Micro-Air Corporation Route 526 Allentown, NJ 08501

Similar documents
EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart Installation Instructions for Dometic Family RV A/Cs

Advanced EasyStart Troubleshooting

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

AeroVironment Universal Solar Pump Controllers

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Model C230 Pump Controller

G72x Series Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

Model LA 4400 Time Delay OFF Controller

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

HPV 100 Hydraulic Elevator Soft-Starter Technical Manual

SAFETY WARNINGS AND GUIDELINES

Operators Manual. Recirculating Chiller /06/08

Generator Start Control Module

Patient Care Facility

Application Engineering

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Power Supply. Model PS-200

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Mechanical Spiral Sensor

Model LA 4100 Time Delay OFF Controller

Boston Gear Ratiotrol DC Motor Speed Control

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Motorized Stainless 2-Way Valves

Generator Start Control Module

Model LA 4300 Time Delay OFF Controller

Application Engineering

FHC-1D user manual. Features

Instruction Manual for the 110 VAC Draw-off Controller System

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

INSTALLATION INSTRUCTIONS

UNISTEER Performance Products UNIVERSAL HOT ROD ELECTRA-STEER KIT

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Patient Care Facility

230VAC Power Inverter 400W Owner s Manual

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

Petrochemical processing Ship Yards Oil Fields Irrigation

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

MODEL 422 Submersible Pump Controller

INSTALLATION/OPERATING INSTRUCTIONS TSC

Sierra 80 Volt Brushless DC Motor Controller Product Specification

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

AUTO CHARGE D PUMP PLUS

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

O W N E R ' S M A N U A L

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

System 3 ZB1PS Device Chassis. Operator s Manual

Installation Instructions for Eaton Surge Protective

SECTION MOTOR REQUIREMENTS for HVAC

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Modulating Furnace Information. Warning on Meter Setting - Read First!

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

SPC-PANEL Simplex, Single Phase Pump Control Panel

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

600 Amp Battery Jumper with Air Compressor

Generator Start Control Module

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

RVS-DN Digital Reduced Voltage Motor Starter

A4 Coolant Fan testing, MANUAL Air Conditioning

OPERATION AND MAINTENANCE

Owner s Guide CARS & CA4B5

Power Inverter 400 MW Owner s Manual

RVS-DX Digital Reduced Voltage Motor Starter

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

SOLAR DASH CHARGING SYSTEM USER GUIDE

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Owner s Guide PR1BZ PR1BZLR

FK75 / FK95 Quick Installation Guide

Installation, Operation and Maintenance Manual

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

The Power of Reliability INSTRUCTION MANUAL

USER MANUAL AND INSTALLATION GUIDE ENGINE RPM AND NOS SHIFT COUNTER NOS DELAY TIME IN SECONDS NOS START PERCENT NOS FINAL PERCENT

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

Dolphin TM 6110 Mobile Computer. Quick Start Guide

Installation & Operators Manual

Series 2100 Operating Instructions

Transcription:

EasyStart 366 Commercial (board-only) Model ASY-366-X05 (36000 BTU, 3 ton) ASY-366-X06 (72000 BTU, 6 ton) Micro-Air Corporation www.microair.net 124 Route 526 help@microair.net Allentown, NJ 08501

Contents Introduction... 3 Common questions about EasyStart 366... 3 Why is it better than a Hard Start kit?... 3 What applications should use the low cost 366 starter?... 3 How is the 366 different from the 364 or 368 starters?... 4 What kind of enclosure is required for the 366?... 4 Which model 366 do I need?... 4 What size capacitor should I use?... 4 Installation... 5 Identifying the board... 5 Installing the EasyStart 366 board... 5 Wiring the board... 5 Starting the system for the first time... 5 Troubleshooting... 6 Faults... 6 Jumper Settings... 6 Fixed Start... 6 Relearn... 6 Start winding fuse... 7 FAQ... 7 Can I install the 366 on my RV, home AC, refrigerator etc.?... 7 Can I use 366 for my electric motor (well pump, air compressor, wash down motor etc.)?... 7 How do I contact Microair?... 7 My motor or compressor size is not listed. What start capacitor do I use?... 7 Wiring... 8 Diagram 1: ASY-366 Standard Wiring... 8 Diagram 2: ASY-366 with Split Cap Fan... 9 Specifications... 10 Warranty... 10 Mounting template... 11 September 5, 2018 rev 1.09 2

Introduction EasyStart is a one-of-a-kind soft starter for single-phase motors operating at 115VAC or 230VAC, 50Hz or 60Hz, custom developed by Micro-Air. It uses a highlysophisticated, microprocessor-controlled system that employs a 4-part start ramp that is precisely sequenced using real-time closed-loop control. EasyStart even optimizes itself as it "learns" your compressor motor during the first few startups. This advanced system enables EasyStart to deliver up to 65-75% start current reduction. EasyStart also has numerous specialized fault checks not found in any other soft starter that provide further protection for your compressor motor. The many features EasyStart incorporates make it the perfect solution to allow an air conditioner or refrigeration compressor to operate on a generator, inverter, or limited utility power when it would otherwise not have functioned. It can also be applied to air compressor, pump motors and other single phase motors. Common questions about EasyStart 366 Why is it better than a Hard Start kit? EasyStart is not a hard start kit or a start capacitor alone. A hard start adds current to the start winding during the start process. The current reduction you see is because of the phase difference between voltage and current during the start. These devices can deliver at best a 10-20% reduction to a compressor's normal startup lockedrotor amperage (LRA). In some instances no reduction may be seen by adding a hard start kit! EasyStart is totally different from a hard start. It controls the power applied to the compressor during the start and slightly lengthens the start process resulting in significantly less peak current draw. Some customers have reported a 75% reduction in start current! What applications should use the low cost 366 starter? This EasyStart model is designed mainly for air conditioning, refrigeration, water maker, and similar manufacturers that incorporate compressors or multi horsepower motors into their appliance products. Customers who understand what is required to install this product may also elect to purchase this product. The start capacitor, wiring, and enclosure are not included (board-only), providing a substantial cost savings. This product must be mounted inside an appropriate enclosure that prevents damage from moisture intrusion. An appropriately sized start capacitor and appropriately sized wiring must also be supplied by the installer. September 5, 2018 rev 1.09 3

How is the 366 different from the 364 or 368 starters? The 366 starter uses the same software and algorithms as the other starters. 366 starters do not have wiring harnesses, start capacitors or enclosures. It is designed to be installed by manufacturers who understand the requirements of enclosing, mounting and wiring and not for individual use. Engineering assistance can be provided for volume orders. Installation assistance is not provided. The 364 and 368 starters are designed to be fitted to existing motors and compressors. They are available in water proof IP66 rated enclosures and have wiring harnesses that simplify connections. Installation assistance is available for 364 and 368 models. What kind of enclosure is required for the 366? The 366 is designed to be installed in an area where it will not encounter moisture. Recommended installations include inside mounted electrical boxes or mounting inside a minimum of IP53 or NEMA 3 enclosures when used outside. Higher rated enclosures such as NEMA 4X or IP66 are strongly suggested for systems where high humidity or direct moisture contact can occur. Which model 366 do I need? The EasyStart 366 is available in two models. The X06 model is capable of supporting up to a 72000 BTU (6 ton) compressor. The X05 model is capable of supporting up to a 36000 BTU (3 ton) compressor. Model Number: Use with AC Motors up to: compressors up to: ASY-366-X05 3 Ton (36 KBTU) 25 RLA ASY-366-X06 6 Ton (72 KBTU) 35 RLA What size capacitor should I use? Compressor Capacity (BTU) Start Capacitor Size up to 12K 72-86 MFD 13 to 23K 88-106 MFD 24 to 36K 108-130 MFD 37 to 48K 189-227 MFD 49 to 72K 270-324 MFD Voltage Ratings: 115VAC applications can use 250V rating. 230VAC applications should use 330V rating. Note: Micro-Air does stock certain sizes of start capacitors. Please contact us for more information. September 5, 2018 rev 1.09 4

Installation Identifying the board The 36000 BTU (3 ton) rated X05 board uses Faston style spade terminals for L2 and Run connections on the board. The 72000 BTU (6 ton) rated X06 board uses wire insert spring terminals for the L2 and Run connections on the board. Installing the EasyStart 366 board The EasyStart 366 board comes with four mounting stand offs to mount in each of the four corners of the board. Drill four 0.144 in (3.66mm) holes in your enclosure using the template at the end of this manual. Note: Some printers do not print to scale very well. Verify the dimensions on the printed template with the board before drilling. Install the mounting stand-offs by pressing the threaded end of the standoff through the drilled panel hole and installing the nut with integrated lock washer. Install the board by placing the board on the stand-offs and installing four 6-32 machine screws with lock washers. Machine screws and nuts should be tightened to approximately 9 inch-pounds. Wiring the board Typical wiring is shown in diagrams 1 and 2 in this manual. Diagram 1 shows the standard wiring for a compressor only. Diagram 2 shows the wiring for a system with a split capacitor commonly found in HVAC systems with integrated fans. Additional information may be required for certain motor types such as motors with multiple or split windings and motors with a centrifugal clutch. See the FAQ section for more details. Starting the system for the first time When a compressor is first connected, EasyStart will learn for the first five starts of the compressor. After the learning process is complete, EasyStart chooses the best starting characteristic for the compressor. We strongly recommend the use of stable AC power such as utility power for the first five starts. After the first five starts, the system can be used on less stable power sources like inverter or generator power. September 5, 2018 rev 1.09 5

Troubleshooting Faults Three LED lights are provided to help diagnose detected faults. The actual LED indications for the following faults are shown in table in the wiring diagrams contained in this document. Restart attempts when available will occur after three minutes and forty seconds. Power Interrupted: A temporary power loss was detected and EasyStart shut down the compressor. If power is restored before EasyStart completely loses power, EasyStart will attempt a restart. Compressor Stall: An improper operating condition exists that is consistent with a stalled compressor. This condition is triggered by an improper signal on the start winding of the compressor. This can be caused by a broken start winding wire connection, a failed start capacitor, as well as a locked compressor rotor. Be sure your thermostat allows sufficient time for pressure equalization before restarts. No Start Winding Voltage: No signal was detected on the start winding. Verify the wiring to the winding is correct. Compressor Over Current: Compressor running current is limited to a maximum of 25 RLA for the 3-ton X05 model and 35 RLA for the 6-ton X06 model. EasyStart will shut down and indicate this fault if current exceeds this value. Open Compressor Overload: An improper operating condition exists that is consistent with an overload protector opening during operation. Any condition that causes the connection to the compressor to be broken can cause this fault. Jumper Settings Two options can be selected using the provided board mounted header and shorting jumper. Power must be removed from EasyStart when changing jumper settings. Fixed Start When the shorting jumper is placed on pins 1 and 3 in the Fixed Start position, EasyStart will use a factory defined short ramp on every start. This is used for diagnosing certain types of system problems and should only be used with manufacturer support. Relearn If a compressor is replaced with a different size, manufacturer or type of compressor, relearning may be required. Place the shorting jumper on pins 4 and 6. Start a cycle with the compressor control device and terminate the cycle. Remove the jumper from the relearn position and return it to the normal position. The learning process will occur thereafter as described in starting the system for the first time. September 5, 2018 rev 1.09 6

Start winding fuse A board mounted replaceable 5x20mm slow blow fuse is installed in the start winding circuit. This fuse may fail if the starter is connected to a compressor that is over sized or if the board is miswired. Boards with (-X05) extension have a 16 Amp, 250 VAC rated fuse. Boards with (-X06) extension have a 20 Amp, 250 VAC rated fuse. FAQ Can I install the 366 on my RV, home AC, refrigerator etc.? Although it is possible, we recommend ASY-364 or ASY-368 because they are ready to install on existing systems. 366 boards can be used however you will need to address electrical safety concerns, moisture intrusion and wiring for your installation. This support is not provided by Micro-Air as this product is intended for commercial use only. Can I use 366 for my electric motor (well pump, air compressor, wash down motor etc.)? Yes. You must be able to access the windings on the motor and have the wiring diagram for the motor. We have successfully installed EasyStart in many different applications although some are more challenging than others. Microair can assist volume customers in installing EasyStart into these more complicated installations. Please try to have a wiring diagram for your motor, start and run capacitor sizes, RLA, LRA, voltage, manufacturer, and model number for your motor when contacting Microair. How do I contact Micro-Air? Help@Microair.net My motor or compressor size is not listed. What start capacitor do I use? Many times the manufacturers recommended start capacitor will work when connected to EasyStart. We have found some split winding motors need significantly less capacitance when used at 230 VAC. Contact Micro-Air if you need assistance selecting a value. September 5, 2018 rev 1.09 7

Wiring Diagram 1: ASY-366 Standard Wiring September 5, 2018 rev 1.09 8

Diagram 2: ASY-366 with Split Cap Fan September 5, 2018 rev 1.09 9

Specifications Line voltage Frequency Maximum motor RLA Maximum start winding current (fuse protected) Minimum operating temperature Maximum operating temperature Maximum RH conditions (Board and display) Board height (X05) (X06) 100 to 250VAC 50 or 60 Hz 35 Amps (-X06) 25 Amps (-X05) 20 Amps (-X06) 16 Amps (-X05) 0 F (-17.8 C) 150 F (65.5 C) 95 % Non-condensing 1.375 (3.5cm) 2.20 (5.6cm) Warranty Micro-Air warrants new products sold by us to be free from manufacturing defects for a period of two (2) years commencing with delivery of the product to the original customer. Our obligation under this warranty is expressly limited at our option, to the replacement or the repair at Micro-Air or at a service facility designated by us, of such parts, as inspection shall disclose to have been defective. This warranty does not apply to defects caused by damage or unreasonable use, including failure to provide reasonable and necessary maintenance, while in the possession of the consumer. Micro-Air shall not be liable for consequential damages of any kind, including, but not limited to, consequential labor costs or transportation charges in connection with the replacement or repair of the defective parts. September 5, 2018 rev 1.09 10

Mounting template Above hole dimensions are in inches and are provided as a guide for drilling. All other dimensions are in thousandths of an inch. Note: Some printers do not print to scale very well. Verify the dimensions on the printed template with the board before drilling. COPYRIGHT 2018 Micro-Air Corporation, All Rights Reserved No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photocopying, recording or otherwise without prior written consent by Micro Air Corporation. Every precaution has been taken in the preparation of this manual to insure its accuracy. However, Micro Air Corporation assumes no responsibility for errors and omissions. Neither is any liability assumed nor implied for damages resulting from the use or misuse of this product and information contained herein. September 5, 2018 rev 1.09 11