flame Retardant overall screened Instrumentation cables (Multicore)

Similar documents
Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Caledonian Flame Retardant RS485 Databus Cables

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

600/1000V, XLPE Insulated Cables according to IEC

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

BS 6724 Armoured Power Cables, 600/1000V

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Power & Control Cable IEC

Caledonian Fire Resistant Optic Fiber Cables

Power & Control Cable IEC

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Any inquiries, please feel free to contact or Caledonian

600/1000V, PVC Insulated Cables according to IEC

FR-3S Fire Resistant Cables

Power & Control Cable IEC

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

LSZH Fire Resistant Cables

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

Power & Control Cables. U o. /U 0.6/1 kv - IEC

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

Power & Control Cables

Telephone Cables Fire Warning Cables

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

POLYCAB WIRES PVT. LTD.

Caledonian Medium Voltage Cables

Electronic Instrumentation

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

The cables you need when you need them

THERMOCOUPLE CABLES THERMOELECTRICITY

POLYCAB WIRES PVT. LTD.

Company Profile. Caledonian Medium Voltage Cables

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

o o blue-brown Fire Performance BS EN BS EN

INSTRUMENTATION CABLE

POLYCAB WIRES PVT. LTD.

Caledonian Medium Voltage Cables

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

Technical Data Sheet Shielded (CY) PVC Control Cable

Data sheet chainflex CF6

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

Data sheet chainflex CF210.UL

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

POLYCAB WIRES PVT. LTD.

Technical Information

BS6724 SWA/LSZH Cable IEC /1000V

N2XY IEC XLPE PVC 0.6/1kV Cable

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

Data sheet chainflex CF140.UL

Data sheet chainflex CFSOFT1

Data sheet chainflex CF8821

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

A NEW BEGINNING IN OIL & GAS. Offshore Cable Range

Cables for Railway Technology

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

MOTOR, SERVO, & FEEDBACK CABLES

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

Global data. Electrical parameters

Data sheet chainflex CF5

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

HIGH TEMPERATURE CABLES

Data sheet chainflex CF240

Building & Infrastructure Cables DELIVERING ENERGY

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Wires & Cables. Next is Ready TM. Marine Cables

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

LOW VOLTAGE c a b l e s

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

Catalogue. Index INDUSTRIAL CABLE

CF270.UL.D.

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Your Partner in Safe Power Solutions. About RESCAB

DKSH provides expertise and solutions to industry

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

ÖLFLEX CLASSIC 110 H Info Benefits

Transcription:

Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer Sheath Tinned Copper Drain Wire PVC Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester Tape Steel Wire Armoured application The PVC versions (Part 1 Type 1&2) are generally use for indoor installation and suitable for wet and damp areas. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services. standards Basic design adapted to BS 5308 Part1 Type 1 & 2 fire PeRfoRMance Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. VolTaGe RaTInG 300/500V cable construction conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 and 5. Insulation: Extruded cross-linked XLPE compound. overall screen: Aluminium/polyester tape with 0.5mm 2 screen (7/0.3mm) tinned copper drain wire. Inner sheath(optional): PVC compound armouring(optional): Galvanised steel wire ADDISON 97

ADDISON Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. COLOUR CODE Insulation Colour: See technical information Outer sheath: Black or blue Physical AND THERMAL PROPERTIES Temperature range during operation: Max.90 C for XLPE 250 C in short-circuit for 5secs max. Minimum bending radius: 8 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable) CONSTRUCTION PARAMETERS No. of Core X Cross Section Conductor RE-2X(St)Y RE-2X(St)YSWAY No./ Diameter of Strands Insulation Thickness Unarmoured Overall Diameter Approx. Weight Diameter Under Armour Armoured Armour Wire Diameter Overall Diameter Approx. Weight mm 2 No./mm mm mm kg/km mm mm mm kg/km 2x0.5 16/0.20 0.6 7.0 50 7.0 0.90 11.4 237 3x0.5 16/0.20 0.6 7.3 59 7.3 0.90 11.7 254 4x0.5 16/0.20 0.6 7.9 69 7.9 0.90 12.3 278 6x0.5 16/0.20 0.6 9.3 94 9.3 0.90 13.9 345 10x0.5 16/0.20 0.6 11.9 147 11.9 0.90 16.7 470 20x0.5 16/0.20 0.6 14.9 253 14.9 1.25 20.6 759 40x0.5 16/0.20 0.6 20.1 444 20.1 1.60 26.7 1229 2x0.75 24/0.20 0.6 7.3 57 7.3 0.90 11.7 251 3x0.75 24/0.20 0.6 7.7 68 7.7 0.90 12.1 272 4x0.75 24/0.20 0.6 8.3 81 8.3 0.90 12.9 310 6x0.75 24/0.20 0.6 9.9 114 9.9 0.90 14.5 379 10x0.75 24/0.20 0.6 12.7 179 12.7 0.90 17.5 522 20x0.75 24/0.20 0.6 16.0 311 16.0 1.25 21.7 858 98 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com 40x0.75 24/0.20 0.6 21.7 555 21.7 1.60 28.5 1420 2x1.5 7/0.53 0.6 8.3 78 8.3 0.90 12.9 300 3x1.5 7/0.53 0.6 8.9 103 8.9 0.90 13.5 345 4x1.5 7/0.53 0.6 9.7 125 9.7 0.90 14.3 377 6x1.5 7/0.53 0.6 11.7 163 11.7 0.90 16.3 490 10x1.5 7/0.53 0.6 14.7 285 14.7 1.25 20.4 773 20x1.5 7/0.53 0.6 18.7 504 18.7 1.60 25.3 1262 40x1.5 7/0.53 0.6 24.6 935 24.6 1.60 31.6 1968 Note : Other conductor sizes & core confi gurations are available upon request. 300/500V Rated Voltage BS 5308 N Standard Flame Retardancy** Reduced Fire Propagation** NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-1-2/EN50265-2-1 IEC60332-3-22/EN50266-2-4 ADDISON 99

ADDISON flame Retardant overall screened Instrumentation cables (Multipair) Re-2X(st)y PVC Outer Sheath Tinned Copper Drain Wire PETP Transparent Tape XLPE Insulation Plain Annealed Copper PETP Transparent Tape Aluminium/polyester Tape application The unarmoured PVC versions (Part 1 Type 1) are generally use for indoor installation and suitable for wet and damp areas. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services. standards Basic design adapted to BS 5308 Part 1 Type 1 fire PeRfoRMance Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. VolTaGe RaTInG 300/500V cable construction conductor: Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(class 5), 0.5 mm², 1.0 mm² solid(class 1), 1.5mm² or 2.5mm², multistranded(class 2) to BS6360 Insulation: XLPE (Cross Linked Polyethylene), or PE (optional) Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm binder tape: PETP transparent tape overall screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² 100 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. COLOUR CODE Insulation Colour: See technical information Outer sheath: Black or blue Physical AND THERMAL PROPERTIES Maximum Operating temperature: -20 C - + 90 C( fixed installation) 0 C - +50 C(during operation) Minimum bending radius: 5 x Overall Diameter Electrical Properties Conductor Area Size mm 2 0.5 0.5 0.75 1.0 1.5 Conductor Stranding No. x mm 1 x 0.8 16 x 0.2 24 x 0.2 1 x 1.13 7 x 0.53 Conductor resistance max ohm/km 36.8 39.7 26.5 18.2 12.3 Insulation resistance min Capacitance unbalance at 1 khz(pair to pair screen) Max. Mutual Capacitance @ 1 khz fornon OS or OS cables (except one-pair and twopairs) Max. Mutual Capacitance @ 1 khz IS/OS cables (include 1 pair and 2 pair) Max. L/R Ratio for adjacent cores(inductance/resistance) Test voltage Gohm/ km 5 5 5 5 5 pf/250m 250 pf/m 115 115 115 115 115 pf/m 75 75 75 75 75 μh/ohm 25 25 25 25 40 Core to core V 1000 1000 1000 1000 1000 Core to screen V 1000 1000 1000 1000 1000 ADDISON 101

ADDISON CONSTRUCTION PARAMETERS Number of Pairs Conductor No./ Diameter of Strands Conductor Cross- Section Insulation Thickness Sheath Thickness RE-2X(St)Y Overall Diameter Approx. Weight Area no./mm mm 2 mm mm mm kg/km 1 1/0.80 0.5 0.5 0.8 5.5 35 2 1/0.80 0.5 0.5 0.8 6.8 55 5 1/0.80 0.5 0.5 1.1 10.9 125 10 1/0.80 0.5 0.5 1.2 14.4 215 15 1/0.80 0.5 0.5 1.2 16.5 300 20 1/0.80 0.5 0.5 1.3 18.8 385 30 1/0.80 0.5 0.5 1.3 22.3 545 50 1/0.80 0.5 0.5 1.5 28.5 875 1 16/0.20 0.5 0.6 0.8 6.2 60 2 16/0.20 0.5 0.6 0.8 7.6 80 5 16/0.20 0.5 0.6 1.1 12.4 210 10 16/0.20 0.5 0.6 1.2 16.5 340 15 16/0.20 0.5 0.6 1.3 19.2 440 20 16/0.20 0.5 0.6 1.3 21.7 570 30 16/0.20 0.5 0.6 1.5 26.4 780 50 16/0.20 0.5 0.6 1.7 33.4 1130 1 24/0.2 0.75 0.6 0.8 6.7 75 2 24/0.2 0.75 0.6 0.9 8.4 100 5 24/0.2 0.75 0.6 1.2 13.8 250 10 24/0.2 0.75 0.6 1.3 18.4 450 15 24/0.2 0.75 0.6 1.5 21.1 600 20 24/0.2 0.75 0.6 1.5 24.4 920 30 24/0.2 0.75 0.6 1.7 29.5 980 50 24/0.2 0.75 0.6 2 37.6 1690 1 1/1.13 1 0.6 0.8 6.6 85 2 1/1.13 1 0.6 0.8 8 115 5 1/1.13 1 0.6 1.2 13.5 290 10 1/1.13 1 0.6 1.2 17.7 500 15 1/1.13 1 0.6 1.3 20.6 670 102 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Number of Pairs Conductor No./ Diameter of Strands Conductor Cross- Section Insulation Thickness Sheath Thickness RE-2X(St)Y Overall Diameter Approx. Weight Area no./mm mm 2 mm mm mm kg/km 20 1/1.13 1 0.6 1.5 23.8 950 30 1/1.13 1 0.6 1.5 28.4 1030 50 1/1.13 1 0.6 2 36.6 1750 1 7/0.53 1.5 0.6 0.8 7.5 100 2 7/0.53 1.5 0.6 0.9 9.3 150 5 7/0.53 1.5 0.6 1.2 15.6 360 10 7/0.53 1.5 0.6 1.3 20.9 690 15 7/0.53 1.5 0.6 1.5 24.6 880 20 7/0.53 1.5 0.6 1.5 27.8 1230 30 7/0.53 1.5 0.6 1.7 33.7 1560 50 7/0.53 1.5 0.6 2 43 2400 300/500V Rated Voltage BS 5308 N Standard Flame Retardancy** Reduced Fire Propagation** NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-1-2/EN50265-2-1 IEC60332-3-22/EN50266-2-4 ADDISON 103

ADDISON flame Retardant Individual and overall screened Instrumentation cables (Multipair) Re-2X(st)y PiMf PVC Outer Sheath Tinned Copper Drain Wire Aluminium/polyester Tape PVC Insulation Plain Annealed Copper PETP Transparent Tape Aluminium/polyester Tape application The unarmoured PVC versions (Part 1 Type 1) are generally use for indoor installation and suitable for wet and damp areas. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services. standards Basic design adapted to BS 5308 Part 1 Type 1 fire PeRfoRMance Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. VolTaGe RaTInG 300/500V cable construction conductor: Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(class 5), 0.5 mm², 1.0 mm² solid(class 1), 1.5mm² or 2.5mm², multistranded(class 2) to BS6360 Insulation: XLPE (Cross Linked Polyethylene), or PE (optional) Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm Individual screen: Aluminium/polyester tape is applied over each pair metallic side down in contact with tinned copper drain wire, 0.5mm² binder tape: PETP transparent tape 104 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. COLOUR CODE Insulation Colour: See technical information Outer sheath: Black or blue Physical AND THERMAL PROPERTIES Maximum Operating temperature: -20 C - + 90 C( fixed installation) 0 C - +50 C(during operation) Minimum bending radius: 5 x Overall Diameter Electrical Properties Conductor Area Size mm 2 0.5 0.5 0.75 1.0 1.5 Conductor Stranding No. x mm 1 x 0.8 16 x 0.2 24 x 0.2 1 x 1.13 7 x 0.53 Conductor resistance max ohm/km 36.8 39.7 26.5 18.2 12.3 Insulation resistance min Gohm/km 5 5 5 5 5 Rated voltage max V 300/500 300/500 300/500 300/500 300/500 Capacitance unbalance at 1 khz(pair to pair screen) pf/250m 250 Max. Mutual Capacitance @ 1 khz fornon OS or OS cables (except one-pair and twopairs) pf/m 115 115 115 115 115 Max. Mutual Capacitance @ 1 khz IS/OS cables (include 1 pf/m 75 75 75 75 75 pair and 2 pair) Max. L/R Ratio for adjacent cores(inductance/resistance) μh/ohm 25 25 25 25 40 Test voltage Core to core V 1000 1000 1000 1000 1000 Core to screen V 1000 1000 1000 1000 1000 CONSTRUCTION PARAMETERS No./ Conductor Approx. Number Diameter Cross- Insulation Sheath Overall of Pairs of Weight Section Area Thickness Thickness Diameter Strands No./mm mm 2 mm mm mm kg/km 2 1/0.8 0.5 0.5 0.9 9.7 95 ADDISON 105

ADDISON No./ Conductor Approx. Number Diameter Cross- Insulation Sheath Overall of Pairs of Weight Section Area Thickness Thickness Diameter Strands No./mm mm 2 mm mm mm kg/km 5 1/0.8 0.5 0.5 1.2 13 180 10 1/0.8 0.5 0.5 1.2 16.9 310 15 1/0.8 0.5 0.5 1.3 19.7 440 20 1/0.8 0.5 0.5 1.3 22.3 560 30 1/0.8 0.5 0.5 1.5 27.1 820 50 1/0.8 0.5 0.5 2 35 1370 2 16/0.2 0.5 0.6 1.1 11.2 110 5 16/0.2 0.5 0.6 1.2 14.5 250 10 16/0.2 0.5 0.6 1.3 19.3 480 15 16/0.2 0.5 0.6 1.5 22.6 570 20 16/0.2 0.5 0.6 1.5 25.7 780 30 16/0.2 0.5 0.6 1.7 31 1020 50 16/0.2 0.5 0.6 2.2 39.9 1680 2 1/1.13 1 0.6 1.1 11.9 200 5 1/1.13 1 0.6 1.2 15.4 290 10 1/1.13 1 0.6 1.3 20.5 580 15 1/1.13 1 0.6 1.5 24.1 780 20 1/1.13 1 0.6 1.7 27.7 1010 30 1/1.13 1 0.6 2 33.7 1430 50 1/1.13 1 0.6 2.2 42.5 2360 2 7/0.53 1.5 0.6 1.2 13.6 250 5 7/0.53 1.5 0.6 1.3 17.7 460 10 7/0.53 1.5 0.6 1.5 23.9 760 15 7/0.53 1.5 0.6 1.7 28 1020 20 7/0.53 1.5 0.6 2 31.7 1350 30 7/0.53 1.5 0.6 2.2 38.6 1900 50 7/0.53 1.5 0.6 2.2 48.9 3060 300/500V Rated Voltage BS 5308 N Standard Flame Retardancy** Reduced Fire Propagation** NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-1-2/EN50265-2-1 IEC60332-3-22/EN50266-2-4 106 Caledonian

Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened, armoured Instrumentation cables (Multipair) Re-2X(st)ysWay PVC Outer Sheath Tinned Copper Drain Wire PETP Transparent Tape PVC Inner Sheath PVC Insulation Plain Annealed Copper Aluminium/polyester Tape Galvanized Steel Wire Armour application The armoured PVC versions (Part 1 Type 2) are generally used when the risk of mechanical damage is increased. The galvanized steel wire armour provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services. standards Basic design adapted to BS 5308 Part 1 Type 2 fire PeRfoRMance Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. VolTaGe RaTInG 300/500V cable construction conductor: Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(class 5), 0.5 mm², 1.0 mm² solid(class 1), 1.5mm² or 2.5mm², multistranded(class 2) to BS6360 Insulation: XLPE (Cross Linked Polyethylene), or PE (optional) Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm binder tape: PETP transparent tape overall screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in ADDISON 107

ADDISON contact with tinned copper drain wire, 0.5mm² Inner Sheath: PVC compound Amouring: Galvanized steel wire armour Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.colour CODE Insulation Colour: See technical information Outer sheath: Black or blue Physical AND THERMAL PROPERTIES Maximum Operating temperature: -20 C - + 90 C( fixed installation) 0 C -+50 C(during operation) Minimum bending radius: 6 x Overall Diameter Electrical Properties Conductor Area Size mm 2 0.5 0.5 0.75 1.0 1.5 Conductor Stranding No. x mm 1 x 0.8 16 x 0.2 24 x 0.2 1 x 1.13 7 x 0.53 Conductor resistance max ohm/km 36.8 39.7 26.5 18.2 12.3 Insulation resistance min Gohm/ km 5 5 5 5 5 Capacitance unbalance at 1 khz(pair to pair screen) pf/250m 250 Max. Mutual Capacitance @ 1 khz fornon OS or OS cables pf/m 115 115 115 115 120 (except one-pair and two-pairs) Max. Mutual Capacitance @ 1 khz IS/OS cables (include 1 pf/m 75 75 75 75 85 pair and 2 pair) Max. L/R Ratio for adjacent cores(inductance/resistance) μh/ohm 25 25 25 25 40 Test voltage Core to core V 1000 1000 1000 1000 1000 Core to screen V 1000 1000 1000 1000 1000 Rated voltage max V 300/500 300/500 300/500 300/500 300/500 108 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com CONSTRUCTION PARAMETERS Number of Pairs No./ Conductor Thickness Dia. of Weight Approx. Approx. Diameter Cross- Insulation Sheath Overall of Weight Section Thickness Thickness Diameter of Cable Strands Area Sheath no./mm mm 2 mm mm mm kg/km mm mm kg/km 1 1/0.80 0.5 0.5 0.8 5.5 0.9 1.3 9.9 200 2 1/0.80 0.5 0.5 0.8 6.8 0.9 1.3 11.2 260 5 1/0.80 0.5 0.5 1.1 10.9 0.9 1.4 15.5 460 10 1/0.80 0.5 0.5 1.2 14.4 1.25 1.6 20.1 790 15 1/0.80 0.5 0.5 1.2 16.5 1.25 1.6 22.2 1100 20 1/0.80 0.5 0.5 1.3 18.8 1.6 1.7 25.4 1280 30 1/0.80 0.5 0.5 1.3 22.3 1.6 1.8 29.1 1520 50 1/0.80 0.5 0.5 1.5 28.5 1.6 2 35.7 2100 1 16/0.2 0.5 0.6 0.8 6.2 0.9 1.3 10.6 250 2 16/0.2 0.5 0.6 0.8 7.6 0.9 1.3 12 300 5 16/0.2 0.5 0.6 1.1 12.4 0.9 1.5 17.2 560 10 16/0.2 0.5 0.6 1.2 16.5 1.25 1.6 22.2 970 15 16/0.2 0.5 0.6 1.3 19.2 1.6 1.7 25.8 1240 20 16/0.2 0.5 0.6 1.3 21.7 1.6 1.8 28.5 1640 30 16/0.2 0.5 0.6 1.5 26.4 1.6 1.9 33.4 1770 50 16/0.2 0.5 0.6 1.7 33.4 2 2.1 41.6 2770 1 24/0.2 0.75 0.6 0.8 6.7 0.9 1.4 10.9 280 2 24/0.2 0.75 0.6 0.9 8.4 0.9 1.4 12.8 330 5 24/0.2 0.75 0.6 1.2 13.8 1.25 1.6 19.3 750 10 24/0.2 0.75 0.6 1.3 18.4 1.6 1.8 24.3 1260 15 24/0.2 0.75 0.6 1.3 21.1 1.6 1.9 27 1480 20 24/0.2 0.75 0.6 1.5 24.4 1.6 2 31.4 1890 30 24/0.2 0.75 0.6 1.7 29.5 2 2.1 37 2440 50 24/0.2 0.75 0.6 2 37.6 2.5 2.4 47.3 3210 1 1/1.13 1 0.6 0.8 6.6 0.9 1.3 11 290 2 1/1.13 1 0.6 0.8 8 0.9 1.4 12.6 345 5 1/1.13 1 0.6 1.2 13.5 1.25 1.5 19 790 10 1/1.13 1 0.6 1.2 17.7 1.25 1.7 23.6 1310 15 1/1.13 1 0.6 1.3 20.6 1.6 1.8 27.4 1740 20 1/1.13 1 0.6 1.5 23.8 1.6 1.8 30.6 2040 ADDISON 109

ADDISON Number of Pairs No./ Conductor Thickness Dia. of Weight Approx. Approx. Diameter Cross- Insulation Sheath Overall of Weight Section Thickness Thickness Diameter of Cable Strands Area Sheath no./mm mm 2 mm mm mm kg/km mm mm kg/km 30 1/1.13 1 0.6 1.5 28.4 1.6 2 35.6 2180 50 1/1.13 1 0.6 2 36.6 2 2.2 45 3500 1 7/0.53 1.5 0.6 0.8 7.5 0.9 1.4 11.9 320 2 7/0.53 1.5 0.6 0.9 9.3 0.9 1.5 14.1 420 5 7/0.53 1.5 0.6 1.2 15.6 1.25 1.6 21.6 940 10 7/0.53 1.5 0.6 1.3 20.9 1.6 1.8 27.4 1500 15 7/0.53 1.5 0.6 1.5 24.6 1.6 1.9 31.2 1970 20 7/0.53 1.5 0.6 1.5 27.8 1.6 2 35.8 2400 30 7/0.53 1.5 0.6 1.7 33.7 2 2.2 42.3 3170 50 7/0.53 1.5 0.6 2 43 2.5 2.5 53.2 5020 300/500V Rated Voltage BS 5308 N Standard Flame Retardancy** Reduced Fire Propagation** NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-1-2/EN50265-2-1 IEC60332-3-22/EN50266-2-4 110 Caledonian

Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant Individual and overall screened, armoured Instrumentation cables (Multipair) Re-2X(st)ysWay PiMf Galvanized Steel Wire Armour Tinned Copper Drain Wire PETP Transparent Tape PVC Inner Sheath PVC Insulation Plain Annealed Copper Aluminium/polyester Tape Aluminium/polyester Tape PVC Outer Sheath application The armoured PVC versions (Part 1 Type 2) are generally used when the risk of mechanical damage is increased. The galvanized steel wire armour provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services. standards Basic design adapted to BS 5308 Part 1 Type 2 fire PeRfoRMance Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. VolTaGe RaTInG 300/500V cable construction conductor: Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(class 5), 0.5 mm², 1.0 mm² solid(class 1), 1.5mm² or 2.5mm², multistranded(class 2) to BS6360 Insulation: XLPE (Cross Linked Polyethylene), or PE (optional) Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm ADDISON 111

ADDISON Individual Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² Binder tape: PETP transparent tape Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² Inner Sheath: PVC compound Amouring: Galvanized steel wire armour Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. COLOUR CODE Insulation Colour: See technical information Outer Sheath: Black or blue Physical AND THERMAL PROPERTIES Maximum Operating temperature: -20 C - + 90 C( fixed installation) 0 C - +50 C(during operation) Minimum bending radius: 6 x Overall Diameter Electrical Properties Conductor Area Size mm 2 0.5 0.5 0.75 1.0 1.5 Conductor Stranding No. x mm 1 x 0.8 16 x 0.2 24 x 0.2 1 x 1.13 7 x 0.53 Conductor resistance max ohm/km 36.8 39.7 26.5 18.2 12.3 Insulation resistance min Gohm/km 5 5 5 5 5 Capacitance unbalance at 1 khz(pair to pair screen) pf/250m 250 Max. Mutual Capacitance @ 1 khz fornon OS or OS cables (except one-pair and two-pairs) Max. Mutual Capacitance @ 1 khz IS/OS cables (include 1 pair and 2 pair) pf/m 115 115 115 115 120 pf/m 75 75 75 75 85 Max. L/R Ratio for adjacent μh/ohm 25 25 25 25 40 cores(inductance/resistance) Core to core V 1000 1000 1000 1000 1000 Test voltage Core to screen V 1000 1000 1000 1000 1000 Rated voltage max V 300/500 300/500 300/500 300/500 300/500 112 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com CONSTRUCTION PARAMETERS No./ Conductor Diameter Inner No.of Diameter Cross- Insulation Overall Armour Sheath Overall of Sheath Pairs Section Thickness Inner Thickness Thickness Diameter Strands Thickness Area Sheath Approx. Weight no./mm mm 2 mm mm mm mm mm mm kg/km 2 1/0.80 0.5 0.5 0.9 9.7 0.9 1.4 14.3 380 5 1/0.80 0.5 0.5 1.2 13 1.25 1.5 18.5 640 10 1/0.80 0.5 0.5 1.2 16.9 1.25 1.7 22.8 890 15 1/0.80 0.5 0.5 1.3 19.7 1.6 1.7 26.3 1350 20 1/0.80 0.5 0.5 1.3 22.3 1.6 1.8 29.1 1470 30 1/0.80 0.5 0.5 1.5 27.1 1.6 1.9 34.1 1870 50 1/0.80 0.5 0.5 2 35 2 2.2 43.4 3000 2 16/0.2 0.5 0.6 1.1 11.2 0.9 1.5 16 460 5 16/0.2 0.5 0.6 1.2 14.5 1.25 1.6 20.2 760 10 16/0.2 0.5 0.6 1.3 19.3 1.6 1.8 26.1 1300 15 16/0.2 0.5 0.6 1.5 22.6 1.6 1.8 29.4 1440 20 16/0.2 0.5 0.6 1.5 25.7 1.6 1.9 32.7 1870 30 16/0.2 0.5 0.6 1.7 31 2 2.1 39.2 2400 50 16/0.2 0.5 0.6 2.2 39.9 2.5 2.4 49.7 3930 2 24/0.2 0.75 0.6 1.1 12.1 0.9 1.5 16.9 500 5 24/0.2 0.75 0.6 1.2 15.7 1.25 1.6 21.4 920 10 24/0.2 0.75 0.6 1.3 20.9 1.6 1.7 27.5 1610 15 24/0.2 0.75 0.6 1.5 24.6 1.6 1.9 31.6 1960 20 24/0.2 0.75 0.6 1.5 27.9 1.6 1.9 34.9 2420 30 24/0.2 0.75 0.6 2 34.4 2 2.2 42.8 3180 50 24/0.2 0.75 0.6 2.2 43.5 2.5 2.5 53.5 4506 2 1/1.13 1 0.6 1.1 11.9 0.9 1.5 16.7 515 5 1/1.13 1 0.6 1.2 15.4 1.25 1.6 21.1 950 10 1/1.13 1 0.6 1.3 20.5 1.6 1.8 27.3 1330 15 1/1.13 1 0.6 1.5 24.1 1.6 1.9 31.1 1680 20 1/1.13 1 0.6 1.7 27.7 2 2 35.7 2540 30 1/1.13 1 0.6 2 33.7 2 2.2 42.1 2900 50 1/1.13 1 0.6 2.2 42.5 2.5 2.5 52.5 4800 2 7/0.53 1.5 0.6 1.2 13.6 1.25 1.6 19.3 730 5 7/0.53 1.5 0.6 1.3 17.7 1.6 1.7 24.3 1180 ADDISON 113

ADDISON No./ Conductor Diameter Inner No.of Diameter Cross- Insulation Overall Armour Sheath Overall of Sheath Pairs Section Thickness Inner Thickness Thickness Diameter Strands Thickness Area Sheath Approx. Weight no./mm mm 2 mm mm mm mm mm mm kg/km 10 7/0.53 1.5 0.6 1.5 23.9 1.6 1.9 30.9 1820 15 7/0.53 1.5 0.6 1.7 28 2 2 36 2350 20 7/0.53 1.5 0.6 1.7 31.7 2 2.1 39.9 3030 30 7/0.53 1.5 0.6 2 38.6 2 2.5 48.6 4050 50 7/0.53 1.5 0.6 2.2 48.9 2 2.7 59.3 5960 300/500V Rated Voltage BS 5308 N Standard Flame Retardancy** Reduced Fire Propagation** NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-1-2/EN50265-2-1 IEC60332-3-22/EN50266-2-4 114 Caledonian

Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com BS 5308 Part 1 Colour Code BS 5308 Part 1 Colour Identification Pair No. a-wire b-wire Pair No. a-wire b-wire 1 Black Blue 26 White Yellow 2 Black Green 27 Red Yellow 3 Blue Green 28 Orange Yellow 4 Black Brown 29 Black Grey 5 Blue Brown 30 Blue Grey 6 Green Brown 31 Green Grey 7 Black White 32 Brown Grey 8 Blue White 33 White Grey 9 Green White 34 Red Grey 10 Brown White 35 Orange Grey 11 Black Red 36 Yellow Grey 12 Blue Red 37 Black Violet 13 Green Red 38 Blue Violet 14 Brown Red 39 Green Violet 15 White Red 40 Brown Violet 16 Black Orange 41 White Violet 17 Blue Orange 42 Red Violet 18 Green Orange 43 Orange Violet 19 Brown Orange 44 Yellow Violet 20 White Orange 45 Grey Violet 21 Red Orange 46 Black Turquoise 22 Black Yellow 47 Blue Turquoise 23 Blue Yellow 48 Green Turquoise 24 Green Yellow 49 Brown Turquoise 25 Brown Yellow 50 White Turquoise Single Quad (2 pair) are colour coded in clockwise order of rotation: Black, Blue, Green and Brown Individually screened pairs can also be identified by means of a polyester tape over blue and black pairs For cables in triple configuration please request colour code at time of enquiry Instrument Cables BS 5308 Part 2 Colour code ADDISON 115

ADDISON BS 5308 Part 2 Colour Identification Pair No. a-wire b-wire Pair No. a-wire b-wire 1 White Blue 26 Red Blue Blue 2 White Orange 27 Red Blue Orange 3 White Green 28 Red Blue Green 4 White Brown 29 Red Blue Brown 5 White Grey 30 Red Blue Grey 6 Red Blue 31 Blue Black Blue 7 Red Orange 32 Blue Black Orange 8 Red Green 33 Blue Black Green 9 Red Brown 34 Blue Black Brown 10 Red Grey 35 Blue Black Grey 11 Black Blue 36 Yellow Blue Blue 12 Black Orange 37 Yellow Blue Orange 13 Black Green 38 Yellow Blue Green 14 Black Brown 39 Yellow Blue Brown 15 Black Grey 40 Yellow Blue Grey 16 Yellow Blue 41 White Orange Blue 17 Yellow Orange 42 White Orange Orange 18 Yellow Green 43 White Orange Green 19 Yellow Brown 44 White Orange Brown 20 Yellow Grey 45 White Orange Grey 21 White Blue Blue 46 Orange Red Blue 22 White Blue Orange 47 Orange Red Orange 23 White Blue Green 48 Orange Red Green 24 White Blue Brown 49 Orange Red Brown 25 White Blue Grey 50 Orange Red Grey *For bi- coloured cores the first colour is the base colour Single Quad (2 pair) are colour coded in clockwise order of rotation: Black, Blue, Green and Brown Individually screened pairs can also be identified by means of a polyester tape over blue and black pairs For cables in triple configuration please request colour code at time of enquiry 116 Caledonian