Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Similar documents
Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Ball valve for pipeline systems

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

Pressure Transmitter JUMO dtrans p30 Type

JUMO ecoline O-DO. Optical Sensor for Dissolved Oxygen. B Operating Manual /

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

J TS 7090 Thyristor power switch

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

Thermostats for panel mounting Series ETH

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Measuring Cells for free chlorine, chlorine dioxide, ozone

Surface-mounting Thermostats Series ATH-SW

Pressure transmitter JUMO dtrans p02

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Analog input module. Brief description. Page 1/8. Data Sheet

Panel-mounting Thermostats EM Series. B Operating Instructions 11.06/

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Pressure relief valve

Angle seat valve with piston actuator VZXA-...-K

SENSOFIT RET 5000 Technical Datasheet

Angle seat valve with diaphragm actuator VZXA-...-M

Declaration of Conformity as per Directive 97/23/EC

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Temperature Probes for Heat Meters

Angle seat valve with piston actuator VZXA-...-K

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Flow-Through Fitting ARF 215

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Pressure Transmitter JUMO dtrans p30 Type

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Ex m Solenoid Operator Type 0519

SensoLyt 700 SensoLyt 700 SW

SensoGate WA 130 H. User Manual. Retractable Fitting

ph-kompaktelektrodensystem sensopac CPA 320

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Contact information. Service Manual VX5-Dispenser. General fuell-dispensing.com (phone) (fax)

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Starting up hydraulic systems

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Operating Instruction for Flowmonitor. Model: DF-WM

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 6213 EV, 6281 EV

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

INSERTION Adaptor for analysis

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Pressure Relief Valve Overflow Valve Type DHV 715 Type DHV 716 Type DHV 725

JUMO tecline HD ph and JUMO tecline HD Rd

Betriebsanleitung / Operating Manual / Mode d emploi / Manual de operación ProMinent Dosiertechnik GmbH Heidelberg Germany

Installation and operating manual

Pressure Reducing Valve Type 2114/2415

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

Assembly and Operating Manual Membrane-Controlled Siphon Safety Device Type HS-F - Fixed Height Type HS-V - Adjustable Height

Diaphragm Valve, Plastic 2/2 way, motorized

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -450C,-750C, -1300C, -2500C. Service manual

Type 2000, 2002, 2012

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Technical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

N086, N186, N786. Pressure retaining valve, Plastic

Off-line filter system

Mechanical seals external, single or double type Crane 58U 58U

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

710, 717, 723. Ball Valve, Plastic

Digital ph transmitter

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

INSERTION Adapter/Fitting for analytical devices

GEMÜ 205 Electrically operated solenoid valve

High-speed detection even a little liquid leak

Inductive conductivity meter

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Diaphragm valve MV 309

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Visit us at

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

Digital ph transmitter

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Pressure transmitter for elevated media temperatures

FK DN PVC-U Butterfly valve

Visit us at

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

GEMÜ R680 Motorized diaphragm valve

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

General Specifications

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Transcription:

Flow Fittings for Electrochemical Sensors B 202810.0 Operating Manual 2013-06-12/0043166

Contents 1 Introduction......................................................5 1.1 Safety information............................................................. 5 1.2 Description.................................................................. 6 2 Identifying the device version.......................................7 2.1 Flow fitting for max. 3 measured value transducers................................... 7 2.1.1 Order details................................................................. 8 2.1.2 Accessories.................................................................. 8 2.2 Flow fitting for 1 measured value transducer........................................ 9 2.2.1 Order details................................................................ 10 2.2.2 Accessories................................................................. 10 3 Mounting.......................................................11 3.1 General information on mounting the flow fittings.................................... 11 3.2 General information on mounting electrodes in flow fittings............................ 11 3.3 Flow fitting for max. 3 measured value transducers.................................. 12 3.4 Flow fitting for 1 measured value transducer....................................... 13 3.5 Dimensions................................................................. 15 3.5.1 Flow fitting for max. 3 measured value transducers.................................. 15 3.5.2 Flow fitting for 1 measured value transducer....................................... 18 3.6 Accessories................................................................. 19 4 Technical data...................................................21 4.1 Flow fitting for max. 3 measured value transducers.................................. 21 4.2 Flow fitting for 1 measured value transducer....................................... 21 5 Maintenance and malfunction......................................23 5.1 Maintenance................................................................ 23 5.2 Malfunction................................................................. 24 3

Contents 4

1 Introduction 1.1 Safety information General information This manual contains information that must be observed in the interest of your own safety and to avoid damage to assets. This information is supported by symbols which are used in this manual as follows. Please read this manual before commissioning the device. Keep the manual in a place accessible to all users at all times. If difficulties occur during commissioning, please refrain from carrying out any manipulations that could jeopardize your warranty rights. Warning signs CAUTION! This symbol in combination with the signal word indicates that damage to assets or data loss will occur if suitable precautions are not taken. Note signs NOTE! This symbol refers to important information about the product or its handling or additional use. 5

1 Introduction 1.2 Description Additional fittings Flow fittings serve to accommodate electrochemical measured value transducers (e.g. ph and Redox combination electrodes, glass conductivity sensors, compensation thermometer, etc.) with Pg13.5 screw-in thread and an insertion length of 120 mm. Fitting types for 1 to 3 measured value transducers are available. The fittings are directly installed in feed pipes for material under measurement or in the bypass. They protect the installed sensors against breakage and their special design type ensures correct flow to the sensor, preventing measuring errors. Various fastening variants and materials are available. Other versions and materials can be offered on request. CAUTION! In the case of systems that are subject to pressurization and thermostress, the user must be sure to select the corresponding version of the fittings and the measured value transducers. When planning the piping, the following aspects are to be considered: Fittings must be easily accessible in order to enable regular maintenance/cleaning of the measured value transducers and/or the fitting Bypass measurements are recommended as the preferred option; it should be possible to remove sensors using shut-off valves When the plant is idle, the ph and Redox electrodes must not become dry for an extended period of time it must be ensured that the structure includes residual liquid in the fitting In the case of systems that are subject to pressurization and thermostress, the user must be sure to select the corresponding version of the fittings and the measured value transducers The system designer must check the suitability of the materials (e.g. chemical compatibility) prior to use in chemical media in particular, the resistance of the fittings and their materials must be checked and a leak test must be performed Fitting type Data sheet Flow fittings 202810 Immersion fittings 202820 Quick-change fittings 202822 Process fittings 202825 CAUTION! The mounting, startup, and maintenance must only be performed by expert personnel. CAUTION! Only original spare parts may be used for the fittings. 6

2 Identifying the device version 2.1 Flow fitting for max. 3 measured value transducers Fitting type 202810/03... is suitable for the insertion of 1 to 3 measured value transducers with Pg13.5 thread and an insertion length of 120 mm. The extra code "ground electrode" enables the discharge of undesired electrical and electrostatic voltage potentials, which occur in complex plants and can distort the measured values. Fittings with a measuring vessel made from polypropylene (PP) are deployed in cases where the transparent material PC (standard) is not suitable, e.g. processes with sharp (sudden) fluctuations in temperature. Type 202810/03-104-87-80/000 (1) (2) (1) Case (2) Measuring vessel 7

2 Identifying the device version 2.1.1 Order details 2.1.2 Accessories (1) Basic type 202810/03 Flow fitting for max. 3 measured value transducers with Pg13.5 thread (2) Process connection 104 Screw connection G 1/2 (3) Material 87 Polypropylene (PP) (4) Measuring cup material 080 Polycarbonate (PC) 087 Polypropylene (PP) (5) Extra codes 000 Without 055 Ground electrode (1) (2) (3) (4) (5) Order code - - - / Order example 202810/03-104 - 87-080 / 000 Article Part no. Replacement vessel made from polycarbonate (PC) incl. O-ring 00417498 Replacement vessel made from polypropylene (PP) incl. O-ring for versions with build year from September 2005 Replacement vessel made from polypropylene (PP) incl. O-ring for versions with build year up to August 2005 KCl storage vessel, pressure-resistant, for wall mounting; for inserting an electrolyte bridge or when using KCl-filled electrodes 00463367 00417499 00060254 Fixing bracket for wall mounting, stainless steel 1.4571 00455706 NOTE! For more information on inserting an electrolyte bridge or using KCI-filled electrodes, see Chapter 3.6 "Accessories", page 19. 8

2 Identifying the device version 2.2 Flow fitting for 1 measured value transducer Fitting type 202810/01... is suitable for the insertion of 1 measured value transducer with Pg13.5 thread and an insertion length of 120 mm. Angled seat version, type 202810/01-970-86 T-piece version, type 202810/01-968-86 9

2 Identifying the device version 2.2.1 Order details (1) Basic type 202810/01 Flow fitting for 1 measured value transducer (2) Process connection 965 Angled seat DN 20 966 Angled seat DN 25 967 T-piece DN 32 968 T-piece DN 40 969 T-piece DN 50 970 Angled seat DN 20 with screwed butt joint 971 Angled seat DN 25 with screwed butt joint (3) Material 86 Polyvinyl chloride (PVC) (1) (2) (3) Order code - - Order example 202810/01-970 - 86 2.2.2 Accessories Article KCl storage vessel, pressure-resistant, for wall mounting; for inserting an electrolyte bridge or when using KCl-filled electrodes Part no. 00060254 NOTE! For more information on inserting an electrolyte bridge or using KCl-filled electrodes, see Chapter 3.6 "Accessories", page 19. 10

3 Mounting CAUTION! Ensure that the thread and the O-rings are clean, otherwise liquid can penetrate the fitting. When inserting a glass electrode, note that the glass membranes may break easily in the event of improper handling. NOTE! An impedance converter (see data sheet 202995) can be mounted between the ph electrode and the cable socket N. NOTE! Observe the following important information when mounting: The fitting must be mounted in the correct installation position and operated in the correct flow direction. PVC fittings must be mounted in the piping system using the correct adhesive. PVC fittings with screwed butt joint must not be mounted with pipe wrenches, as the union nuts are then overtightened and may rupture. 3.1 General information on mounting the flow fittings Ensure correct installation position For service and maintenance work, the installation location must be easily accessible; therefore, avoid installing in inaccessible locations Chapter 4 "Technical data", page 21 3.2 General information on mounting electrodes in flow fittings Ensure correct installation position Screw the electrode into the fitting with the Pg thread, tightening only until the electrode is securely positioned; do not exceed the maximum tightening torque (max. tightening torque for ph electrodes 3.0 Nm) Chapter 4 "Technical data", page 21 CAUTION! The electrode must always be inserted vertically from above into the flow fitting never from below. CAUTION! Electrochemical sensors are sensitive products. Observe the respective specific features of the sensors (such as temperatures, pressure, etc.; see technical data), avoiding pressure surges and temperature fluctuations where possible. It is therefore recommended that the sensor is not installed in the main stream of a plant. In the case of installation in a bypass, you must provide shut-off valves in order for the sensor to be dry when it is removed for maintenance/cleaning. 11

3 Mounting 3.3 Flow fitting for max. 3 measured value transducers Type 202810/03... (1) (2) (6) (3) (5) (4) (1) Electrode (2) Washer (3) O-ring (4) Seal (5) Plug (6) Screw connection Step Activity 1 Filler plug: loosen screw connection (6). Remove plug (5) and seal (4). 2 Screw electrode (1) into the fitting vertically from above. CAUTION! Washer (2) and O-ring (3) must be present on the electrode shaft. Operation CAUTION! For pressure resistance, see technical data. 12

3 Mounting 3.4 Flow fitting for 1 measured value transducer Angled seat version, type 202810/01... (1) (2) (1) Electrode holder (2) Case T-piece version, type 202810/01... (1) (2) (1) Electrode holder (2) Case Step Activity 1 Remove sealing washer. 2 Screw electrode into electrode holder (1) in the case (2) from above. 13

3 Mounting CAUTION! Washer (2) and O-ring (3) must be present on the electrode shaft. Operation CAUTION! For pressure resistance, see technical data. 14

3 Mounting 3.5 Dimensions 3.5.1 Flow fitting for max. 3 measured value transducers Type 202810/03-104-87-80/000 (1) (2) (3) (4) (1) Case (2) Flow direction (3) Fastening hole (4) Measuring vessel 15

3 Mounting Fixing bracket, stainless steel 1.4571 (part no. 00455706) Front view Side view Flow fitting, mounted on fixing bracket Front view Side view 16

3 Mounting Ground electrode The ground electrode (extra code 055) enables equipotential bonding. The ground electrode can only be mounted at the factory! (1) (1) Front view Side view (1) Ground electrode 17

3 Mounting 3.5.2 Flow fitting for 1 measured value transducer Angled seat version DN ØD L2 L1 L1 Type DN Ø D in mm L in mm L 1 in mm L 2 in mm 202810/01-965-86 20 25 144 19 110 202810/01-966-86 25 32 154 22 115 Angled seat version with screwed butt joint L Ø D Ø D1 L2 (2) (1) L1 L (1) O-ring (2) Screw connection Type DN Ø D in mm ØD 1 in mm L in mm L 1 in mm L 2 in mm 202810/01-970-86 20 25 66 158 19 110 202810/01-971-86 25 32 75 176 22 115 18

3 Mounting T-piece version Vertical installation position Type DN Ø D in mm D 1 in mm L in mm L 1 in mm L 2 in mm 202810/01-967-86 32 40 51 129 112 47 202810/01-968-86 40 50 62 137 120 59 202810/01-969-86 50 63 77 147 130 72 3.6 Accessories KCl storage vessel The KCl storage vessel is intended for the mounting or use of an electrolyte bridge in cases where the material under measurement contains substances that affect the measurement or may chemically attack the reference electrodes. The storage vessel (part no. 00060254) is pressure-resistant and has a compressed-air connection and a fixing bracket made from stainless steel 1.4571 (part no. 00455706) for wall mounting. The KCl storage vessel can be impinged with up to 6 bar via the compressed-air connection. Mounting an electrolyte bridge For an electrolyte bridge, two separated electrodes (glass electrode [7] and reference electrode [1]) are required. The connection between the reference electrode (1) and the measurement medium (6) is established via a diaphragm tube (4), see illustration below. NOTE! The connection between the diaphragm tube and the KCI storage vessel must be free of air bubbles. Any air bubbles are to be removed by tapping the hose or diaphragm tube. 19

3 Mounting (1) (2) (3) (7) (4) (5) (6) (1) Reference electrode (2) KCl storage vessel (3) Plastic screw connection; outlet (4) Diaphragm tube (5) Flow fitting (6) Measurement medium (7) Glass electrode Step Activity 1 Fit the flow fitting (5) in the pipeline. 2 Mount the KCl storage vessel (2) on the wall, vertical installation position. 3 Insert the glass electrode (7) into the flow fitting (5). 4 Screw the reference electrode (1) into the KCl storage vessel (2). 5 Connect both vessels to one another via the diaphragm tube (4) and fill the storage vessel with KCl. 20

4 Technical data 4.1 Flow fitting for max. 3 measured value transducers Type 202810/03... Materials Admissible temperature a, b Case: polypropylene (PP) Measuring vessel: polycarbonate (PC) or polypropylene (PP) Seals: FPM 0to90 C Pressure resistance a, b 1bar at 90 C, 6bar at 25 C Electrode holder Process connection Installation position Protection type Weight a Please also observe the maximum operating data of the sensor in use. b The data is based on the medium of water. Pg13.5 screw connection for 1 to 3 measured value transducers (filler plugs provided) G 1/2 A Vertical, with electrode holder pointing upward IP65 EN 60529 Approx. 400 g 4.2 Flow fitting for 1 measured value transducer Type 202810/01... Materials Admissible temperature a, b Pressure resistance a,b Electrode holder Process connection Installation position Protection type Weight Flow body: PVC Electrode holder: PVC 0to60 C PN 10 for T-piece: 10 bar at 0 to 20 C, 3 bar at 60 C PN 10 for angled seat DN 20/25: 10 bar at 0 to 20 C, 2.75 bar at 60 C PN 16 for angled seat with screw connection DN 20/25: 16 bar at 0 to 20 C, 4.25 bar at 60 C Pg13.5 screw connection for 1 measured value transducer Bonded sockets Angled seat fitting: inserted vertically into the pipeline, with the case pointing upward T-piece: horizontal to pipeline, with the electrode holder pointing upward IP65 EN 60529 approx. 340 g a Please also observe the maximum operating data of the sensor in use. b The data is based on the medium of water. NOTE! With regard to the illustrations of the stipulated installation positions, see Chapter 3.3 "Flow fitting for max. 3 measured value transducers", page 12, and Chapter 3.4 "Durchflussarmatur für 1 Messwertaufnehmer", page 13. 21

4 Technical data Temperature/pressure diagram for T-piece and angled seat fitting P 16 PN 16 14 12 10 PN 10 8 6 4 2 0 0 20 60 T Temperature in C P Admissible pressure in bar The data is based on the medium of water. T NOTE! If the temperature increases, the nominal pressure should be reduced. 22

5 Maintenance and malfunction 5.1 Maintenance NOTE! The maintenance must only be performed by expert personnel. NOTE! The fittings must be cleaned regularly. The cleaning interval and cleaning agent are determined by the type and level of pollution. The use of concentrated aggressive chemical cleaning agents and solvents is generally not recommended. If these agents are used for cleaning purposes, however, then the material compatibility must be checked in advance. The case can be opened for cleaning/maintenance purposes through the screw connection. Each time the screw connection is opened, the O-rings depending on the measurement medium are to be lubricated with a suitable lubricant, e.g. Vaseline, and the sealing surfaces are to be checked for damage. CAUTION! In order to clean and calibrate the measured value transducers, the fitting must be pressureless. Take suitable measures to prevent dry running of the line (shut-off valve or similar). 23

5 Maintenance and malfunction 5.2 Malfunction NOTE! Damaged sealing surfaces or O-rings can lead to liquid escaping from the fitting. In this case, the fitting must be shut off immediately and maintenance must be performed. If... If the flow through the fitting is poor or insufficient, If the fitting is not sealed, If the potential for wear and tear depends on the exposure to chemicals, Then... avoid sharply fluctuating or jerky pressure changes and air bubbles. check that all moving parts have been screwed at least hand-tight, that all seals have been inserted and are undamaged, that the plant pressure is not too high and that there are no visible cracks in the fitting case. regularly check the seals and replace these as necessary, and pay attention to material changes (brittleness of the plastic, etc.) as these restrict the max. admissible pressure and temperature range. 24

JUMO GmbH & Co. KG Street address: Moritz-Juchheim-Straße 1 36039 Fulda, Germany Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow - Essex CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 63 52 62 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. 6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com