OWNER S MANUAL SINGLE STAGE STAINLESS STEEL CENTRIFUGAL PUMPS SSS SERIES. Installation / Operation / Troubleshooting SSS702 SSS2102 SSS2103 SSS3703

Similar documents
OWNER`S MANUAL SMH RANGE HORIZONTAL MULTISTAGE CENTRIFUGAL PUMPS SMH35 SMH45 SMH55 SMH75 SMH90

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

OWNER S MANUAL. Horizontal Multistage Centrifugal Pumps. SMH Range

Pantera Cartridge Filter II PCF-II

FARMMASTER. JJ & OJ Series

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

OWNER S MANUAL. Jet Assisted Pumps Series

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation.

OWNER`S MANUAL BLAZEMASTER. B & BM Series. Engine Drive Pumps for Fire Fighting & Water Transfer

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

OWNER`S MANUAL. Quiptron Skimmers. Models

Owners Manual: - Pumps

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

OWNER S MANUAL LCT65VR ENGINE DRIVE TRANSFER PUMP. For the installation, operation and service of

OWNER S MANUAL. Dominator Submersible Pump. For the Installation, Operation and Service of

OWNERS MANUAL. enviromax. Variable Speed Pool Pump. For the Installation, Operation and Service of the

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL. Pantera Series II. High Rate Sand Filter

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE PUMP HSE RANGE

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

Installation and Operating Instructions for

OPERATION & MAINTENANCE INSTRUCTIONS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE PUMP HSE RANGE

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

June14. Type

Installation and Operating Instructions

PRESSURE BOOSTER 150

INSTALLATION AND OPERATING INSTRUCTIONS. EXP Hurlcon Pumps CTX Series & BX Series. Bolero ND Cleaner

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

SUBMERSIBLE WATER PUMP

SUNC3000 / Item #40885

6 Litre Oil-Less Air Compressor

Domestic Water Supply Pressure Pumps

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Matala. VersiFlow Series. Instruction and Maintenance Manual

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

SUBMERSIBLE WATER PUMP

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

INSTALLATION AND OPERATING INSTRUCTIONS

HALLMARK INDUSTRIES INC

POND PUMP Model Nos:SPP3 & SPP6 0200

MP V 8A Electronic Smart Charger. Instruction and Information Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

1 ELECTRIC WATER PUMP

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

TPHK Series Immersible Pump

GARDEN HOSE UTILITY PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Sump Pump. Installation and Operating Instructions

Submersible Pump Instructions. Safety Instructions

Instruction Manual. * We reserve the right to amend specification without prior notice.

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

StormPro BA Series Sump Pump

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. Maximum Operating Pressure 510 bar

TPAK Series COOLANT PUMP

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

SUBMERSIBLE WATER PUMP

MODEL P INSTALLATION INSTRUCTIONS

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

INSTALLATION AND OPERATING INSTRUCTIONS

12V CONSTANT PRESSURE PUMP

GeyserMax-Flow Series

SELF PRIMING CHEMICAL SERVICE PUMPS

CONSTANT PRESSURE PUMP

ELECTRIC LIFTING HOIST

SHALLOW WELL JET PUMP

HM Series Electric Pumps

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

2.0Ah BATTERY INSTRUCTION MANUAL

ESE Series Cast Iron Sewage Pumps

Installation & Operating Manual

Installation & Operating Manual

Vertical Chemical Pumps

INSTALLATION AND OPERATING INSTRUCTIONS

STAR STOP SHALLOW WELL JET PUMP

Installation & Operating Manual

1600 PSI ELECTRIC PRESSURE WASHER

Owner s Manual Drill and Light Weight Portable Utility Pumps

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Installation and Operating Instructions for Davey HP/T & HS/T Pressure Systems with

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

VERSION 2017 V.1.0

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

MINIPOND 700/900 Mk2 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

Submersible Tank Pump

LAWN SPRINKLER, IRRIGATION PUMP

Transcription:

OWNER S MANUAL SINGLE STAGE STAINLESS STEEL CENTRIFUGAL PUMPS SSS SERIES SSS702 SSS2102 SSS2103 SSS3703 Installation / Operation / Troubleshooting We recommend, for additional protection, the pump to be supplied from socket outlet protected by a residual current de vice RCD (also known as an Earth Leakage Circuit Breaker ELCB) with a maximum rated residual current of 30mA. Should you the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of this product.

Relax - you ve bought an... ONGA Congratulations on your decision to purchase an Onga product. Onga is one of the best know brands in its field, with a proud local and international reputation. Onga is a brand for reliability, value for money and technological innovation. You will find Onga product wherever people need to move water in 3 broad markets covering: Technologically advanced solutions for moving and treating water in the Home, Garden and Pool. Residential Innovative Stock and Crop water management solutions for Primary Industries. Agricultural Water movement products for Building services, Emergency services and Original equipment Manufacturers. Process page 2

1.Continual Product Improvement We employ the best engineers both in Australia and around the world to develop new and better ways to take water further. 2. Operational E x c ellence There is only one standard that we set ourselves for both product quality and the quality of our service. That standard is excellence... to have noone better than us at what we do... nothing short of that is acceptable. Our commitment to quality is reinforced with our ISO 9001 accreditation. 3. A Fair Price Onga products are neither the cheapest nor the most expensive in their field. Our products do, on the other hand, always represent very good value for money; they always have and they always will. 4. Our Team of Dealers The hand picked authorised Onga dealer network throughout Australia and worldwide are second to none. We invest considerable time and resources training and supporting them through the Onga Training Academy. page 3

Table of contents Dimensions...page 4 Model data / performance... page 5 Application...page 6 Installation...page 7-11 Operation...page 12-13 Service & Maintenance... page 14 Troubleshooting...page 15 Dimensions Model Ports DN1 DN2 L (mm) W (mm) H (mm) L1 (mm) L2 (mm) W1 (mm) H1 (mm) SSS702 1¼ 1 332 210 224 119 55 149 110 SSS2102 1½ 1¼ 440 210 250 129 55 149 110 SSS2103 1½ 1¼ 440 210 250 129 55 149 110 SSS3703 2 1¼ 440 210 250 129 55 149 110 page 4

Model data Technical information Model Inlet (suction) Outlet (discharge) Water Temp Range IP Rating Electrical Supply Phase Max Ambient Temp Motor (kw) SSS702 1 ¼ 1 0 C - 85 C IPX4 230V 50Hz Single 55 C 0.55 SSS2102 1 ½ 1 ¼ 0 C - 85 C IPX4 230V 50Hz Single 55 C 1.1 SSS2103 1 ½ 1 ¼ 0 C - 85 C IPX4 230V 50Hz Single 55 C 1.5 SSS3703 2 1 ¼ 0 C - 85 C IPX4 230V 50Hz Single 55 C 2.2 Performance page 5

Application Onga SSS Series pumps are suitable for pumping clean water in agricultural, horticulture, vat washing, irrigation and light commercial. The all stainless steel construction make it ideally suited for most potable water pumping applications providing longevity and corrosion resitance. page 6

Installation The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class 1, IP4X rated products. These instructions are a guide only. Users not familiar with pumping equipment should seek advice from people experienced in pump equipment and installation. Freezing conditions will damage the unit, because when water freezes it expands. Ensure that the pump is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions. SSS pumps are electrically connected. Ensure that they are switched off and unplugged from socket outlet during installation and any subsequent service work. The pump is designed to be used with clean water. Do not use it with alternative fluids, abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive environment or near combustible matter. Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. Automatic thermal overload cut-out protects the motor for heat damage during operation and it will restart without notice when the motor cools down. The pump is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the pump. Read the following instructions in this owner s manual when installing and operating equipment. page 7

Installation (continued) 1. Preparation for Installation Inspect your pump for shipping damage. Report any damage to your Onga stockist. Make sure the suction piping is free of air leaks and is laid so that there can be no airlocks. Warranty of these pumps is void unless they are operated in accordance with this owner s manual. 2. Pump Protection The pump should be protected from the weather, floods, chemicals, dust, vermin, insects etc. It is highly recommended that the pump be housed in a weather proof, well vented enclosure. If the pump is not adequately housed the warranty may be deemed void. 3. Pipe Installation Pumps can be damaged if care is not taken when connecting pipes. Pipes should be supported so that the pump casing is not strained by the weight or misalignment. We recommend the pump and pipe are coupled using flexible type polythene pipe, rubber hose or a multi-directional barrel union. This union coupling can also be used to remove the pump for service should it be necessary without having to cut pipes. Pipe fittings should be carefully screwed onto the pump making sure not to cross-thread or overtighten. We recommend the use of a barrel union to connect to the pump as this avoids possible damage to the pump threads and unnecessary replacement of parts. For best results use teflon tape to seal the joint. Satisfactory sealing can be achieved by hand tightening fittings ensuring that no leaks are evident once under pumping pressure. 4. Locating the Pump Find a location for your pump as close to your water source as possible. Ensure that this location is on a seperate footing from your home. To do this you can mount the pump on a concrete tile or concrete base. 5. Power Source Arrange for an electrician to install an outdoor 10AMP (models up to and including 1.5KW) GPO electrical outlet near the pump if there is not one there already. Or a 15AMP plug from models 2.2KW and above. page 8

Installation (continued) 6. Suction This is the most important part of the installation as errors will cause signifi cant problems for the system in performance and longevity. IMPORTANT: A gate valve must be installed at the tank outlets. 7 3 4 3 2 1 5 6 Correct installation 1. Foot valve 2. Inlet pipe 3. Tie-in 4. Filling plug 5. Draining plug 6. Electric pump 7. Valve Incorrect installation B1 B2 Installation precautions 1. While installing the electric pump, do not use soft rubber tube for the inlet pipeline, avoid it being sucked flat. 2. The foot valve should be vertically placed and installed 30cm from wa ter bottom to avoid sucking in sands and stones (B2); 3. Joints in the suction pipe should be well sealed with the minimal amounts of elbows used. 4. Diameter of the suction pipe should be at least the same size as the water inlet, so as to avoid too much water loss which will influence outlet performance. 5. Pay attention to the drop of water level while using, the foot valve should not be above the water surface (B1). 6. In case the suction pipe is longer than 10m or its lifting height exceeds 4m, the pipe diameter should exceed diameter of water inlet of the pump. 7. Ensure the pump will not be affected by pipeline pressures while installing the pipelines. 8. A Y Strainer should be installed in inlet pipelines so as to avoid solid parti cles to enter into the electric pump. page 9

Installation (continued) To maintain optimum performance from your pump, the suction pipe should be: - Kept to the shortest distance practical, but not shorter than the recommended length. - Re-enforced crush resistant (non-collapsable) hose or pipe. - All fittings should be air tight. - Pipes should be equal to or larger than the diameter of the suction/inlet port. - Ensure that the suction is completely submerged. In-line strainers/filters are only recommended for pumps fitted with Minipress, PressControl or WaterSwitch. Regular maintenance is required to keep them clean and provide maximum pump pressure. Consult your Onga dealer for information regarding the suitability of each SSS pump in an automatic pressure system prior to installation. 7. Discharge The length and diameter of the discharge hoses/pipes will affect the pressure and flow rate at which your pump operates. Pressure ratings of all components must exceed the maximum pressure of the pump by an appropriate safety factor. All pipework should be supported independently of the pump. 8. Pump Priming Ensure that there is at least 200mm of water in your tank, (i.e. that the tank outlet is covered, and the pump will not draw any air into the system). Open the gate valve on the tank. Check for any leaks, and repair these if necessary. If no leaks are present, remove the priming plug to open the priming port on the top of the pump case. If the tank is above the level of the pump, water will start to run out of this port. Replace the priming plug carefully. Your pump is now ready to run. (Note: If a check valve is installed in the suction line, water may not fill the pump. If this occurs, follow the instructions below). If the tank water level is below the level of the pump, you will need to fill the pump body and suction line. Remove the priming plug and fill the pump body and suction line using a funnel. 9. Electrical The pump is supplied with a interconnection appliance coupler and standard Australian 10AMP or 15AMP plug and cord. 15amp plug and cord for SSS3703 (2.2KW model) Connection to the power supply is a matter of inserting the plug into the suitable socket outlet. page 10

Installation (continued) The socket outlet shall be in a dry and flood free location; preferably do not use extension cords for this very reason and because they can cause voltage drop. Supply voltage outside limits specified in Model Data can cause the motor to overheat leading to overload tripping, reduced component life or seriously damage pump and voids warranty. We recommend, for additional protection, the pump to be supplied from socket outlet protected by a residual current device RCD (also known as an Earth Leakage Circuit breaker ELCB) with a maximum rated residual current of 30mA. page 11

Operation The pump operator or owner must be provided with this owner s manual. This must be read before operation, and followed during operation. Ensure that your pump is filled with water before operating. The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive enviroment or near combustible matter. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. Automatic thermal overload cut-out protects the motor for heat damage during operation and it will restart without notice when the motor cools down. Do not dismount the pump body unless water in the pump chamber is empty. page 12

Operation (start-up) Rotate the fan blade before startup, check whether the pump rotation is flexible and then unscrew the water-filling plug, fill the pump chamber with clean water from the water injection hole, then tighten the plug screw after air has been completely discharged. The valve should be shut tightly while starting up the pump. After the pump discharges water and operates normally, adjust the valve to the required flow (flow and lift will be displayed on the nameplate). Attention: 1. In case no water is discharged after being started for more than 5 minutes with water filled, turn off the electric pump, re-fill water or check whether the inlet pipeline has leakages. 2. In case of any frost and ice damages, please open the drain plug to emptywater in the pump chamber. When start up the pump again, open the drain plug, fill water and tighten it and then the pump is usable. 3. In case not use for a long time, water in the pump should be emptied. The pump body, impeller and support should be cleaned and coated with anticorrosive oil before they are put in a ventilated and dry place for use. 4. In case the pump is halted for a long time, start it up again according to above diagram. 5. In summer or when the ambient temperature is high, pay attention to ventilation, avoid dew on electrical parts which will result in electrical faults. 6. In case the motor is hot or abnormal, cut off the power immediately and check faults according to the troubleshooting table on page 15. page 13

Service and Maintenance Pump should be serviced only by qualified personel. For best results, use only genuine service parts. Be sure to prime pump before starting. To avoid dangerous or fatal electrical shock, turn OFF power to pump and remove plug from outlet before attending the pump. RCD tripping indicates an electrical problem. If RCD trips and will not reset have a qualified electrician inspect and repair electrical system and/or pump. If service is required to the power supply cord and/or appliance connectors, they must be replaced with the specialised cord assemblies by Pentair service agent or similarly qualified personnel in order to avoid a hazard. Water may be HOT, release pressure with care before servicing. General care and maintenance Under normal conditions the Onga SSS series of pumps require only minimal attention. In order to prevent possible failures, it is advisable to periodically check the pressure supplied and power absorption. A decrease in pressure is a symptom of wear. An increase current absorpion is a sign of abnormal mechanical function in the pump and/or motor. page 14

Troubleshooting Symptom Cause Remedy The motor can not be started The motor is in operation, but no water is discharged Insufficient pressure Motor works intermittently or the stator winding is burned out leakage of mechanical seal Abnormal noise from the pump Single-phase power supply (3 phase electric motor): a. poor connection of the power switch; b. fuse is burned out; c. loose power lead; d. phase failure of the cable. Capacitor is burned out. The rotating shaft and bearing are jammed. Impeller is jammed. Stator winding is damaged. Incorrect direction of pump rotation. The pump is not fully filled with water. The impeller is damaged. Leakage of the suction pipe. Water level is too low. Freeze caused by accumulated water in the pipeline or the chamber. Incorrect pump type. The inlet pipeline is too long or with too many bends, pipe diameter is not selected as required. Inlet pipeline, filter screen or pump chamber is blocked by foreign materials. The impeller is jammed or unde overload operation for a long time. Incorrect grounding, broken cable or the electric pump is hit by lightning. The mechanical seal is worn and torn by impurities. Noise from the bearing. Impeller is jammed. Excessive flow. page 15 a. repair switch contact or replace the switch; b. replace the safety fuse; c. check and tighten the power connector; d. repair or replace cables. Replace with a same type capacitor (send to the maintenance point for repair). Replace the bearing (send to the maintenance point for repair). Turn rotating shaft of the fan blade terminal with screw driver to let it rotate flexibly or demount the pump body to clear foreign materials. Replace winding coils (send to the maintenance point for repair). Invert two-phase wirings of the motor (three-phase motor). Re-fill the pump with water. Replace the impeller (send to the maintenance point for repair). Check sealing of various joints of the inlet pipelines. Adjust installation height of the pump. Start up the pump after ice is melted. Select suitable pump. Apply the pipe with the stipulated diameter, and make the inlet pipe short. Clean pipeline, foot valve or pump chamber, clean foreign materials. Clean foreign materials in the pump chamber; operate the pump under the rated flow. Correct grounding, or replace broken cable, or replace winding coils. Clear or replace the mechanical seal. Replace with the same type bearing. Remove foreign materials. Adjust to the range displayed on the nameplate before use.

IMPORTANT............ Head Office Pentair AU/NZ: 1-21 Monash Drive, Dandenong South, VIC 3175 Australia National customer service: Phone :1300 137 344 Fax :1800 006 688 National dealer locator: Phone :1800 664 266 Email: Web: au.sales@pentair.com www.pentair.com.au New Zealand National customer service: Phone :0800 654 112 Fax :0800 806 642 National dealer locator: Phone :0800 664 269 Email: Web: nz.sales@pentair.com www.pentair.co.nz International Australia/New Zealand Phone :+61 3 9709 5800 Fax :+61 3 9709 5888 Information contained here-in remains the property of Pentair Australia Pty Ltd. Any reproduction, display, publication, modification or distribution is strictly prohibited without the prior written permission of Pentair Australia Pty Ltd. Disclaimer: Every endeavour has been made to publish the correct details in this owner`s manual. No responsibility will be taken for errors, omissions or changes in product descriptions, specifications. Pentair Australia reserves the right to change specifications. L100237 A 0414