INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

Similar documents
SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

2965 Magnetic Shear Lock Installation Instructions

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

Security Door Controls

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

SECURITY DOOR CONTROLS

INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH

EZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit

EMLock 1500 Series. MEA Listed. New Modular Kits. Online System Wizard and Project Manager at

EMLock 1500 Series. MEA Listed

Installation Instructions

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS

EMLock Magnetic Locks

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Locking Devices. Electromagnetic Locks. Security Door Controls 8 SECURITY DOOR CONTROLS

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

Model 2300DL Installation Guide

INSTALLATION 8310/8320

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

HANDLING MECHANICAL INSTALLATION

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

EMLock Magnetic Locks

Model 2300JL Installation Guide

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

Electro-Mechanical Swing Operator. Table of Contents

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

M670/M680BD MAGNALOCK SERIES Installation Instructions

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.

SHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS

Premium Dry Freight (Plywood) Door Installation REFERENCE FIGURE 1

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

Package Contents. Mounting Hardware

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

PFadvantage MF 6850/6855; Ideal 9080/9090

Accessories 286 SDC SECURITY DOOR CONTROLS

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

M400 Series Double Locks. Features

Pre-Installation Instructions

INSTALLATION DESCRIPTION

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

MODEL 1200S MAGNETIC LOCK

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

Tooling Assistance Center

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

Motorized Electric Latch Retraction

TS93 EMF T/PT/TDE. Surface applied door closer

INSTALLATION INSTRUCTIONS CRL ESK2/ESP2

Electromagnetic Locks DORMA EML

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

Excel Series Value Engineered Access Hardware

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

MagForce+ The Positive Force in Electromagnetic Locks

MOUNTING INSTRUCTIONS FOR TJ1000 SERIES INSWINGING DOORS ******READ THOROUGHLY BEFORE INSTALLING******

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electromagnetic locks - Single Doors

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

Electromagnetic Door Holder/Releases

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

MODEL 1200S MAGNETIC LOCK

AA4006 Speed Sensitive Trip Unit. User Manual

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

PFadvantage JD 3300/4400/6600/7700; 4420

Plasma Display Electric Ceiling Lifts

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

Headers - 4-1/8, 4-1/2, 6. with PT21 and Shear lock for single or double doors. Installation instructions

Price List 18.4 PRICES VALID STARTING FEBRUARY 1ST, The Lock Behind Your System. Electric & Mechanical Access Control Hardware

Drop Feeder Control. Part Number Introduction. Setting the Control. Time Clock operation. Manual Operation

92-00 Civic/ Integra/ Del Sol/ Accord/ CRX

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Price List 18.4 PRICES VALID STARTING FEBRUARY 1ST, The Lock Behind Your System. Electric & Mechanical Access Control Hardware

Price List 19 PRICES VALID STARTING JANUARY 14, The Lock Behind Your System. Electric & Mechanical Access Control Hardware

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

Installation Instructions Series 78-B/FHA Hold Open

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS

V2M1200/1290 Series Maglock Installation Instructions

1PC TONNEAU COVER INSTALLATION INSTRUCTIONS IMPORTANT

Sivoia QS Wireless Drapery Lite System

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

RECESSED MAGNALOCK MODEL M34R SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Universal Storage - Storage/Wardrobe/Combo Cabinets/Lateral Files

!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

VOLKSWAGEN AMAROK 3 PIECE HARD TONNEAU COVER INSTALLATION INSTRUCTIONS

Transcription:

SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS. REFER TO THE PROPER TEMPLATE ACCORDING TO THE TYPE OF DOOR AND FRAME APPLICATION. READ THESE INSTRUCTIONS AND STUDY THE TEMPLATE THOROUGHLY BEFORE BEGINNING THE INSTALLATION. IMPORTANT NOTES: Although electromagnetic shear locks provide the utmost in aesthetics for fail-safe applications, they are less forgiving than electric bolt locks and direct pull magnetic locks where alignment problems exist. Therefore, great care must be taken during preparation and installation of the frame, door hardware and the shear Emlock to attain proper alignment and ensure positive lock operation. Unbalanced air conditioning (stack pressure) can hinder door alignment and must be corrected to help ensure positive locking. Use only the highest quality door closer. POSITIVE CENTERING DOOR CLOSERS ONLY should be used on double acting doors to help attain consistent dead center alignment. Door latching problems must be corrected prior to installation. The maximum locking strength of the 1561/1562 Hi/Shear Emlock is 2000 lbs. INSTALLATION: 1. Make sure the clearance between the door top rail and frame header is 1/8. Make adjustments to the door as required. 2. Adjust single acting door and door closer to ensure the door settles immediately and is fully closed and at rest against the stop allowing for mutes, smoke seals or weather stripping where applicable. Adjust double acting door and POSITIVE CENTERING DOOR CLOSER to ensure the door settles immediately and is fully closed and at rest in the dead center of the frame. 3. Locate the vertical centerline of the Emlock and armature as close as possible to the leading door edge. CAUTION: Wood door applications require the armature back box to be located and ample distance from the door edge vertical grains, to avoid splitting from wood screws. 4. Determine the horizontal centerline of the door top rail thickness. The armature centerline will be the same. Mark the door per the template. 5. Before determining the frame header centerline, single acting doors must be fully closed and at rest against the stop allowing for mutes, smoke or weather stripping where applicable. Double acting doors must be fully closed and at rest in the dead center of the frame. 6. Mark the frame header per the template. 7. Prepare the door and frame per the template. 8. An auto relock time delay (built-in with 1561) is recommended for all installations to delay relocking 1 to 6 seconds after initial door closure. This will help ensure the door is fully closed and at rest to obtain optimum alignment before the Emlock is energized. Consult Figure 7A or 7B according to material supplied. With the power off, make all wire connections to a properly fused power source. P:\INSTALLATION INST\ELECTROMAGNETIOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV D 03-08 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

9. When installing 1562 model use Figure 7B, make the timer adjustment as required and test the TDA time delay prior to mounting in the frame. The TDA timer is field adjustable for 1 to 6 seconds and is factory set at approximately 3 seconds. turn clockwise to increase and counter clockwise to decrease the delay time. 10. Install the Emlock and armature with the auto relock switch assembly towards the leading edge of the door. The 1561 timer adjustment can be made after the Emlock is installed through the small hole in the face of the magnet. Using a small flat blade screwdriver, turn clockwise to increase time, counter clockwise to decrease time. 11. For proper operation, the armature must be adjusted upward as close as possible and parallel to the Emlock without interfering with opening and closing of the door. Proper operation cannot be expected with more than 1/8 clearance between the armature and the Emlock. If you find the clearance to be more than 1/8, shim the assembly with the shims provided. 12. With the door closed, turn the lock power on. Check the lateral alignment. The armature shear stops should be centered between each pair of magnet shear stops. 13. If the clearance between the shear stops is sufficient, open and close the door a few times to ensure the Emlock will lock and unlock positively. 14. Adjust the auto relock switch magnet to avoid early activation and help ensure positive locking on door closure. Adjust inward to delay Emlock activation. Do not adjust higher than the armature rest position. 15. If the shear stops are too close or binding, double check the templating and door alignment, and make corrections as required. 16. If positive locking cannot be attained due to misalignment after the previous adjustments, the armature shear stops can be reversed with the wide clearance shear stops. CAUTION: The use of armature offset shear stops may correct misalignment but should not be used when proper door latching is inhibited. 17. Repeat steps 11 through 15 as necessary following shear stop replacement. 18. Cycle the door and Emlock several times after the completion of installation. MODEL # LOCK DIMENSION L W D HOLDING FORCE POWER CONSUPTION 12VDC 24VDC MODEL # ARMATURE DIMENSION L W D 1561 8" 1-1/2 2000 650mA 350mA ITCM 8-7/16" 1-1/2 1562 8" 1-1/2 1-1/4 2000 650mA 350mA FTCM 8-7/16" 1-1/2 HTCM 8-7/16" 1-1/2 P:\INSTALLATION INST\ELECTROMAGNETIOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV D 03-08 Page 2

FIGURE 1 LEADING EDGE OF DOOR MPM MIDPOINT IDENTIFICATION MPM MIDPOINT MAGNET MIDPOINT ARMATURE THE MOST IMPORTANT ELEMENTS FOR THE PROPER INSTALLATION OF THE HI/SHEAR MAGNET ASSEMBLY ARE THAT THE MIDPOINT OF THE ARMATURE AND THE MIDPOINT OF THE MAGNET MUST LINE UP EXACTLY. ALL CENTERLINES OF THE ARMATURE MUST LINE UP WITH THE RESPECTIVE CENTERLINES OF THE MAGNET FIGURE 2 3/4 REINFORCEMENT TAB SDC PART # 006-007-10 7-15/16 8-7/16 7/16 1-1/2 4-9/32 4-9/32 4-23/32 4-23/32 CAPPED TOP DOOR HOLLOW METAL DOOR TEMPLATE 8 HOLES 3/16 DIA 5/16 x 82 DEG CSK FOR #8-32 SCREWS FIGURE 3 To 1-1/8 DOOR 31/32 4 HOLES #1/4-20 UNC-2B 2-11/32 1/2 DIA 2 PLCS 1-3/4 3/4 3/8.450 31/32 5/16 DIA HOLE 2-11/32 2-21/64 METAL DOOR TEMPLATE " TO 1-1/8" DEPTH CHANNEL P:\INSTALLATION INST\ELECTROMAGNETIOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV D 03-08 Page 3

FIGURE 4 METAL FRAME TEMPLATE 7/16 4-7/16 1-9/16 10-1/2 4-7/16 MPM 4.0" 7/16 OF MAGNET REINFORCEMENT TAB 8.0" SDC PART# 006-007-10 3/4 1/8 A 25/32 OF MAGNET 8 HOLES 3/16 DIA CSK 5/16 x 82 DEG 1-1/16 FOR 1561 REINFORCEMENT TAB REVERSED FOR HOLLOW METAL FRAME DETAIL A 16 GAUGE 1/4 to 3/4 SHIM IN 1/8" INCREMENTS AS REQUIRED SDC PART# 006-001-14 1-3/4 7/16 4 HOLES #8-32 UNF-2B 7-15/16 3-31/32 3-31/32 1-1/2 3-7/16 3-7/16 6- DOOR 1/8 1-1/16 FOR 1561 METAL DOOR TEMPLATE 1/4 TO 3/4 CHANNEL DEPTH FIGURE 5 1-15/16 1.0 DOOR SHIM REQUIRED OPTIONAL SDC PART# 006-001-11 31/32 2-11/32 2-11/32 31/32 1-3/4 3/8 3/4 1-1/4 5/8 5/8 SHIM, SDC PART # 006-001-11 HERCULITE DOOR TEMPLATE FIGURE 6 1-1/16 5/32 4X #10 x 1-1/2 WOOD SCREWS 4 HOLES FOR #10 x 1-1/2 WOOD SCREWS 2X 1/2 DIA 5/16 DIA OPTIONAL DOOR REINFORCEMENT HOUSING SDC PART # WDRBM 1-1/2 29/64 1/2 2-21/64 3-17/32 3-17/32 3-31/32 3-31/32 4-9/32 4-9/32 WOOD DOOR TEMPLATE P:\INSTALLATION INST\ELECTROMAGNETIOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV D 03-08 Page 4

FIGURE 7 Figure A LOCK Model 1561 With built in Auto Relock Switch Auto Relock Delay Timer red/blk wht/blk ACCESS CONTROL + - To Fused 12V or 24V DC Power Source DPS OPTION YEL = N/O GRY = COM ORG = N/C BAS OPTION WHT = N/O BLK = COM RED = N/C Figure B red/blk ACCESS CONTROL LOCK TDA Model 1562 With built in Auto Relock Switch and Auxiliary Auto Relock Delay Timer Board wht/blk - + To Fused 12V or 24V DC Power Source FIGURE 8 Please note the drawing in Fig. 1. It show two different alignments off center of the shear tab. wide For normal single acting door alignment see Fig. 2..343.312 For double acting doors see Fig. 6..312 Fig. 2 Fig. 5 006-001-04.312 For slightly warped single acting doors see Fig. 4. This also works well for quick release, when switch bars are used. Fig. 1 Fig. 4 Fig. 7 006-001-04 The offset shear tab cannot be used on shear locks with bond sensors. Fig 5 & 7. wide Fig. 3 Offset shear tabs ARMATURE TOP VIEW ARMATURE SHEAR TAB INSTALLATION Fig. 6 006-001-04 Even shear tabs ARMATURE TOP VIEW For locks with bond sensor P:\INSTALLATION INST\ELECTROMAGNETIOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV D 03-08 Page 5

MAINTENANCE INSTRUCTIONS The electromagnet and the armature should be handled carefully. Any damage to the surface such as paint, burrs, dirt and rust may hinder bonding of the surface and reduce holding power. IF THE SURFACE PLATING BECOMES DAMAGED 1. Do not touch lock face with your hands. 2. Use a soft clean dry cloth or abrasive cloth (i.e., Scotch-Brite by 3M) to clean the lock face. Do not use sand paper. 3. A rust inhibitor, such as M1 manufactured by Starret, or LPS3 manufactured by LPS Laboratories (available in most hardware stores) can then be applied to the lock face. 4. Apply a coat of rust inhibitor to the armature face also. P:\INSTALLATION INST\ELECTROMAGNETIOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV D 03-08 Page 6