IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

Similar documents
A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

Industrial Products Catalogue. fire rated isolators. enclosed switchgear. footswitches bespoke equipment

25A 25A 32A 40A 40A 63A 63A 80A

switch Isolation & Control Equipment 20A A ...make the switch

Industrial Products Catalogue

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

An innovative technology

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SENTRON Switching and Protection Devices Switch Disconnectors

Changeover & Bypass Sw it ches

switch disconnectors switch disconnectors fuses

Wall mounted switchgear

Vistop TM isolating switches 63 to 160A

Fuse Combination Units

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

PowerLine OS Switch Fuses A, 690V

Euroload Changeover Switch

Motorized switch-disconnectors OTM 40 to 125 Amperes

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

Switching. Overview. Contents

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

Loadswitch. Fuse Combination Units


ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

MS25, MST25, MS20, MST20

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Switch Disconnectors

General Characteristics

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

LOAD BREAK SWITCHES AND SWITCH FUSES

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Switch disconnectors

KATKO Safety Switches:

PowerLine Switch Fuses OESA_PL, A. Contents: Technical data... 9/2. Ordering information DIN-pattern... 9/3 BS-pattern...

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SWITCH FUSES 3KL71 from 32A to 800A Description

TeSys enclosed starters 2 VARIO enclosed switch disconnectors, pre-assembled

DPX moulded case circuit breakers

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

GE Power Controls. MiniFORM Switchboards

SD Series Non-Fused Load Switches

MOULDED CASE CIRCUIT BREAKERS BC160N

Just the right switch for your application

Extensible Unit - VCE2a

Contents. Volume 5 Motor Control and Protection CA E December

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Switch Fuses Sizes 32A, 63A, 125A, 200A, 315A, 400A, 630A, 800A

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

Contactor Types CI 61-98

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Enclosed Switches and Safety Switches

TECHNICAL SPECIFICATIONS OF PCC PANEL

D509E. Manual Motor - Starters

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

What you need to know. Â Conformity to standards

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

BETA Switching Switches and Light Indicators

Protection components

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Safety Switches Series 8537

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

Mini Contactors CI 4-

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

TeSys GS & DF Fuse protection

Motorised and automatic transfer enclosed switchess

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Sw it ch Disconnect or Fuse

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

Transcription:

General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors or Fuse Combination Units all items are supplied in generously sized enclosures which helps to avoid the need for extension boxes. The design offers a choice of accessories and options to match a variety of real world applications. IP41 Switch-Disconnectors (O-I) Rating Format Cat. No. Encl. Size 32 3P+N SD41G00323N 1 3P+NL SD41G00323NL 1 3P+N SD41G00633N 1 63 3P+NL SD41G00633NL 1 6P+2E/B SD41G00636EB 2 80 3P+N SD41GC00803N 1 3P+NL SD41GC00803NL 1 100 3P+N SD41GC01003N 3 3P+NL SD41GC01003NL 3 125 3P+N SD41GC01253N 4 3P+NL SD41GC01253NL 4 160 3P+N SD41GC01603N 4 3P+NL SD41GC01603NL 4 200 3P+N SD41GC02003N 5 3P+NL SD41GC02003NL 5 250 3P+N SD41G02503N 5 3P+NL SD41G02503NL 5 400 3P+N SD41G04003N 6 3P+NL SD41G04003NL 6 630 3P+N SD41G06303N 8 3P+NL SD41G06303NL 8 800 3P+N SD41G08003N 8 3P+NL SD41G08003NL 8 1000 3P+N SD41G10003N 10 3P+NL SD41G10003NL 10 N = switched neutral (Early make, late break) NL = Unswitched neutral (50% rated, 100% on request) Hinged Lid IP41 Enclosures The internal arrangement of a typical switch-disconnector (Isolator) Design Features Safety handle - when padlocked in the Off position, the enclosure door cannot be opened. Capable of accepting up to three padlocks in the Off position. (Locking in On position on request) Door interlock handle can be defeated to enable emergency opening or for testing purposes. (Must be carried out by a competent person) Removable gland plates on top & bottom of all enclosures. Enclosure size 2 and above isolating switches are mounted on a removable galvanised chassis plate. ll Fuse Combination Units are supplied complete with a set of fully rated fuse links. Terminal covers are supplied for incoming terminals. Earth terminals fitted to door and gland plates. Fuse Combination Units (O-I) Rating Format Cat. No. Enclosure Size 32 3P+NL SDF41G00323N 2 63 3P+NL SDF41G00633N 2 100 3P+NL SDF41G01003N 3 125 3P+NL SDF41G01253N 4 160 3P+NL SDF41G01603N 4 200 3P+NL SDF41G02003N 5 250 3P+NL SDF41G02503N 5 315 3P+NL SDF41G03153N 6 400 3P+NL SDF41G04003N 6 630 3P+NL SDF41G06303N 8 Page 19 Page 32 14

Hinged Lid IP41 Enclosures Spares/ccessories IEC/BS EN 60269 (BS88) fuse links For electrical ratings please refer to the following s:- Type - 13 Types B & C - Page 20 uxiliary Contacts dd-on auxiliary blocks are available for all IP41 products. Please select the blocks/kit from the tables below. ll auxiliaries are supplied as 1 N/O+1 N/C pair. ll N/O auxiliary contacts are early break with respect to the main poles when switching from On to Off. For Switch-Disconnectors Rating () 32-200 250 400-630 Cat No SUXCO SUXKITB SUXKITC Type C C For Fuse Combination Units Rating () 32-160 200-400 630 Cat No SUXKIT SUXKITC SUXKITD Type B C B Fuse Links ll of the Fuse Combination Units are supplied fitted with a set of fully rated IEC/BS EN 60269 (BS88) fuse links. Replacements can be supplied as individual fuse links to the table below. Fuse links can be fitted to a lower rating to suit a particular load: please refer to the rating table below to maintain the correct size/ tag format (2, 4, B1 etc.). Rating () 32 63 100 125 160 200 250 315 400 630 C&D Cat. No. SFL32 SFL63 SFL100 SFL125 SFL160 SFL200 SFL250 SFL315 SFL400 SFL630 Cooper Bussmann Cat. No. 032 B063 CE0100 DE0125 DD160 DD200 ED250 ED315 ED400 FF630 Lawson Cat. No. TI32 TIS63 TCP100 TFP125 TF160 TF200 TKF250 TKF315 TMF400 3T630 BS fuse format 2, 3 2, 3 4 4 B1, B2 B1-B2 B1-B2 B1-B4 B1-B4 C1-C3 Terminal Covers Terminal protection is provided on all items for live incoming terminals; spare terminal covers are available for replacement or extending the protection to the outgoing terminals. - individual covers For Switch-Disconnectors Page 19 Page 32 Isol Rating () 32-160 200 250-400 630 Cat No Not reqd STS1 STS2 STS4 For Fuse Combination Units Isol Rating () 32-63 100-160 200-400 630 Cat No Not reqd STS1 STS2 STS3 15 craigandderricott.com

- Hinged Lid ssemblies Specification Switch-Disconnectors Rating () 3P 3P 6P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P pplication Sym Unit Category 32 63 63 80 100 125 160 200 250 400 630 800 1000 32 63 63 80 100 125 160 200 270 500 630 720 1000 V 690 690 690 690 1000 1000 1000 1000 1000 1000 1000 1000 1000 kv 6 6 6 6 8 8 8 8 12 12 12 12 8 Rated operational current (C) I e Rated operational current (DC) ( /poles in series) Rated operational power P e kw I e 400V - C21 32 63 63 80 100 125 160 200 250* 400* 630* 800* 1000* 690V - C21 32 63 63 80 100 125 160 200 250 400 630 800 1000 400V - C22 - - - - 100 125 160 200 250* 400* 630* 800* 1000* 690V - C22 - - - - 100 125 160 160 250 400 630 800-400V - C23 29 48 48 56 100 112 128 128 250* 400* 630* 720* - 690V - C23 17 33 33 33 - - - - 250 350 350 350 - Up to 48V - DC21 32/1 63/1-80/1 - - - - 250/2 400/2 630/1 800/1 1000/1 220V - DC21 32/3 63/4-80/4 - - - - 250/2 400/2 630/2 800/2 1000/3 Up to 48V - DC22 - - - - - - - - 250/2 400/1 630/1 800/1-220V - DC22 - - - - - - - - 250/2 400/2 630/2 800/2 - Up to 48V - DC23 - - - - - - - - 250/2 400/1 630/1 800/1-220V - DC23 - - - - - - - - 250/2 400/2 630/2 630/2-400/415V - C23 15 25 25 30 59 63 75 75 132 200 315 355 400 690V - C23 15 30 30 30 51 55 55 55 200 315 355 355 - Short circuit making capacity I cm k Peak value 1.4 2.9-3.0 3.7 4.0 5.0 5.0 35 65 80 80 105 Short circuit withstand (1sec) I cw k rms value 0.6 1.3 1.3 1.4 2.6 2.8 3.0 3.0 8 17 17 17 50 Min. mechanical endurance - Operations (10 3 ) 250 250-250 50 50 50 50 16 10 10 10 6 Min. electrical endurance - 415V - at 0.65 pf - - - - - - - - 1,000 1,000 500 500 500 mm 2 Min/Max 2.5/10 2.5/25 2.5/25 -/25 -/70 -/70 -/70 -/95 mm Stud/Cu palm width - - - - - - - 8x25 10x30 10x30 12x40 12x40 12x60 Nm Tightening torque 1.2 1.3 1.3 2 2 2 2 12 25 25 40 40 40 * ll C21, C22 & C23 tests carried out at 415V...products for the real world 19 craigandderricott.com

Specification * Two poles in series Specification Fuse Combination Units Changeover Switch-Disconnectors Rating () pplication Sym Unit Category 32 63 100 125 160 200 250 315 400 630 32 63 100 125 160 200 250 315 400 630 V 750 750 750 750 750 750 750 750 750 750 kv 12 12 12 12 12 12 12 12 12 12 Rated operational current (C) 415V - C23 32 63 100 125 160 200 250 315 400 630 I e Rated operational current (DC)* 220V - DC23 - - 100 125 160 200 250 315 400 630 Rated making capacity (C23) 415V, 0.35 pf 320 630 1,000 1,250 1,600 2,000 2,500 3,150 4,000 6,300 Rated breaking capacity (C23) 415V, 0.35 pf 256 504 800 1,000 1,280 1,600 2,000 2,520 3,200 5,040 Rated Conditional (Fused) short circuit k S/C current rms 80 80 80 80 80 80 80 80 80 80 back-up fuse 32 63 100 125 160 200 250 315 400 630 Min. mechanical endurance - Operations 25,000 25,000 15,000 15,000 15,000 10,000 10,000 10,000 10,000 6,000 Min. electrical endurance - 415V - at 0.65 pf 1,500 1,500 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 BS fuse format 2 2 4 4 B1, B2 B1, B2 B1, B2 B1, B4 B1, B4 C1, C3 mm 2 Min/Max 16 25 95 95 120 240 240 300 300 400 mm Stud/Cu palm width - - 8x20 8x20 8x20 10x25 10x25 10x25 10x25 12x50 Nm Tightening torque 3.5 5.5 9 12 16 25 30 35 45 50 Rating () pplication Sym Unit Category 63 100 125 160 200 250 400 630 63 100 125 160 200 250 400 630 V 750 750 1000 1000 1000 1000 1000 1000 kv 6 6 6 6 6 12 12 12 Rated operational current I e 415V - C22 63 100 125 160 200 250 400 630 415V - C23 63 100 125 160 200 250 400 630 Rated making capacity (C23) 415V, 0.35 pf 630 630 1,250 1,600 2,000 2,500 4,000 6,300 Rated breaking capacity (C23) 415V, 0.35 pf 504 504 1,000 1,280 1,600 2,000 3,200 5,040 Short circuit current k rms (with fuses) 80 80 80 80 80 100 100 80 Rated S/C making capacity k Peak 15 15 20 20 20 30 40 50 Min. mechanical endurance - Operations 20,000 20,000 10,000 10,000 10,000 10,000 10,000 10,000 Min. electrical endurance - 415V - at 0.65 pf 2,500 1,500 1,000 1,000 1,000 1,000 1,000 500 mm 2 Max 35 35 95 95 95 240 300 400 mm Stud/Cu palm width 6x12 6x12 8x22 8x22 8x22 10x25 10x25 12x50 Nm Tightening torque 3 3 10 10 10 30 45 50 - Hinged Lid ssemblies uxiliary Blocks supplied against tests to BS EN 60947-1 Sym. Category uxiliary blocks type B uxiliary blocks type C Thermal current I th 10 10 660V a.c. or d.c. 500V Utilisation Category - C15 6.0 at 120V, 4.0 at 250V, 2.0 at 660V 240V - Make 30, Break 3 480V - Make 15, Break 1.5 DC13 1.0 at 120V, 0.5 at 240V, 0.1 at 660V 240V - Make 30, Break 3 480V - Make 15, Break 1.5 Pure Resistive 10-20

Hinged Lid Enclosures ØØ F G (CRS) C Handle projection Gland plate thickness (K) D Ø 4 off internal mounting holes B W H Enclosure Sizes Dim 1 2 3 3 4 4 5 5 6 7 8 9 10 H 250 250 400 350 500 400 550 550 750 750 900 900 1000 W 250 300 350 300 350 300 450 400 450 600 600 600 750 D 100 200 200 175 200 175 250 175 275 300 300 400 300 170 170 320 270 420 320 470 470 670 670 820 820 920 J (CRS) E External Mounting Feet (Four per set) Case Sizes 1 & 2 Cat No. SEFL1/KIT Case Sizes 3-7 Cat No. SEFL2/KIT Case Sizes 8-10 Cat No. SEFL3/KIT & Fixings B 170 220 270 220 270 220 370 320 370 520 520 520 670 C 40 67 67 67 67 67 67 67 67 67 67 67 67 K 1.5 1.5 1.5 2.0 1.5 2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5 Ø 6.5 6.5 8.5 8.5 8.5 8.5 8.5 8.5 8.5 8.5 10.5 10.5 10.5 External Feet E 35 35 35 35 35 35 35 35 35 35 35 35 35 F 53 58 58 58 58 58 58 58 58 58 58 58 58 G 18 18 13 13 13 13 13 13 13 13 13 13 13 J 58 58 58 58 58 58 58 58 58 58 58 58 58 ØØ 6.5 6.5 8.5 8.5 8.5 8.5 8.5 8.5 8.5 8.5 10.5 10.5 10.5 Enclosure Materials IP41 items IP65 items Finish IP41 & IP65 Sheet steel Sheet steel or stainless steel Sheet steel, iron phosphate pre treatment with a powder coat RL 7035 (Light grey) textured finish. IP65 Stainless steel, grade 304 with a brushed finish. Hinges Metal with quick release pins. Door Locks ll metal locks supplied with one key per enclosure. Enclosures 1 & 2 IP41-2 screw fixings IP65-1 lock Enclosures 3-9 IP41 & IP65-2 locks Enclosure size 10 IP41 & IP65-3 locks Gland plates ll enclosures are supplied with a removable gland plate on top & bottom faces finished to match the enclosure. Chassis plate bove enclosure size 1, all assemblies have the switching element mounted on a removable chassis plate. Matl.- 2mm zinc plated steel....products for the real world Page Page 32