USE OF MAZZEI INJECTORS IN PRESSURIZED SPRINKLER APPLICATIONS

Similar documents
(3) (4) (6) (5) (10) (9) (8) (7)

PRODUCT CATALOG Agriculture

KIT CR-4 3/4" MALE STRAIGHT THREAD NOTES: MADE IN THE U.S.A. U.S. PATENT No. 5,863,128. U.S. No. 3,852,076 AND INTERNATIONAL REGISTERED TRADEMARKS

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

MANUAL FOAM SYSTEM MODELS: MFA200 CLASS A FOAM MFA201 CLASS B FOAM MFA220 CLASS A and B FOAM

KIT CR-4. 3mm.13in UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES NOTES: MADE IN THE U.S.A. U.S. PATENT No. 5,863,128

Fact File 59 Extinguishing systems

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

Installation Manual. Model # SF-4W rev.4 (02/28/14) 1200 Lower River Road, P.O. Box 800 Charleston, TN PULSAR

NOTES: MADE IN THE U.S.A. U.S. PATENT No. 5,863,128. U.S. No. 3,852,076 AND INTERNATIONAL REGISTERED TRADEMARKS

Series

Simple Carburettor Fuel System for a Piston Engine. And how it works

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Duplex Commercial Pressurizer -DCP

Operating and Installation Instructions

1. MAJOR COMPONENTS IN ENGINE AND ENGINE COMPARTMENT

WG / WGS HIGH PRESSURE BOOSTER PUMPS

Direct-Operated Pressure & Temperature Regulating Valves

Section R Foam Systems

Section R Foam Systems

2. Turbocharger System

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

UNIMIX EM. Operations Manual. Supplied by:

June Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.

EZ SDI TM Booster Pump Assembly

K-Rain - Hydrotek Valves Instructions

To ensure proper installation, digital pictures with contact information to before startup.

Bendix BA-921 Compressor

MICROPUMP MAG-DRIVE GEAR PUMPS

Water. Series VA. Air Release and Vacuum Break Valves for Water Pipelines

cs200 series commercial / Industrial pressure reducing regulators

Case Study Balancing a System

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description

COMMON RAIL SYSTEM (CRS)

Sewage. Series VG. Air Release and Vacuum Break Valves for Sewerage and Slurry Pipelines

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

CASH VALVE K SERIES BACK PRESSURE VALVES

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps

Modeling a Sprinkler System or a System With Nozzles

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Darley UHP-HV Diesel Specification 1

Components of Hydronic Systems

ENGINE TECH TIPS. Subject: OIL IN TURBOCHARGER AND AIR PIPING

HP FUEL PUMPS P/N ERL & ERL Installation Instructions 199R11108

WARCO CHEMAG SERIES GH FILTERS

RS Series Multi-stage, Ring Section Pump For Pressures to 1,500 PSI

Applications Closed Head Foam-Water Sprinkler Systems Aircraft Hangars Flammable Liquid Warehouses, Drum Storage Facilities

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

TYPE PC Propeller Condensate Pumps

Overview of Technical Advantages and Product Design. G.S. Presser, P. Eng. November 2004

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

WAFER STYLE ILBP PROPORTIONING MODULES WITH CHECK VALVE. NPR160 Approvals: UL, ULC

F - BASIC TESTING Infiniti G20 INTRODUCTION PRELIMINARY INSPECTION & ADJUSTMENTS VISUAL INSPECTION MECHANICAL INSPECTION

LIQUEFIED GAS PUMP INSTALLATION

SECTION A Engine 3.7L

OPERATOR S MANUAL AND PARTS LIST

Start-Up and Installation Checklist

DOMINATOR FUEL PUMPS P/N & Installation Instructions 199R10573

Series TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection

Description. ST-164 Dual injector. User Manual ST-164. Artikel-Nr.: XXX

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

Engine Power Output Low

512 HO M285 Engine (FrechW) Maybach Engine M285

1. The fuel delivery system uses the crankshaft position (CKP) sensor to signal the PCM that the engine is either cranking or running.

FUEL RAILS/PLUMBING - SIDE FEED INJECTORS. Application: US Spec STI-04/06, ROW 06. APS High Output Fuel System APSSTI-FRP/01 Installation Guide

50/60Hz DOOCH PUMP. 두크펌프 Horizontal centrifugal pump. Water supply system. Washing system. Industrial plants

J Series Filters HIGH PRESSURE FILTERS. J88 Mini In-Line (Replaceable Filter) J85 Tee-Type. J82 Mini In-Line. J83 In-Line

INJECTOR COMPONENTS SF-18. Air Cleaner Hose. Accelerator Cable Water Bypass Hose Air Hose. PCV Hose. Throttle Position Sensor Connector.

+\YH4(*;4 >H[LY 7YLZZ\YL )VVZ[LY :`Z[LT 0UZ[HSSH[PVU 0UZ[Y\J[PVUZ +\YH4(*

3061, 3096, 3126 foam systems gpm Installation Instructions

Minuteman Vertical Pumps

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Underground Tank Applications Installation Guide

SEAL RING (KIT CR4) BALL (KIT CR4) SPRING (KIT CR4) 3/4" MALE STRAIGHT THREAD

Operating Principle. Rotary Vane Compressor

1996 Toyota Camry DX ENGINE PERFORMANCE Toyota Basic Diagnostic Procedures

BOOSTER PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

GF07.16-P-9997OGG Overview of system components for common rail diesel injection (CDI)

HP FUEL PUMPS P/N & Installation Instructions 199R10569

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Fuel System Diagnosis

Dosage Pumps - Installation Guide

M50 L50 Series Multistage Regenerative Turbine Pumps

Part #82064 Add-A-Stage EFI Nitrous System

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

OBSOLETE DESIGN DATA. 3", 4", 6" and 8" CONCENTRATE CONTROLLERS

AGRICULTURE HORTICULTURE GREENHOUSE

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

AGRICULTURE HORTICULTURE GREENHOUSE

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 10 Apparatus Service Tests Revised

Transcription:

USE OF MAZZEI INJECTORS IN PRESSURIZED SPRINKLER APPLICATIONS The selection, installation and use of Mazzei Injectors in pressurized sprinkler systems are simple and straightforward. There are several steps, however, which should be understood and completed prior to installation. A. STEP ONE: Gathering Data Before a Mazzei Injector may be selected or installed, the following information should be obtained: 1. Sprinkler Pump Information a. Copy of pump curve b. Maximum discharge pressure c. Maximum flow rate 2. Sprinkler Information a. Name, model number, etc. b. Number of sprinklers c. Volume per sprinkler d. Minimum pressure requirements 3. Injection Requirements a. What do you want to inject? b. How much of the above do you want to inject? Per hour? Per Day? B. STEP TWO: Injector Selection Once the above information has been obtained, a suitable Mazzei Injector can be selected. Please refer to the "Required Information" sheet attached. The injector should be selected to have enough suction capacity at actual operating conditions to meet your injection requirements. C. STEP THREE: Selection of Installation Method There are several methods for installation of a Mazzei Injector into a pressurized sprinkler system. These are illustrated in the attached "Typical Installations."

Page 2 of 5 PRESSURIZED SPRINKLERS For most installations the choice will be between three methods: (1) In-Line, with all of the water flow going through the Mazzei Injector, (2) in a Bypass Assembly with only part of the water flow going through the injector, or (3 ) with a Booster Pump to supply the inlet water pressure required by the injector. Before you decide how the injector should be installed, it is important to fully understand just how a Mazzei Injector operates. In simple terms, a Mazzei Injector is a differential pressure Venturi eductor. When a sufficient pressure differential is established between the inlet and outlet ports of the injector and when sufficient water is flowing through the injector, suction is created at the suction port of the injector. Each Mazzei Injector has its own requirements for minimum flows and minimum pressure differentials to initiate suction. If either of these requirements is not satisfied, water will flow through the injector but suction will not be created. Please refer to the Performance Data - Injectors section on the Mazzei website (www.mazzei.net) for a complete listing of Performance Tables and minimum pressure differentials. 1. In-line Installing the Mazzei Injector in-line is the simplest and most straightforward method. This method will only work, however, if the sprinkler pump has enough discharge pressure to create a sufficient pressure differential across the Mazzei Injector and still provide sufficient flow and pressure to operate the spr inklers. For instance, if the sprinkler pump has a maximum discharge pressure of 60 psig and the sprinklers require a minimum of 51 psig to operate, there will not be enough pressure differential [((60-51)/(60))X100=15%] for the Mazzei Injector to operate properly. The sprinkler pump should be capable of creating at least a 25% pressure differential for the Mazzei Injector to operate properly. In this case, the pump should have a minimum discharge pressure of 68 psig (plus line losses), [((68-51)/(68))X100=25%]. If the sprinkler pump cannot meet these requirements, this method should not be used. Also, the sprinkler pump must produce adequate flow through the injector to provide the minimum flow requirements as listed in the Performance Tables. 2. Bypass Assembly In many pressurized sprinkler applications, the in -line method of installation will not be feasible. For these systems, the bypass method is an option. An example of a bypass is shown in the attached "Typical Installations." The purpose of the bypass method is twofold: first, to provide adequate flow and sufficient pressure differential across the injector so that the injector will operate properly, and second, to allow excess water not required to operate the injector to flow through the bypass and then to the sprinklers. There are two types of bypass assemblies. The first is the " manual" assembly. This uses a manually operated valve to direct sufficient flow to the injector. The second is the "automatic" assembly. The "automatic" assembly uses an

Page 3 of 5 adjustable, spring-loaded check valve to force water first through the injector. When the injector flow has been satisfied and a sufficient pressure differential generated across the check valve, the check valve will open and permit excess water flow through the valve. 3. Booster Pump Some installations will not work with either of the two methods described above. Another option method is to use a booster pump. This type of installation is also shown in the attached "Typical Installations." The booster pump must be sized properly to generate adequate flow through and sufficient pressure differential across the injector. Suction for the booster pump should be taken from the main flow line between the sprinkler pump and the sprinklers. Discharge for the booster pump should be back into the same line at a location downstream of the booster pump suction. The booster pump should be wired into the system so that it operates only during the sprinkler pump cycle. Power may be taken from the sprinkler pump electrical circuit by means of a relay. D. STEP FOUR: Additional Considerations Mazzei Injectors should always be installed in a manner and location that permits easy access for inspection and/or repair. The injectors themselves should be installed with unions so that they can easily be removed for inspection, cleaning or replacement. Ideally, pressure gauges should be installed before and after Mazzei Injectors so that pressure differentials can be established. Mazzei Injectors should always be installed in a horizont al or vertically up position (outlet above inlet). Installation in a vertically down position (outlet below inlet) may cause intermittent or erratic suction by the injector. If Mazzei Injectors are installed into a bypass assembly manufactured by the installer or dealer, full flow valves of the same size as the water line should be used.

Page 4 of 5 REQUIRED INFORMATION FOR GAS OR LIQUID INJECTION APPLICATIONS The following information and calculations are required to determine the proper size and model of Mazzei Injector for water treatment. 1. Total water flow of system (gpm or l/m): 2. Rate of injection required: (gpm or l/m for liquids)(scfh or l/m for gasses) 3. Pressure differential across injector a. System, or pump pressure at inlet to injector (psig or Kg/cm 2 ) b. Pressure (back-pressure) at outlet of injector (psig or Kg/cm 2 ) c. Available pressure differential (3a - 3b)(psig or Kg/cm 2 ) d. Percentage pressure differential[(3c / 3a) x (100)] % INJECTOR SELECTION The Injector Performance Tables shown on the Mazzei website (www.mazzei.net) in the Performance Data & Drawings Injectors section, list the motive flow values and suction capacities for all models of Mazzei Injectors at various differential pressure conditions. From the calculations above, use the Performance Tables to select an injector model that can exceed the required injection (suction) rate. The motive flow (water flow through the injector) must not exceed the total water flow of the system. If the required motive flow is less than the total water flow of the system, the injector may be installed in a "bypass" mode so that only part of the total water flow passes through the injector. 1. Locate the injector inlet pressure which most closely corresponds to your maximum available water pressure (3a above). 2. Locate the injector outlet pressure which most closely corresponds to your sys tem pressure downstream of the injector after installation. 3. Review the Performance Tables to locate an injector model which has a suction capacity that is greater than the required suction capacity. Use a metering valve or orifice assembly to obtain the precise suction required.

Page 5 of 5 TYPICAL INSTALLATIONS Injector installed across the differential pressure created by an existing booster or supply pump in the system. It is plumbed from the discharge side to the intake side of the pump. Injector installed around a point of restriction, such as a regulator valve or gate valve, which creates a differential pressure, thereby allowing the injector to produce a vacuum. Injector installed in by-pass line with flow control valve on main flow line. Installed in conjunction with a centrifugal pump to boost pressure through the injector thereby creating a differential pressure and producing a vacuum for chemical induction downstream from the pump. Installed directly in the main flow line with total flow of the system moving through the injector.