IAQ-CALC TM Indoor Air Quality Meter

Similar documents
IAQ-CALC TM Indoor Air Quality Meter

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Indoor Air Quality Meter

DP-CALC TM Micromanometer

VELOCICALC Air Velocity Meter

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

Rotating Vane Anemometer

Model 8345/8346/8347/8347A VELOCICALC Air Velocity Meters

Rotating Vane Anemometer

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Thermo-Anenometer Model Owner s Manual

PRIMARY CALIBRATORS MODEL 4046/4146

Model 8026 Particle Generator

Model 8026 Particle Generator

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

EXHAUST FAN FLOW METER

ANALOG BALANCING TOOL MODELS ABT701, ABT703, ABT711, ABT713

AXD 530 MicroManometer

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

This manual covers the following model:

HIGH VOLTAGE DIGITAL AMMETER

Infrared Thermocouple Probe

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

CALIBRATION TEST FIXTURES

Coating Thickness Gauges

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

User's Guide. CO 2 Meter. Model CO250

SPC Series. Digital Scale. Operation Manual

TABLE OF CONTENTS 11.0 WARRANTY

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

AXD 510 MicroManometer

Humidity Monitor model 00619

EAGL 1-Touch Laser Level

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

OPERATING INSTRUCTIONS AND PARTS LIST

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA


"WHERE TUBING AND FITTINGS COME TOGETHER"

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Table of Contents Up and Running... 1 Measurements... 2 Keypad Operation... 4 Displayed Items... 4 Placement for Monitoring/Testing...

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

FR1118- P10. User s Manual

Thermometer model 00826

SINGLE STICK DIGITAL VOLTMETER

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

Thermometer models / 00831A

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

Operators Manual. Qualstik PLUS. Live-Line Power Quality Survey Meter. SensorLink

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

MoistureMatch A next generation grain tester

User's Manual. Earth Ground Resistance Tester. Model Introduction

Wireless Thermometer model 00380

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Digital Resistivity Meter. Part No Instruction Manual. Updated 09/01/2015 Ver. 3.0

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Hydronic Manometers. Hydronic Manometer. Model HM680. Owner s Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Tension your belts at the speed of light!

Thermometer models 02023/02028/02053/02054

SUNTURA SOLAR TRACKER

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Installation Guide. Marine Filter SURT023M SURT024M

Window Thermometer models / / 00423

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Wireless Thermometer model 00782W

ACCUBALANCE Air Capture Hood Model 8371

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

DT304. Digital Temperature Logger INSTRUCTION MANUAL

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

SUNTURA HD SOLAR TRACKER

AUTORANGING RESISTANCE INDICATOR

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

Broadband PowerShield. CP27U Models. User Manual

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

MODEL V-24 OWNER'S MANUAL PARTS

CO95. Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH Fax: (503)

Charging with AC (wall) Charger

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Buck BioAire Model B520 Instruction Manual

SIDESLIDE SERIES C-CLAMP 940K-010FI BOLT 940K-010RSC PICATINNY 940K-010PIC PRODUCT MANUAL

Transcription:

ENERGY AND COMFORT Indoor Air Quality IAQ-CALC TM Indoor Air Quality Meter Model 7515 Operation and Service Manual

Copyright TSI Incorporated / May 2007 / All rights reserved. LIMITATION OF WARRANTY AND LIABILITY (effective July 2000) Seller warrants the goods sold hereunder, under normal use and service as described in the operator's manual, shall be free from defects in workmanship and material for twenty-four (24) months, or the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment. b. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment. c. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies. d. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller. The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss. Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems.

CONTENTS CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION...1 CHAPTER 2 SETTING-UP...3 Supplying Power to the Model 7515...3 Installing the Batteries...3 Using the Integral Probe...3 CHAPTER 3 OPERATION...5 Keypad Functions...5 CHAPTER 4 MAINTENANCE...7 Recalibration...7 Cases...7 Storage...7 CHAPTER 5 TROUBLESHOOTING...9 APPENDIX A SPECIFICATIONS...11 iii

Chapter 1 Unpacking and Parts Identification Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components below. If anything is missing or damaged, notify TSI immediately. 1. Carrying case 2. Instrument 3. Calibration collar 1

Chapter 2 Setting-up Supplying Power to the Model 7515 IAQ-CALC Indoor Air Quality Meter The Model 7515 is powered with four size AA batteries. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Model 7515 is designed to operate with either alkaline or NiMH rechargeable batteries, although it will not recharge NiMH batteries. Battery life will be shorter if NiMH batteries are used. Carbon-zinc batteries are not recommended because of the danger of battery acid leakage. Using the Integral Probe The sensing probe relies on the diffusion of air. For best results, try to keep the sensing probe surrounded by moving air. Do not breathe on the probe. Humans exhale CO 2 levels exceeding 10,000 ppm and it may take time for the probe to re-stabilize. 3

Chapter 3 Operation Keypad Functions ON/OFF Key Sample Key Stats Key CAL Key Press to turn the Model 7515 on and off. During the power up sequence the display will show the following: Model Number, Serial Number, Software Revision, and Last Date Calibrated. Press and release to start the sample, then press the END key to stop the sample. Press to view the minimum, maximum and average of the last sample taken. Press to begin the field-calibration process. To recalibrate in the field, first connect zero gas to the instrument and open the regulator. Then use the and ENTER keys to select ZERO. The instrument will automatically make zero itself after one minute. After zeroing the sensor, connect span gas to the instrument and open the regulator. Then use the and ENTER keys to select SPAN. The instrument will take one minute to make a reading. Then use the and ENTER keys to adjust the concentration displayed on the instrument to match the concentration on the gas cylinder. 5

Chapter 4 Maintenance The Model 7515 requires very little maintenance to keep it performing well. Recalibration To maintain a high degree of accuracy in your measurements, we recommend that you return your Model 7515 to TSI for annual recalibration. Please contact one of TSI s offices or your local distributor to make service arrangements and to receive a Return Material Authorization (RMA) number. The Model 7515 can also be recalibrated in the field using the CALIBRATION menu. These field adjustments are intended to make minor changes in calibration to match a user's calibration standards. The field adjustment is NOT intended as a complete calibration capability. For complete, multiple-point calibration and certification, the instrument must be returned to the factory. Cases If the instrument case or storage case needs cleaning, wipe it off with a soft cloth and isopropyl alcohol or a mild detergent. Never immerse the Model 7515. If the enclosure of the Model 7515, it must be replaced immediately to prevent access to hazardous voltage. Storage Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage. 7

Chapter 5 Troubleshooting Table 5-1 lists the symptoms, possible causes, and recommended solutions for common problems encountered with the Model 7515. If your symptom is not listed, or if none of the solutions solves your problem, please contact TSI. Table 5-1: Troubleshooting the Model 7515 Symptom Possible Causes Corrective Action No Display Unit not turned on Switch unit on. Low or dead batteries Replace batteries. Dirty battery contacts Clean the battery contacts. High CO 2 levels Breathing on probe Shield probe from breath and allow instrument to re-stabilize. Instrument Error message appears Fault in instrument Factory service required on instrument. WARNING! Remove the probe from excessive temperature immediately: excessive heat can damage the sensor. Operating temperature limits can be found in Appendix A, Specifications. 9

Appendix A Specifications Specifications are subject to change without notice. CO 2 : Range: 0 to 5000 ppm Accuracy 1 : ±3% of reading or ±50 ppm, whichever is greater Resolution: 1 ppm Sensor type: Non-Dispersive Infrared (NDIR) Instrument Temperature Range: Operating (Electronics): 40 to 113 F (5 to 45 C) Storage: -4 to 140 F (-20 to 60 C) Instrument Operating Conditions: Altitude up to 4000 meters Relative humidity up to 80% RH, non-condensing Pollution degree 1 in accordance with IEC 664 Transient over voltage category II External Meter Dimensions: 3.3 in. 9.6 in. 1.8 in. (8.4 cm 24.4 cm 4.4 cm) Meter Weight: Weight with batteries: 0.6 lbs (0.27 kg) Meter Display Dimensions: Primary display: 4-digit LCD, 0.6 in. (15 mm) digit height Secondary display: 3.5-digit LCD, 0.3 in. (8 mm) digit height Power Requirements: Four AA-size batteries (included) 1 At 77 F (25 C). Add uncertainty of ±0.2%/ F (±0.2%/ C) away from calibrated temperature 11

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.