Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Similar documents
Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Installation and Start-Up Instructions

Installation and Start Up Instructions

INFINITY ZONING QUICK START GUIDE

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

598B TWO-SPEED AIR CONDITIONER WITH PURON REFRIGERANT. Sizes 024, 036, 048, and 060. Form No. PDS 598B.24.7

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

ZoneTouch V2 Zone Control System Installation Manual

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Design Guide INTRODUCTION

Ducted medium static pressure monosplit DC Inverter

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Installation Instructions

Installation Instructions

SE8300 Series Installation Guide 24 Vac Low Voltage

Product Data. S Up to 19 SEER / up to 13 EER S Microtube Technologyt refrigeration system Sound

2011 International Comfort Products, LLC

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

Description. functions including single duct pressure dependent or pressure independent systems.

Installation Instructions

SPECIFICATION SHEET. C5000 ( cfm)

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 187B (2-5 Ton) 180B (3 Ton Trophy) EVOLUTIONt 17 AIR CONDITIONER WITH PURONr REFRIGERANT

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Product Data. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR) EZ Flext (EXPXX) Sizes 16, 20, 24. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR)

ACCESSORY CATALOG. Broadest line of PTAC & ETAC Enhancement Products

SetPoint 501 and 501s Controllers Installation and Operation Manual

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

CH5000 Heat Recovery Ventilator

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Installation Instructions

Installation Instructions

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Designed for ease of integration with automation systems

Product Data. Infinity 18 38TDB (60 Hz) Two-Speed Air Conditioner with Puron Refrigerant. Sizes 024, 036, 037, 048, and 060 FEATURES/BENEFITS

Digital Room Thermostats with Touch Screen LCD

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

RC-DO. Room controllers with display and manual forced ventilation function

Installation Instructions

Installation Instructions

SMT-150 Installer Manual

SMT-AZC INSTALLATION / OPERATION MANUAL

ENERGY RECOVERY SYSTEM 60 HZ

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

Models: 12 and 18. Models: 24 to 60

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

Combined Ventilation Controller RVWS-T-224HA

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Installation Instructions

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

Product Data. Residential Zone Dampers FEATURES/BENEFITS

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Metasys Zoning Package Installation

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

MicroTech II Applied Rooftop Unit Controller

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Cooling Capacity CFM in. w.c. (125 Pa)

DESCRIPTION AND OPERATION

How to Select the RE Industrial Actuator Part Number

Ductless Split Systems

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

TECHNICAL SPECIFICATIONS

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Ductless Split Systems

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

MRXBOX-VSC Visual System User Control Installation and Maintenance

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

FSH1BF Series. Extra High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 16 SEER Residential System 2-5 Ton Capacity

Installation, Service, and Troubleshooting Instructions

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

Q7RE Series Single Packaged Heat Pump, Single Phase

Gree Genuine Accessories

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER

Transcription:

SYSTXBBUIZ01 -D Evolutiont Zone Control Product Data A10287 NOTE: Evolutiont Zone Control compatible with Evolution rated indoor equipment only. EVOLUTION t ZONE CONTROL Bryantr specializes in creating a customized home comfort system tailored to your needs with our broad selection of residential heating and cooling products. The Evolution Zone Control System is the ultimate control center for all of your system components. When you add an Evolution Zone Control to a compatible variable speed furnace, fan coil, or small packaged product, you will enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home. By adding an Evolution or Preferredt compatible outdoor unit, your benefits will increase even more. Benefits include better humidity and temperature control as well as a more energy efficient comfort system. INDUSTRY LEADING FEATURES/BENEFITS Bryant s revolutionary Evolution Zone Control is the smart control of the future. The Evolution Zone Control features a large backlit liquid crystal display, making it easier to read the temperature, even at night. Intuitive prompts let you program everything from humidity levels to fan speeds, giving you ultimate control over your home comfort. The Evolution Zoning system does not require a bypass damper, leaving air temperature (LAT) sensor, or a field supplied power transformer. Up to 8 zones of control Patented automatic duct assessment design compensates for duct work variability No bypass damper required or recommended No LAT or HPT sensors required or recommended No field -installed transformer required Fan airflow adjustment by zone 4 wire installation from each component in the system Intuitive on screen prompts for ease of installation and service Perfect Humidityt settings are the default, no longer requiring increased system setup Complete integration of the temperature, humidity, and ventilation in every season Perfect Heatt capability TrueSenset Dirty Filter Detection Indoor Air Quality pop -up reminders 7 day programmability with 2 or 4 periods per day Easy timed override schedule Simplified vacation schedules Day -at -a -glance programming for simplified ease of use Programmable fan by period Color-themed displays General maintenance reminder messaging Optional Remote Access Kit can be added for access to your system from the internet.

MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 S Y S T X B B U I Z 0 1 - D Product Type Evolution System Software Version - D Packaged Quantity Brand 01 Bryant Model Type UIZ - Zone User Interface 4ZC - Damper Control Module NIM - Network Interface Module SAM - System Access Module RRS - Remote Room Sensor LBP - Large Backplate GRP - Green ABCD Connector RCT - System Access module (CAT5) RWF - system Access Module (WiFi) 4.2-in (107 mm) 1.5-in (38 mm) 6.4-in (163 mm) Fig. 1 - Unit Dimensions A10289 2

3.4" 86.4 mm 1.0" 25.4 mm 3.3" 83.8 mm.75" 19.1 mm 4.0" 101.6 mm 2.5" 63.5 mm HOLD Fig. 2 - Smart Sensor Dimensions ZONING EQUIPMENT A07283 Fig. 3 - Remote Room Sensor Dimensions Evolution Zone Control SYSTXBBUIZ01--- D Evolution Network Interface Module (NIM) SYSTXBBNIM01* Evolution Damper Control Module (4 Zone) SYSTXBBZC01{ NOTE: Each piece of zoning equipment is sold separately allowing for customization of the zoning application. * Ventilator requires a Network Interface Module or Damper Control Module for operation. Required to control a non---communicating heat pump in Hybrid Heatt applications. Required to control a non---communicating 2---stage AC or HP (i.e. R---22 Series A) { One damper control module handles up to 4 zones. A second damper control module is needed for zones 5---8. A07284 OPTIONAL ACCESSORIES Evolution System Smart Sensor SYSTXBBSMS01--- C* Evolution Remote Room Sensor (RRS) SYSTXBBRRS01 Evolution Large Decorative Backplate SYSTXBBLBP01---C Green Indoor Unit Plug (ABCD Connector) --- 10 Pack Replacement SYSTXGRPLG10 Evolution System Access Module (Remote Access Kit, Skytel--- based) SYSTXBBSAM01 Evolution System Access Module (Remote Access Kit, Broadband---Wired, CAT5) SYSTXBBRCT01 Evolution System Access Module (Remote Access Kit, Broadband--- Wireless WiFi) SYSTXBBRWF01 Outdoor Sensor TSTATXXSEN01---B * A combination of Evolution Smart Sensors and Evolution Remote Room Sensors can be used in the zones. REPLACEMENT ACCESSORIES Damper Control Module 1---amp Fuse * Available from RCD ATO1* DAMPERS TYPE PART NUMBER 6--- in. (152.4 mm) DAMPRND06INC--- B 8--- in. (203.2 mm) DAMPRND08INC--- B Round Dampers 10--- in. (254 mm) DAMPRND10INC--- B 12--- in. (304.8 mm) DAMPRND12INC--- B 14--- in. (355.6 mm) DAMPRND14INC--- B 16--- in. (406.4 mm) DAMPRND16INC--- B 8---in. X 10---in. (203.2 X 254 mm) DAMPREC08X10---B 8---in. X 14---in. (203.2 X 355.6 mm) DAMPREC08X14---B 8---in. X 18---in. (203.2 X 457.2 mm) DAMPREC08X18---B Rectangular Dampers 8---in. X 24---in. (203.2 X 609.6 mm) DAMPREC08X24---B 10---in. X 10---in. (304.8 X 304.8 mm) DAMPREC10X10---B 10---in. X 14---in. (304.8 X 355.6 mm) DAMPREC10X14---B 10---in. X 18---in. (304.8 X 457.2 mm) DAMPREC10X18---B 10---in. X 24---in. (304.8 X 609.6 mm) DAMPREC10X24---B 3

DAMPERS (cont) TYPE PART NUMBER Side mount, 8--- in. X 8--- in. (203.2 X 203.2 mm) DAMPSLS08X08--- B Bottom mount, 8--- in. X 8--- in. (203.2 X 203.2 mm) DAMPSLB08X08--- B Side mount, 8---in. X 10---in. (203.2 X 254 mm) DAMPSLS08X10---B Bottom mount, 8--- in. X 10--- in. (203.2 X 254 mm) DAMPSLB08X10--- B Side mount, 8--- in. X 12--- in. (203.2 X 304.8 mm) DAMPSLS08X12--- B Bottom mount, 8--- in. X 12--- in. (203.2 X 304.8 mm) DAMPSLB08X12--- B Side mount, 8--- in. X 14--- in. (203.2 X 355.6 mm) DAMPSLS08X14--- B Bottom mount, 8--- in. X 14--- in. (203.2 X 355.6 mm) DAMPSLB08X14--- B Side mount, 8--- in. X 16--- in. (203.2 X 406.4 mm) DAMPSLS08X16--- B Bottom mount, 8--- in. X 16--- in. (203.2 X 406.4 mm) DAMPSLB08X16--- B Side mount, 8--- in. X 18--- in. (203.2 X 457.2 mm) DAMPSLS08x18--- B Bottom mount, 8--- in. X 18--- in. (203.2 X 457.2 mm) DAMPSLB08X18--- B Side mount, 8---in. X 20---in. (203.2 X 508 mm) DAMPSLS08X20---B Bottom mount, 8--- in. X 20--- in. (203.2 X 508 mm) DAMPSLB08X20--- B Side mount, 8--- in. X 22--- in. (203.2 X 558.9 mm) DAMPSLS08X22--- B Bottom mount, 8--- in. X 22--- in. (203.2 X 558.9 mm) DAMPSLB08X22--- B Side mount, 8--- in. X 24--- in. (203.2 X 609.6 mm) DAMPSLS08X24--- B Bottom mount, 8--- in. X 24--- in. (203.2 X 609.6 mm) DAMPSLB08X24--- B Side mount, 10---in. X 10---in. (254 X 254 mm) DAMPSLS10X10---B Bottom mount, 10--- in. X 10--- in. (254 X 254 mm) DAMPSLB10X10--- B Side mount, 10--- in. X 12--- in. (254 X 304.8 mm) DAMPSLS10X12--- B Bottom mount, 10--- in. X 12--- in. (254 X 304.8 mm) DAMPSLB10X12--- B Side mount, 10--- in. X 14--- in. (254 X 355.6 mm) DAMPSLS10X14--- B Bottom mount, 10--- in. X 14--- in. (254 X 355.6 mm) DAMPSLB10X14--- B Side mount, 10--- in. X 16--- in. (254 X 406.4 mm) DAMPSLS10X16--- B Bottom mount, 10--- in. X 16--- in. (254 X 406.4 mm) DAMPSLB10X16--- B Slip --- In Dampers Side mount, 10--- in. X 18--- in. (254 X 457.2 mm) DAMPSLS10X18--- B Bottom mount, 10--- in. X 18--- in. (254 X 457.2 mm) DAMPSLB10X18--- B Side mount, 10---in. X 20---in. (254 X 508 mm) DAMPSLS10X20---B Bottom mount, 10--- in. X 20--- in. (254 X 508 mm) DAMPSLB10X20--- B Side mount, 10--- in. X 22--- in. (254 X 558.9 mm) DAMPSLS10X22--- B Bottom mount, 10--- in. X 22--- in. (254 X 558.9 mm) DAMPSLB10X22--- B Side mount, 10--- in. X 24--- in. (254 X 609.6 mm) DAMPSLS10X24--- B Bottom mount, 10--- in. X 24--- in. (254 X 609.6 mm) DAMPSLB10X24--- B Side mount, 12--- in. X 12--- in. (304.8 X 304.8 mm) DAMPSLS12X12--- B Bottom mount, 12--- in. X 12--- in. (304.8 X 304.8 mm) DAMPSLB12X12--- B Side mount, 12--- in. X 14--- in. (304.8 X 355.6 mm) DAMPSLS12X14--- B Bottom mount, 12--- in. X 14--- in. (304.8 X 355.6 mm) DAMPSLB12X14--- B Side mount, 12--- in. X 16--- in. (304.8 X 406.4 mm) DAMPSLS12X16--- B Bottom mount, 12--- in. X 16--- in. (304.8 X 406.4 mm) DAMPSLB12X16--- B Side mount, 12--- in. X 18--- in. (304.8 X 457.2 mm) DAMPSLS12X18--- B Bottom mount, 12--- in. X 18--- in. (304.8 X 457.2 mm) DAMPSLB12X18--- B Side mount, 12--- in. X 20--- in. (304.8 X 508 mm) DAMPSLS12X20--- B Bottom mount, 12--- in. X 20--- in. (304.8 X 508 mm) DAMPSLB12X20--- B Side mount, 14--- in. X 14--- in. (355.6 X 355.6 mm) DAMPSLS14X14--- B Bottom mount, 14--- in. X 14--- in. (355.6 X 355.6 mm) DAMPSLB14X14--- B Side mount, 14--- in. X 16--- in. (355.6 X 406.4 mm) DAMPSLS14X16--- B Bottom mount, 14--- in. X 16--- in. (355.6 X 406.4 mm) DAMPSLB14X16--- B Side mount, 14--- in. X 20--- in. (355.6 X 508 mm) DAMPSLS14X20--- B Bottom mount, 14--- in. X 20--- in. (355.6 X 508 mm) DAMPSLB14X20--- B Side mount, 16--- in. X 16--- in. (406.4 X 406.4 mm) DAMPSLS16X16--- B Bottom mount, 16--- in. X 16--- in. (406.4 X 406.4 mm) DAMPSLB16X16--- B Bottom mount, 16--- in. X 20--- in. (406.4 X 508 mm) DAMPSLB16X20--- B DAMPER REPLACEMENT ACCESSORIES Actuators 45_ Actuator for round dampers DAMPACT45DEG--- R 90_ Actuator for rectangular dampers DAMPACT90DEG--- R Damper Actuator Cover DAMPACTXXCOV Module Damper Control Module 1---amp Fuse ATO1* * Available from RCD. 4

PRODUCT DATA INFORMATION Current Compatible Communicating Products Environmental Requirements: Air Conditioning units - 180B, 187B, 186B Heat Pumps - 286B, 289B, 285B Gas Furnace - 355AAV, 315AAV, 315JAV, 355CAV Fan Coils - FE Small Packaged Products - 577D, 707D, 607D, 677D Physical Characteristics of SYSTXBBUIZ01 Dimensions: See drawing Appearance: Plastic, silver and white Physical Characteristics of SYSTXBBSMS01 Dimensions: 4.0 -in. (101.6 mm) high x 3.4 -in. (86.4 mm) wide x 1.0 -in. (25.4 mm) deep Appearance: Plastic, white color, textured Physical Characteristics of SYSTXBBRRS01 Dimensions: 2.5 -in. (63.5 mm) high x 3.3 -in. (83.8 mm) wide x 0.75 -in. (19.1 mm) deep Appearance: Plastic, white color, textured Electrical Characteristics/Communication Input Volts/Amps 24VAC Each device in the Evolution System has a four-pin connector labeled ABCD. It is recommended that the following color code be used when wiring each device: A Green = Data A B Yellow = Data B C White = 24VAC (Com) D Red = 24VAC (Hot) Operating Temperature/Relative Humidity: User interface and all sensors: 32_F to 104_F (0_C to40_c), 95% rh non -condensing Storage Temperature/Relative Humidity: User interface: - 40_F to 134_F (-40_C to 56.7_C), 95% rh non -condensing Damper Control Module: -40_F to 185_F (-40_C to85_c), 41% rh non -condensing Program Specifications: Temperature setpoint range: 40_F to90_f (4.4_C to 32.2_C) Separate heat and cool setpoints Programming days: 7 day Programming periods: 2 -Day, Sleep 4 -Wake, Day, Eve, Sleep Auto changeover (may be disabled) Programmable fan (installer selectable) Humidity Sensor Offsets Perfect Heatt capable Auto Changeover Timer (installer adjustable) Smart Recovery (in heating and cooling) Hold function Copy functions: Copy period, day and zone Permanent memory Humidity display and control Temperature sensor offsets (indoor and outdoor) TrueSenset Dirty Filter Detection Color -themed displays Wiring Requirements: Power supply: Dedicated 24VAC, 40 va, 60 Hz, via indoor equipment ABCD Connector. Isolated transformer, field supplied. Wiring material: Standard thermostat wire 18 to 24 gauge. 5

E2011 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 04/11 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. PDSUIZ01---07 Replaces: PDSUIZ01 ---06 6