Product Data Sheet. Turbine Flow Meters. Precision Series DESCRIPTION CALIBRATIONS APPLICATIONS

Similar documents
Product Data Sheet. Exact Dual Rotor. Turbine Flow Meters DESCRIPTION CALIBRATIONS APPLICATIONS

Product Data Sheet. Positive Displacement Flow Meter B1750 DESCRIPTION

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

Product Data Sheet. Flow Monitor. B2800 Series DESCRIPTION OPERATION FEATURES

Product Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS

Parts List. Recordall Turbo Series Meters

Product Data Sheet. Electronic Valve Actuator. SEVA (Smart Electronic Valve Actuator) DESCRIPTION FEATURES APPROVALS / RATINGS OPERATION

Product Data Sheet. Industrial Oval Gear. Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION OPERATING PRINCIPLE

Variable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement.

Product Data Sheet DESCRIPTION

Turbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015)

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

Product Data Sheet DESCRIPTION

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE

Product Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8, 5/8 x 3/4, 3/4 & 1 inch NSF/ANSI Standards 61 and 372 Certified

Product Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8", 5/8" x 3/4", 3/4" & 1" NSF/ANSI Standards 61 and 372 Certified

Product Data Sheet. Coriolis Flow Meter RCT1000 DESCRIPTION APPLICATIONS MAINTENANCE OPERATION FLUID DIAGNOSTICS ADVANTAGES

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Product Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION

Turbine Flow Meter B1500. User Manual. TRB-UM EN-02 (June 2016)

Product Data Sheet. Recordall Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass DESCRIPTION

Automotive Flow Measurement and Control Products

User Manual. Ellipse Pitot Tube Meter. PFA Fire Pump System. PTT-UM EN-03 (March 2017) 2500 GPM 3000 F M

Control Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014)

User Manual. Industrial Meters. Oscillating Piston, Sizes 1/2", 1" and 2" Model OP Sanitary (3A Approved) and Model OP Chemical

Turbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016)

Electronic Preset Meter. Model EPM2-ADV-SF, Advanced Series, Special Fluids. User Manual. AUT-UM EN-05 (August 2015)

Industrial Meters. Oscillating Piston, Model OP Chemical & Sanitary, Sizes 1/2", 1", 2" User Manual. OPM-UM EN-02 (August 2013)

Turbine Flow Meter. User Manual. Top Load 1 in. and 2 in. Meters. TRB-UM EN-01 (September 2018)

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

Industrial Turbo Meters. Sizes 2 in. through 6 in. User Manual. TUR-UM EN-21 (October 2017)

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual

PFM Portable Hydraulic Testers. PFM6, PFM6BD and PFM8. User Manual. TUR-UM EN-02 (August 2014)

Precision Flow Measurement Solutions. Test and Measurement

Turbine Flow Sensors. Activa, Ultima, Classic and Quad. User Manual. SEN-UM EN-02 (March 2015)

Recordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM EN-02 (October 2013) User Manual

FT Series. Turbine Flowmeters. Description. Features. Applications. Operation. FT Series Turbine Flowmeters

U500w Ultrasonic Meter. Cold Water Meters. User Manual. ESM-UM EN-04 (September 2017)

User Manual. Recordall Compound Series Meter. Lead-Free Bronze Alloy, Sizes 2", 3", 4" & 6" NSF/ANSI Standards 61 and 372 Certified

VN2000 Flow Meters. Hot Tap Insertion Meter. User Manual. VRX-UM EN-03 (April 2018)

Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual

Installation & Operation Manual. Impeller Flow Sensors. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Vortex Flow Meters. Shedding Flow Meter RVL Series. User Manual. VRX-UM EN-03 (April 2017)

User Manual. Intrinsically Safe Flow Meters. RWG/RWBG Wafer Style Flow Meters RNG Insertion Style Flow Meters. VRX-UM EN-03 (October 2014) Flow

Variable Area Flow Meters. Inline Pneumatic Flow Meter. User Manual. VAM-UM EN-02 (August 2014)

Hoffer Engineering Guide for Liquids

WATER METER MATERIAL & ORDER INFORMATION

Liquid Turbine Flowmeters

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Flow-Alert. Flow Switch GPM LPM OIL FLOW-ALERT FLOW SWITCH 6000 PSI / 414 BARS MAX. User Manual. VAM-UM EN-02 (September 2014)

PA - Turbine Flowmeter Range

BARTON 7000 Series Liquid Turbine Meters

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

High Performance Turbine Technology

PFM Portable Hydraulic Testers. PFM6, PFM6BD, and PFM8. Badger Meter. Installation & Operation Manual. 05-TUR-UM EN (September 2012)

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

VB-7000 Series 1/2 to 2 Globe Valves

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

Liquid Turbine Flowmeters

Micro-Machined Silicon Transducers

Flow Sensors. Series 228PV PVC Tee Type Flow Sensors. User Manual. SEN-UM EN-10 (February 2018)

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

Technical Datasheet. ZHM CT Series. Gear Flow Meters in Cartridge Design.

Transmitting Transducer. Gas/Air Velocity Range:

F-1500 SERIES INSERTION TURBINE FLOW METER

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

BARTON 7400 Precision Gas Turbine Flow Meters

F-2700 SERIES INSERTION VORTEX FLOW METER

Technical Data. Series Oval Flowmeter. Model 9400

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

Certified according to DIN EN ISO Technical Datasheet. HM Series. Turbine Flow Meters

F-2600 SERIES INLINE VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

G2 SERIES INDUSTRIAL GRADE METERS

Thermo Scientific Gilmont

WATER & IRRIGATION METERS QUALITY FLOW METERS FOR THE AGRICULTURE AND AQUIFER MANAGEMENT. Quality Engineered Systems

Liquid Turbine Flowmeters

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Demanding Applications. Essential Fluids. For Your Challenging Automotive Applications...

Flow Research and Test Center

G2 Industrial Grade Meters

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Product Data Sheet. Transit Time Ultrasonic Flow Meters. TFX-500w Clamp-On Meter DESCRIPTION FEATURES BENEFITS OPERATION APPLICATION

CTR Series. Turbine low meters with conditioned output and built-in loading valve. Up to. Output Options. Features. Hydraulic measurement and control

Technical Datasheet HM Series Turbine Flow Meters Certified according to DIN EN ISO 9001

Glass Tube Full-View Flowmeters

Series TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION

Flow meters, Flow switches and Flow transmitters

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

HM...TRI. Turbine Flow Meters (Tri-Clamp) for pharmaceutical Applications. Technical Datasheet

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Transcription:

Turbine Flow Meters Precision Series DESRIPTION ox Precision Turbine Flow Meters have unprecedented mechanical linearity, resulting in minimizing, or negating, temperature induced viscosity influence. ox Precision Turbine Meters come with a variety of process fittings, sizes and options to accommodate the requirements of most applications while offering wide flow ranges. Features Expanded mechanical linearity Helical rotor design omprehensive pickoff selection High-Performance ceramic ball bearings 6-bladed rotor supports Facility with NIST traceable standards variety of end fittings enefits Increased usable flow range with less sensitivity to fluid temperature/viscosity effect on the output. Exceptional speed-of-response, with reduced pressure drop. Meets application requirements for temperature and electronic outputs. eramic bearings provide near-perfect roundness, higher Rockwell hardness and are lighter and more tolerant to temperature than 440 stainless steel bearings. They eliminate adhesive wear and perform well in non-lubricating liquids found in cryogenic fluids and water. Improved flow conditioning. Third party audits to ensure calibration uncertainty. Laboratory correlation to verify that all calibrators produce the same result. N, NPT, hose barb, flange, high pressure, tri-clamp and special fittings to meet specific installation configurations. LIRTIONS alibrations are accomplished by using various blends of solvent and oil to simulate actual fluid conditions. For varying process temperature conditions, multiple viscosity calibrations are used to develop a universal viscosity curve. UV calibrations enable a flow computer to track temperature and compensate for fluid viscosity. Flow Dynamics tailors calibrations to replicate process conditions so the meter is characterized to provide the best attainable accuracy. alibrations are performed by our Flow Dynamics NVLP (Lab ode 200668-0) accredited calibration facility located in Scottsdale Z, which uses primary standard calibrators, offering uncertainties of ± 0.05 percent of reading with ± 0.02 percent repeatability. Users can be assured that ox Precision Meters come with a best-in-class calibration, traceable to NIST standards. PPLITIONS ox Precision Flow Meters are the ideal solutions for standard and high pressure liquid flow applications in test and measurement and precision industrial processes, found in the automotive, aerospace and general industries. XX-DS-00169-EN-05 (ugust 2016) Product Data Sheet

Turbine Flow Meters, Precision Series OPERTION ND PERFORMNE s a fluid passes through the meter, the velocity of the fluid provides rotational energy on the rotor. The rotor blades, passing through a magnetic or radio frequency field, generate pulses proportional to flow. Each pulse is transmitted to the meter electronics, where it amplifies the pulse output. Outstanding mechanical linearity, up to 100:1, is achievable, depending on meter size. Paired with a flow processor, meter linearity improves from the standard ± 0.50 percent to within ± 0.1 percent of reading over the entire repeatable flow range, while providing fluid temperature viscosity compensation. Temperature effects on the meter bore diameter are compensated for by using thermal expansion coefficients, with Strouhal-Roshko equations, to provide a very accurate and repeatable volumetric flow rate. SPEIFITIONS Repeatability ± 0.02% of reading Linearity ± 0.50% (± 0.1% with flow processor) alibrator Uncertainty ± 0.05% of reading Frequency Output 1200 1500 Hz Response Time 2 3 ms (at 1.2 cst) ody 316 stainless steel Materials of Shafts 316 stainless steel onstruction Rotors 17-4 PH stainless steel earing eramic NNOTE: The flow data below represents two different pickoff types, radio frequency and magnetic. Radio frequency (RF) pickoffs extend the measurable linear flow range by eliminating magnetic induced drag. RF pickoffs require a power input, whereas magnetic pickoffs generate their own power to produce an output signal and typically, have greater tolerance to higher process temperatures. U.S. Standard Flow Data 8-4 8-6 8 10 12 16 20 gpm (lpm) 0.20 3.00 (0.76 11.36) 0.30 6.00 (1.14 22.71) 0.40 9.50 (1.51 35.96) 0.50 15.5 (1.89 58.67) 1.00 30.0 (3.78 113.56) 1.60 65.0 (6.06 246.05) 1.90 95.0 (7.19 359.61) arrier (RF) Linear Range 2 lb/hr (kg/hr) 76 1143 (34.47 518.46) 114 2286 (51.71 1036.91) 152 3619 (68.95 1641.55) 190 5905 (86.18 2678.46) 381 11,430 (172.82 5184.56) 610 24,765 (276.69 11,233.2) 724 36,195 (328.40 16,417.7) Linear Flow Ratio 15:1 20:1 24:1 30:1 30:1 40:1 50:1 gpm (lpm) 0.05 3.00 (0.19 11.36) 0.06 6.00 (0.23 22.71) 0.09 9.50 (0.34 35.96) 0.16 15.5 (0.61 58.67) 0.30 30.0 (1.13 113.56) 0.45 65.0 (1.70 246.05) 0.65 95.0 (2.46 359.61) Non-Linear Repeatable Range lb/hr (kg/hr) 19 1143 (8.62 518.46) 22.8 2286 (10.34 1036.91) 34.3 3619 (15.56 1641.55) 60.9 5905 (27.62 2678.46) 114 11,430 (51.71 5184.56) 171 24,765 (77.67 11,233.2) 247 36,195 (112.04 16,417.7) 24 2.60 155 (9.84 586.74) 990 59,055 (446 26,786.9) 60:1 1.05 155 (3.97 586.74) 400 59,055 (181.44 26,786.9) 32 3.10 310 (11.73...1,173.48) 1181 118,110 (535.69 53,573.7) 100:1 2.10 310 (7.95 1173.48) 800 118,110 (362.87 53,573.7) 1. Pressure drop is based on using MIL-PRF-17024E, Type II at 77 F, with a specific gravity of 0.77. 2. Linear flow range was developed using 1.2 centistokes. Flow Ratio (Turndown) 60:1 100:1 150:1 Δp 1 at Max. Flow PSIG (g/cm 2 ) 6.5 (0.46) 8.5 (0.60) 8.5 (0.60) (0.63) (0.63) (0.63) 8.5 (0.60) (0.60) (0.63) Freq. Output at Max. Flow 1500 Hz Magnetic 10E:1 Linear Range Extended Range Linear 2 gpm (lpm) lb/hr (kg/hr) Δp 1 at 10E:1 PSID (kg/cm 2 ) K-Factor Pulses/ Gallon 3 (Liter 3 ) gpm (lpm) lb/hr (kg/hr) Flow Ratio (Turndown) Freq. at Min./Max. Output (Hz) 8-4 8-6 0.25 2.50 (0.95 9.46) 0.50 5.00 (1.89 18.93) 95 952 (43.09 431.82) 190 1905 (86.18 864.10) 3.5 (0.25) 4.5 (0.32) 28,800 (7610) 14,400 (3805) 0.25 3.00 (0.95 11.36) 0.50 6.00 (1.89 22.71) 95 1143 (43.09 518.46) 190 2286 (86.18 1036.91) 12:1 120/1440 12:1 120/1440 Page 2 XX-DS-00169-EN-05 ugust 2016

Product Data Sheet 8 10 12 16 20 24 32 0.75 7.50 (2.84 28.39) 1.25 12.5 (4.73 47.32) 2.50 25.0 (9.46 94.74) 5.00 50.0 (18.93 189.27) 7.50 75.0 (28.39 283.91) 12.5 125 (47.32 473.18) 25.0 250 (94.64 946.35) 285 2857 (129.27 1295.91) 476 4762 (215.91 2160.01) 952 9525 (431,82 4320.47) 1905 19,050 (864.09 8640.93) 2857 28,575 (1295.91 12,961.4) 4762 47,625 (2160.01 21,602.3) 9525 95,250 (4320.47 43,204.6) 6.0 (0.42) 5.0 (0.35) 5.0 (0.35) 5.0 (0.35) 5.5 (0.39) 6.0 (0.42) 6.5 (0.46) 9600 (2536) 5760 (1522) 2800 (761) 1440 (380) 960 (254) 576 (152) 288 (76) 0.60 0 (2.27 34.07) 1.00 15.0 (3.79 56.78) 1.50 30.0 (5.68 113.56) 2.50 60.0 (9.46 227.13) 3.00 90.0 (11.36 340.69) 5.00 150 (18.93 567.81) 6.20 300 (23.47 1135.62) 1. Pressure drop is based on using MIL-PRF-17024E, Type II at 77 F, with a specific gravity of 0.77. 229 3429 (103.87 1555.37) 381 5715 (172.82 2592.28) 571 11,430 (251 5184.56) 953 22,860 (432.27 10,369.1) 1143 34,290 (518.46 15,553.6) 1905 57,150 (864.09 25,922.8) 2362 114,300 (1071.39 51,845.6) 2. Extended range is linear, with liquids up to 1.5 centistokes. Over 2.0 centistokes, output becomes non-linear but repeatable. 3. K-factor varies slightly from meter to meter. Pressure Ratings for N End Fittings 15:1 96/1440 15:1 96/1440 20:1 72/1440 24:1 60/1440 30:1 48/1440 30:1 48/1440 48:1 30/1440 Meter odye: 316 Stainless Steel Pipe 100 F 300 F 500 F bar psig bar psig bar psig 8-4 0.25 in. (6.35 mm) 367 5330 299 4340 231 3350 8-6 0.37 in. (9.52 mm) 317 4600 245 3550 172 2500 8 0.50 in. (12.7 mm) 483 7000 388 5625 293 4250 10 0.62 in. (15.87 mm) 390 5660 319 4630 248 3600 12 0.75 in. (15 mm) 317 4600 245 3550 172 2500 16 1.00 in. (25.4 mm) 248 3600 193 2800 138 2000 20 1.25 in. (31.75 mm) 190 2760 157 2280 124 1800 24 1.50 in. (38.1 mm) 168 2430 135 1965 103 1500 32 2.00 in. (50.8 mm) 121 1760 97 1405 72 1050 Pressure Ratings for HP End Fittings ontinuous Proof urst psig bar psig bar psig bar ll sizes 5000 345 7500 517 25,000 1724 Pressure Ratings for NPT End Fittings ISO/NPT Pipe Female (Mating Thread) in. (mm) bar psig 8-4 0.25 in. (6.35 mm) 408 5922 8-6 0.37 in. (9.52 mm) 324 4700 8 0.50 in. (12.7mm) 305 4418 10 0.75 in. (15 mm) 285 4136 12 0.75 in. (15 mm) 285 4136 16 1.00 in. (25.4 mm) 278 4042 20 1.25 in. (31.75 mm) 324 4700 24 1.50 in. (38.1 mm) 291 4230 32 2.00 in. (50.8 mm) 253 3666 NOTES: 1. Pressure ratings listed are for temperatures up to 100 F (37.8 ). 2. Pressure rating is calculated with an allowable stress value of 20,000 psi for 316 SS per pressure piping code SME 31.3. 3. hart is displaying safe working pressure, in accordance with power piping code SME 31.1. NNOTE: It is recommended that the flow meter have N end fittings and that the NPT transition be done on the far ends of the flow straighteners. This avoids a step in the flow stream next to the flow meter and produces an improved flow profile. If the NPT end fittings were selected for their high pressure rating, then the step is unavoidable and the calibration will account for the distorted profile. ugust 2016 XX-DS-00169-EN-05 Page 3

Turbine Flow Meters, Precision Series Pressure Ratings for Flange End Fittings (in accordance with SME 16.5 Standards) NSI Flange PSIG ar 150# 275 19 300# 720 50 600# 1440 99 900# 2160 149 1500# 3600 248 2500# 6000 414 NOTES: 1. Specifications from maximum non-shock allowable working pressure in psig at 100 F (37.8 ) or less. 2. Stainless steel 316-181 material. Pressure Ratings for Tri-lamp End Fittings NNOTE: Pipe Meter odye: 316 Stainless Steel in. (mm) bar psig 8-4 0.25 (6.35) 153 2220 8-6 0.37 (9.52) 153 2220 8 0.50 (12.7) 153 2220 10 0.62 (15.87) 41 600 12 0.75 (15) 41 600 16 1.00 (25.4) 41 600 20 1.25 (31.75) 41 600 24 1.50 (38.1) 41 600 32 2.00 (50.8) 38 550 Specifications in this table are based on a Tri-lover clamp 13MHHS, with una-n material gaskets at a fluid temperature of 70 F (21.1 ). Other style clamps may produce different pressure ratings. Page 4 XX-DS-00169-EN-05 ugust 2016

Product Data Sheet DIMENSIONS Dimension specifies the most common pickup type. ctual size may vary depending on pickup choice. onsult the factory for details. N End Fitting HEX ODY SQURE ODY End Fitting (RF) (MG) 8-4 0.50 in. (12.70 mm) 2.45 in. (62.23 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square ody 8-6 0.50 in. (12.70 mm) 2.45 in. (62.23 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square ody 8 0.50 in. (12.70 mm) 2.45 in. (62.23 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.12 in. (28.45 mm) Square ody 10 0.625 in. (15.88 mm) 2.72 in. (68 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.25 in. (31.75 mm) Square ody 12 0.75 in. (15 mm) 3.25 in. (82.55 mm) 3.40 in. (86.36 mm) 2.90 in. (73.66 mm) 1.25 in. (31.75 mm) Square ody 16 1.00 in. (25.40 mm) 3.56 in. (90.42 mm) 3.50 in. (88.90 mm) 3.00 in. (76.20 mm) 1.63 in. (41.40 mm) Hex ody 20 1.25 in. (31.75 mm) 4.06 in. (103.1 mm) 3.60 in. (91.44 mm) 3.10 in. (78.74 mm) 1.88 in. (47.75 mm) Hex ody 24 1.50 in. (38.10 mm) 4.59 in. (116.6 mm) 3.80 in. (96.52 mm) 3.30 in. (83.82 mm) 2.25 in. (57.15 mm) Hex ody 32 2.00 in. (50.80 mm) 6.06 in. (153.9 mm) 4.00 in. (101.6 mm) 3.50 in. (88.90 mm) 2.75 in. (69.85 mm) Hex ody NPT End Fitting HEX ODY SQURE ODY End Fitting (RF) (MG) 8-4 0.50 in. (12.70 mm) 2.70 in. (68.58 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square ody 8-6 0.50 in. (12.70 mm) 2.70 in. (68.58 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square ody 8 0.50 in. (12.70 mm) 2.70 in. (68.58 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.12 in. (28.45 mm) Square ody 10 0.75 in. (15 mm) 3.29 in. (83.57 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.25 in. (31.75 mm) Square ody 12 0.75 in. (15 mm) 3.29 in. (83.57 mm) 3.40 in. (86.36 mm) 2.90 in. (73.66 mm) 1.25 in. (31.75 mm) Square ody 16 1.00 in. (25.40 mm) 3.78 in. (96.01 mm) 3.50 in. (88.90 mm) 3.00 in. (76.20 mm) 1.63 in. (41.40 mm) Hex ody 20 1.25 in. (31.75 mm) 4.23in.(107.4 mm) 3.60 in. (91.44 mm) 3.10 in. (78.74 mm) 1.88 in. (47.75 mm) Hex ody 24 1.50 in. (38.10 mm) 4.67 in. (118.6 mm) 3.80 in. (96.52 mm) 3.30 in. (83.82 mm) 2.25 in. (57.15 mm) Hex ody 32 2.00 in. (50.80 mm) 5.89 in. (149.6 mm) 4.00 in. (101.6 mm) 3.50 in. (88.90 mm) 2.75 in. (69.85 mm) Hex ody ugust 2016 XX-DS-00169-EN-05 Page 5

Turbine Flow Meters, Precision Series Flange End Fitting 2X FLNGES (PER SME 16.5) Ø (RF) (MG) 150# Flange 300# Flange 600# Flange 8-4 5.00 in. (127.0 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 3.50 in. (89 mm) 3.75 in. (95 mm) 3.75 in. (95 mm) 8-6 5.00 in. (127.0 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 3.50 in. (89 mm) 3.75 in. (95 mm) 3.75 in. (95 mm) 8 5.00 in. (127.0 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 3.50 in. (89 mm) 3.75 in. (95 mm) 3.75 in. (95 mm) 10 5.50 in. (139.7 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 3.50 in. (89 mm) 3.75 in. (95 mm) 3.75 in. (95 mm) 12 5.50 in. (139.7 mm) 3.40 in. (86.36 mm) 2.90 in. (73.66 mm) 3.88 in. (99 mm) 4.62 in. (117 mm) 4.62 in. (117 mm) 16 5.50 in. (139.7 mm) 3.50 in. (88.90 mm) 3.00 in. (76.20 mm) 4.25 in. (108 mm) 4.88 in. (124 mm) 4.88 in. (124 mm) 20 6.00 in. (152.4 mm) 3.60 in. (91.44 mm) 3.10 in. (78.74 mm) 4.62 in. (117 mm) 5.25 in. (133 mm) 5.25 in. (133 mm) 24 6.00 in. (152.4 mm) 3.80 in. (96.52 mm) 3.30 in. (83.82 mm) 5.00 in. (127 mm) 6.12 in. (155 mm) 6.12 in. (155 mm) 32 6.50 in. (165.1 mm) 4.00 in. (101.6 mm) 3.50 in. (88.90 mm) 6.00 in. (152 mm) 6.50 in. (165 mm) 6.50 in. (165 mm) Hose arb End Fitting 2X MS33658 END FITTINGS HEX ODY SQURE ODY End Fitting (RF) (MG) 8-4 0.50 in. (12.70 mm) 3.18 in. (80.77 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square body 8-6 0.50 in. (12.70 mm) 3.18 in. (80.77 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square body 8 0.50 in. (12.70 mm) 3.18 in. (80.77 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.12 in. (28.45 mm) Square body 10 0.625 in. (15.88 mm) 3.24 in. (82.30 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.25 in. (31.75 mm) Hex body 12 0.75 in. (15 mm) 3.25 in. (82.55 mm) 3.40 in. (86.36 mm) 2.90 in. (73.66 mm) 1.25 in. (31.75 mm) Hex body 16 1.00 in. (25.40 mm) 3.56 in. (90.42 mm) 3.50 in. (88.90 mm) 3.00 in. (76.20 mm) 1.63 in. (41.40 mm) Hex body 20 1.25 in. (31.75 mm) 4.50 in. (114.3 mm) 3.60 in. (91.44 mm) 3.10 in. (78.74 mm) 1.88 in. (47.75 mm) Hex body 24 1.50 in. (38.10 mm) 5.00 in. (127.0 mm) 3.80 in. (96.52 mm) 3.30 in. (83.82 mm) 2.25 in. (57.15 mm) Hex body 32 2.00 in. (50.80 mm) 6.50 in. (165.1 mm) 4.00 in. (101.6 mm) 3.50 in. (88.90 mm) 2.75 in. (69.85 mm) Hex body Page 6 XX-DS-00169-EN-05 ugust 2016

Product Data Sheet Tri-lamp End Fitting 2X TRI-LMP END FITTINGS (PER SME PE) End Fitting (RF) (MG) lamp 8-4 0.50 in. (12.70 mm) 3.56 in. (90.42 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.50 in. (38.10 mm) 8-6 0.50 in. (12.70 mm) 3.56 in. (90.42 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.50 in. (38.10 mm) 0.75 in. (15 mm) 8 0.50 in. (12.70 mm) 3.56 in. (90.42 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.50 in. (38.10 mm) 10 1.25 in. (31.75 mm) 3.56 in. (90.42 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.77 in. (44.96 mm) 12 1.25 in. (31.75 mm) 3.56 in. (90.42 mm) 3.40 in. (86.36 mm) 2.90 in. (73.66 mm) 1.77 in. (44.96 mm) 16 1.50 in. (31.80 mm) 3.56 in. (90.42 mm) 3.50 in. (88.90 mm) 3.00 in. (76.20 mm) 1.99 in. (50.55 mm) 1.50 in. (38.10 mm) 20 1.50 in. (31.80 mm) 4.59 in. (116.6 mm) 3.60 in. (91.44 mm) 3.10 in. (78.74 mm) 2.17 in. (55.12 mm) 24 1.50 in. (31.80 mm) 4.59 in. (116.6 mm) 3.80 in. (96.52 mm) 3.30 in. (83.82 mm) 2.38 in. (60.45 mm) 32 2.00 in. (50.80 mm) 6.06 in. (153.9 mm) 4.00 in. (101.6 mm) 3.50 in. (88.90 mm) 3.18 in. (80.77 mm) 2.00 in. (50.80 mm) High Pressure End Fitting (ompliant with S4375) HEX ODY SQURE ODY End Fitting (RF) (MG) 8-4 0.50 in. (12.70 mm) 3.25 in. (82.55 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square body 8-6 0.50 in. (12.70 mm) 3.25 in. (82.55 mm) 3.20 in. (81.28 mm) 2.70 in. (68.58 mm) 1.12 in. (28.45 mm) Square body 8 0.50 in. (12.70 mm) 3.50 in. (88.90 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.12 in. (28.45 mm) Square body 10 0.625 in. (15.88 mm) 4.00 in. (101.6 mm) 3.30 in. (83.82 mm) 2.80 in. (71.12 mm) 1.25 in. (31.75 mm) Square body 12 0.75 in. (15 mm) 4.50 in. (114.3 mm) 3.40 in. (86.36 mm) 2.90 in. (73.66 mm) 1.50 in. (38.10 mm) Square body 16 1.00 in. (25.40 mm) 4.75 in. (120.7 mm) 3.50 in. (88.90 mm) 3.00 in. (76.20 mm) 1.63 in. (41.40 mm) Hex body 20 1.25 in. (31.75 mm) 5.50 in. (139.7 mm) 3.60 in. (91.44 mm) 3.10 in. (78.74 mm) 1.88 in. (47.75 mm) Hex body 24 1.50 in. (38.10 mm) 6.00 in. (152.4 mm) 3.80 in. (96.52 mm) 3.30 in. (83.82 mm) 2.25 in. (57.15 mm) Hex body 32 2.00 in. (50.80 mm) 7.00 in. (177.8 mm) 4.00 in. (101.6 mm) 3.50 in. (88.90 mm) 2.75 in. (69.85 mm) Hex body ugust 2016 XX-DS-00169-EN-05 Page 7

Turbine Flow Meters, Precision Series METER MODEL NUMER ox Precision Turbine Flow Meters - - - - Model Precision Turbine PT Meter 8-4 (1/2" End Fitting, 1/4" ore) 84 8-6 (1/2" End Fitting, 3/8" ore) 86 8 (1/2" End Fitting, 1/2" ore) 08 10 (5/8" End Fitting) 10 12 (3/4" End Fitting) 12 16 (1" End Fitting) 16 20 (1-1/4" End Fitting) 20 24 (1-1/2" End Fitting) 24 32 (2" End Fitting) 32 End Fitting Type 37 MS Flare N National Pipe Thread NP High Pressure HP Hose arb H Tri-lamp T 150# NSI Raised Face Flange F1 300# NSI Raised Face Flange F2 600# NSI Raised Face Flange F3 earing Hybrid eramic all earing, Water/Hydrocarbon Service Pickoff RF 2-Pin MS -250 400 F RF 2-FL -250 400 F RF FL -330 450 F RTD RF 3-Pin MS -40 185 F Signal onditioner, IS RF 3-Pin MS -40 185 F mp, TEX, IS RF 3-Pin MS -40 248 F mp RF 6-Pin MS -49 284 F mp, RTD RF 6-Pin Micro DIN -49 284 F mp, RTD RF 3-FL -40 248 F mp MG 2-Pin MS -450 450 F s 8-4 and 8-6 45-55 G MG 2-Pin MS -450 450 F 8 32 140-150 G Specials 3-Digit Special ode (Leave blank for non-custom orders.) 01 02 03 04 05 06 07 08 09 M01 M02 XXX NNOTE: Higher flange ratings and other end fitting types can be provided. onsult the factory for pricing and delivery estimates. ontrol. Manage. Optimize. OX INSTRUMENTS is a registered trademark of adger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, adger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. 2016 adger Meter, Inc. ll rights reserved. www.badgermeter.com The mericas adger Meter 4545 West rown Deer Rd PO ox 245036 Milwaukee, WI 53224-9536 800-876-3837 414-355-0400 México adger Meter de las mericas, S.. de.v. Pedro Luis Ogazón N 32 Esq. ngelina N 24 olonia Guadalupe Inn P 01050 México, DF México +52-55-5662-0882 Europe, Middle East and frica adger Meter Europa GmbH Nurtinger Str 76 72639 Neuffen Germany +49-7025-9208-0 Europe, Middle East ranch Office adger Meter Europe PO ox 341442 Dubai Silicon Oasis, Head Quarter uilding, Wing, Office #209 Dubai / UE +971-4-371 2503 zech Republic adger Meter zech Republic s.r.o. Maříkova 2082/26 621 00 rno, zech Republic +420-5-41420411 Slovakia adger Meter Slovakia s.r.o. Racianska 109/ 831 02 ratislava, Slovakia +421-2-44 63 83 01 sia Pacific adger Meter 80 Marine Parade Rd 21-06 Parkway Parade Singapore 449269 +65-63464836 hina adger Meter 7-1202 99 Hangzhong Road Minhang District Shanghai hina 201101 +86-21-5763 5412 Switzerland adger Meter Swiss G Mittelholzerstrasse 8 3006 ern Switzerland +41-31-932 01 11 Legacy Document Number: 42-N, 42-NPT, 42-FLG