed 30 C over ambient) 50 operations @ 150% device rating and.7 -.8 power factor Endurance - number of operations @.75 -.8 power factor 20A 5,000 under load 0 off load 30 to 60A 1,000 under load 1,000 off load 100 to 200A 250 under load 250 off load Additional Tests passed exclusively by DECONTACTOR TM Series plugs and receptacles per UL Subject 2682. 50 operations @ 6x motor FLA and.4 -.5 power factor 6,000 operations @ FLA and.75 -.8 power factor Short circuit make and withstand @ 65kA, 600V and <.15 PF Additional Listings include: IEC/ EN 60309-1, 60947-3, AS 3123 6

Product Technology & Specifications Safety & Code Compliance: Meltric vs the Competition MOTOR HARD-WIRED TO A BLADED DISCONNECT SWITCH MOTOR CONNECTED WITH A MELTRIC MOTOR PLUG MOTOR CONNECTED WITH A COMPETITIVE PLUG & RECEPTACLE Disconnect may be difficult to install in line of sight from the motor MOTOR CHANGE-OUT PROCESS 18 Qualified Worker w/ppe OR OR u Cord connection allows easy line of sight location u Dead front eliminates access to live parts and need for cumbersome PPE u Ability to safely make & break under load eliminates the need for interlocks u 65k A short circuit make and withstand rating ensures safety during reenergization MOTOR CHANGE-OUT PROCESS u Expensive mechanical interlocks are required since these plugs & receptacles cannot safely make & break under load u The interlock must be mounted on a fixed surface this may make line of sight location more difficult MOTOR CHANGE-OUT PROCESS 1. Switch disconnect to OFF position 2. Apply lockout/tagout 3. Perform Shock/Arc Flash Hazard Analysis 4. Obtain permit for energized electrical work 5. Suit up with appropriate PPE 6. Remove the disconnect switch cover 7. Voltage test to verify deenergization 8. Disconnect motor from hard-wiring 9. Remove old/install new motor 10. Connect new motor to hard-wiring 11. Jog the motor to ensure proper rotation 1. Switch Decontactor receptacle to OFF position 2. Mechanic removes plug from receptacle 3. Apply lockout/tagout as required 4. Mechanic removes old/installs new motor 5. Mechanic inserts plug into receptacle Meltric Makes it Safe & Easy 1. Open interlock switch 2. Determine PPE requirements & obtain 3. Remove interlock cover 4. Voltmeter test to verify deenergization 5. Remove plug 6. Apply lockout/tagout as required 7. Remove old/install new motor 8. Insert plug into receptacle Product Selection Guide Maximum Number Model Casing Voltage Amperage of Contacts Environmental Maximum horsepower Material (Max) Rating Main / Auxiliary Rating Rating (480V*) DSN20 Poly 480V 20A 3P+N+E - Type 4X IP66+IP67 5 hp DSN30 Poly 600V 30A 3P+N+E 2 Type 4X IP66+IP67 10 hp DSN60 Poly 600V 60A 3P+N+E 4 Type 4X IP66+IP67 20 hp DSN150 Poly or Metal 600V 150A 3P+N+E 6 Type 4X IP66+IP67 75 hp DS20 Poly 600V 20A 3P+N+E 2 Type 3R 7 1/2 hp DS30 Poly 600V 30A 3P+N+E 4 Type 3R 15 hp DS60 Poly or Metal 600V 60A 3P+N+E 3 Type 3R 20 hp DS100C Poly or Metal 600V 100A 3P+N+E 3 Type 3R 25 hp DS100 Poly or Metal 600V 100A 3P+N+E 6 Type 3R 30 hp DS200 Zamak 480V 200A 3P+N+E 5 Type 3R - DB30 Zinc Aluminum 600V 30A 3P+N+E 2 IP67 20 hp DB60 Zinc Aluminum 600V 60A 3P+N+E 2 IP67 30 hp DB100 Zinc Aluminum 600V 100A 3P+N+E 4 IP67 60 hp * Consult the Meltric catalog for horsepower ratings at other voltages. 7

More Products & Services for the Wastewater Industry Other Meltric Products Commonly Used in Wastewater Facilities Multipin Plugs and Connectors DXN Hazardous Duty Connectors Multipin products are commonly used in power and control applications. They are available with up to 37 contacts and have a total amp capacity ranging from 4mA to 100A. DXN s are horsepower rated and CSA listed for Class 1 Division 2 and Class 2 Division 2 environments. Suitable for loads up to 60A, 10hp, DXN s provide a compact, waterproof solution for potentially hazardous locations. Common Options Used in Wastewater Facilities Auxiliary Pilot Contacts Lockable Plugs or Receptacles Pilot Contacts Pilot contacts are available for operating secondary control circuits or for electrical interlocking with motor starters. Theses contacts make last and break first when the plug is engaged or disengaged. Two to six auxiliary contacts are available on Decontactors. Padlockable Pawl Locking device not included Padlockable Plug Cap DSN Plug Padlockable pawls and plug caps are available for preventing unwanted connection or disconnection of plugs. Padlockable pawls also allow the lid to be locked closed. Padlockable plug caps provide up to Type 4X watertightness. Meltric Service Replacement Parts Same Day Shipping Five Year Warranty The need to replace parts is rare. However, should they be required, parts are readily available and reasonably priced. Purchasing the individual parts costs no more that buying an assembled product. Due to the modular design of our product and efficient customer service and factory operations, most of our orders are shipped by the next day. For a small fee, orders can be shipped the same day. The electrical contacts on Meltric products are warranted for five years from date of shipment. The complete product is warranted for one year from the date of shipment. Contact Meltric for a full warranty statement. 8 2015 Meltric Corporation. All rights reserved. WWSOLNS H meltric.com 4765 W. Oakwood Park Drive Franklin, WI 53132 800.433.7642 Fax 414.433.2701 A company of MARECHAL ELECTRIC GROUP