Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Similar documents
Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. VNC Series. Cylinder actuation by pilot air

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Exclusively for air pressure system and air-hydro circuit control

High Pressure Coolant Valve

VNA VNB SGC SGH VNC VNH VND VCC

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Series VP3145/3165/3185

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Process Valve/Series VN

Process Valve/Series VN

3 Port Solenoid Valve Direct Operated Poppet Type

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

0.35 W (Without light)

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Soft Start-up Valve. AV2000/3000/4000/5000 Series

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

Series SV1000/2000/3000/4000

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

3 Port Solenoid Valve

Series VP3145/3165/3185

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

1 1/4 (32A) to 2 (50A) added.

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Pilot Operated/Zero Pressure Differential Operation

Series VQ Port Solenoid Valve

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

3 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VQZ1000/2000/3000 Single Unit

3 Port Solenoid Valve

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

5 Port Solenoid Valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

3 Port Solenoid Valve

2 Port Solenoid Valve For Dust Collector

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

5 Port Solenoid Valve

Coolant Valve SGC2 :155 SGC3 :284 SGC4 :440. million cycles or more. Service life: 5 million cycles or more 5 Service life: million cycles or more

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

5 Port Solenoid Valve

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Series AV2000/3000/4000/5000

3 Port Air Operated Valve

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

5 Port Solenoid Valve

5 Port Air Operated Valve

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

5 Port Solenoid Valve

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

3 Port 3 Position Valve

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

2/3 Port Valve for Various Fluids Control

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Power Valve Precision Regulator

Transcription:

Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large valve capacity v factor 30 x 0-6 to 600 x 0-6 ( to 7) Cv factor 9 to 00 (8 to 9) VN VN VN 399

Coolant Valve: ir Operated/xternal Pilot Solenoid How to Order ir operated Seal material NR seals KM seals hread type Nil N Rc G NP NP racket (Valve : //3/) Nil Note) None With bracket (VN -6) Note) Only valve s,, 3 and. Shipped after assembled at our factory. racket part no. Valve : VN-6 (with thread) Valve s to : VN -6 to 0 5 (xcept valve 8, 9) xternal pilot solenoid 5 Nil: Non-locking push type Valve Symbol 3 5 6 7 8 9 00 Orifice diameter (mm) ø7 ø5 (ø) ø0 (ø) ø5 (ø6) ø3 (ø) ø0 (ø8) ø (ø33) ø65 (ø5) ø (ø56) Valve type Symbol N.C. N.O. N.C. 0.5 MPa MPa MPa Values in parentheses are N.C. at MPa. Port Symbol Port Rc 6 8 8 0 3 8 0 3 8 5 0 3 5 3 3 0 0 65 3 Rated voltage Nil ir operated 00 VC /60 Hz 00 VC /60 Hz 3 0 VC /60 Hz 0 VC /60 Hz 5 VC 6 VC 7 0 VC /60 Hz 9 Other lectrical entry/with light/surge voltage suppressor Nil ir operated G Grommet GS Grommet with surge voltage suppressor Grommet terminal Z Z Z S Z L : Slotted locking type (tool required) Nil: Non-locking push type : Non-locking push type (projecting) Grommet terminal with light/surge voltage suppressor with light/surge voltage suppressor IN terminal IN terminal with light/surge voltage suppressor with surge voltage suppressor with light/surge voltage suppressor with indicator light Valve Valve Valve to 9 Valve to 9 xcept rated voltage: 6, 7 and 9. IN terminal be sure to add suffix -X00 at the end of the part number. In this case, pilot solenoid valve is VO307-.

Coolant Valve: ir Operated/xternal Pilot Solenoid JIS Symbol Valve type Operation ir operated N.C. 0 (P) N.O. 0 0 (P) Port low characteristics Mass (kg) Orifice dia. Note) ir xternal pilot hreaded ø (mm) v x 0-6 m operated solenoid -6-8 -0-0 8 3 8 7 30 3 36 95 0. 0.3-0 5 0 0.5 0.7-5 0-5 5 0 3-0 3 70 3-0 0 60-5 6 0-5 5 370 5-3 00 5-3 3 560 5-3 00 3 5-3 3 560 6-0 8 630 6-0 0 6-0 8 70 0 6-0 0 960 7-33 990 7-0 7-33 000 7-600 0.8.. 5.0 3.6 6.8 5.5 0..0.. 5. 3.8 7.0 5.7 0. Note) he companion flange is JIS 0 0K (standard) or its equivalent. xternal pilot solenoid (P) (P) 8-65 8-65 9-9 - Port Note) 65 Orifice dia. ø (mm) 5 65 56 low characteristics Cv ffective area (mm ) 9 8 70 60 73 00 00 0 Note) he companion flange is JIS 0 0K (standard) or its equivalent. Mass (kg) xternal pilot solenoid 5.7. Specifications luid (Main piping) luid temperature mbient temperature Proof pressure pplicable pressure range Coolant Note ) 5 to 60 C Note ) 5 to 99 C(ir operated type only) Note ) 5 to C (ir operated type: 60 C) Note ).5 MPa 0 to 0.5 MPa 0 to MPa Pressure 0.5 to 0.7 MPa xternal 0. + 0.5 x (Operating pressure) to 0.7 MPa Refer to Graph (). pilot air Lubrication Not required (Use turbine oil Class ISO VG3, if lubricated.) emperature 5 to C (ir operated type: 60 C) Note ) Mounting orientation Unrestricted Note 3) Pilot pressure (MPa) Note ) No freezing Note ) his product cannot be used in water. Note 3) or external pilot solenoid, it is recommended that the pilot solenoid valve be oriented either vertically upward or horizontally. Note ) Non-lubricant specifications are not available for this product. Graph () Pilot Pressure (N.O. type) 0.7 0.6 0.5 0. 0.3 0. 0. Pilot pressure should be within the range of against the operating pressure. 0 0. 0. 0.3 0. 0.5 0.6 0.7 0.8 0.9 Operating pressure (MPa) Pilot Solenoid Valve Specifications Pilot solenoid valve lectrical entry Coil rated voltage (V) C (/60 Hz) C llowable voltage fluctuation Coil insulation type emperature rise pparent power Power consumption Inrush C Holding C S- -3 Grommet Grommet terminal IN terminal to 9 VO30-00 -X30 00 V, 00 V, Other voltage (Option) V, Other voltage (Option) 5% to +0% of rated voltage Class or equivalent (30 C) 35 C or less (when rated voltage is applied.) 5.6 V ( Hz) 5.0 V (60 Hz) 3. V ( Hz).3 V (60 Hz).8 W (without light), W (with light) 70 C or less (when rated voltage is applied.) V ( Hz) 0.5 V (60 Hz) 7.5 V ( Hz) 6 V (60 Hz).8 W (without light), 5 W (with light) Non-locking push type, Non-locking push type Other (Option) Note) Refer to page 06 for how to order pilot solenoid valves. 0 VN VN VN

Construction N.C. o w i t r Port (P) Port 0(P) u In the case of 3 to y t e r i Port Port q N.C. (Return spring normally closed) When the pilot solenoid valve o is not energized (or when air is exhausted from the port (P) for air operated style), the valve body r connected to the piston y is closed by the return spring u. When valve body opens When the pilot solenoid valve is energized (or when pressurized air enters through the port (P) of the air operated style), the pilot air that has entered under the piston moves upward to open the valve element. When valve body closes When the power to the pilot solenoid valve is turned off (or when fluid is exhausted from the port (P) of the air operated style), the pilot air under the piston is exhausted, and the return spring closes the valve element. N.O. Component Parts No. escription Material Note ody assembly Cast iron Plated 3 Cover assembly Plate assembly Valve element luminum alloy Iron Stainless steel Platinum silver painted Valve composition, NR, KM 5 Valve cover NR, KM 3 to are O-ring. 6 Piston assembly luminum alloy 7 Return spring Piano wire 8 Spiral pin Stainless steel 9 Pilot solenoid valve Note) 3, 5 components determine the valve composition. Replacement Parts Part no. No. escription -6, 8, 0-0, 5 3-0 -5 5-3, 3 6-0, 0 7 -, 3 Plate ass'y Seal NR VN-3C VN3-3C VN-3C VN5-3C VN6-3C VN7-3C material KM VN-3C VN3-3C VN-3C VN5-3C VN6-3C VN7-3C 5 Valve cover Seal NR Refer to Note ) VN-C VN-C (3 to are O-ring.) material KM VN-C VN-C S568-00 S568-0 S568-0 8 Spiral pin VN-60- Refer to Note ) VN-60- VN5-60- VN6-60- VN7-60- 9 Pilot solenoid valve S- -3 VO30-00 -X30 (Refer to page 06 for part no.) Note ) Request factory repair. Note ) or 3 use VN3-60-, and for 3 use VN-60-. Replacement Parts: pplicable No. escription 8-65 Part no. 9-3 NR Plate assembly Seal VN8-3C VN9-3C material KM VN8-3C VN9-3C 8 Spiral pin VN7-60- 9 Pilot solenoid valve VO30-00 -X30 (Refer to page 06 for part no.) 0 u N.O. (Return spring normally open) In contrast with the N.C., when the pilot solenoid valve is not energized (or when air is exhausted from the port 0(P) of the air operated style), the valve body is opened by the return spring. When the pilot solenoid valve is energized (or when pressurized air enters through the port 0(P) of the air operated style), the valve body closes.

Coolant Valve: ir Operated/xternal Pilot Solenoid hreaded ype/port : 6, 8, 0 Pilot port (P) x 8 (ack side 0(P)).5 39.5 (Non-locking push type) 7 (:, IN terminal: ) 08. (Grommet terminal: ) 06.7 (Grommet: G) 63 (ir operated) 6 (.6) 7 Main port (ack side port ) Port : refer to table below 5 65 (Grommet terminal: ) 70 (: ) 7 (IN terminal: ) racket x ø.5 x M x 0.7 depth 7-6 -8-0 Main port, 8 3 8 8 0 8 In the case of Z or Z or Z, the length is longer by 9 mm. VN VN VN 03

hreaded ype/port : 0, 5, 0, 5 lectrical entry port: G / x øn (Non-locking push type) Pilot port (P) x 8 (ack side 0(P)) racket Main port (ack side port ) Port : refer to table below -0-5 3-0 -5 Main port, 3 8 3 63 63 90 60 C 8 8 35 0 7.5 0 7.5 7.5 8 00.5.5 9 08 H 87 87 9 93 J K.5 8.5 8 9 59.5 08 75.5 L 5 5 6 7 M 6 6 3 36 N.5.5 5.5 6.5 P.3.3 8.3 33.3 Q.3.3.3.3 R 5 5 30 35 S 3 3 3 9 55 55 60.5 73 hreaded ype/port : 3, 0, lectrical entry port: G / Pilot port (P), 0(P) Port : refer to table below (Non-locking push type) Main port (ack side port ) Port : refer to table below 5-3 6-0 7 - Main port, Pilot port (P), 0(P) 8 05 0 0 77 96 3 C 53 60 7 6.5 30 37 0.5 37 60 0 H 9.5 7 70 J 9.5 7 70 K 97.5 37.5 L 55 63 7 0

Coolant Valve: ir Operated/xternal Pilot Solenoid ype/port : 3, 0, lectrical entry port: G / Pilot port (P), 0(P) Port : refer to table below (Non-locking push type) x x ø8 mouting hole 5-3 6-0 7 - pplicable flange Port, Pilot port (P), 0(P) 3 8 0 30 0.5 6 C 35 0 55 3 6 6.5 0 00 05 0 H 36 5 J K 30.5 36 3 L 78 93.5 37.5 ype/port : 65, lectrical entry port: G / Pilot port (P), 0(P) (Non-locking push type) VN VN x x ø8 mouting hole (: 8 x x ø8) VN 8-65 9 - pplicable flange Port, 65 0 0 305.5 3.5 C 75 85 0 35 0 65 H 05.5.5 05

How to Order Pilot Solenoid Valves Valve Valve to 9 S Z 3 Coil rated voltage 3 5 6 7 9 00 VC /60 Hz 00 VC /60 Hz 0 VC /60 Hz 0 VC /60 Hz VC VC 0 VC /60 Hz Other Nil Non-locking push type Non-locking push type (projecting) Slotted locking type (tool required) Light/Surge voltage suppressor Nil None With light/surge voltage Z suppressor (xcept type G ) With surge voltage suppressor S (ype G only) lectrical entry G Grommet Grommet terminal IN terminal VO30 00 X30 Coil rated voltage 00 VC /60 Hz 00 VC /60 Hz 3 0 VC /60 Hz 0 VC /60 Hz 5 VC 6 VC 7 0 VC /60 Hz 9 Other ccessory unction plate ( seal, with thread): X060-3- Light/surge voltage suppressor Nil None With surge voltage S suppressor Z With light/surge voltage suppressor L With indicator light xcept VC, 0 VC, other voltages. 06

Specific Product Precautions e sure to read this before handling. Refer to front matters and 3 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for luid Control Precautions. xternal Pilot Caution Pilot port (P) and 0(P) piping P and P piping should be as follows according to the model. Port (P) ir operated 0 0 xternal pilot leed port Solenoid xternal pilot 0 leed port xternal pilot Pilot exhaust (P) Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention. Piping Caution When high temperature fluids are used, use fittings and tube with heat resistant features. (Self-align fittings, eflon tubing, Copper piping, etc.) Pilot Solenoid Valve Warning With external pilot solenoids, the pilot solenoid valves are not splash proof specifications, and so care must be taken not to get fluid on oneself such as when performing maintenance. Caution irection of mounting When replacing a valve, if an external pilot solenoid valve is mounted in the wrong direction, it may malfunction or leak air. Water Hammer Characteristics (N.C. 0.9 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.9 MPa (N.C. 0.97 MPa).5 Conditions: Piping 30 m Steel tube, total pressure 0.97 MPa Peak pressure at valve closed (MPa) 0.8 0.6 0. 0. 5 65 0 3 0 5 Peak pressure at valve closed (MPa).6. 0.8 0. 8 65 0 3 5 5 0 0 3 5 low velocity (m/s) Calculating the low Velocity v =. x Q/d 0 3 5 6 low velocity (m/s) VN VN (Symbol) v: flow velocity (m/s) Q: flow rate (l/min) d: piping inner diameter (mm) VN 07